Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.9 LAccepted-AOC | ₹31.9 L Quoted ₹32.0 L | L1 | Accepted-AOC ACCEPTANCE |
| 2 | L2₹35.9 L+₹3.9 L (12.3%)Rejected-Finance 340 11 M S NATIONAL ENGINEERING CORP 340 11 SATTI STREET ROORKEE ROORKEE HARIDWAR UTTARAKHAND 247667 | HARIDWAR | UTTARAKHAND | 247667 | ₹35.9 L+₹3.9 L (12.3%) | L2 | Rejected-Finance HIGHER BIDDER |
| 3 | L3₹37.0 L+₹5.0 L (15.7%)Rejected-Finance MATHOSHREE PLOT NO 55 SR NO 787 A BEHIND ASHWANI HOSPITAL GOVIND NAGAR NASIK 422 009 | NASIK | NASHIK | MAHARASHTRA | 422009 | ₹37.0 L+₹5.0 L (15.7%) | L3 | Rejected-Finance HIGHER BIDDER |
| 4 | L4₹37.9 L+₹5.9 L (18.5%)Rejected-Finance 11 82 GROUND FLOOR BLOCK 11 KALYANPURI EAST DELHI DELHI 110091 | EAST DELHI | DELHI | 110091 | ₹37.9 L+₹5.9 L (18.5%) | L4 | Rejected-Finance HIGHER BIDDER |
| 5 | L5₹39.0 L+₹7.0 L (21.9%)Rejected-Finance | ₹39.0 L+₹7.0 L (21.9%) | L5 | Rejected-Finance HIGHER BIDDER |
Tender Value
₹33.2 L
EMD Value
₹66,400
Closing Date
8 Dec 2023, 6:00 pmClosed
COL BHUPINDER SINGH CWE NAVY VASCO
CWE NAVY VASCO VASCO DA GAMA GOA 403802
SPECIAL REPAIRS TO HT 11 KV 4 POLES 6 POLES 8 POLE STRUCTURE OH HT LINE TO RMU AT HANSA LEHAR NEAR RUNWAY AT INS HANSA UNDER GE NW VASCO
2023_MES_627214_1
85709/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
CWE NAVY VASCO
as per tender documents
9 documents required · 9 mandatory
₹500
GE (NW) VASCO
₹66,400
Yes
15 Jan 2024
7 Nov 2023
11 Dec 2023
7 Nov 2023
8 Dec 2023
24 Nov 2023
Amount
Supply, install ,testing and commissioning SF6 insulated compact Outdoor type R.M.U. rated voltage 11 KV,rated current 630 A, short circuit breaking current 16 KA and making capacity 40 KA ,fully arc proof metal enclosed, free standing, floor mounting, flush fronted type consists of manually /motoroperated non draw out type SF6 module-2 Nos load break switches (Incomers) and 8 No. Vaccum circuit breaker (outgoing) with integrated relays and related CTs as specified below, cable switch module and an interlocking mechanism with the earthing switch all as specified and directed. Degree of protection shall be per manufacturer specifications.
(a) Fixed type voltage indicators and electronic short circuit indicators for simple fault indication (b) Resin cast CT with ratio 50-100/1A with 2.5VA burden class 0.5 for metering and class 5 P10 for protection-Set of three (c) Resin cast potential transformers with ratio 11KV/1.732/110V/1.732, 50VA class0.5 with HT fuses . MeatringPT shall be fixed type provided .
(d) Self powered microprocessor controlled numeric relay comprising of three over current , one earth fault protection relay with high set for both phase & earth and with fault memory, universal auxliary supply (e) Trip circuit supervision relay (f) Master trip relay (g) Power pack equipment , with back up for 15minutes including batteries complete suitable for operation of relays
(q) Push buttons for accepting faults and reset (r) Rear bottom entry of HT cables Note :- (i) The quoted rate is inclusive of all the civil work for necessary foundation all as directed by Engineer in Charge . (ii) The quoted rate is inclusive of neat and clean the substation during work execution. (iii)The quoted rate is inclusive of aluminum tin shed above the angle iron frame of required size of RMU . Size of shed as per direction of Engr-In- Charge.
Dismantling of RCC pole carefully after taking shutdown properly with neat and clean yard as directed by engr-in-charge.
Dismantling of old ACSR conductor from structures carefully complete as directed by engr-in charge.
Dismantling old cross-arms of M.S. channel or angle sections etc. complete and setting aside for re-use with in 50m
Dismantling any type of insulator of any size complete all as directed by engr-in-charge.
Dismantling stay assembly complete as directed by engr-in-charge.
Supply & Lay , testing and commissioning XLPE cable , PVC insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty with aluminium conductor 11000 Volts grade (earthed), 3 core 95 sqmm laid in trenches/floor/duct/fixed on poles/through GI tubing in different locations / areas complete
S & F cable jointing kit for 11KV grade cable for Outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 120 sqmm.
S & F cable jointing kit for 11KV grade cable for Outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 70-95 sqmm.
S & F in repairs cable jointing kit for 11KV grade cable for Straight through joint heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 50 to 95 sqmm.
Excavation in trenches 1.5 Mtr wide and not exc 1.5 Mtr deep in hard/dense soil getting out and levelling of bottom surface to required level for laying UG cable / errection of poles all as specified.
Excavation in trenches 1.5 Mtr wide and not exc 1.5 Mtr deep in soft/disintegrated rock getting out and levelling of bottom surface to required level all as specified.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick.
Removing excavated material of soils from site to a distance not exc 50mtr away and depositing where directed not exc 1.5mtr from the starting point.
Supply and lay Double walled corrugated pipe (DWC ), heavy duty 110/95 mm bore for cable protection as a guard pipe including required accessories etc. complete as specified and directed.
M & L Earthing complete with copper earth plate electrode of size 60cm x 60cm x 3.15 mm thick, buried directly in ground vertically earth pit not less than 2.25 mtr deep below the ground level with top to edge of the plate n. less than 1.5 mtr below ground level connected to copper strip 32 x 6 mm as earthing lead by means of blots, nuts, check nut and washer of galvanized steel, including necessary earth work and excavation in any strata and PCC 1:3:6 type C2 chamber and RCC cover and light grade GI pipe 40 mm dia pipe of required length for protection of GI wire and water funnel and wire mesh with GI pipe medium grade 32 mm dia etc complete all as per electrical plate No 3 of SSR part - I and all directed including connections and testing on completion.
NATIONAL ENGINEERING CORPORATION
DURGAI ELECTRICALS
Bharat Sales Corporation
ASHIRWAD ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .