Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.2 CrAccepted-AOC | ₹21.2 Cr | L1 | Accepted-AOC Being the Lowest and reasonable tender |
| 2 | L2₹23.8 CrRejected-Finance | ₹23.8 Cr | L2 | Rejected-Finance Not being the Lowest |
| 3 | L3₹24.6 CrRejected-Finance K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110019 | ₹24.6 Cr | L3 | Rejected-Finance Not being the Lowest |
Tender Value
₹21 Cr
EMD Value
₹13.8 L
Closing Date
3 Feb 2024, 6:00 pmClosed
Chief Engineer (Navy) Mumbai
HQ CE (Navy) Mumbai, Shahid Bhagat Singh Marg, Colaba, Mumbai - 400 005
PROVISION OF DEFICIENT MARRIED ACCOMMODATION FOR OFFICERS (4 DUs, G PLUS 1F) (LT CDR AND ABOVE) AND FOR SAILORS (44 DUs, G PLUS 8F) (LDG AND BELOW) AT INS MANDOVI, GOA
2023_MES_625458_2
87926/E8
Open Tender
Civil Works
665 days
Goa
As per tender Documents
8 documents required · 8 mandatory
₹3,000
Garrison Engineer (P) Mandovi
₹13.8 L
Yes
15 Feb 2024
15 Dec 2023
6 Feb 2024
15 Dec 2023
3 Feb 2024
19 Jan 2024
15 Dec 2023 - 20 Dec 2023
Amount
SCHEDULE "A" Part - I (BUILDINGS & STRUCTURES WORKS) Total of Sch-'A' Part-I B/F
SCHEDULE "A" PART-II (SITE CLEARANCE, EXCAVATION & EARTHWORK) Total of Sch-'A' Part-II B/F
Blank
SCHEDULE "A" PART-IV (INTERNAL & HOT WATER SUPPLY) Total of Sch-'A' Part-IV B/F
SCHEDULE "A" PART-V (INTERNAL ELECTRIFICATION) Total of Sch-'A' Part-V B/F
SCHEDULE "A" PART-VI (ROADS/ PATH/ CULVERT & HARDSTANDING) Total of Sch-'A' Part-VI B/F
SCHEDULE "A" PART-VII (SEWAGE DISPOSAL) Total of Sch-'A' Part-VII B/F
SCHEDULE "A" PART-VIII (AREA DRAINAGE) Total of Sch-'A' Part-VIII B/F
SCHEDULE "A" PART-IX (EXTERNAL ELECTRIFICATION) Total of Sch-'A' Part-IX B/F
SCHEDULE "A" PART-X (EXTERNAL WATER SUPPLY) Total of Sch-'A' Part-X B/F
SCHEDULE "A" PART-XI (FENCING & GATE) Total of Sch-'A' Part-XI B/F
SCHEDULE "A" PART-XII (FIREFIGHTING) Total of Sch-'A' Part-XII B/F
SCHEDULE "A" PART-XIII (LIGHTNING PROTECTION) Total of Sch-'A' Part-XIII B/F
SCHEDULE "A" PART-XIV (TV & INVERTER WIRING) Total of Sch-'A' Part-XV B/F
SCHEDULE "A" PART-XV (TERRACE ROOFING) Total of Sch-'A' Part-XV B/F
SCHEDULE "A" PART -XVI (MISCELLANEOUS ITEMS)
SITE CLEARANCE, EXCAVATION & EARTHWORK
Removing excavated material (any type) and depositing it outside Ministry of Defence Land. Note :- (i) Before quoting the tender, the bidders are advised to ascertain the distance outside MD and, at which the excavated material/ debris are to be disposed off. No extra claim what-so-ever shall be entertained on this account. (ii) This item shall be considered as per the requirement at site.
BLANK
INTERNAL & HOT WATER SUPPLY
S & F 15mm dia Angular Stop cocks, fancy type, chromium plated, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed with wall flange (Make : Jaquar Model No CON-CHR-059KN or techno-commercial equivalent make mentioned in particular specification )
S & F 2 in 1 Health faucet with hook (chromium plated) and 1 to 1.5m long flexible tube with N.R.V (Make : Jaquar Model No ALD-CHR- 587 or techno-commercial equivalent make mentioned in particular specification )
S&F 15mm dia Brass CP long body bibcock with flange (Make : Jaquar Model No CON-CHR-107KN or techno-commercial equivalent make mentioned in particular specification )
S & F Overhead shower rose 120mm dia single flow (ABS Body Chromium plated with grey face plate) with rubit cleaning system with showerarm 190mm long with flange Make : Jaquar Model No OHS-CHR-1661 or techno-commercial equivalent make mentioned in particular specification.
S & F Sink cock long body, 15mm dia chromium plated with swinging spout (Wall mounted Model) Make : Jaquar or techno-commercial equivalent make mentioned in particular specification.
S&F 15mm dia Fancy type Pillar taps, cast copper alloy, withcapstan heads, chromium plated, screwed down high pressure. with or without letered 'Hot' or Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed
S&F 15mm dia Brass CP 3 way wall mixer for mixing hot & cold water screwed down for iron pipe and fixed. Make : Jaquar or techno-commercial equivalent make mentioned in particular specification.
S&F Gun-Metal Non Return Valve suitable for 15 mm bore dia tubes all as directed. (Hot Water supply)
INTERNAL ELECTRIFICATION
S &F Supply and fixing LED lights fitting 1x 10W, 2 feet, 220V, AC decorative box type with driver, holder Including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
S & F LED Bulb 9W including lamp holder
M & L For Submain wiring with 3x 6 sq mm size along with earth wire of size 1x 6 sq mm of FRLSH PVC insulated copper conductor, single core cable multistrands in and including 20mm PVC conduit of suitable size in all as reqd at site/directed. (From main L T panel to TPN DB 8 way.)
S & F Electric chimney 900 mm wide made up of high quality heat resistant tempered glass with two LED lamps for illumination and turbo suction 1000 cum per hour baffle and easy push button all as directed. Make-Faber, Elica, Hindware as approved.
EXTERNAL WATER SUPPLY
Supply, install test and commissioning of centrifugal pump set, electric driven complete wilth all accessoried suitable for pumping water minimum 450LPI\/I discharge at 40 m head coupled with suitable size of electric motor AC 3 phase ,50Hz including supply and fixing the items, such as necessary connection from starter to motor terminal using proper size of copper cable including .connection of suction pipe from pump to foot valve, delivery pipe connected to the raising mains of the over head rservoir by means of suitable joints, painting the suction and delivery pipe with super enamel paint over a coat of primer as per standared code of colour including IVIS base plate, excavation and PCC foundation as per site requirement etc complete all as specified and directed. Note : Suction and delivery pipes shall be measured and paid under appropriate items ( main water supply pump for UG sump).
Supply and fix C.I Foot Valve conforming to IS 4038, 80 mm dia all as specified and directed.
Construction of PCC block masonry valve chamber of size 600x600x600 mm (internal dia) suitable for 80 mm dia valve with necessary earth work excavation, plain cement concrete (1:4:8) using 40 mm graded stone aggregate, 75 mm thick in cement mortar (1:6), 15 mm thick plastering in CM ( 1:6) internally including flooring and externally rendering up to 15 mm below ground level, plain cement concrete (1:4:8 ) type B1 using 20 mm graded stone aggregate in coping, MS sheet cover made out of 3 mm thick MS sheet flat iron frame and bracing with locking arrangement ,applying two coats of synthetic enamel paint ,removal of debris to a distance not exceeding 50 mtr & depositing where as directed by Engr - in- charge
Construction of PCC block masonry valve chamber of size 450x450x450 mm (internal dia) with necessary earth work excavation, plain cement concrete (1:4:8) using 40 mm graded stone aggregate, 75 mm thick in cement mortar (1:6), 15 mm thick plastering in CM ( 1:6) internally including flooring and externally rendering up to 15 mm below ground level, plain cement concrete (1:4:8 ) type B1 using 20 mm graded stone aggregate in coping, MS sheet cover made out of 2 mm thick MS sheet flat iron frame and bracing with locking arrangement ,applying two coats of synthetic enamel paint ,removal of debris to a distance not exceeding 50 mtr & depositing where as directed by Engr - in- charge
Supply & fixing globe valve, 80mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete conforming to IS-778 with ISI mark grade-1alongwith one no of union complete all as specified and directed.
M&L for cutting in position existing DI/CI pipe line 100 mm bore for taping out branch connection including insertion of CI tee of requisite size & lead joints all necessary fittings as per site requirement including necessary excavation and earth work in any type of strata and disposal of surplus spoil outside Ministry of Defence Land complete all as specified
EXTERNAL ELECTRIC SUPPLY
Supply, install, testing and commissioning of Distribution transformer mounted on masonry platform stepdown, 11KV/.0.433KV, Three Phase complying with IS: 1180 (Part-I) 2014 with latest amendments, Outdoor type double copper wound suitable for 50 Hz system of capacity not less than 200 KVA, oil immersed naturally cooled delta connected on HT side and Star connected on LT side, Vector Group Dyn11, provided with OFF load tap changer to vary secondary voltage from -7.5% to + 7.5 % in step of 2.5%. Losses should be confined to the limits specified as follows: maximum allowable losses at full load (100% ) & Half Load (50%) shall not be exceeded 1.80% & 1.04% respectivly as per GRIHA RATING, Percentage Impedance: 5%. Losses and Impedance are subjected to tolerance as specified in IS 1180. The transformers should be supplied with first filling of oil confirming to IS 335 .The transformer should have both side cable end box with neutral brought out complete all as directed by Engineer - in -Charge and installation of transformer shall be carried out as per IS-10028 and comprising with the following standard fittings/ Technical specifications.
Supply Installation, commissioning and testing the following outdoor type 11 KV, 3 phase 50 cycle (50Hz) totally enclosed metal clad switch gear panel factory made, powder coated board with indoor vacuum circuit breaker floor mounted with common copper tinned bus bar complete all as specified (a) One No 400 Amps capacity triple pole metal clad HT control panel totally enclosed extendable pattern air insulated metal clad housing, floor mounting vertically isolated, vermin proof, fully interlocked horizontal draw out type having double isolation features & control device with grounded neutral system and equipped with the following equipment.
Supply of Electric rubber HT hand gloves 11 KV
Supply and fix M & L Hot dip galvanised iron octogonal pole of height 7 mtrs Each minimum galvanising of 70 microns, top 70 mm, bottom 130 mm and 3 mm sheet thickness in single section without any weld joints with square plate of minimum dimensions 225x225x12 mm foundation bolts, single arm G1 bracket of 900x1000 mm for mounting the light fitting, backelite sheet with one 6 A SP MOB and 16 mm stud type connectors - 04 nos inside the pole at the door opening for cable connections, common templates minimum Olfor each 15 poles all fixed and bolted on and including suitable POO pedestal as per manufacturers recommendations and specifications all as directed (for street/security lights) . Mast and pole shaft shall be as per BSEN 10025,13 5986, ASTM A572 Make of pole: Bajaj/Jindal/Crompton/Shubham Note: Rate quoted shall be deemed to be include necessary excavation and earthwork, PCC foundation etc all as per manufacturer recommendation
Earthing complete with galvanized steel earth plate electrode 600mm x600 mm x 6mm buried directly in ground vertically to a depth not less then 2.25 meter below normal ground level with top edge of the plate not less then 1.50 meter below normal ground level connected using galvanised iron strip 32x6mm as earthing lead by means of bolts ,nuts .check nuts and washers complete up to and including test point made out of 40 x 6mm alum flat including earthing pit , charcoal common salt .strip up to 7.5m, medium grade Gl watering pipe ,G.I. protection pipe 15 mm dia up to 7.5m long„PPC pit in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate ,PCC pit cover including earth work complete all as shown all as specified and as directed. NOTE-: G.I. protection pipe & GI earth strip beyond 7.5 meter shall be measured and paid for separately under relevant item of schedule . (i) Sailors Accn [ Int Elec. - 08 Nos, EWS - 02 Nos, EES - 12 Nos, DG Set - 04, FF - 04 Nos] (ii) LT CDR ABOVE - [ Int Elec : 4 Nos, Ext Elec 02]
M/L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6 mm thick hurried directly on ground earth pit not less than 2.25 m deep below the ground bend with top edge of the plate n. less than 1.5m below ground level connected to Gl earth wire 4 mm dia by means of bolts,nuts,checks nuts and washers of galvanised steel including necessary earth work and excavation in any type of strata , PCC 1:3:6 type C2 chamber and chamber cover , light grade Gl pipe 20 mm dia for protection of earth strip and Gl wire etc complete all as per electrical plate No.3 of SSR Part-I including connections with Earth testing point all as specified or indicated including testing on completion. NOTE: On testing after completion if the desired earth resistance is not obtained the earthing shall be redone by contractor at his own cost. EWS - 02 Nos, Lighting Protection - 06 Nos
Supply & Fix MCCB (D.B) vertical TPN 6 way double door with suitable rated bus bar including provision of 100 Amps 4 pole 16 KA MCCB along with connections and complete all as specified and directed by Engr in charge. Note: MCCB will be measured and paid separately under relevant schedule item.
S & F MCCB 100 amps 4 Pole, 36 KA,
Supply, Installation, Testing and Commissioning of 3-Phase, 4-Wir, 3X240V, Class 1.0 Smart Energy Meter, BIS marked IS- 16444, at the rating of 10-60A suitable for prepaid/ Postpaid mode. 1. The Smart Meter shall support the following minimum basic features: Measurment of electrical energy parameters; Bidirectional Communication; Intergrated Load limiting/connect/disconnect switch; Tamper event detection; recording and reporting; Power event alarms; Remote firmware upgrade; TOD features; On demand reading. 2. Meter shall have the ability to communicate with Head End System (HES) on RF Mesh Communication technology as mentioned in IS-16444 Part-1 in a secure manner. Data exchange protocol from smart meter to HES shall be based on open protocol like TCP/P or DLMS/COSEM. RF Mesh network should use 865-867 MHz Frequency band as permitted by WPC. Other RF Technologies like LoRAWAN, Zigbee, Bluetooth not desired. 3. Replacrment warranty period of Energy meter 5 Years. Make - HPL/ L & T/ Secure
BLANK
FIRE FIGHTING SYSTEM
Supply and fix Automatic air releae valve 50 mm dia suitable for domestic water with 50 mm Gun metal stop valve complete.
Supply and fix standard fireman's axe with heavy insulation rubber handle. '
Supply and lay control cable PVC insulated PVC sheathed galvanised steel strip or wire unarmoured with stranded copper conductor of size 1.5 sqmm 2 core 1100 Volts grade.
S &F 24 V DC Power supply
S &F Fire fighters Telephone jack
S &F Fire fighters Telephone handset
Supply & Fix 2 Core 1.5 sqmm twisted armoured FRLS Copper cable with necessary mounting accessories all as specified & directed. Make; Finolexr/Polycab/RR-Kabel
S&F 400 W Power Amplifier for high power speaker all as specified & directed.
S&F 2 W Multi Tap (0.25W, 0.5W, 1W &2 W) ceiling mounted speakers all as specified & directed.
S&F Fire Extinguisher, Dry Chemical Powder (ABC) Type, 6 Kg capacity, as per IS:15683 all as specified & directed.
S&F Fire Extinguisher, CO2 Type, 4.5 Kg Capacity, Light weight, Squeeze Grip Type, as per IS:15683 all as specified & directed.
S&F Fire Extinguisher, Mechanical Foam (AFFF) Type, 09 Ltrs Capacity, as per IS:15683 all as specified & directed.
M & L for Gl Slotted type cable trays of of size 100 x 50 mm x 2mm using MS angle, channels, flats etc.. All MS supports used shall be given one coat of red oxide primer & 2 coats of synthetic enamel paint of approved colour all as specified & directed.
Supply of fix yard hydrant post/ stand post including single headed hydrant valve 63 mm all as directed.
Supply and fixing fire alarm sounder/Sirens electronic type horizontal single stage continuous normal operation for atleast 50 Minutes with sound level 65 db to 120 db measured at 1.5 mtr with sound output varaition of +5 db 500 mtrs range.
S&F Digital Audio Amplifier 400W, at 70.7 VRMS output all as directed.
AVIATION OBSTRUCTION LIGHT
Supply and fix solar powered twin aviation obstruction light of 10W LED type with solar panel, battery ,complete circuit for auto On/Off and other fixing accessories complete all as specified & directed.
DG SET
(a) Supplying, installing, testing and commissioning, factory assembled silent Diesel Engine driven generator set, fully wired alternator AC to give an output of 50 KVA or nearest higher size continuously rating at a power factor 0.8 lagging, 3 phase 4 wire, 415 volts 50 Hz ± 1% supply, 1500 RPM, directly coupled with diesel engine liquid cooled mounted on common base frame complete with floor mounting fuel tank CO (service tank) of adequate capacity with fuel line & accessories, PCC foundation work as per manufacturer's instructions, vibration damper pads, control panel & other accessories etc and comprising of following. (b) Diesel Engine: Liquid cooled turbo charged with after cooler to deliver suitable BMP at 1500 RPM under NTP conditions of BS 5514 and conforming to IS 10002, DIN 6271 & ISO 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories:. Diesel engine of rated speed at full load electric start developing with system with radiator and including electronic governor control of class A1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries of adequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete. Make of engine: Kirloskar / Ashok leyland / Cummins / Greaves, Make of Alternator: Kirloskar /Stamford / Crompten / Jyoti
(a) Radiator with blower fan or heat exchanger with guard. (b) Pipe coupling for engine cooling system piping, (c ) Corrosion inhibitor coolant (d) Paper element filters (i) Fuel filter (ii) Lube oil filter (iii) By pass (e) Fly wheel housing and fly wheel to suit alternator. (f) Engine bearing mechanism in fly wheel housing. (g) Shut off coil with safeties for LLOP/HWT/over speed. (h) Dry type air cleaners and vacuum lndicators.(j) Residential silencers. (k) Stainless steel exhaust flexible bellows. (I) Motor driven priming pump.(m) Battery charging alternator.
(n) Exhaust piping made out of STIC C class, MS pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturer's recommendations to sustain back pressure with rain cap. (0) Mineral wool insulation 2 inch thick suitable for 400 degree Celsius termperature cladded with aluminium sheet o 30 gauge for the entire length of exhaust pipe. (p) First fill of oil, coolant and diesel during commissioning and 12 hours testing. (q) Interconnecting copper cabling of adequate capacity batteries control. (r) Fuel pipe class STIC 1"/1.5" /2" dia-01 lot (s) Self starter 12 volts DC. (1) Fuel injection pump. (u Electronic instrument panel, complete with all accessories as per manufacturer's specifications displaying the following:- (1) 24V Battery. () Water temperature. (i lubricating oil pressure (iv) Engine speed -1500Rpm (v) Engine hours (vi) Frequency. (vii) Voltage. (w) Safety control (Trip and indication).
(i) High water temperature (1) Low lube oil temperature (iii) Overspeed stop (v) Base frame: Sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturer's design alonwith AVM pads. (w) Fuel tank: 10 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick HR/MS sheet with level indicator fuel inlet, fuel outlet, air vent, drain plug, in let arrangement for diesel filling fro exterior canopy (without opening its panel) etc complete all as specified and directed. (c) Alternator: Suitable rated 50 KVA or higher, 0.8 pf, 415 volts, 3 phase, 4 wire, 50 Hz at 1500 RPM, self excited and self regulated with AVR brushles, screen protected, drip proof, insulation class-H, IP -23, voltage regulation grade - VG 3 self ventilated and conforming to BS: 5000/IS: 4722 suitable for engine as mentioned here-in before, conformig to IS: 13364(part-1) Make: stamford/crompton/kirloskar (d) Acoustic Enclosure:- M & L for acoustic enclosure for the above 50 KVA DG set to reduce noise level to 75 dB measured at 1.0 meter distance for audible frequencies as per guide of Central Pollution Control Board and size 3490 x 1340 x 1885mm and manufacturer's specification and comprising of following from authorised GOEMs of Gen Set manufacturer's specified :- (1) Sound Insulation: 100mm thick Rock wool (Density 64 Kg/Cum). (ii) Outer body: 1.6mm thick CRCA (i) Door: 1.6mm thick CRCA (iv) Base frame: ISMC 300 (v) Inside illumination 1 No.- 1 x 18 watt FTL fitting of make Phillips/ Bajaj Crompton.
TERRACE ROOFING
S & F 200 mm dia of half round / RECTANGULAR ready made PVC eaves gutter of pressure rating 6Kg/cm2 of approved make including necessasry fitting like bend WC/MS clips / end drops/ brackets / runner drop/ elbow drop etc. as applicable complete all as specified as and as directed
M & L for preparation of new surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of anti corrosive Epoxy paint over a coat of Epoxy primer , over a coat of red oxide on steel surfaces complete all as specified & directed. (Make- Asian Apcolite or techno-commercial equivalent in Berger , Nerolac )
ARBORICULTURE
LAWN Developing including necessary excavation & earth work to a depth of 30 cm in any type of soil , removing the roots and vegitations from the soil to a distance not exc 50 cm and levelling and applying of soil pesticides, dibbling of grass stellers of Bermuda grass, planting, rooting etc complete all as specified & directed.
ORNAMENTAL TREES : Developing trees by digging pits of size 0.60m x 0.60 m X 0.60 m and filling with red earth and manure in the proportion (3:1) and planting trees of different varieties 1.0 m to 1.5 m ht and 01 year old with proportionate girth in the filled up pits at a given distance etc; complete all as specified & directed.
Developing & Planting hedges by ht of 30 cm and above. 30 cm apart saplings Including excavation In trenches to a width of 45 cm and depth of 45 cm and filling the trenches with mixture of vermin compost / farm yard manure and red soil in proportion of 2:3 with necessary pesticides treatment all as specified and as directed including watering, manuring, necessary pesticides etc; complete all as specified & directed.
Providing and developing by digging pits 0.50 m x 0.50 m x 0.50 m and filling with sand , manure, and red earth in proportion of 1:2:5 planting with different variety shurbs (inclusive the cost of plants) all as specified & directed.
FURNITURE
Manufacture & Supply of Almirah Steel Medium, complete all as specified and shown on drawing No. FD-1032.
Manufacture & Supply of Chair dining, complete all as specified and shown on drawing No. FD/MAP-II/05.
Manufacture & Supply of Chair verandah, complete all as specified and shown on drawing No. FD/MAP-II/06.
Manufacture & Supply of Chair school with hand board, complete all as specified and shown on drawing No. FD/E6/MAP/05.
Manufacture & Supply of Charpoy IP Hard top, complete all as specified and shown on drawing No. FD/E6/MAP-II/01.
Manufacture & Supply of Peg Table, complete all as specified and shown on drawing No. FD-384.
Manufacture & Supply of Shoe Rack Steel, complete all as specified and shown on drawing No. FD/E6/MAP/02(R).
Manufacture & Supply of Table Dining 120x90cm, complete all as specified and shown on drawing No. FD/MAP-II/03.
Manufacture & Supply of Table dressing gents with mirror, complete all as specified and shown on drawing No. FD/E6/MAP/16.
Manufacture & Supply of Table Bed side, complete all as specified and shown on drawing No. FD/E6/MAP/15(R).
Manufacture & Supply of Almirah Steel Small, complete all as specified and shown on drawing No. FD-1032.
Manufacture & Supply of Almirah Steel Large 1/2H x 1/2S, complete all as specified and shown on drawing No. FD-E6/MAP/18.
Manufacture & Supply of Bath Stool PVC, complete all as specified and shown on drawing No. FD-E6/MAP/07.
Manufacture & Supply of Bed Hard, complete all as specified and shown on drawing No. FD/E6/MAP/08(R )
Manufacture & Supply of Bin linen Multi purpose with ironing board, complete all as specified and shown on drawing No. FD/E6/MAP/09.
Manufacture & Supply of Chair Dining Offrs, complete all as specified and shown on drawing No. FD/MAP-II/04.
Manufacture & Supply of Table dressing ladies with stool, complete all as specified and shown on drawing No. FD/MAP-II/07.
Manufacture & Supply of Chair writing, complete all as specified and shown on drawing No. FD/E6/MAP/12.
Manufacture & Supply of Chair computer, complete all as specified and shown on drawing No. FD/E6/MAP/01.
Manufacture & Supply of Charpoy folding IP with hardtop, complete all as specified and shown on drawing No. FD 388(R).
Manufacture & Supply of Table Dining 6 PERSONS , complete all as specified and shown on drawing No. FD/MAP-II/03.
Manufacture & Supply of Hat Stand with mirror , complete all as specified and shown on drawing No. FD 233.
Manufacture & Supply of Ladder aluminium, complete all as specified and shown on drawing No. FD-1025.
Manufacture & Supply of Table writing, complete all as specified and shown on drawing No. FD 275
Supply of Receptable PVC, complete all as specified and shown on drawing No. FD/E6/MAP/13.
Manufacture & Supply of Side board, complete all as specified and shown on drawing No. FD 1112.
Manufacture & Supply of Sofa Set 05 Seater - Cushioned, complete all as specified and shown on drawing No. FD/MAP-II/02.
Manufacture & Supply of Table Computer , complete all as specified and shown on drawing No. FD/E6/MAP/03
Manufacture & Supply of Teapoy , complete all as specified and shown on drawing No. FD -382
Manufacture & Supply of Teapoy verandah , complete all as specified and shown on drawing No. FD/E6/MAP/17
Manufacture & Supply of Trolly for TV, complete all as specified and shown on drawing No. FD/E6/MAP/04 ( R)
Manufacture & Supply of Table centre, complete all as specified and shown on drawing No. FD 274.
Manufacture & Supply of Chair verandah, complete all as specified and shown on drawing No. FD - 256
LIFTS
Supply, install testing & commissioning passengers lift, speed 1.5 metre/ sec, lift with single speed motor 41 Svolts, 3 phase, AC 50 Hz supply conforming to IS 14665, suitable to carry 8 passenger (544kg) serve G+ 8 upper floors with AC Variable Voltage &Variable Frequency drive(VVVF drive) Complete with all standard accessories, simplex automatic & manual dual controlled operation without attendant opening doors with door drive (electric moto:- driven mechanism), sliding stainless steel doors,Automatic rescue device (ARD) system, 3D infrared sensor in full height of door & built in announcing system without hand set (04 Nos,one each in car. Machine room & near Ground floor landing door) complete all specified. The lift shall conform to the following technical specifications. [i] Type of Lift: Passenger lift [ii] Load Capacity: 8 passenger (544kg) [iii] Speed: 1.5 m/s with single speed motor [iv] Power Supply: 3-Ph, 4 Wire, 415 V, 50 Hz AC [v] Type of Drive: AC Variable Voltage & Variable Frequency [vi] Type of Machine: Gearless [vii] Car Size: Not less than 1.43m² [viii] Car & Landing Door at all floors: COPD with VVVF door drive, opening size not less than 800 mm X 2000 mm, sliding type, fabricated by stainless steel not less than 16 gauge having hairline finish (N-304)
[ix] Car Enclosure: Manufactured with stainless steel frame not less than 16 gauge with hairline finish (N-304) having stainless steel false ceiling with hairline finish, internal lighting arrangement with LED light fittings operated on commericial supply and one LED light fitting operated on battery with invertor as emergency light, complete internal ventilation system provided with concealed axial / cross flow fan with auto cut-off system and stainless steel grill / wire-mesh for protection [x] Provision of standard thickness 40 mm diameter stainless steel hand-rail all around inside the car cabin incl standard size mirror [xi] Terminal Buffers: Metal special spring / PU / Oil buffers as per manufacturer's recommendation. The buffing stroke shall not be less than 200 mm. [xii] Door Opening (inside): Protected by COPD stainless steel door having hairline finish with opening not less than 800 mm X 2000 mm [xiii] Car & Counter Weight Guide: As per OEM recommendations [ixv] Flooring: 5 mm thick Alu. chequred plate / as per OEM design [xv] Signals: (a) Combined luminous hall buttons with LED / LCD / TFT hall position indicators at all floors (b) LED / LCD / TFT car position indicator panel of stainless steel (c) Car operating panel of stainless steel with luminous buttons in car (d) Car direction indicator in car & landing
(e) Battery operated alarm bell & emergency light (rechargable) along with suitable maintenance free battery. (The system shall be separate from ARD batteries.) (f) Overload warning feature in car cabin (display / announcing type both) (g) One fireman's switch to be installed at ground floor near landing door. (h) All signal fixtures & car operating panel on hairline stainless steel face plate with hairline finish (i) Infrared door sensor safety edge of door for entire height (j) Built in announcing system without handset 03 Nos., one for lift car & ground floor landing door and one announcing system with handset in machine room (k) The interior of the car shall be provided with a device that audibly announce the floor position of lift car has reached and announce that car entrance / exit door is open or closed [xvi] Stops & Opening: 09-09 with all openings being on the same side [xvii] Safety Device: (a) Automatic Rescue Device (ARD) / automatic landing device operating with maintenance-free batteries having suitable capacity. The batteries must have auto charging facilities. The charger input be connected with converter of regenerative drive. (b) The ARD actuation time shall be less than one second after failure of power supply and when ARD is operative the car shall stop at the nearest floor and then doors shall open.
[xviii] Operation: Simplex, full collective automatic operation with and without attendant. [xix] Machine Room: Located above the hoist way, details as per building drawings [xx] Hoist way: Construction details as per building drawings [xxi] Civil Work: Necessary civil work viz. making good disturbed surfaces, modification to landing space to suit car size, necessary foundation to machine(s), etc. [xxii] One number of wall mounted type telephone instrument installed inside of car cabin along with fixing arrangement and telephone cable of suitable size from car cabin to machine room run along with travelling cable. The telephone instrument shall be connected in the telephone DB installed in the machine room. [xxiii] Mirror of suitable size to be provided on complete wall opposite to main door above SS railing. [xxiv] Provision of suitable size of copper conductor XLPE insulated cable from Lift Panel installed at Ground floor to machine room will deemed to be included the rate quoted by the contractor
Supply, install testing & commissioning passengers lift, speed 1.5 metre/ sec, lift with single speed motor 415volts, 3 phase, AC 50 Hz supply conforming to IS 14665, suitable to carry 13 passenger (884kg) (used as service lift) serve G+ 8 upper floors with AC Variable Voltage &Variable Frequency drive(VVVF drive) Complete with all standard accessories, simplex automatic & manual dual controlled operation without attendant opening doors with door drive (electric moto:- driven mechanism), sliding stainless steel doors,Automatic rescue device (ARD) system, 3D infrared sensor in full height of door & built in announcing system without hand set (04 Nos,one each in car. Machine room & near Ground floor landing door) complete all specified. The lift shall conform to the following technical specifications. [i] Type of Lift: Passenger lift [ii] Load Capacity: 13 passenger (884kg) [iii] Speed: 1.5 m/s with single speed motor [iv] Power Supply: 3-Ph, 4 Wire, 415 V, 50 Hz AC [v] Type of Drive: AC Variable Voltage & Variable Frequency [vi] Type of Machine: Gearless [vii] Car Size: Not less than 2.20 m² [viii] Car & Landing Door at all floors: COPD with VVVF door drive, opening size not less than 800 mm X 2000 mm, sliding type, fabricated by stainless steel not less than 16 gauge having hairline finish (N-304)
[ix] Car Enclosure: Manufactured with stainless steel frame not less than 16 gauge with hairline finish (N-304) having stainless steel false ceiling with hairline finish, internal lighting arrangement with LED light fittings operated on commericial supply and one LED light fitting operated on battery with invertor as emergency light, complete internal ventilation system provided with concealed axial / cross flow fan with auto cut-off system and stainless steel grill / wire-mesh for protection [x] Provision of standard thickness 40 mm diameter stainless steel hand-rail all around inside the car cabin incl standard size mirror [xi] Terminal Buffers: Metal special spring / PU / Oil buffers as per manufacturer's recommendation. The buffing stroke shall not be less than 200 mm. [xii] Door Opening (inside): Protected by COPD stainless steel door having hairline finish with opening not less than 800 mm X 2000 mm [xiii] Car & Counter Weight Guide: As per OEM recommendations [ixv] Flooring: 5 mm thick Alu. chequred plate / as per OEM design [xv] Signals: (a) Combined luminous hall buttons with LED / LCD / TFT hall position indicators at all floors (b) LED / LCD / TFT car position indicator panel of stainless steel (c) Car operating panel of stainless steel with luminous buttons in car (d) Car direction indicator in car & landing
(e) Battery operated alarm bell & emergency light (rechargable) along with suitable maintenance free battery. (The system shall be separate from ARD batteries.) (f) Overload warning feature in car cabin (display / announcing type both) (g) One fireman's switch to be installed at ground floor near landing door. (h) All signal fixtures & car operating panel on hairline stainless steel face plate with hairline finish (i) Infrared door sensor safety edge of door for entire height (j) Built in announcing system without handset 03 Nos., one for lift car & ground floor landing door and one announcing system with handset in machine room (k) The interior of the car shall be provided with a device that audibly announce the floor position of lift car has reached and announce that car entrance / exit door is open or closed [xvi] Stops & Opening: 09-09 with all openings being on the same side [xvii] Safety Device: (a) Automatic Rescue Device (ARD) / automatic landing device operating with maintenance-free batteries having suitable capacity. The batteries must have auto charging facilities. The charger input be connected with converter of regenerative drive. (b) The ARD actuation time shall be less than one second after failure of power supply and when ARD is operative the car shall stop at the nearest floor and then doors shall open.
[xviii] Operation: Simplex, full collective automatic operation with and without attendant. [xix] Machine Room: Located above the hoist way, details as per building drawings [xx] Hoist way: Construction details as per building drawings [xxi] Civil Work: Necessary civil work viz. making good disturbed surfaces, modification to landing space to suit car size, necessary foundation to machine(s), etc. [xxii] One number of wall mounted type telephone instrument installed inside of car cabin along with fixing arrangement and telephone cable of suitable size from car cabin to machine room run along with travelling cable. The telephone instrument shall be connected in the telephone DB installed in the machine room. [xxiii] Mirror of suitable size to be provided on complete wall opposite to main door above SS railing. [xxiv] Provision of suitable size of copper conductor XLPE insulated cable from Lift Panel installed at Ground floor to machine room will deemed to be included the rate quoted by the contractor
M/L for earthing complete with copper earth plate electrode 60cm x 60cm x 3.15 mm thick hurried directly on ground earth pit n. less than 2.25 m deep below set the ground bend with top edge of the plate n. less than 1.5m below ground level connected to copper strip of size 20x3 mm as earth lead by means of , bolts,nuts,checks nuts and washers of galvanised steel including necessary earth work and excavation in any strata and PCC 1:3:6 type C2 chamber and chamber cover and light grade Gl pipe 40 mm dia for protection of earth strip and Gl wire etc complete all as per electrical plate No. 3 of SSR Part-I including connections with Earth testing point all as specified or indicated including testing on , completion. NOTE: (i) On testing after completion if the desired earth resistance is not obtained , the earthing will be redone at no extra cost. (ii) Copper earth strip beyond 7.5 meter length shall be measured and paid for separately .
COMPREHENSIVE MAINTENANCE OF LIFTS
Comprehensive maintenance and repairs of fully automatic electrically operated passenger lift (BOQ Item : 30.01) of any Make and installed capacity with a carrying capacity of 8 Passenger to serve (G+8 Floors) with AC variable voltage & variable frequency (VVVF drive) drive complete with all standard accessories, simplex collective automatic & manual dual controlled operation with/without attendant, automatic center opening doors with VVVF door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, Machine room & near Ground floor landing door) comprising of all devices and accessories through 36 months for all days including holidays etc after expiry of defects liability period as shown below and all as specified and directed to Engr-in-Charge for 01 no of lift Note : Contractor shall carryout comprehensive maintenance (routine, daily, weekly, monthly, quarterly, half yearly, yearly) through OEM as per MOU and maintain all the lifts in serviceable condition 24 hrs x 365 days with out any extra cost.
(a) 1st year after expiry of defects liability period
(b) 2nd year after expiry of defects liability period
(c) 3rd year after expiry of defects liability period
Comprehensive maintenance and repairs of fully automatic electrically operated passenger lift (BOQ Item : 30.05) of any Make and installed capacity with a carrying capacity of 13 Passenger to serve (G+8 Floors) with AC variable voltage & variable frequency (VVVF drive) drive complete with all standard accessories, simplex collective automatic & manual dual controlled operation with/without attendant, automatic center opening doors with VVVF door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, Machine room & near Ground floor landing door) comprising of all devices and accessories through 36 months for all days including holidays etc after expiry of defects liability period as shown below and all as specified and directed to Engr-in-Charge for 01 no of lift Note : Contractor shall carryout comprehensive maintenance (routine, daily, weekly, monthly, quarterly, half yearly, yearly) through OEM as per MOU and maintain all the lifts in serviceable condition 24 hrs x 365 days with out any extra cost.
(a) 1st year after expiry of defects liability period
(b) 2nd year after expiry of defects liability period
(c) 3rd year after expiry of defects liability period
S.N. Constructions
SOOD ASSOCIATES PVT LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid