Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.8 LAccepted-Finance 82 6 82 6 TRANSPORT NAGAR NARWAL NARWAL JAMMU JAMMU AND KASHMIR 180010 | JAMMU | JAMMU AND KASHMIR | 180010 | L1 | Accepted-Finance BEING L1 | |
| 2 | L2₹21.4 L+₹4.6 L (27.7%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹24.5 L+₹7.7 L (45.9%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
29 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NAGROTA
GE NAGROTA C/O 56 APO
REPAIR AND MAINTENANCE OF MOTORS, VOLTAGE STABILIZER AND CONNECTED ITEMS AT GE NAGROTA.
2021_MES_478149_2
GEN-48/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
NAGROTA
Class E and above and Category b(I)
8 documents required · 8 mandatory
₹500
GE NAGROTA
₹50,000
Yes
30 Dec 2021
29 Oct 2021
1 Dec 2021
29 Oct 2021
29 Nov 2021
13 Nov 2021
60 days
Amount
Disconnecting the electrical connection for taking out unserviceable centrifugel pump capacity of 30 HP to 125HP from foundation including other accessories carrying to workshop for repair, complete all as specified and directed. Note : Spare parts such as contactors of various capacities will be measured and paid separately. The cost of transportation to workshop is deemed to be included in the quoted rate.
S & F in Replacement of following defactive part of centrifugal pumps set :-
Implers of exisiting size as directed by Engr in Charge
Galnd bush including gland packing of existing size as directed by Engr in Charge
Center guide of exisiting size as directed by Engr in Charge
Pump shaft of existing size as directed by Engr in Charge
Neck ring any size as directed by Engr in Charge
Remetaling, grinding, polishing and balancing of shaft for induction motor of capacity 5 to 15 HP, complete all as specified and directed. Note: (i) The rate for replacement of bushes, shaft sleeves etc required for making the shaft functional shall be included in the quoted rate).
All as per item No 3.00 here-in-before but of capacity 20 to 30 HP
All as per item No 3.00 here-in-before but of capacity 40 to 60 HP
All as per item No 3.00 here-in-before but of capacity 75 to 125 HP
S & F in replacement of ball bearing of induction motor/pump of capacity 5 to 15 HP as per existing size, complete all as specified and directed
S & F in replacement of ball bearing of induction motor/pump of capacity 20 to 30 HP as per existing size complete, all as specified and directed
S & F in replacement of ball bearing of induction motor/pump of capacity 40 to 60 HP as per existing size, complete all as specified and directed
S & F in replacement of ball bearing of induction motor/pump of capacity 75 to 125 HP as per existing size, complete all as specified and directed
S & F in replacement of star coupling suitable for connecting centrifugal motor and pump of capacity 75 HP , complete all as specified and directed.
S & F in replacement of Tyre coupling suitable for connecting centrifugal motor and pump of capacity 75 HP, complete all as specified and directed.
S & F in replacement of Tyre coupling suitable for connecting centrifugal motor and pump of capacity 125 HP, complete all as specified and directed.
Material and labour for rewinding of centrifugal motor of any description, dismantling and strip opening of the motor, removing the old existing burnt windings, cleaning the slots and rewinding of the electric motor of 3 phase, 415 Volts, 50 Hz AC supply and rewinding with existing gauge copper wire including insulating material such as illumines paper, etherized paper, cotton waste, glass sleeves insulating varnish etc, refixing on existing platform and connected all the electric connections and mechanical connections and testing the complete pumping set up to the entire satisfaction of the Engr-in-Charge for upto 10 HP capacity complete all as specified and directed. (Note: - Foundation nut bolts, washers and mounting pads required for fixing the centrifugal pumping sets and Booster pumping sets shall be provided by the contractor and rate for the same shall be deemed included in the quoted rates)
All as per item No. 14.00 here-in-before but capacity 15 HP to 20 HP
All as per item No. 14.00 here-in-before but capacity 25 HP to 30 HP
All as per item No. 14.00 here-in-before but capacity 35 HP to 40 HP
All as per item No. 14.00 here-in-before but capacity 50 HP to 60 HP
All as per item No. 14.00 here-in-before but capacity 60 HP to 75 HP
All as per item No. 14.00 here-in-before but capacity 125 HP.
Disconnecting the electrical connection for taking out unserviceable submersible pump capacity 12.5 HP to 40 HP from the bore well including column pipe and other accessories carrying to workshop for repair, complete all as specified and directed. Note : Spare parts such as contactors of various capacities will be measured and paid separately. The cost of transportation to workshop is deemed to be included in the quoted rate.
M&L for lowering the servicable submersible pump set capacity 12.5 HP to 40 HP after repair shifted to in its original location joint with column pipe and other accessories connecting to all electricals connection testing and commissioning the same capacity 12.5 HP to 40 HP complete all as specified and directed. ote : Spare parts such as contactors of various capacities will be measured and paid separately. The cost of transportation to workshop is deemed to be included in the quoted rate.
M&L for replacement the defactive part of centrifugal pumps set :-
Thrust plate of submersible motor 5 HP to 20 HP
Thrust plate of submersible motor 25 HP to 40 HP
Thrust bearing of submersible motor 5 HP to 20 HP
Thrust bearing of submersible motor 25 HP to 40 HP
Gun metal bushes for submersible motor 5 HP to 20 HP
Gun metal bushes for submersible motor 25 HP to 40 HP
Remetaling , grinding , polishing and blancing of shaft for submersible motor 5 HP to 20 HP
Remetaling , grinding , polishing and blancing of shaft for submersible motor 25 HP to 40 HP
Coupling arrangement with key of submersible motor 5 HP to 20 HP
Coupling arrangement with key of submersible motor 25 HP to 40 HP
Stainless steel shaft of submersible pump 5 HP to 20 HP
Stainless steel shaft of submersible pump 25 HP to 40 HP
Impellers for submersible pump 5 HP to 20 HP
Impellers for submersible pump 25 HP to 40 HP
Bowl bush for submersible pump set 5 HP to 20 HP
Bowl bush for submersible pump set 25 HP to 40 HP
Neck ring for submersible pump set 5 HP to 20 HP
Neck ring for submersible pump set 25 HP to 40 HP
M&L for removing the burnt winding wire of the submersible motor cleaning the slots for rewinding, and rewinding the motor with supper enamelled copper winding wire superior quality as per existing gauge and size, vanishing , drying, repalcement of bearing and assembling the motor of capacity of 12.5 HP to 15 HP complete all as specified and directed.
M&L for removing the burnt winding wire of the submersible motor cleaning the slots for rewinding, and rewinding the motor with sup[er enamelled copper winding wire superior quality as per existing gauge and size, vanishing , drying, repalcement of bearing and assembling the motor of capacity 30 HP to 40 HP complete all as specified and directed.
Replacement of following body part of submersible pump set as directed by Engr in charge
M&L in replacement of sand guard assembly of 40 HP submersible motor as existing make and size as directed by Engr in charge
M&L in replacement of sand guard assembly of 12.5 HP submersible motor as existing make and size as directed by Engr in charge
M&L in replacement of water filling plug of 40 HP submersible motor as existing make and size as directed by Engr in charge
M&L in replacement of water filling plug of 12.5 HP submersible motor as existing make and size as directed by Engr in charge
M&L in replacement of bush housing set including bush of 40 HP submersible motor as existing make and size as directed by Engr in charge
M&L in replacement of bush housing set including bush of 12.5 HP submersible motor as existing make and size as directed by Engr in charge
M&L in replacement of upper housing set of 40 HP submersible motor as existing make and size as directed by Engr in charge
M&L in replacement of upper housing set of12.5 HP submersible motor as existing make and size as directed by Engr in charge
M&L in replacement of lower housing set 40 HP submersible motor as existing make and size as directed by Engr in charge
M&L in replacement of lower housing set 12.5 HP submersible motor as existing make and size as directed by Engr in charge
M&L in replacement of mechanical seal of 40 HP submersible motor as existing make and size as directed by Engr in charge
M&L in replacement of mechanical seal of 12.5 HP submersible motor as existing make and size as directed by Engr in charge
M&L in replacement of seal guide sleeve of 40 HP submersible motor as existing make and size as directed by Engr in charge
M&L in replacement of seal guide sleeve of 12.5 HP submersible motor as existing make and size as directed by Engr in charge
M&L in replacement of startor assembly alognwith winding wire of 40 HP submersible motor as existing make and size as directed by Engr in charge
M&L in replacement of startor assembly alognwith winding wire of 12.5 HP submersible motor as existing make and size as directed by Engr in charge
M&L in replacement of roter assembly of 40 HP submersible motor as existing make and size as directed by Engr in charge
M&L in replacement of roter assembly of 12.5 HP submersible motor as existing make and size as directed by Engr in charge
M&L in replacement of cable connector sleeve and spring guide plate of 40 HP submersible motor as existing make and size as directed by Engr in charge
M&L in replacement of cable connector sleeve and spring guide plate of 12.5 HP submersible motor as existing make and size as directed by Engr in charge
M&L in replacement of tie rod/tie bolt of 40 HP submersible motor as existing make and size as directed by Engr in charge
M&L in replacement of tie rod/tie bolt of 12.5 HP submersible motor as existing make and size as directed by Engr in charge
M&L in replacement of diaphragram alongwith diaphargm spring of 40 HP submersible motor as existing make and size as directed by Engr in charge
M&L in replacement of diaphragram alongwith diaphargm spring of 12.5 HP submersible motor as existing make and size as directed by Engr in charge
M&L in replacement of doom nut and "O" ring of 40 HP submersible motor as existing make and size as directed by Engr in charge
M&L in replacement of doom nut and "O" ring of 12.5 HP submersible motor as existing make and size as directed by Engr in charge
Disconnecting the electrical connection for taking out unserviceable VT motor of 40 HP from foundation of bore well including other accessories carrying to workshop for repair and shifted to the existing bore well and reinstallation in original posing including all electrical connection testing and commissioning, complete all as specified and directed. Note : Spare parts such as contactors of various capacities will be measured and paid separately.
M&L for removing the burnt winding wire of the VT motor cleaning the slots for rewinding, and rewinding the motor with sup[er enamelled copper winding wire superior quality as per existing gauge and size, vanishing , drying, repalcement of bearing and assembling the motor of capacity 30 to 40 HP complete all as specified and directed.
M&L for lowering the VT pump of 40 HP after repair shifted to in its original location joint with column pipe and other accessories connecting to all electricals connection testing and commissioning the same complete all as specified and directed. ote : Spare parts such as contactors of various capacities will be measured and paid separately. The cost of transportation to workshop is deemed to be included in the quoted rate.
M&L of following body part of VT pump set as directed by Engr in charge
Gun metal impeller
Neck ring
Gland plate
Studs
Stainless steel line shaft 3 mtr long
Top shaft 1.5 mtr long
Guide spider 6"
Guide spider bush
Stainless steel sleeve
Shaft coupler
Stuffing box
Thrusht bearing
B Kulf bush
Maintenance of fully automatic solid state (CB-4SA) fault analyzer cum control system with Low voltage cut off 350 Volt AC, High Voltage Cut off 450 Volt AC, Pick up volt 360 Volt AC, Cut off time- Fraction of time and Unbalanced volt cut off- a deference of 35 Volt to 45 Volt between any two phase with 3 phase over load protection once in a month to make it functional at all the times for smooth operation of pumping set installed at various location of water supply installations, complete all as specified and directed. Note : (i) Spare parts such as contactors of various capacities will be measured and paid separately. (ii) Minor parts of the system will be replaced during checking and the cost of the same is deemed to be included in the quoted rate.
Disconnecting and removing to workshop opening for repair automatic voltage stabilizer for automatic operation air natural/oil cooled servo controlled type input voltage 260-440V and output voltage 420 V capacity 25 KVA to 30 KVA, complete all as specified and as specified and as directed Note :- (i) Cost of transportation of voltage stabilizer to workshop and back after repair/rewinding complete is deemed to be included in the quoted rate. (ii) Replacement of the parts if any found worn out/defective shall be measured and paid for separately.
All as per srl item No 32.00 here-in-before but of Capacity 50 KVA to 75 KVA.
All as per srl item No 32.00 here-in-before but of Capacity 160 KVA to 200 KVA.
All as per srl item No 32.00 here-in-before but of Capacity 400 KVA.
Dismantling and rewinding of dimmer coil with super enameled copper winding wire of existing make and size complete in all respect including varnishing tapping and insulating material to get same capacity of 25 KVA to 30 KVA, complete all as specified and directed.
All as per srl item No 36.00 here-in-before but of Capacity 50 KVA to 75 KVA.
All as per srl item No 36.00 here-in-before but of Capacity 160 to 200 KVA.
All as per srl item No 36.00 here-in-before but of Capacity 400 KVA.
Dismantling of primary and secondary coils carefully taking out winding wire preparing for rewinding with super enameled copper winding wire of appropriate guage with allied insulating material varnish the winding with air drying insulating varnish heat treatment etc of 50 KVA to 75 KVA complete, complete all as specified and directed.
All as per srl item No 40.00 here-in-before but of Capacity 80 KVA to 150 KVA.
All as per srl item No 40.00 here-in-before but of Capacity 160 KVA to 200 KVA.
All as per srl item No 40.00 here-in-before but of Capacity 400 KVA.
S&F in replacement of electronic circuit plate complete with DC transformers complete capacity of 25 KVA (PCB cold), complete all as specified and directed.
Dismantling of old servo motor and supply and fix new servo motor of capacity of 50 KVA along with all connected accessories and capacity, complete all as specified and directed.
Dismantling of old carbon bush with carbon holder and S & F new carbon bush with carbon holder of capacity 25 KVA, complete all as specified and directed.
S&F in replacement of brass studs fixed for 150 KVA voltage stabilizer input and output of stabilizer with brass nuts along with all necessary connection, complete all as specified and directed.
Supply & filling insulating oil (Tranformer oil) having dielectric strength not less then 40 KV (Rms) 4 mm gap with high viscosity in transformer, complete all as specified and directed.
S&F in replacement of power contractors 3 phase , 3 pole, 415 volts, 50 Hz suitable foor operation of a load of capacity of 70 Amps complete all as specified and directed
S&F in replacement of power contractors 3 phase , 3 pole, 415 volts, 50 Hz suitable foor operation of a load of capacity of 110 Amps complete all as specified and directed
S&F in replacement of power contractors 3 phase , 3 pole, 415 volts, 50 Hz suitable foor operation of a load of capacity of 185 Amps complete all as specified and directed
Taking down of manually operated oil immersed star delta starter of capacity 50 HP to 75 HP from its existing position, removing the transformer oil in a suitable container for reuse, replace the old unserviceable fixed and moving contract, over load coils, no volt coil complete and refixing the starter assembly in its existing position connecting the complete system and making the starter functional, complete all as specified and directed.
Dismantling of reduction gear flocculators/pre sedimentation tank type V 400 ratio 1:60 Make Radicon with replacement of V belts, gear oil, repair to gears, gear shaft, repair to rail and wheel of the flocculator, alingnment, complete all as specified and directed
M&L for making good and smooth position of floculators tack and wheel, dismantling the wheel and repair and greasing complete, check the whole track and replace broken and unallined part of track complete for smooth functioning of floculators complete all as specified and directed
M&L for redevelopment of air compressor of adequate capacity (not less than 250 cfm)) till the availability of sand free clear water subject to minimum 24 hrs of operation of air comressor, (rate shall include lowering, unlowering of submersible pump, transportation of necessary T&P, filling, jointing ad drainage of adequate size of air compressor complete all as specified and directed
Supply and fixing in replacement of submersible cable un armored PVC insulated & sheathed copper conductor cable 1100 Volts grade of size 16 Sqmm 3 core complete all as specified and directed.
S&F in replacement of single core copper conductor cable 1100 volts grade of sie 16 sqmm complete all as specified and directed
S&F in replacement of single core copper conductor cable 1100 volts grade of sie 25 sqmm complete all as specified and directed
S&F in replacement of single core copper conductor cable 1100 volts grade of sie 35 sqmm complete all as specified and directed
S&F in replacement of single core copper conductor cable 1100 volts grade of sie 70 sqmm complete all as specified and directed
Supply and fixing in replacement of MCCB 400 Amps 4 pole 415 Volts 36 KA with adjustable thermal and adjustable magnatic setting fixed in repair as per existing at site and all as specified and directed by Enginer-in-Charge.
Supply and fixing in replacement of MCCB 250 Amps 3 pole 415 Volts 36 KA with adjustable thermal and adjustable magnatic setting fixed in repair as per existing at site and all as specified and directed by Enginer-in-Charge.
Supply and fixing in replacement of MCCB 200 Amps 3 pole 415 Volts 36 KA with adjustable thermal and adjustable magnatic setting fixed in repair as per existing at site and all as specified and directed by Enginer-in-Charge.
Supply and fixing in replacement of MCCB 100 Amps 3 pole 415 Volts 16 KA fixed type as per existing at site and all as specified and directed by Enginer-in-Charge.
Supply and fixing in replacement of volt meter with CT as per existing size complete all as specified and directed.
Supply and fixing in replacement of Amp meter with CT as per existing size complete all as specified and directed.
Supply and fixing in replacement of indicator lamp assembly complete LED type suitable for the existing system supply voltage 230V/440V AC including taking down old lamp assembly complete all as specified and directed.
Deduction to be made from BOQ for schedule of credit (Sch 'A' Part - II) Amount of Rs. 65,376.00 during AOC Note:- Tenderers shall not quote for this Schedule
ASHOKA ENGINEERS AND BUILDERS
Nitika electricals and engineers works
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .