| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.6 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹37.2 L+₹3.0 L (8.63%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹37.9 L+₹3.6 L (10.6%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹38.3 L+₹4.1 L (11.9%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹48.4 L+₹14.2 L (41.4%)Rejected-Finance | L5 | Rejected-Finance Being L5 |
Tender Value
₹57.2 L
EMD Value
₹1.1 L
Closing Date
4 Aug 2020, 6:00 pmClosed
CWE (AF) Palam Delhi Cantt-10
HQ CWE (AF) Palam Delhi Cantt-10
SPECIAL REPAIRS TO BUILDING NO P-118 AT SUBROTO PARK UNDER GE (AF) SUBROTO PARK DELHI CANTT-10
2020_MES_357004_1
CA NO CWE/PM/SP-05/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Subroto Park Delhi Cantt
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
GE (AF) Subroto Park
₹1.1 L
Yes
26 Aug 2020
30 Jun 2020
6 Aug 2020
30 Jun 2020
4 Aug 2020
21 Jul 2020
Amount
BOQ PART-I (B/R WORKS)
Demolition of cement concrete including brick tiles/APP membrane of any description and in any position not otherwise specially provided for including removal of same to a distance of 15 km (outside MOD land) complete, all as specified and directed by Engineer-in-Charge.
M&L for preparation of plastered/concrete surfaces of roof and applying the under mentioned course of roof treatement complete, all as specified and directed by Engineer-in-Charge.:- (a) Surface shall be throughly wire brushed, cleaned, washed, dried up properly and apply evenly a bituminuous primer coat conforming to IS @0.4 ltr /Sqm over concrete / plastered roof surface. (b) Applying evenly a tack coat of bitumen 85/25 grade @1.20 kg/ sqm. (c) Laying of 3mm thick APP membrane sheet (min weight 3 Kg/Sqm) consisting of a core of 160 gms/Sqm polyster non woven fabric mat protected on both sides with a high quality polymeric asphaltic mix again protected with thermo fusible HMHDPE FILM on dried primed surface by torch application method. APP membrane will normally be laid in length at right angle to the direction of slope. The over lap shall be minimum 100mm on longitudinal direction and 150mm on the transverse direction including cuttings, grooves etc. (d) Membrane bonded completely to the substrate & the over laps are then scaled/fused by flame. Note:- This treatement shall be done by the approved authorized applicators and guarantte of treatement shall be for 10 years.
Supply only liquid water proofing compound ISI marked complete, all as specified and directed by Engineer-in-Charge.
M & L for PCC 1:2:4 type B1 (20mm graded stone aggregate) as in levelling course over RCC roof surfaces complete, all as specified and directed by Engineer-in-Charge.
M & L for PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in roof curbs, benching rounded or chamferred on edge including rounded or chamfered edges with necessary form work etc complete, all as specified and directed by Engineer-in-Charge.
M&L 10 mm thick screed bed or bedding layer in cement mortar 1:6 with liquid water proofing compound complete, all as specified and directed by Engineer-in-Charge. Note : Liquid WPC shall be measured and paid separately.
M&L for cement concrete tiles 20 cm x 20 cm x 20 mm thick with grey cement and no pigment machine pressed; set jointed and pointed in neat cement slurry, and cut and polished complete, all as specified and directed by Engineer-in-Charge.
Taking down cement plaster etc on brick wall or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc and disposed off unserviceable materials to out side MOD land complete, all as specified and directed by Engineer-in-Charge.
M &L for rendering 15mm thick on other than fair faces of brick work or concrete surfaces in CM 1:4 mixed with water proofing compound as per manufacturer instruction even and fair without using extra cement complete, all as specified and directed by Engineer-in-Charge. Note :- Water proofing compound shall be measure and paid separatelly).
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 of walls finished even and fair without using extra cement complete, all as specified and directed by Engineer-in-Charge.
M&L for rendering 5 mm thick with cement mortar 1:3 on concrete surfaces of ceiling, soffit of stair case, chajjas facia etc including finished even and fair without using extra cement complete, all as specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete, all as specified and directed by Engineer-in-Charge.
S&F non - skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in cement mortar 1:4 as in floor finishes complete, all as specified and directed by Engineer-in-Charge.
S&F glazed ceramic coloured tiles in vertical surface 350x 250x 7 mm or 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match 10mm thick screed bed in cement mortar 1:4 complete, all as specified and directed by Engineer-in-Charge.
M&L vitrified Ceramic light shade tiles 9 to 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match flooring( in any pattern) and jointed with neat cement slurry over 15 mm thick cement screed in cement mortar 1:6 and pointed with coloured cement matching with surfaces of tiles as in floor complete, all as specified and directed by Engineer-in-Charge.
All as per item No 1.15 here-in-before but as in skirting including 10 mm thick backing coat in cement mortar 1:4.
M&L vitrified Ceramic dark shade tiles 9 to 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match flooring( in any pattern) and jointed with coloured cement matching with surfaces of tiles as in floor 15 mm thick cement screed in cement mortar 1:6 and pointed with coloured cement matching with surfaces of tiles as in floor complete, all as specified and directed by Engineer-in-Charge.
M&L polished machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete incl Screed bed 15 mm thick in cement mortar 1:6 for laying floor finishes complete, all as specified and directed by Engineer-in-Charge.
All as per item No 1.18here-in-before but as in skirting over 10mm thick screed bed in cement mortar 1:4
Demolition of cement concrete of any description and in any position not otherwise specifically provided for including removal of same to outside MOD land (approx 25 to 30 km) complete, all as specified and directed by Engineer-in-Charge.
M&L 75mm thick cement concrete type C- 2, 1:3:6 (40mm graded stone ggregate) as in plinth protection complete, all as specified and directed by Engineer-in-Charge.
Demolition of brick work or stone/boulder masonry built in cement mortar complete, all as specified and directed by Engineer-in-Charge.
M&L for brick work with sub class ‘B’ bricks having curshing strength @ 75 Kg/Cm2 straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete, all as specified and directed by Engineer-in-Charge.
Taking up or down 15mm bore steel tubing and connections, including cleaning for re- fixing or removal to store complete, all as specified and directed by Engineer-in-Charge.
All as per item No 1.24 here-in-before but 20 mm dia
S&F 15 mm bore steel tubing galvanized medium grade with all fittings and fixed concealed to walls and ceiling or laid in floors complete, all as specified and directed by Engineer-in-Charge.
All as per item No 1.26 here-in-before but 20 mm dia
S&F as in repairs, 20mm dia gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete, all as specified and directed by Engineer-in-Charge.
Dismantling water tanks exc 250 but not exc 500 Litres, and removing to store complete, all as specified and directed by Engineer-in-Charge.
All as per item No 1.29 here-in-before but exc 500 but not exc 1000 Litres
Disconnecting existing tanks exc 250 but not exc 500 Litres, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc complete, all as specified and directed by Engineer-in-Charge.
All as per item No 1.31 here-in-before but exc 500 but not exc 1000 Litres
S&F rotational moulded polyethylene water tank (Tripple layered, white in colour) 500 ltr capacity (cylindrical vertical with closed top) hoisted and fixed complete, all as specified and directed by Engineer-in-Charge.
S&F rotational moulded polyethylene water tank (Tripple layered, white in colour) 1000 ltr capacity (cylindrical vertical with closed top) hoisted and fixed complete, all as specified and directed by Engineer-in-Charge.
S&F as in repairs, 15 mm angular stop cock chromium plated and fancy type with crutch or butter fly handle with CP wall flange high pressure screwed down of complete, all as specified and directed by Engineer-in-Charge. Make- CON-041KN of Jaquar or equivalent.
S&F as in repairs, CP waste coupling 32mm size half threaded with 130mm height complete, all as specified and directed by Engineer-in-Charge. Make-ALD-709 of Jaquar or equivalent.
S&F as in in repairs, CP bottle trap with internal partition 32mm size 300 mm x 190 mm with wall connection pipe and wall flange complete, all as specified and directed by Engineer-in-Charge. Make-ALD-769 L of Jaquar or equivalent.
S&F as in repairs, hand shower( health faucet )with with 1.0 m long easy flex tube in chrome finish and wall hock complete, all as specified and directed by Engineer-in-Charge. Make-ALD-CHR-565 of Jaguar or equivalent.
S&F as in repairs, wall bracket of hand shower complete, all as specified and directed by Engineer-in-Charge. Make-SHA-555 of Jaguar or equivalent.
S&F as in repairs, CP towel ring complete, all as specified and directed by Engineer-in-Charge. Make-AQN-7721 of Jaguar or equivalent.
S&F as in repairs, CP Towel rail 450mm long complete, all as specified and directed by Engineer-in-Charge. (Make : ACN-1111BNM)
S&F as in repairs, CP Soap dish complete, all as specified and directed by Engineer-in-Charge. Make-AQN-7733 of Jaguar or equivalent.
S&F as in repairs, CP paper holder of complete, all as specified and directed by Engineer-in-Charge. Make-AHS-1553 of Jaguar or equivalent.
S&F as in repairs, concealed stop cock 15 mm bore with adjustable wall flange complete, all as specified and directed by Engineer-in-Charge. Make : CON-069 of Jaguar or equivalent.
S&F as in repairs, single lever basin mixer with popup waste system and 450 mm long braidaed hoses chromium plated for pipes etc incl CP wall flange complete, all as specified and directed by Engineer-in-Charge. Make- ORM-10051 B of Jaguar or equivalent.
S&F as in repairs, CP bib cock 15 mm bore with wall flange, fancy type long body complete, all as specified and directed by Engineer-in-Charge. Make : CON-047KN of Jaguar or equivalent.
S&F as in repairs, pillar cock, cast copper alloy, chromium plated, fancy type for 15mm bore pipe complete, all as specified and directed by Engineer-in-Charge. Make : CON-011KN of Jaguar or equivalent.
S&F for 15mm bore PVC connection 450mm long with brass nuts on both ends complete, all as specified and directed by Engineer-in-Charge.
S&F counter top oval wash basin, Size - 450 x 400mm incl waste coupling & PVC waste pipe. complete, all as specified and directed by Engineer-in-Charge. Make : Jaguar or equivalent.
S&F as in repairs, corner glass shelf with bracket complete, all as specified and directed by Engineer-in-Charge. Make-ACN-1173 of Jaguar or equivalent.
S&F as in repairs, stainless steel sink with drainage board made out of 1mm thick sheet for kitchen or laboratory with plug, washer, waste etc including cast iron brackets, connecting union over all size 915mm X 460mm with bowl size 410mm X 330mm X 160mm complete, all as specified and directed by Engineer-in-Charge. Make : Neelkamal/Diamond/Summer.
S&F Stainless steel plate rack of approved make, size not less than 900x750x200mm and weight not less than 7.00 kgs each complete, all as specified and directed by Engineer-in-Charge.
S&F as in repairs, viterious china wash down water closet pan (Pedestal pattern) white (excluding fixing bolts, flushing cistern and flush pipe)incl P or S trap etc complete, all as specified and directed by Engineer-in-Charge.
S&F as in repairs, plastic water closet seat cover, white, closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device complete, all as specified and directed by Engineer-in-Charge.
S&F as n repairs, vitreous china water closet Squatting Orissa patern white size 580 x 440mm with integral foot rest with 100mm 'P' or 'S' trap complete, all as specified and directed by Engineer-in-Charge.
S&F as in repairs,10 ltr capacity PVC flushing cistern white with accessories Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern ISI marked complete, all as specified and directed by Engineer-in-Charge.
S&F as in repairs, vitrious china urinals including all necessary fittings etc complete, all as specified and directed by Engineer-in-Charge. Make- Jaguar cat Part No- URS-WHT-13261 or equivalent.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete, all as specified and directed by Engineer-in-Charge.
S&F PVC (SWR) pipes 110 mm single socketed, in any length with solvent cement joints fixed to walls incl stack clamps of stainless steel with bolts & nuts etc complete, all as specified and directed by Engineer-in-Charge.
S&F PVC SWR floor trap with grating including jointing with solvent cement 75 mm dia complete, all as specified and directed by Engineer-in-Charge.
S&F PVC SWR bends 110 mm dia complete, all as specified and directed by Engineer-in-Charge.
S&F PVC SWR bends 75 mm dia complete, all as specified and directed by Engineer-in-Charge.
S&F PVC SWR Branch piece 75 mm double (Double T) provided with access door equal or unequal complete, all as specified and directed by Engineer-in-Charge.
S&F 110 mm PVC SWR Junction single (Single T) provided with access door complete, all as specified and directed by Engineer-in-Charge.
S&F PVC SWR vent cowl of size 110 mm complete, all as specified and directed by Engineer-in-Charge.
S&F PVC SWR vent cowl of size 75 mm complete, all as specified and directed by Engineer-in-Charge.
Taking down Chowkhats or frames with shutters without taking off shutters from frames exceeding 1.50 Sqm but not exceeding 4.00 Sqm complete, all as specified and directed by Engineer-in-Charge.
All as per item No 1.68 here-in-beofre but not exceeding 1.50 sqm
Taking down door shutters of any description exc 1 Sqm but n exc 2 sq. m each and refixing in same opening complete, all as specified and directed by Engineer-in-Charge.
S&F in repairs for double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete, all as specified and directed by Engineer-in-Charge.
S&F aluminium frame powder coated any colour (minimum thickness of powder coating 50 micron) for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete, all as specified and directed by Engineer-in-Charge.
S&F aluminium frame powder coated any colour (minimum thickness of powder coating 50 micron) window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete, all as specified and directed by Engineer-in-Charge.
S&F 5.5mm thick ordinary quality tinted sheet glass and glazing in square n.exc 0.50 Sqm each fixed with PVC /Neoprene gasket in aluminium frame work complete, all as specified and directed by Engineer-in-Charge.
S&F Solid PVC door frame of size 50mm x 47mm made out of 5mm wood grain printed PVC sheet & edges will be painted to match with printed sheet reinforced with M.S Square tube, in opening as per specification & drawing complete, all as specified and directed by Engineer-in-Charge.
S&F factory made solid PVC moulded door shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick 3D wood grain Moulded PVC Sheet Polyurethane painted on the front face & 2mm prelam PVC Sheet on back face with wood free EPS complete, all as specified and directed by Engineer-in-Charge.
Dismantling of ceiling /wall panelling including frame work and board complete, all as specified and directed by Engineer-in-Charge.
M&L preparation of new plastered surfaces of walls and applying two coats of exterior acrylic emulsion paint premium quality over a coat of primer incl two coats of wall care putty to achive smooth surface on walls complete, all as specified and directed by Engineer-in-Charge.
M&L complete removal existing treatment including washing, rubbing down and stopping of white wash or cement based paint and applying two coats of exterior acrylic emulsion paint premium quality over a coat of primer complete incl two coats of wall care putty to achive smooth surface on walls complete, all as specified and directed by Engineer-in-Charge.
M&L for preparation of newly plastered surface and applying two coats of distemper oil emulsion on walls over a coat of primer incl two coats of wall care putty to achive smooth surface on walls complete, all as specified and directed by Engineer-in-Charge.
M&L for complete removal of existing treatment of wall, washing down with water and applying two coats of distemper oil emulsion over a coat of primer incl two coats of wall care putty to achive smooth surface on walls complete, all as specified and directed by Engineer-in-Charge.
M&L preparation of newly plastered or unplastered surface and applying three coats of white wash on ceiling / soffits complete, all as specified and directed by Engineer-in-Charge.
M&L Preparation of old wooden surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint complete, all as specified and directed by Engineer-in-Charge.
M&L Preparation of old steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint complete, all as specified and directed by Engineer-in-Charge.
M&L for gunniting work to RCC work in columns beams, chajja, balconies, slabs landing etc by removing loose concrete, incl removing rust with short blasting and Cleaning of surface with wire brush and applying epoxy treatment to rusted reinforcement and including S&F welded wire mess fabric or wire not less than 95x95x3mm adhesive plaster grade for concrete admixture and providing gunniting pressure 2.00/2.50 Kg/ Sq cm with admixture 1 Part of cement and 3.50 part of sand and thickness 50mm average and making the surface even and smooth including necessary form work and 10mm thick plaster over repaired surface upto 4 storeys building complete, all as specified and directed by Engineer-in-Charge.
M&L for PVC profile for wall paneling colour/shade as approved size 250mm wide, 08 mm over all thick with 1 mm wall thickness fixed with screw to mild steel square (size 20mm x 20mm x 1mm thick) tubler frame work including one coat of red oxide primer, fixed to walls complete, all as specified and directed by Engineer-in-Charge.
S&F M&L for PVC profile corner beading L/T type for wall panelling, colour/shade matching with wall panelling complete, all as specified and as directed by Engineer-in-charge.
M&L for false ceilings using GI snap grid system with roll-formed out of hot dip galvanized steel caping (powder coated) main runner 38mm x 24mm, cross tee 29mm x 24mm and wall angle 24mm x 24mm members suspended with 4mm dia GI wire, carry maximum load upto 8.10 Kg/Sqm with 4mm thick designer ceiling board, pre-painted cement fibre board size 595mm x 595mm x 4mm thick any texture (Lake and Hill, oceaniccascade or Electra) as approved by Engineer-in-Charge all as per Everest Ceiling grid system "Regular T-2430" or its equivalent make of "Ramco, Charminar/Armstrong" at any height complete, all as specified and directed by Engineer-in-Charge.
BOQ PART-II (E/M WORKS)
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc removing materials and keeping in safe custody for giving credit and making good disturbed surfaces of walls, floors etc complete, all as specified and directed by Engineer-in-Charge.
M & L for point wiring for following types of electrical points with two runs of FRLS PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of size 1.5 Sqmm drawn through medium grade PVC conduit pipe not less than 1.2 mm thick and not less than 20mm dia concealed in wall/ surface in ceiling including provision of pressed steel terminal boxes of suitable size with 2.8mm thick plastic laminated sheet cover for mounting switches, sockets and regulator alongwith continous earth wire of PVC insulated, unsheathed, 1100 V grade cable multi stranded copper conducotr of size 1.5 Sqmm complete, all as specified and directed by Engineer-in-Charge. Note : Cost of cutting chasing and making good to disturbed surface to match with existing surface are deemed to be included in quoted rate). (a) One light point controlled by one No one way single pole switch.
All as per item No 2.02 here-in-before but for one ceiling fan/exhaust fanpoint controlled by one number one way single pole switch.
All as per item No 2.02 here-in-before but for one 5 pin 5 Amps socket outlet on independent board.
All as per item No 2.02 here-in-before but for 3 pin 5 Amps socket outlet on the same board with other switches
All as per item No 2.02 here-in-before but with 2.5 Sqmm cable for independent board one 3 pin 15 Amps socket outlet incluidng single core 2.5 Sqmm PVC insulated copper conductor unsheathed 1100 V grade IS : 694 FRLS cable for continuous earth wire connected to gang box of required size.
S&F switch piano, flush button, single pole, one way, 5 Amps, 230 Volts complete, all as specified and directed by Engineer-in-Charge.
S&F switch piano 16 Amps flush type single pole one way complete, all as specified and directed by Engineer-in-Charge
S&F socket outlet flush type 5 pin 6 Amps complete, all as specified and directed by Engineer-in-Charge.
S&F socket outlet 2 in 1, 5 pin 16 Amps flush type complete, all as specified and directed by Engineer-in-Charge.
Supply and connecting rottary step type fan regulator suitable for 240 Volt complete, all as specified and directed by Engineer-in-Charge.
M&L for submain wiring with under mentioned runs of single core PVC insulated but unsheathed FRLS cable of specified size with multistranded copper conductors 1100 volt grade IS-694 marked drawn through and including non metalic PVC conduit pipe medium grade ISI marked (not less than 20mm dia) alongwith fittings and accessories all fixed concealed on wall and surface on ceiling and also including the specified runs of specified size earth continuity conductor of similar type of cable complete, all as specified and directed by Engineer-in-Charge. (a) 2 run of 4 Sqmm cable and one run of 4 Sqmm cable. Note :- 2 runs of main cable one run of earth wire one run of PVC pipe will be measured as an one run.
(b) 2 run of 6 Sqmm cable and one run of 6 Sqmm cable
Taking down carefully copper/aluminium surface/conduit submain wiring from main DB to sub DB and keeping in safe custody for giving credit and making good disturbed surfaces or wall, floors etc complete, all as specified and directed by Engineer-in-Charge. (a) 2 run of 4 Sqmm cable and one run of 2.5 Sqmm cable.
(b) 2 run of 6 Sqmm cable and one run of 4 Sqmm cable
Taking down of tube light fittings/ceiling fittings/wall fittings/holder fittings of any type and make and removing materials to store for keeping in safe custudy or for reuse or taking credit and making good disturbed surface of walls, floors etc complete, all as specified and directed by Engineer-in-Charge.
S&F of recess/pendant mounting ultraslim 36 watt 2 x 2 LED flat panel made of extruded aluminium frame with high efficient/brightness LED & glare free opal diffuser, IP20 complete, all as specified and directed by Engineer-in-Charge. Make : Havells Cat No ENDURASLIMPROPLUS2X2PLR28/36WLED857MOD or its equivelant in Wipro/Philips.
S&F surface mounting LED slim round down lighter made of PDC with high efficient LED & glare free opal diffuser IP20, 22 watt 4000 K complete, all as specified and directed by Engineer-in-Charge. Make : Havells Cat No GLOWDLS15WLED840S or its equivelant in Wipro/Philips.
S&F in replacement of indoor decorative wall mounted LED batten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver 20 watt LED fitting, 230 Volts, diffused optics etc complete with all accessories, connecting up with twin core twisted flexible copper conductor cable from celing rose to fitting, fixed on two PVC round blocks and testing complete, all as specified and directed by Engineer-in-Charge. Make : Havells Cat No LUMILINEPLUSBS20WLED865SPCSS or its equivelant in Wipro/Philips.
S&F ceiling rose polycarbonate, isolated body 65 x 50 mm, 2 to 3 terminal complete, all as specified and directed by Engineer-in-Charge. Make : Anchor Pentra PC/Havells/Cona.
S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 240 VoltsMCB 20 Amps complete, all as specified and directed by Engineer-in-Charge.
Taking down unserviceable single pole and neutral enclosure with two pin and earth plug after disconnecting the electric supply complete, all as specified and directed by Engineer-in-Charge.
Taking down ceiling fan of any size/sweep and hanging the same back after servicing greasing and painting including connecting the wire to ceiling rose etc complete after completing the wiring complete, all as specified and directed by Engineer-in-Charge.
Hanging only ceiling fan received from item No 2.23 here-in-before and connecting up including provision of suitable size of copper cable from connector of fans to ceiling rose complete, all as specified and directed by Engineer-in-Charge.
S&F ceiling fans 1200mm sweep, 5 star rating, 230 Volts, SP with all accessories including provision of MS hooks suitable for hanging ceiling fans and suitable size and length of copper wire and down rod complete, all as specified and directed by Engineer-in-Charge.
Taking down and disconnecting of old unserviceable LT panel of any type and size including MCCB and MCBs for taking credit (credit for above items should be made as per conditioned separately) and making good disturbed surface of walls, floors etc complete, all as specified and directed by Engineer-in-Charge.
Supply, installing, testing and commissioning factory made and tested (CPRI Test certified) LT feeder pillar box outdoor type, platform mounted suitable for 3 phase 4 wire, 50 Hz, AC supply system base bus bar chamber with insulated AC/copper busbar 500 Amps (3 Nos) phase and 400 Amps for neutral rating installed on porcelain insulator. The panel shall be dust and vermin proof IP65 class protection and made out of 3.15 mm thick CRCA MS sheet and 50 mm x 50 mm x 6 mm thick angle iron frame works, powder coated finish over one coat of red oxide primer on outside and two coats of red oxide primer inside, front opening type with approns for cable ending with double door shutter and locking arrangement (including provision of 65 mm Godrej (freedom) lock with 2 keys, insulated copper conductor FRLS IS-699 marked 1100 volts grade but sheathed cable adequate size but not less than 4mm size complete, all as specified and directed by Engineer-in-Charge. (a) Incoming (i) MCCB 320 Amps, 4 pole, 36 KA Make : Legrand/Schneider/ABB -01 No. (ii)Digital type Voltmeter 0-500 Volt size 96 Sqmm with 3 way slector switch -01 No.
Supply, laying, jointing, testing LT cable 25 Sqmm 4 core, 1100 Volts grade, PVC insulated armoured and PVC sheathed with stranded aluminium conductor heavy duty including cable glands, cable lugs etc to suit the cable size, laid in trenches, fixed along the poles bare or through GI pipe laid under floors road etc fixed concealed in walls encased in GI pipe etc complete, all as specified and directed by Engineer-in-Charge.
Supply, laying, jointing, testing LT cable 70 Sqmm 3.5 core, 1100 Volts grade, PVC insulated armoured and PVC sheathed with stranded aluminium conductor heavy duty including cable glands, cable lugs etc to suit the cable size, laid in trenches, fixed along the poles bare or through GI pipe laid under floors road etc fixed concealed in walls encased in GI pipe etc complete, all as specified and directed by Engineer-in-Charge.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in deep for foundation of pole/stay/cable etc and getting in soft/loose soil complete, all as specified and directed by Engineer-in-Charge.
Returning, refilling including spreading, levelling, watering and well ramming in layers each not exceeding 25 cm thickness complete, all as specified and directed by Engineer-in-Charge.
Removing surplus spoil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 m above the starting point complete, all as specified and directed by Engineer-in-Charge.
M & L for sand cushioning using fine sand (Jamuna dry and clean sand) in two layers, first layer of 80mm thick before laying of cable and second layer of 150mm thick (Punned down to 100 mm thcik) after laying of cable complete all as specified and directed by Engineer-in-Charge. Note : 180 mm thickness only will be considered for the purpose of payment.
Supply and lay well burnt sub calss 'B' bricks as mechanical protection to under ground cables laying with length of the bricks equal to the width of the trench complete, all as specified and directed by Engineer-in-Charge.
Supply and laying GI tubing light grade of size 80mm dia with all fitting for protecting the cables in trenches, floors, on poles, in walls complete, all as specified and directed by Engineer-in-Charge.
Hindustan Co.Co
Rishi Constructions
M/S MG GROUP
Ashish Sehgal and Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .