Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.9 LAccepted-AOC 1 111 A VENUGOPAL SWAMY TEMPLE STREET LINGARAJAPURAM BANGALORE 5600 084 | 5600084 | L1 | Accepted-AOC Lowest bidder and found reasonable | |
| 2 | L2₹52.4 L+₹5.0 L (10.5%)Rejected-Finance | L2 | Rejected-Finance Not being lowest tenderer | |
| 3 | L3₹53.5 L+₹6.1 L (12.8%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | L3 | Rejected-Finance Not being lowest tenderer | |
| 4 | L4₹53.6 L+₹6.2 L (13.0%)Rejected-Finance NO 1 4 56 Y SRI BHARATHI NAGAR OPP PARVATHI THEATER CUMBUM ROAD THENKARAI PERIYAKULAM THENI DT 625 601 | PERIYAKULAM | THENI | TAMIL NADU | 625601 | L4 | Rejected-Finance Not being lowest tenderer | |
| 5 | L5₹55.6 L+₹8.2 L (17.2%)Rejected-Finance | L5 | Rejected-Finance Not being lowest tenderer |
Tender Value
₹45.9 L
EMD Value
₹91,800
Closing Date
5 Apr 2022, 6:00 pmClosed
GARRISON ENGINEER (SOUTH) BANGALORE
GARRISON ENGINEER (SOUTH) BANGALORE NO 1, ULSOOR ROAD BANGALORE-560 042
AS PER BOQ AND TENDER DOCUMENT
2022_MES_513083_1
8587/E8
Open Tender
Civil Works
Item Rate
180 days
GE(South) Bangalore
AS PER TENDER DOCUMENT
6 documents required · 6 mandatory
₹500
GARRISON ENGINEER (SOUTH) BANGALORE
₹91,800
Yes
10 Jun 2022
10 Mar 2022
7 Apr 2022
10 Mar 2022
5 Apr 2022
23 Mar 2022
Amount
Taking down cement plaster on brick or stone walls or concrete ceiling etc, incl raking out joints, hacking for key scrubbing down with water, etc. Including the removing the debris out side MD complete all as specified and as directed.
M&L rendering 5 mm thick on concrete surfaces (ceiling) in cement mortar in 1:3 & mixed with water Proofing bonding agent for bonding surfaces finished even and smooth without using extra cement complete all as specified and directed.
Demolition of cement concrete(unreinforced) in floors / roof and pavings not exceeding 15 cm thickness (below or above ground floor) & removing debris outside MD land complete all as specified and as directed.
M & L Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and directed.
M&L 40 mm thick cement concrete type B-1, 1:2:4 (using 20 mm graded crushed stone aggregate), as in roof treatment , sub base floor etc. Complete all as specified and as directed.
M&L for rendering 15 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces mixed with integral water proofing compound as per manufacturer's instructions, surfaces finished even and smooth without using extra cement complete all as specified and directed. (Note :- Water proofing compound shall be measured and paid for separately as supply only under relevant item of this schedule).)
Supply only integral water proofing compound ISI Marked as approved, all as specified and as directed.
Material and labour for cleaning the plastered/concrete surfaces with wire brushes and applying water proofing treatment as under :- (a) Applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sq. m including cleaning surfaces (b) APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyester non woven fabric (wt not less than 150 gms/sqm) laid on primed surface by forced application and finish the top surface with bituminus aluminium paint @0.10 Ltr per Sqm complete all as specified and as directed.
Demolition of cement concrete any description and in any position not otherwise specially provided including removing the debris out side MD land complete all as specified and as directed.
Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing), removing servicieable tiles to store and rubbish off the premises complete all as specified and as directed.
Roughning surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc & brushing neat cement slurry with 3.0 Kg of cement per sqm complete all as specified and as directed.
M&L 75 mm thick cement concrete type D-2 1:4:8 (using 40 mm graded crushed stone aggregate), as in sub base of floors complete all as specified and as directed.
S&F coloured non skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white cement or coloured cement to match over and including 15 mm thick screed bed in cement mortar 1:6. complete all as specified and as directed.
S&F coloured Glazed ceramic tile in verticle surface area exc 0.06 sqm but n.exc 0.12 sqm set and jointed in neat cement slurry and pointed in white or colour cement to match over and including rendering 10 mm thick on fair faces of brick work or concrete surfaces as backing coat in cement mortar 1:4 complete all as specified and as directed.
M&L in repairs 15 mm medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors including taking down of existing pipes complete all as specified and directed.
M&L in repairs 20 mm medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors including taking down of existing pipes complete all as specified and directed.
S &F in repair vitreous chinaware urinal half stall type white with grating & union for discharge pipe down take pipe etc. complete all as specified and directed.
S&F in repairs 15 mm bore push taps suitable for urinals any colour of PTMT screwed for iron pipe and fixed (Minium weight 15 mm-50gms). complete all as specified and directed.
S&F urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (min wt 60 gms). complete all as specified and directed.
S & F in repair PVC connection 15 mm dia with PTMT nuts of lenth 450 mm complete all as specified and directed.
S&F in repair 15 mm bore fancy type Two way Bib taps, cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in repair 15 mm bore fancy type Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in repair 15 mm bore concussive push button taps of cast copper alloy screwed for iron pipe and fixed complete all as specified and directed.
S&F in repair 15 mm bore pillar taps, cast copper alloy, with capstan heads, chromium plated screwed down high pressure with or without lattered 'Hot' or 'Cold' with long screwed for iron pipe and fixed complete all as specified and directed.
S&F 15 mm bore brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed.
S&F in repair 15 mm bore stop valves, fancy type chromium plated with long shank and cup (concealed type) cast copper alloy screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for union and fixed complete all as specified and directed.
S&F grating doom 125 mm dia with waste hole of PTMT. (Min wt 40 gms) all as specified and directed.
S&F in repair Brass chromium plated shower rose 125mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed.
S&F in repairs Sheet glass shelf assembly consisting 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed.
S&F liquid soap container of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats. (Min wt 105 gms) complete all as specified and directed.
S&F Towel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats. (Min wt 90 gms) complete all as specified and directed.
Supply and fix Health faucet (ABC Body) mild steel chromium plated suitable for 15mm dia pipe qith 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed.
S&F in repair Towel Rail 600 mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats. (min wt 190 gms) complete all as specified and directed.
S&F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors or in walls complete all as specified and directed.
PVC 110 mm bore (SWR), junction single, (Single T) equal or unequal with access door complete all as specified and directed.
PVC 110 mm bore (SWR) reducers all as specified and directed.
S&F 75 mm PVC (SWR) vent cowl complete all as specified and directed.
S&F in repair PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed.
S & F in repair washdown water closet orrissa pattern size 580x440mm white with integral footrest and trap, including connection to drain and to flushing pipe incl making good to floor and flush pipe and joint between flushing pipe and sockets of water closet pan complete all as specified and directed.
S & F in repair vitreous china washdown water closet pan & trap (pedestal pattern) with plastic water closet seat black closet pattern with flat bottom and cover and mild steel chromium plated or aluminium hinginng device with flush pipe to pedestal pan incl all joints incl connection to drain pipe and flush pipe complete all as specified and directed.
S&F in repair PVC low level flushing cistern 10 ltr capacity, valveless, syphonic action type with inlet, ball valve float and handle incl brakcet and flush pipe 32 mm dia complete all as specified and directed.
S & F in repair vitreous china white wash hand basin flat back size 550x400 mm incl brackets chain & plug and waste pipe waste coupling of PTMT (Min Wt 45-60Gms) etc. complete all as specified and directed.
S & F repair fancy type 15 mm dia stop cock/valve cast copper alloy screwed down, high pressure with ro without crutch or butterfly handle screwed both ends for iron pipe or for union and fixed complete all as specified and directed.
M & L hardcore of broken stone or boulders of gauge n.exc 63mm deposited spread and leveled in layer n.exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 75 mm thick, PCC 1:3:6 type C1 (using 20mm graded stone aggregate), finished even and smooth without using extra cement.as in plinth protection incl joints filling complete all as specified and directed.
M&L rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 incl finished even and smooth (without using extra cement) all as specified and directed.
M&L preparation of newly plastered surfaces of wall and applying two coats of cement base paint over a coat of primer surface all as specified and directed.
M&L preparation of newly plastered surfaces of wall and applying two coats of white wash all as specified and directed.
M&L for three coats of white wash on ceiling incl preparation of newly plastered surfaces all as specified and directed.
M&L preparation of old plastered surfaces of walls and applying one coat of cement base paint all as specified and directed.
M&L preparation of old plastered surfaces of walls and applying two coats of whtie wash all as specified and directed.
M&L preparation of old painted steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coats of synthetic enemel paint all as specified and directed.
M&L preparation of old painted wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coats of synthetic enamel paint all as specified and directed.
Taking down shutters of any description exc 1Sqm but n.exc 2 Sqm all as specified and directed.
Taking down chowkat or frames with shutter (without taking off shutters from the frame) exc 1.5 sqm but n.exc 4 Sqm all as specified and directed.
S&F solid PVC door frame at size 50 mm x47mm made out of 5 mm plain colour PVC sheet reinforced with M.S Square tube all as specified and directed.
S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side colour PVC shet to be fitted in the M.S frame selded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement fixed to frame all as specified and directed.
S&F second class hard wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chemfered, put together with glue pinned at joints all as specified and directed.
S&F 30 mm thick 2nd class hard wood Glazed and skelton shutters, open rebated and prepared to receive glass, gauze, etc., (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing galss, etc., size of member of shutters as specified in SSR Pt-I, section 8, clause 8.24 (a) all as specified and directed.
S&F 3.0 mm thick sheet glass ordinary quality and glazing with oil putty in square n.exc 0.5 sqm in each pane all as specified and directed.
M&L for cutting into existing manholes for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round 3/4 section) in cement concrete (1:2:4) type B-1, finished smooth and reforming benching as required for 150mm dia of pipe complete all as specified and directed.
Demolition and breaking up drain pipes 150 mm bore (Salt glazed ware, AC or Reinforced concrete) set in cement mortar all as specified and directed.
Excavation in trenches in n.exc 1.5 m wide and n.exc 1.5 m depth hard/dense soil for foundations, laying pipes, drains or manholes etc, n. exc. 10 sqm on plan and n. exc. 1.5 m depth, and getting out including trimmings sides and forming bottom surfaces to required level/slope etc, complete all as specified and directed.
M & L for Concrete bed 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) to 150 mm bore drain pipes including packing under, and completely surronding pipes after they are laid and tested; complete all as specified and directed.
M & L for 150mm internal dia Salt Glazed stoneware drain pipes laid in trenches and jointed as specified and directed
Returning filling including spreading levelling watering and well ramming in layers not exceeding 25 cm complete all as specified and as directed.
Removing excavated material, exc 1.5 KM and n. exc 5 KM and depositing where directed at a level n. exc 1.5M above the starting point outside MD land complete all as specified and as directed.
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
M&L precast cement concrete 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in block masonry with solid blocks, exc 10 cm in width and setting in mortar complete 1:4 complete all as specified and as directed.
M&L for pre-cast RCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in manhole cover slabs, set in cement morter 1:4 including necessary form work complete all as specified and as directed.
M&L rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 incl finished the surfaces even and smooth (without using extra cement) all as specified and as directed.
S&F mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (anealed) not less than 0.9 mm dia or securing with clips all as specified and as directed.
Disconnecting existing tanks exc. 500 litres and n. exc. 1000 litres , seting aside (or lowering if reqd) for repairs cleaning etc. and hoisting if required, and reconnecting and refixing in position all as specified and as directed.
cleaning and removing all dirt and scale etc. from tanks and mouths of circulating pipes etc. all as specified and as directed.
S&F 20 mm bore ball valves in repair high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed, (Min wt 210 gms) all as specified and as directed.
S&F in repairs 1000 Ltr rotational moulded poly-ethylene water tanks (cylindrical vertical with closed top) hoisted and fixed in position including dismantling of existing water tank all as specified and as directed.
Cutting holes into or through brick walls built in cement mortar for superficial area exc 150 sq cm but n exc 400 sqcm all as specified and as directed.
Roughning surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc & brushing neat cement slurry with 3.0 Kg of cement per sqm complete all as specified and as directed.
M&L 100 mm thick cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggt) as in floor finish spike rolling to surfaces or making impression of expanded metal complete all as specified and as directed.
Forming 20 mm thick expansion joints filled with preformed bituminous filler & top 30 mm premixed & sealed with sealing compound grade 'A' in 100 mm thick concrete slab complete all as specified and as directed.
S&F chequered cement concrete tiles 20 cm x 20 cm x 25 mm thick with grey cement and pigments, set, jointed and pointed in neat cement slurry in floors over and including 20 mm thick screed bed in cement mortar 1:6 all as specified and as directed.
M&L 75 mm thick cement concrete type C-2 1:3:6 (using 40 mm graded crushed stone aggregate), as in sub base of floors all as specified and as directed.
Demolition of cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground floor) including removing the debris out side MD land complete all as specified and as directed.
Excavating in post holes (or similar holes ) each n.exc. 0.5 cum getteting out returning filling in and ramming earth or broken rubble mixed with earth round in layers n.exc. 25 cm in soft / loose soil complete all as specified and as directed.
M&L for cement concrete 1:3:6 type C-2(using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete all as specified and as directed.
S &F for steel work in tubular trusses, posts, purlins including special shaped washer etc complete using ERW or induction butt welded tubes confirming to IS 1161-1998 grade St-240 all as specified and as directed.
S&F rolled mild steel joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc (cut to ordinary lengths i.e. within 20 mm of the length indicated) conforming to Fe 410-W- (Gde-E-250) quality-A all as specified and as directed.
S & F mild steel plates (plain or corrugated) channes, square cut or notched (ordinary and counter sunk) foming holes, without any attachments conforming to Fe410-W (gde E-250) quality-A all as specified and as directed.
S & F 0.50 mm thick prepainted galvalume aluminium zinc coating GI based corrugated steel steel sheet of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws all as specified and as directed.
All as per item No. 90 above but plain sheet as in ridges all as specified and as directed.
M & L raking cutting and waste or straight cutting and waste to stacks, sky lighting exc 0.4sqm all as specified and as directed.
M&L prepration of new or previously untreated steel surface of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide all as specified and directed.
S & F Mild steel Eaves gutter 1mm thk 150mm dia , galvanised class 3 half round with round edges all as specified and as directed.
S & F Mild steel Angles (internal & external) or Nozzles dia 150mm , 1mm thick all as specified and as directed.
S & F Mild steel Angles Drop ends for 150mm dia, 1mm thick all as specified and as directed.
S & F Mild steel Angles Stop ends for 150mm dia, 1mm thick all as specified and as directed.
Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out in any type of soil all as specified and as directed.
S&F coloured non skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white cement or coloured cement to match over and including 15 mm thick screed bed in cement mortar 1:6 all as specified and as directed.
S&F mild steel bands, straps, supports or stayes for rainwater vetilatoring pipes, incl bolts If rewd hooks (stay) heavy, for large gates hook and pintle hinges, heavy for large hasps and staples chains hand made sliding bolts clamps hold fasts wall ties hooks for hanging fans plain angles cleats for securing purlins to wood trusses or rafters knee piece inserts; two way and three way straps, plate washers and similar small articles confirming to Fe-190, Gde-E-165 all as specified and as directed.
S&F 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in walls complete all as specified and as directed.
S&F 75 mm bore PVC (SWR) bends any radius all as specified and as directed.
S&F 11 to 15 mm diameter of neck mild steel screw bolts (machine made) with hexagonal or square heads at one and screwed the other, or screwed both ends, each screwed and to be fitted with washers and one hexagonal or square but length of bolt exc 10 cm but n.exc 15 cm long all as specified and as directed.
Labour only for holes drilled dia of holes exc 12mm and n exc 25mm and depth of holes exc 3mm but n exc 12mm all as specified and as directed.
Dismantling cement (corrugated, semi corrugated etc,) sheets in roof covering all as specified and as directed.
Dismantling wrought iron or mild steel works of any description not otherwise provided all as specified and as directed.
Dismantling boarding, any description, fixed any position with nails all as specified and as directed.
S&F Techno T-Grid Ceiling suspension system using M S hot dip sections of main runner size 32mm x 24mm x 3600mm; Cross Tee size 27mm x 24mm x 1200mm & 27mm x 24mm x 600mm, wall Angle of size 22 mmx 20mx 3050 mm, sheet thickness 0.30 mm, including panels of Techno Acoustic Mineral Fibre Square mineral tesured tiles suspension system, panels shall be of size 600mmx600mm x 12mm having noise reduction co-efficent 0.4-0.6 light reflection over 85 relative humidity 95% Grid system for fixing ceiling tiles shall comprise of Techno T-Grid suspension system, 24 mm web of main Tee runner suspended at an interval of 1200 mm centre to centre, 1200 mm cross tee attached between to main runners at every 600 mm and further 600 mm cross Tee interconnected between two 1200 mm cross tees and forming a grid system of 600mm x 600mm. The main tee shall be suspended by means of 2/2.5 mm wire or 4 mm G.I. rod from slab/roof. The suspension shall be provided at 1200 mm centre to centre and not more 450 mm from the wall. However, the suspension shall not be more than 150 mm distance from the spliced joints of the main tee, all as specified and directed. Make: NewAge/ Daiken/ Armstrong
M&L preparing newly surfaces of walls and applying two coat of distemper oil emulsion incl 2mm thick wall putty and priming plastered and other surfaces with chalk whiting on plastered surface complete all as specified and as directed.
M&L preparation of old plastered surfaces of walls and applying two coats of whtie wash all as specified and directed.
M&L preparation of old plastered surfaces of ceiling and applying two coats of whtie wash all as specified and as directed.
M&L preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
Removing Existing water proofing treatment, including bedding concrete etc complete, cleaning the surfaces with wire brushes, removing dust, foreign material ,scrubbing down with water and rubbish off the same beyond the Defence land all as specified and as directed.
Material and labour for 40mm thk PCC 1:2:4 type B0(using 12.5mm graded stone aggregate) for but on roof slab as required to fill up the undulations to maintain smooth slope all as specified and as directed.
Material and labour for PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) for filleting and benching, slightly rounded or chamfered on edges all as specified and as directed.
M & L cement concrete 1:2:4 type B-2 (using 40 mm graded crushed stone aggregate) in foundations, filling and mass concrete all as specified and as directed.
M/L PCC 1:2:4 type B1 using 12.5mm graged aggregate for coping complete all as specified and as directed.
M&L providing precast cement concrete 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) in landings, cover slabs (for manholes etc) chullah hoods, chajjas, water troughs, Reinforcement shall be measured separately complete all as specified and as directed.
S&F mild steel TMT bars 6 to 8 mm dia and over, cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (anealed) not less than 0.9 mm dia or securing with clips all as specified and as directed.
M&L 100 mm thick cement concrete type B-1, 1:2:4 (using 20 mm graded crushed stone aggregate), as in roof treatment etc. all as specified and as directed.
M &L providing cement concrete 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) in roof kerb or mud stops, rounded or chamfered complete all as specified and as directed.
S&F 110 mm bore PVC (SWR) bends any radius all as specified and as directed.
S&F anodised aluminium snap grid frame work for false ceiling, size of grid 605x605mm, complete all as specified and as directed.
S & F Hangers 6 mm dia G.I (upto 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long complete all as specified and as directed.
M&L 4mm thk non asbestos fibre cement building Boards fixed or laid in aluminium frame work in existiing ceiling all as specified and as directed.
S&F in repairs galvanised mild steel wire cloth, 0.56 mm nominal ida of wire and average width of aperature 1.18 mm and fixed with tinned tacks, or galvanised wire staples all as specified and as directed.
Taking down carefully the existing unserviceable batten/conduit/concealed type aluminium point wiring for light, fan, socket 5 Amps and15 Amps complete removing the same including fittings/fixtures and making good the disturbed surfaces of walls, floors, ceiling etc. all as specified and as directed.
Taking down unserviceable main switch/DB, Teak wood boards etc all as specified and as directed.
M&L for point wiring in concealed with PVC insulated, unsheathed, single core multistandard copper conductor cable( FRLS) of size 1.5 Sqmm, 1100 volts grade including 1.5 Sqmm PVC insulated, unsheathed, copper conductor cable for earth continuity wire to be drawn through in and including PVC conduit medium grade ISI marked with its acessories & pressed steel terminal boxes and providing 3 mm thick ISI marked laminated sheet cover and brass screws with cup washers for fixing switches / socket / regulators etc including all necessary wall cutting chases and making good disturbed surfaces in cement mortar 1:3 for One light/CB point controlled by one switch, complete all as specified and as directed.
All as per item No 129 above but for one Ceiling fan/Exhaust fan point controlled by one switch.
All as per item No 129 above but for one 3 pin 5 Amps socket outlet point on independent board
All as per item No 129 above but for one 3 pin 5 Amps socket point on the same board with other switches
All as per item no 129 here-in-before but with cable 2.5 sqmm including 2.5 sqmm cable as earth wire for 15/16 amp socket point all as specified and as directed.
M & L switch piano, flush type single pole, one way 5 Amps all as specified and as directed.
M&L switch socket combination 2 in 1, 3 pin 5 Amps flush type universal all as specified and as directed.
M&L switch socket outlet 2in1, 3pin,5A all as specified and as directed.
M&L switch socket combination 2 in 1, 3 pin 15 Amps flush type universal all as specified and as directed.
M&L ceiling rose surface bakelite 65x50 mm two to three terminals all as specified and as directed.
S&F MCB single pole, 240 volts 6 to 32 Amps all as specified and as directed.
S&F MCB single pole and neutral 32 Amps, 240 Volts all as specified and as directed.
S&F sheet metal enclosure (for DB's when MCBs to be used), single pole and neutral Double door, 12 way, 240 Volts all as specified and as directed.
Supply and fixing LED lights fiting 1x20 Watt, 220v,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
Supply and fix exhaust fan, steel body AC single phase. 230 V of size 300 mm sweep with, blades, and frame and louvers all as specified and as directed.
MCCB 4 pole, 415 V, adjustable type , 160 Amps with breaking capacity 36 KA with sheet metal enclosure complete all as specified and as directed.
S&F VTPN MCCB 250A DB-Double door made out of CRCA mild steel sheet flushed in wall, TPN 12 way with 200 Amps rated bus bar , 415 volts IP-54, with PVC MCB blanking plates, stove enamelled, dust and vermin proof suitable for incorporation of MCB's and isolators etc including complete all as specified and as directed.
Supply & fix Led Street light 25 watt with pressure die - cast housing along with prismatic poly carbonate diffuser and LEDs with secondary optics and IP 65 protection complete with all accessories including connecting up with twin core twisted flexible copper conductor cable of suitable size 24/0.2mm and taking down old unserviceable Street light fitting complete all as specified and as directed .
M & L earthing complete with GI earth plate Electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth plate not less than 2.25 Metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanished earth wire 4.0 mm dia by means of bolts, nuts check and washers of GI or steel all as shown in electrical plate No. 3 of SSR Pt -I connected to earthing test point all as specified or indicated including GI pipe 15 mm dia light grade for earth wire protection, necessary excavation, earth work in any type of soil, PCC chamber and RCC cover slab, connecting lead wire from test point to DB complete all as specified & as directed
Removal of surplus soil not exceeding 30 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point.
M & L clean dry sand laid in trenches/duct for cushioning to cablle complete all as specified and as directed.
Supply and lay burnt bricks of class 'B' laid dry across in trenches for cable protection.
Supply , laying and testing cable XLPE Insulated , screened , PVC bedded , galvanized steel strip or wire armoured , electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sq mm 4 Core.
Charms Engineers Inc
SREE CONSTRUCTIONS
PRIYADARSHINI CONSTRUCTIONS
S.N.MANJUNATHA
RAMSON TRADERS
S SUDHAKAR
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .