| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹16.0 L+₹52,320 (3.39%)Rejected-Finance | L2 | Rejected-Finance L2 FOR REJECTED | |
| 3 | Rejected-Technical | - | Rejected-Technical The firm is not Enlisted in Appropriate Category i.e. b(ii) | |
| 4 | Rejected-Technical 601 6TH FLOOR MANGOOR VALLEY NEAR GURUDWARA MANGOOR HILLL VASCO DA GAMA GOA 403 802 | SOUTH GOA | GOA | 403802 | - | Rejected-Technical The firm is not Enlisted in Appropriate Category i.e. b(ii) |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
24 Dec 2021, 6:00 pmClosed
CWE SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
CA NO CWE SGNR 51 Of 2021-22 REPAIR/MAINT TO UNDERGROUND OVERHEAD HT EXTERNAL ELECTRIFICATION SYSTEM ALONGWITH OTHER CONNECTED ITENS AT MIL STATION ABOHAR (2ND CALL)
2021_MES_481199_2
CA NO. CWE SGNR - 51 OF 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE ABOHAR
CLASS-E
CATEGORY b(ii)
10 documents required · 10 mandatory
₹500
₹30,000
Yes
4 Feb 2022
30 Nov 2021
27 Dec 2021
30 Nov 2021
24 Dec 2021
10 Dec 2021
Amount
Excavation in trenches not exceeding 1.5 mtr depth width and not exceeding 1.5m depth for laying under ground cable in loose/soft soil complete all as specified and directed by Engineer-in-charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and directed by Engineer-in-charge.
Removal of surplus soil obtained from excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-charge.
M&L for sand cushioning for protection of PVC cable with screen wash river sand and punning to proper required cover complete all as specified and directed by Engineer-in-charge.
M&L for PCC including cutting up to 45 cm width and depth of the road/hard standing and making good disturbed surfaces by using PCC type C2(1:3:6) by using 40mm graded stone aggregate for the fixing the pipe/laying cables complete all as specified and directed by Engineer-in-charge.
M&L for Boring hole across the Road/plinth/hardstanding/path/drain/pavement etc., suitable for inserting HDPE/GI pipe of upto 100mm dia bore pipe for cable passing without damaging existing Road/path/hardstanding/floor by manual using trenchless technology tools/necessary equipment ccomplete all as specified and directed by Engineer-in-charge.
S&F un-reinforced precast concrete cable cover class HVP type 1 with peak, size 300mmx180mmx40mm laid flat length of cover across the length of cable and old US PCC cover to be disposal off 100 mtr away from the site complete all as specified and directed by Engr-In-Charge.
Takng out old unserviceable under ground HT cable upto 185 sqmm from trenches/floor/road/pipe/ along poles including taking out old bricks complete all as specified and directed by Engineer-in-charge. Note: Excavation,earth work required for item shall be measured and paid seperately under respective items of BOQ.
Supplying, laying, jointing and testing of XLPE insulated, screened, PVC beded,galvanised steel strip or wire armoured,clectric power cables (heavy duty)with aluminium conductor HT cable 11000 volts earthed grade with cross sectional area 120 sqmm 3 core laid in trenches/ ducts/ along poles/ through pipes complete all as specified & directed by Engineer-in- charge. Note: Excavation & earth work shall be measured & paid separately under appropriate item of this Schedule.
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to galvanised iron earht strip 25x4mm thick fixed by means of bolts, nuts and washers of the earth wire galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 40mm dia upto 3m height above ground level and watering pipe 20mm dia GI medium grade with socket and plug 30 cm above ground level including earthwork, PCC chamber in PCC (1:3:6) type C-2 using 40mm stone aggregate, cast iron cover, wire meah etc all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 complete and all as specified and direcrted by Engr-in-charge Notes :- (i) 20 mm dia GI pipe for watering to be provided with a socket and plug and should be 30 cms above ground level. (ii) GI strip connecting upto pump,Gen set,LT panel and DBs earth connection is included in this item. (iii) GI pipe 40 mm dia protection pipe shall be provided upto Ground level.
M&L for cement concrete in foundations, filling and mass comcrete type D2 1:4:8 with 40 mm graded stone aggregate for foundation of pole etc complete all as specified and directed by Engineer-in-charge.
M&L for providing cement concrete type B1, 1:2:4 using 20 mm stone aggregate in foundation, roof,kerb or mud stops, rounded or chamfered on edges complete all as specified and directed by Engineer-in-charge.
Supply and errect steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts and screws all as specified type 410 SP - 55(11.0M Long) as per is-2713(Part-III)of 1980 and applied three coats of aluminium paintover a coat of zinc chrome primer to the exposed surfaces all as directed including dismentling complete all as specified and directed by Engineer-in-charge.existing pole . Note:Excavation and concrete shall be measured and paid separately.
M&L for fabrication of cross arms bracings supports,clamps and back plates,iron stainer, water gate, ladder for clear water tank etc as required structural steel section including nuts, bolts, washers, welding,bending, cold or hot, drilling holes for bolts in any shape or size and including of one coat of primer and one under coat and one finishing coat of paint complete all as specified and as directed by Engr in charge.
M&L for painting of old painted surfaces with synthetic enemel paint to HT steel tubbular pole 11 mtr long including clamps,brackets,chanels,cross arms,bracing support and supporting pipe of cables etc including zebra painting at bottom up to 1.5 mtr above from the PCC coping and writing pole No with white paint complete etc complete all as specified and directed by Engineer-in-charge.
All as per item No 15 herein before but for 4 pole structure including cross arm,bracings complete all as specified and directed by Engineer-in-charge.
All as per item No 15 herein before but for 2 pole structure including cross arm,bracings etc complete all as specified and directed by Engineer-in-charge.
S & F GI tube light grade galvanised of size 100 mm bore with all fitting and fixed to wall and celling or laid in floors/under road etc complete all as Specified and directed by Engineer-in- Charge.
S & F GI tube light grade galvanised of size 50 mm bore with all fitting and fixed to wall and celling or laid in floors/under road etc complete all asSpecified and directed by Engineer-in- Charge.
S & F GI tube light grade galvanised of size 80 mm bore with all fitting and fixed to wall and celling or laid in floors/under road etc complete all as Specified and directed by Engineer-in- Charge.
S&F in replacement of pin type,porcelain,vitreous,white,brown or green insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut, 150 mm height,150 mm dia for 11000 volts grade complete all as specified and directed by Engineer-in-charge.
S&F disc type insulator, porcelain,vitreous 150 mm high and 150 mm dia ball and socket type,white,brown or green 'Two in series' assembly for tension with tension clamps for conductors,suitable for working pressure 11000 volts grade complete all as specified and directed by Engineer-in-charge.
S&F in repair loop type insulator, vitrous porcelain, white brown or green large size with overall dimensions 90x140 mm clearance of hole 25.5 mm dia complete all as specified and directed by Engineer-in-charge.
S&F in replacement of galvanised stay wire with stay strand 7/4mm complete all as specified and directed by Engineer-in-charge.
Supply and fix stay assembly complete with accessories as shown electrical plate No. 1 of SSR Part I for HT poles with 20 mm dia stay rod complete all as specifed. Note: Loop type insulator excavation and concrete will be measured and paid seperately in relevant item of sch complete all as specified and directed by Engineer-in-charge.
Supply and fix in replacement of Aluminium conductor steel reinforced (ACSR) of required size or guage complete all as specified and directed by Engineer-in-charge.
Supply and fix Galvanised steel wire 3.15 or 4mm dia for earth wire complete all as specified and directed by Engineer-in-charge.
Supply and fix inreplacement of cradles,hexagonal/rectangular,fabricated with Galvanised steel wire 3.15 mm or 4 mm dia, for LT/HT guard wire and craddles of required size or span complete all as specified and directed by Engineer-in-charge.
Supply and fix Anti-climbing device; spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and directed by Engineer-in-charge.
Supply and fix Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified and directed by Engineer-in-charge.
S&F in replacement of HT 11 KV Air break switch, gang operated and drop out fuse unit having 12 Insulators for outdoor use, complete with all acessories, mounted on insulator and steel frame, with operating mechanism working from ground level, for current rating up to 200 Amps including GI pipe of suitable size,clamps,nuts,bolts amd washers etc complete all as specified and directed by Engineer-in-charge.
S&F in replacement of HT 11 KV Air break switch, gang operated and drop out fuse unit having 12 Insulators for out door use, complete with all acessories mounted on insulator and steel frame, with operating mechanism working from ground level, for current rating up to 400 Amps including GI pipe of suitable size,clamps,nuts,bolts amd washers etc complete all as specified and directed by Engineer-in-charge.
S&F in replacement of lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 Kilo amp suitable for 11000 Volts complete all as specified and directed by Engineer-in-charge.
S&F cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified.
S&F cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified.
S&F cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified.
S&F cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified.
S&F Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed.
S&F Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm. complete all as specified and directed.
M&L for cutting/trimming of branches of tree tuching/aproaching LT/HT over lines of various spans(having 40 to 45 mtr) up to 3 mtr width on each side from different site of grith up to 10 cm with cutting equipments hacksaw,axe,ladders,rope and safety measures etc including disposal of trimmed branches 100 mtr away inside the cantonment area and cleaning the ares complete all as specified and directed by Engineer-in-charge.
M&L for disconnecting HT & LT side cables of follwing indoor/outdoor transformer of capacity 50 KVA to 500 KVA and earth strip from body and neutral of transformer mounted on two pole/four pole structure/staging/sub stn and taking down the transformer manually/using mechanical means and lifting loading and transportation to MES store yard/site to civil workshop for repair and opening of covers,draining out existing transformer oil,lifting of core,cleaning oil tank using chemicals,cleaning of core after removing HT/LT winding,re-assembling of new HT/LT windings with core varnishing heating and bringing back the same after repairs to the same point all as specified and directed by Engineer-in-charge. Note-(i) Rewinding of HT/LT coil any type/material,dihydretion of transformer oil reassembling after repair etc.will be measured and paid seperately under relevant item of the schedule. (ii) Spare part shall be measured and paid seperately as supply only and cost of fixing and connection of spare shall be deemed to included in the quoted rate of the above items complete all as specified and directed by Engineer-in-charge..
Dehydreation and filteration of exisitng transformer oil for transformer of any capacity using centrifugal plant to eliminate foreign particals and to improve die electric strength not less than 40 KV for one minute in 2.5 mm electrode gap as per relevant IS and to bring the acidity within the permissible limit complete all as specified and directed by Engineer-in-charge. Note- Transformer oil required for toping up shall be measured and paid for seperately under respective item of BOQ.
Supply and topping up to filling of fresh transformer oil conforming to IS-335 having die electric strength not less than 50 KV in existing transformer installed at different locations complete all as specified and directed by Engineer-n-charge.
M&L for re-winding of 11 KV HT coils with super enemelled best quality copper wire of existing guage with superior quality insulation material for transformer of capacity upto 500 KVA complete all as specified and directed by Engineer-in-charge.
M&L for re-winding of LT coils with super enemelled best quality copper wire of existing guage with superior quality insulation material for transformer of capacity upto 500 KVA complete all as specified and directed by Engineer-in-charge.
M&L for re-winding of 11 KV HT coils with super enemelled best quality Aluminium wire of existing guage with superior quality insulation material for transformer of capacity upto 500 KVA complete all as specified and directed by Engineer-in-charge.
M&L for re-winding of LT coils with super enemelled best quality Aluminium wire of existing guage with superior quality insulation material for transformer of capacity upto 500 KVA complete all as specified and directed by Engineer-in-charge.
M&L for assembling of HV and LV coils including necessary insulation with paper boards and varnishing,making internal connections,drying,removal of moisture from core and coils heating etc complete including testing of transformer on full load of capacity upto 500 KVA complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of ceramic LV bushing complete with bushing stud (brass metal) for transformer of capacity 50 KVA to 315 KVA complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of ceramic LV bushing complete with bushing stud (brass metal) for transformer of capacity 315 KVA to 500 KVA complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of ceramic HV bushing complete with bushing stud (brass metal) for transformer of capacity 100 KVA to 250 KVA complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of ceramic HV bushing complete with bushing stud (brass metal) for transformer of capacity 315 KVA to 500 KVA complete all as specified and directed by Engineer-in-charge.
M&L for supplying and refixing in replacement silica cork rubberised gasket, 5mm thick for transformer of capacity 100 KVA to 500 KVA complete all as specified and directed by Enginer-in-charge.
M&L for re-streaching of loose LT/HT over head line,aluminium conductor,GI guard wires and credals etc complete at various location and different span of 2 to 7 conductors with the help of rope and pullar etc complete all as specified and directed by Engineer-in-charge.
Disconnecting transformer of capacity 50 to 100 KVA , indoor/outdoor from HT/LT side carefully at site, dismantling carefully and removing primary and secondary terminals, top cover, conservator tank, neutral earth strips and draining out transformer oil to the required level and storing carefully in cleaned containers, cleaning of terminals, inspection of core, supply and replacing the 5 mm thick rubberised cork sheet gasket to leak proof seal under relevent item of this schedule for tank top cover and reassembling the complete dismantling items by replacing unserviceable minor spares such as nut, bolts, washers, expulsion vent diaphram, bush seals and filling drained out transformer oil after filtration to eliminate foreign particals and to improve die electric strength not less than 40 KV for one minute in 2.5 mm electrode gap as per relevant IS and to bring the acidity within the permissible limit complete and reconnecting the HT/LT supply cable ends at the site and testing complete all as specified and directed by Engr-In-Charge.
All as per item No 55 here in before but transformer of capacity above 160 KVA and up to 300 KVA complete all as specified and directed by Engineer-in-charge.
All as per item No 55 here in before but transformet of capacity 315 KVA to 500 KVA complete all as specified and directed by Engineer-in-charge.
Supply only Male and female contacts of HT 11 KV Airbreak switch GOD of 200 amps rating complete all as specified and directed. Note: fixing only measured under relevant item of this schedule complete all as specified and directed by Engineer-in-charge.
Taking out old unserviceable defective HT bushings from transformers by opening carefully primary and secondary terminals top cover conservator tank neutral earth strips and draining out transformer oil to the required level and storing carefully in cleaned containers for fixing porcelain bushing with brass studs under relevant items of the schedule and supply and fixng minor spares like nuts,rubber bush and washers connecting to winding and reassebling the complete dismantling items with same position, including reconnecting HT and LT sides by relacing suitable nut,bolts and lugs,testing and commissioning The transformer 50 KVA to 250 KVA capacity complete all as directed .
All as per item No 59 here in before but HT bush for transformer of capacity 300 KVA to 500 KVA complete all as specified and directed by Engineer-in-charge.
All as per item No 59 here in before but LT bush for transformer of capacity 300 KVA to 500 KVA complete all as specified and directed by Engineer-in-charge.
Taking out old unserviceable drain cocks from the transformers and Supply and fix new gun metal gate valve 25 mm bore along with brass/ gun metal dummy cap with rubbber washers as required at site complete all as specified and directed by Engineer-in-charge.
Supply and replace silica gel in to the serviceable breathers of transformers complete all as specified and directed by Engineer-in-charge.
Supply and replace silica gel breather by connecting required short length GI pipe of existing size with conservator oil tank for transformer of capacity 50 KVA to 160 KVA complete all as specified and directed by Engineer-in-charge.
All as per item No 64 above here in before but for transformer of capacity above 200 KVA and up to 315 KVA complete all as specified and directed by Engineer-in-charge.
All as per item No 64 above here in before but for transformer of capacity above 315 KVA and up to 500 KVA complete all as specified and directed by Engineer-in-charge.
Supply and fix self adhesive reflective radium stickers 75 mm wide around the street light poles 1.5 above ground level complete all as specified and directed by Engineer-in-charge.
M & L for preparation of old painted surfaces of HT/LT transformers of capacity 50 KVA to 160 KVA including removing oilly and greasy spots and applying one coat of synthetic enamel paint including white wash to transformer foundation plinth and lettering with white paint as MES NO/SM No, capacity, year of installation, serial No over a coat of black paint complete all as specified and directed by Engineer-in-charge.
All as per item No 68 here in before but transformer of capacity exceeding 160 KVA but not exceeding 300 KVA complete all as specified and directed by Engineer-in-charge.
All as per item No 68 here in before but transformer of capacity 315 KVA to 500 KVA complete all as specified and directed by Engineer-in-charge.
Shifting of transformers of capacity 50 KVA to 300 KVA from one location to another location under the area of GE Abohar as required and specified placing in position including making all connections and comissioning complete all as specified and directed by Engineer-in-charge.
All as per item No 71 here in before but transformer of capacity 315 KVA to 500 KVA complete all as specified and directed by Engineer-in-charge.
S&F PVC line separator suitable for 3 phase 4 wire on LT line all as directed complete all as specified and directed by Engineer-in-charge.
Taking down the HT Vacuum circuit breaker/RMU One incoming and two out going of capacity 1250/800/630/400 Amps , 11 KV 250 MVA for servicing, repairs replacement of difective/wornout components and reassembling complete comprisng of the following including testing and commissioning of the following including testing and commissioning to the entire satisfaction of Eingineer-in-charge. Make: SCHNEIDER (i) Dismantling the VCB//RMU One incoming and two out going from the enclosure consisting of vacuum interrupter assembly, socket contacts, checking the serviceablility of the folowing parts carefully including cleaning, adjustments, replacements, of defective/won our parts and re-assembling the complete (a) Cleaning the external surface of bushing with CTC or liquid ammonia to remove the accumulation of dirt or any other deposits. Inspction of bushings and make sure that vibration due to breake operation have not caused the bushings to miove resulting mis alignment of contacts. (b) Checking the vacuum/RMU interputer assemnbly and contact Checking the alignment of contacts and setting the contact surfaces to bare firm and uniform pressure and adjust the gap as per manufacture tolerance. Badly potted contact needs to be replaced Note Contacts shall be ordered saperately (c) Checking the breaker bushing of bus bar and circuit side inspecting the interval surface carefully for any charging/tracking, replacement of bushings. (ii) Dismantling the spring Charging mechanism of VCB/RMU, checking the operations of closing/tripping through closing/tripping coils electrically as well as manual charging including cleaing adjustements and replacement of defective/worn out parts re-assembnly complete for the following. (iii) Review the adjustement of all pressure switched land lockout devices. (a) Checking the ratchet wheel assembly, driving and charging parts including replacement of defective ratchet wheel and like parts (b) Checking the ratchet wheel assembly, driving and charging parts including replacement of defective ratchet wheel and like parts (c) Checking the operation mechanism of breaker and ensure its operation freely through lentyire stroke. Parts which shows excessive wear nd tear to be replaced or adjusted as per manufactures tolerance. (d) Checking of operating voltage watt mechanism termanials tripping arrangement for positive tripping. Contacts to be examined for their condition and operation. Dress the pitted contacts and replace if necessary. (iii) Review the adjustement of all pressure switched land lockout devices. (iv) Inspecting all bolts, nuts pins and collar pins and inplace and they are tight and opened properly Note : cost of additional hardware like bolts, nuts, washers and springs, washers, petroleum jelly etc, to put the breaker in serviceable condition is deemed to be included in the rated quoted. Inspection cleaning and re-lubrication of circuit breaker
Taking down old unserviceable Tripping coil for 1250/800/630 /400 A and supply and fix new Tripping Coil for630 /400 A Capacity replaced by unseriveable one all as complete all as specified and directed by Engineer-in-charge.
Taking down old unserviceable Closing coil for1250/800/630 /400 A and supply and fix new Closing Coil for 630 /400 A Capacity replaced by unseriveable one complete all as specified and directed by Engineer-in-charge.
Taking down old unserviceable TNC Switch and supply and fix new TNC (Trip, Neatural. Close) Switch for HT Panel replaced by unseriveable one complete all as specified and directed by Engineer-in-charge.
S&F copper strip 20X3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground or fixed on structure fixed with screws and bend to any shape as required for site complete all as specified and directed by Engineer-in-charge.
M&L for Earthing complete with copper earth plate electrode of size 600 x 600 x 3.15mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to copper strip of size 20 x 3mm earth lead by means brazing after fixing of nuts, bolts, check nuts, washers of galvanised iron steel, protected by galvanized iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x 10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, earth testing point, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion after taking down old earthing complete all complete all as specified and directed by Engineer-in-charge.
M & L for removing old unserviceable HT OH line jumpers/connectoers/taps/sleeves of any type and size rejumpering the same by supply and fixing suitable size of ACSR conductor as jumpers and testing the OH lines after reapir/replacement and maint of jumpers complete all as specified and directed by Engineer-in-charge. Note: (i) Connectors/Taps/Sleeves to be paid and measured separately under relevent items of this schedule. (ii) Jumpers set of three to be replaced in one job at one pole including in this item.
M&L for repair and maint of HT Air break GOD switch to removing carbon/burnt accessories and replacement of unservceable male and female contacts assembly including treatment with conducting jelly of contact points and removing/replacement of unserviceable jumpering with new ACSR conductor jumpers duly load test the HT OH lines jumpering position/points and provision for requiered minor spares like screws,nuts,bolts,washers and links are inclusive complete all as specified and directed by Engineer-in-charge. Note: Male and female contacts of HT Airbreak GOD switch will be measured and paid separately under relevant item of this schedule.
Laying and commissioning only HT UG Cable of size 3 Core , 95 to 185 Sqmm, 11000 V grade PVC/XLPE insulated, PVC sheathed armoured conductor laid in trenches/Road/paths/ on poles through GI protection pipe complete including connection of cable at both ends with suitable size of glands, aluminium lugs complete joining, testing and commissioning including disconnecting and removing existing UG Cable Note:1. HT UG Cable shall be laid against retrived Serviceable cable under relavent items of the schedule. 2. Earth work for the cable removing, laying measured and paid separately under relevent items of the schedule.
M&L for removing connections of faulty cable from both ends HT terminaton after meggaring and confirm the faulty cable taking directions from Engr-in-charge as specified and finding the spot of the cable faulty position with any other mechanism like cable fault locator or manual with necessary earth work made and remove the cable from the trench and jointing the cable to serviceable condition after necessary meggaring values obtain and shifting or relaying the cable complete all as specified and directed by Engineer-in-charge. Note: 1. Earth work for the cable removing, laying and necessary joints involved measured and paid separately under relevent items of the schedule. 2. hiring or arrangment of cable locator/cable route tracker/other any mechanisim with skilled operator for positioning the cable fault location is deemed to be included in the rates quoted
M&L for cutting,trimming bushes,weed/tidy plants to bring in a cleaned position of substation/transformer yard installation without disturbing installed accessories/equipments by using cutting equipments hacksaw,axe,ladders,sword,trimmer for well groomed with safety measures etc including disposal of trimmed branches 100 mtr away inside the cantonment area and cleaning the areas complete all as specified and directed by Engineer-in-charge.
laying only old bricks full size or useful obtaind from excavation against cable shifting/rerouting complete all as specified and directed by Engineer-in-charge.
M&L for emergency maintenance work of HT/LT over head line during breakdown by deploying skilled labour and electricians at faulty site having gang of mimimum 04 persons including transportation and other tools and plant required at site for fault rectification complete all as specified and directed by Engineer-in-charge. Note: Contractor or his rep shall come to the site of breakdown within two hours of notification of breakdown. Incase the contractor or his rep shall not come to the site of breakdown and start attending breakdown with in two hours of notification a penalty of Rs 500/- per fault per hour shall be imposed over contractor and same deduct from his dues
Material & Labour for Battery STT series Low maintenance tubular flooded OpzS volt cells of capacity 2 Volt, 100 Ah applications for switchgear/substations, leak proof with brass insert fully insulated flexible copper cables, vent cap fli-top flame arrestor with dust cap flot voltage 2.23 V/Cell, equalize voltage 2.33-2.4Volt / Cell, short circuit current 1240 Amps having positive and negative terminals for connecting further complete with jumper cables,fliptop flame arrestor vent caps no-oxide grease, intercell connector cables brass wire brush utility funnel and Operation manual complete all as specified and directed by Engineer-in-charge.
M&L for fabricating Battery bank rack assembly fabrication, use angles size 50x50 mm of 4 mm thickness and for batteries stacking use MS sheet thickness not less than 3.15mm size for surface of batteries stacking and connecting (approx size 110 Nos of batteries x size 1.5 feet x 1.0 feet= 165 Sq feet rack assembly) complete for stacking 110 Nos batteries of capacity 2 Volt 100 AH batteries and made suitable trays for each battery stacking in the MS sheet rack for holding complete weight of batteries and copper connecting heavy duty wire with crimping brass/copper terminals for battery termination and links for connecting one to each other complete all as specified and directed. NOTE: Battery stacking rack assembly shall be made with two layers of racks and minor spares like battery connecting wire, terminals, connectors are deemed to include with quoted rates. ------------------------------------------------------------------------------------------------------------ Note : A sum of Rs. 95,150.00 will be deducted on account of credit for taken down material. Please refer details on Srl Page No.30 (Schedule of Credit) of Tender documents.
Aman Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .