Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance COMMISSIONER WALAJAPET MUNICIPALITY RANIPET DISTRICT | RANIPET | TAMIL NADU | 631001 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹7.5 L
EMD Value
₹7,500
Closing Date
30 Apr 2025, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
THE COMMISSIONER, JAYANKONDAM MUNICIPALITHY
MUNICIPAL OFFFICE, JAYANKONDAM
Providing UPVC Window, Door, Fixing Panel Board For Bus stand in Jayankondam Municipality
2025_MAWS_548245_1
0850/2025/E1
Open Tender
Civil Works
Works
60 days
MUNICIPAL OFFICE, JAYANKONDAM
Please refer Tender documents.
1 document required · 1 mandatory
₹0
₹7,500
30 Apr 2025
19 Apr 2025
30 Apr 2025
19 Apr 2025
30 Apr 2025
19 Apr 2025
Amount
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 25GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with spag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown olour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the executive Engineer before use on work
Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (uPVC) sections Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals.Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside.Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam. Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug
Supply fabrication erection and commissioining of 63A capacity dust and vermin proof floor mounting cubical type meter panel board made up of 16 SWG CRCA sheet steel for outer body on suitable AI frame work with 1 "x1/8" Cu. Bus for 3phases and 1"x1/8" bus for netural on synthetic moulded compound bus support with hylum sheet separation with providing necessary space for fixing of 7nos single phase energy meters on with double earth connection by 1"x1/8" cu. Flats with 2coats of high quality enamel paint over one coat of red oxide primer with following arrangements.6mm thick hylum sheet with separate door with visible glass for taking energy meter reading and supply and fixing of 7Nos 32A SP MCBs &32A fuse unit sets as per the the following details a) 3phase indicator lamp arrangment with fuse uints and control switches. b) Inter connection with busbars to all meters,MCBs and fuse units. c) Providing necessary arrangement for sealing 7nos energy meter by TNEB authorities. d) Floor mounting arrangement with 70mm x 40mm M.S. Channel frame work with necessary foundation bolt arrangment. e) Danger board as per IE rules & regulation
T KARUNAKARAN (BID ID -1325887)
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .