Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.8 LAccepted-AOC NEAR PAYAL CINEMA P O SEVOKE ROAD SILIGURI 734 001 | DARJEELING | WEST BENGAL | 734001 | ₹46.8 L Quoted ₹47.1 L | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹48.9 LRejected-Finance AMRITBASTI GARIGHURA PO SHIMULBARI PS KURSEONG DIST DARJEELING WB PIN CODE 734409 | 734409 | ₹48.9 L | L2 | Rejected-Finance Not Lowest Bidder |
| 3 | L3₹49.9 LRejected-Finance 30 HAREN MUKHERJEE ROAD HAKIMPARA SILIGURI 734 001 DARIEELING WB | DARJEELING | WEST BENGAL | 734001 | ₹49.9 L | L3 | Rejected-Finance Not Lowest Bidder |
| 4 | L4₹50.2 LRejected-Finance MILITARY ROAD OPP RHYTHM SHIVMANDIR PO KADAMTALA DARJEELING 734 011 | DARJEELING | WEST BENGAL | 734011 | ₹50.2 L | L4 | Rejected-Finance Not Lowest Bidder |
| 5 | L5₹50.4 LRejected-Finance VIVEKANANDAPALLY UPPER BAGDOGRA DIST DARJEELING WB PIN 734 014 | UPPER BAGDOGRA | DARJEELING | WB | 734014 | ₹50.4 L | L5 | Rejected-Finance Not Lowest Bidder |
| Sl No | Description | Qty | Unit | ELECTRO WIR WAY L6 | M/s TRIMURTI ASSOCIATE L2 | MS ORIENT ENGINEERING WORKS L3 | M/S A C PAUL L5 | Janata Enterprises L1 | M/s T K Das L7 | G C DUTTA N CO L4 | D K SARKAR L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in Soft/ Loose soil complete all as specified and directed. | 205 | Sqm | 20 ₹4,100 | 25 ₹5,125 | 20 ₹4,100 | 20 ₹4,100 | 15 ₹3,075 | 21 ₹4,305 | 19 ₹3,895 | 16 ₹3,280 |
| 2.00 | Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, laying of cable, erection of poles etc. not exc. 10 Sqm on plan and not exceeding 1.5 m in depth getting out in hard / dense soil complete all as specified and directed. | 3.5 | Cum | 200 ₹700 | 195 ₹682.50 | 190 ₹665 | 200 ₹700 | 192 ₹672 | 205 ₹717.50 | 195 ₹682.50 | 185 ₹647.50 |
| 3.00 | Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc. 10 Sqm on plan and not exceeding 1.5 m in depth getting out in soft / disintegrated soil complete all as specified and directed. | 54 | Cum | 250 ₹13,500 | 245 ₹13,230 | 240 ₹12,960 | 250 ₹13,500 | 220 ₹11,880 | 257 ₹13,878 | 244 ₹13,176 | 245 ₹13,230 |
| 4.00 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in each layer as in soil complete all as specified and directed. | 13.6 | Cum | 100 ₹1,360 | 100 ₹1,360 | 96 ₹1,305.60 | 100 ₹1,360 | 95 ₹1,292 | 103 ₹1,400.80 | 97 ₹1,319.20 | 92 ₹1,251.20 |
| 5.00 | Excavating post holes or similar holes, each not exceeding 0.5 Cum, getting out in Soft/ Loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and directed. | 14 | Each | 140 ₹1,960 | 135 ₹1,890 | 132 ₹1,848 | 135 ₹1,890 | 130 ₹1,820 | 139 ₹1,946 | 133 ₹1,862 | 135 ₹1,890 |
| 6.00 | Earth filling under floors incl spreading, leveling in layers n.exc 25cm thick including well ramming and watering as reqd. complete all as specified and directed. | 9 | Cum | 580 ₹5,220 | 540 ₹4,860 | 536 ₹4,824 | 550 ₹4,950 | 535 ₹4,815 | 564 ₹5,076 | 544 ₹4,896 | 520 ₹4,680 |
| 7.00 | M & L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. | 18.5 | Cum | 1,050 ₹19,425 | 955 ₹17,667.50 | 950 ₹17,575 | 980 ₹18,130 | 900 ₹16,650 | 1,000 ₹18,500 | 965 ₹17,852.50 | 900 ₹16,650 |
| 8.00 | Removing Excavated soils not exc 50 M and depositing where directed at a level not exc1.5 M above the starting point complete all as specified and directed. | 43 | Cum | 150 ₹6,450 | 130 ₹5,590 | 120 ₹5,160 | 125 ₹5,375 | 121 ₹5,203 | 128 ₹5,504 | 123 ₹5,289 | 115 ₹4,945 |
| 9.00 | M & L for Hardcore of gauge not exc. 63 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified and directed. | 24.7 | Cum | 1,600 ₹39,520 | 1,545 ₹38,161.50 | 1,542 ₹38,087.40 | 1,500 ₹37,050 | 1,650 ₹40,755 | 1,540 ₹38,038 | 1,564 ₹38,630.80 | 1,600 ₹39,520 |
| 10.00 | M&L for treating the bottom and sides of excavation at the rate of 5 ltr of anti termite chemical emulsion per Sqm of surface area complete all as specified and directed. | 42 | Sqm | 150 ₹6,300 | 150 ₹6,300 | 146 ₹6,132 | 140 ₹5,880 | 145 ₹6,090 | 3,180 ₹1.3 L | 148 ₹6,216 | 140 ₹5,880 |
Tender Value
₹43.5 L
EMD Value
₹87,000
Closing Date
29 Nov 2025, 6:00 pmClosed
Garrison Engineer Sukna
Garrison Engineer Sukna, Post-Simulbari, Dist-Darjeeling, WB-734009
SPL REPAIR TO APFC PANEL AND CONNECTED WORKS AT SUKNA AND CERTAIN OTHER SANCTIONED WORKS IN SUKNA MIL STN UNDER GE SUKNA
2025_MES_738729_1
GE Sukna/8897
Open Tender
Civil Works
270 days
SUKNA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE SUKNA
₹87,000
10 Jan 2026
7 Nov 2025
1 Dec 2025
8 Nov 2025
29 Nov 2025
22 Nov 2025
8 Nov 2025 - 29 Nov 2025
Amount
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in Soft/ Loose soil complete all as specified and directed.
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, laying of cable, erection of poles etc. not exc. 10 Sqm on plan and not exceeding 1.5 m in depth getting out in hard / dense soil complete all as specified and directed.
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc. 10 Sqm on plan and not exceeding 1.5 m in depth getting out in soft / disintegrated soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in each layer as in soil complete all as specified and directed.
Excavating post holes or similar holes, each not exceeding 0.5 Cum, getting out in Soft/ Loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and directed.
Earth filling under floors incl spreading, leveling in layers n.exc 25cm thick including well ramming and watering as reqd. complete all as specified and directed.
M & L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
Removing Excavated soils not exc 50 M and depositing where directed at a level not exc1.5 M above the starting point complete all as specified and directed.
M & L for Hardcore of gauge not exc. 63 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified and directed.
M&L for treating the bottom and sides of excavation at the rate of 5 ltr of anti termite chemical emulsion per Sqm of surface area complete all as specified and directed.
M&L for Plain Cement Concrete Type D2 1:4:8 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and directed.
M&L PCC 1:2:4 type B-1 (using 12.5 mm graded crushed stone aggregate) as in copings, bed plates, bed block for holdfasts, filling in pressed steel door frames, benching, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating and including necessary formwork complete all as specified and directed.
M&L cement concrete 1:2:4 type B1, (using 20 mm graded crushed stone aggregate) as in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, benching, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating and including necessary formwork complete all as specified and directed.
M&L PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in copings, bed plates, bed block for holdfasts, filling in pressed steel door frames, benching, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating and including necessary formwork complete all as specified and directed.
M & L for providing Reinforced cement concrete 1:2:4, Type B-1, Nominal Mix using 20 mm graded stone aggregate as in foundation including rafts, footing, foundation beams, plinth beams, bases for columns, basement slabs, under-reamed piles and mass concrete complete all as specified and directed. Note :- (Reinforcement shall be measured and paid seperately)
M & L for providing Reinforced cement concrete (1:2:4) type B-1 Nominal Mix using 20 mm graded stone aggregate as in slab supported on walls ,beams and coloumns in floors,roofs,landings, kitchen slabs etc complete all as specified and directed. (Note :- Reinforcement shall be measured and paid separately.)
M & L for providing Reinforced cement concrete (1:2:4) type B-1 Nominal Mix using 20 mm graded stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5 m span and like complete all as specified and directed. (Note :- Reinforcement shall be measured and paid separately.)
M & L for providing reinforced cement concrete 1:2:4, Type B-1, Nominal Mix using 20 mm graded stone aggregate as in columns, pillars, piers, posps and struts complete all as specified and directed. (Note :- Reinforcement shall be measured and paid separately.)
M&L for RCC M-25 (Design Mix) as in foundation including rafts, footings, foundation beams, plinth beams, bases of columns etc basement slabs reamed piles and mass concrete complete all as specified and directed. (Note :- Reinforcement shall be measured and paid separately.)
M&L for Reinforced Cement Concrete M-25 (Design Mix) as in Chajja complete all as specified and directed including necessary formwork rounded or chamfered on edges complete all as specified and directed. (Note :- Reinforcement shall be measured and paid separately.)
M&L for Reinforced Cement Concrete M-25 (Design Mix) using 20 mm graded stone as in beams, cantilevers, bressummers, lintels over 1.5m clear span complete all as specified and directed. (Note :- Reinforcement shall be measured and paid separately.)
M&L for Reinforced Cement Concrete M-25 (Design Mix) using 20 mm graded stone as in columns, pillars, piers, posts and struts complete all as specified and directed. (Note :- Reinforcement shall be measured and paid separately.)
Supply only integral water proofing compound complete all as specified.
M & L for brick work with sub class ‘B’ old size bricks straight or curved on plan n.exc. 6.00 m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for Brick work with sub-class `B' bricks, straight or curved on plan to any radius in half brick thick wall built in cement mortar 1:4 complete all as specified and directed.
M&L for 40 mm thick PCC 1:2:4 type B-0 (Using 12.5 mm graded stone aggregate) Damp proof course to horizontal or vertical surfaces including applying evenly a coat of blown type bitumen @ 1.50 Kg per Sqm including cleaning of surface and binding with clean dry sand @ 0.05 cum per Sqm including 200 micron Polythene film thick laid on a coat of bitumen primer, @0.30 to @ 0.50 kg per Sqm complete all as specified and directed.
M & L for use and waste of formwork to sides of concrete foundation, footing, bases of columns, raft & raft beams, sides and soffits (if any) of foundation and plinth beams; and similar works; in rough finished flat surface of concrete complete all as specified and directed.
M&L for rough finished flat formwork to soffits of suspended slabs such as roof slabs, floor slabs and similar work not exc. 200 mm thick (horizontal or sloping) work as rough finished surfaces of concrete complete all as specified and directed.
M&L for rough finished flat form work to chullah hoods, trough, chajjas, and similar work as rough finished surfaces of concrete complete all as specified and directed.
M & L for use & waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc. also splayes between floors and beams in rough finished flat surface of concrete complete all as specified and directed.
M & L for use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions in rough finished surface of concrete complete all as specified and directed.
S&F 30 mm thick flush door shutters solid core construction, with block board core and plywood face fanels, commercial type on both side and covered on both side with decorative face veneer with liping/frame to match complete all as specified and directed.
S&F 40 mm thick flush door shutters solid core construction, with block board core and plywood face fanels, commercial type on both side and covered on both side with decorative face veneer with liping/frame to match complete all as specified and directed.
S&F 150 mm long aluminium anodized barrel tower bolts of extruded section complete all as specified and directed.
Supply and fix 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy complete all as specified and directed.
S&F 250 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy complete all as specified and directed.
S & F 75 mm long medium weight, cold rolled mild steel Butt hinges with screws complete all as specified and directed.
S & F 100 mm long medium weight, cold rolled mild steel Butt hinges with screws complete all as specified and directed.
S&F 150 mm Aluminium handles cast type, anodised and fixed complete all as specified and directed.
S & F 150 mm long Extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S & F Floor door stopper of brass body and tongue, anodised, with hard drawn steel spring, fixed in floor, Overall length of cover plate 150 mm complete all as specified and directed.
S & F Galvanized mild steel wire cloth, 0.56 mm dia of wire and average width of aperture 1.18 mm and fixed with tinned stacks, or galvanized wire staples including wooden beads complete all as specified and directed.
S & F Mild steel work in framed work such as grills, gratings, framed guard bars, ladders etc., with ends of bars shouldered and/ or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tank and similar work confirming to Fe-290 Gde E-165 Complete all as specified and as directed by Engr-in-Charge.
M&L for mild steel work as in bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; handmade sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
M&L for Mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed.
M&L for Mild TMT bars 6 mm to 8 mm dia., cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed.
S & F Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) Structural steel work of angle, channel etc., confirming to Fe 410 -W (Gde- E- 250)complete all as specified and directed.
S & F Rolled Mild Steel Plates (plain or Chequered) channels, square cut or notched, (ordinary and counter sunk) forming holes, without any attachment quality A conforming to Fe-410W (Gde-E-250) quality-A complete all as specified and directed.
S&F rolled mild steel in plates, gusset plate (plain or chequered) channels square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment conforming to Fe-410W (Gde-E-250) quality-A complete all as specified and directed.
S & F of structural steel work as in tubular trusses including special shaped washers etc. complete using ERW or induction butt welded tubes conforming to IS – 1161 – 1979 grade St – 240 including fabrication complete all as specified and directed.
S&F steel ventilator with top hung shutter and including hinges steel peg stay complete all as specified and directed.
S & F of pressed steel frame of size 105 X 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plates etc complete all as specified and directed.
S & F of pressed steel frame of size 125 X 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plates etc complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm TCT (total coated thickness) of any colour having tensile strength of 550 Mpa as in roof covering cladding to wall etc, fixed with self tapping screws complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm TCT (total coated thickness) of any colour having tensile strength of 550 Mpa as in roof covering cladding to wall etc, fixed with self tapping screws complete all as specified and directed.
S&F in replacement 4 mm thick E-board (designer pattern) celing of size 60x60 cm, fixed or laid / inserted to with and including aluminium framework with screws in false ceiling (flat or sloping) of grid size 605 x 605 mm and with and including anodised aluminium snap grid with 25x25x1.5 mm thick Tee section and 38x25x2 mm thick angle for false ceiling Hangers with 6 mm dia. G.I. (length as required) adjusting level fixed to roof slabs/truss by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete all as specified and directed including necessary dismantling of existing unserviceable ceiling boards of any thickness incl cover fillets complete all as specified and directed.
M&L machine cut kota stone slab flooring treads etc 20-25 mm (minimum) thick as single piece in in treads, flooring etc laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab and including rubbing and polishing and laid over 20 mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L machine cut kota stone slab 20-25 mm thick as in skirting, dado, riser of steps, plinth, etc, laid over and including 15 mm thick backing in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the stone complete all as specified and directed.
M&L 75 mm thick, PCC 1:3:6, type C-2 (using 40 mm graded crushed stone aggregate) finished even and smooth without using extra cement as in plinth protection/path laid in alternate bays and construction joints to be given at every 3M interval and corners of buildings and filled with sealing compound Grade 'A' complete all as specified and directed.
M&L 75 mm thick, PCC 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate) as in sub floor, sub base of floor, paving, path etc complete all as specified and directed.
M&L 100 mm thick, PCC 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate) as in sub base finished even and rough complete all as specified and directed.
M&L for 40 mm thick PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) in floorings including finishing the surface even and smooth with using extra cement complete all as specified and directed.
M&L for PCC 1:2:4 type B-0, 25mm thick as in PCC underlayer finished even and rough to receive cement screed complete all as specified and directed.
M&L for Glass dividing strips, 38 x 3 mm thick and inserted in position to confirm to design complete all as specified and directed.
M&L for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed.
M&L Pre painted Powder coated anodised Aluminium door, window, Cup board and ventilator shutter and frame any type (Sliding or openable) with frame and other similar work, fabricated aluminium mesh etc. aluminium heavy section favricated incl all necessary roller wheels, cleats, handle, locking arrangement and arrangement to fix wire mesh with aluminium channel beading and stainless steel screw incl cost of rubber gasket ,beading roller wheel etc. complete Note-(a) the wt of rubber gasket beading, roller wheels, etc will not be measured with the wt of alumium shutters as only aluminium item shall be measured .(b)wire mesh shall be measured and paid saparately (c) Aluminium hinges shall be included in the unit rate
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished the surface even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished even and fair complete all as specified and directed.
M&L for rendering 15 mm thick on other than fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement using WPC compound complete all as specified and directed. Note:- WPC shall be measured and paid separatley.
M & L for painting the new Wall surface complete all as specified and directed as follows :- (a) Surface Preperation- Preperation of new wall surface. (b) Putty application- NIL. (c) Priming surface- NIL. (d) Painting- Applying three coats of white wash.
M & L for painting the new wall surface complete all as specified and directed as follows :- (a) Surface Preperation- Preparation of newly plastered or previously untreated surfaces of walls (b) Putty application- NIL (c) Priming surface- NIL (d) Painting- Applying two coats of cement base paint.
M & L for painting the new wall surface complete all as specified and directed as follows :- (a) Surface Preperation- Preparation of newly plastered or previously untreated surfaces of walls (b) Putty application- NIL (c) Priming surface- Applying one coat of cement base primer (d) Painting- Applying two coats of cement base paint.
S & F Sheet glass 3.0 mm thick, ordinary quality and glazing with oil putty or wooden beads not exceeding 0.5 Sqm in each pane glazed with putty or fixed with beads complete all as specified and directed.
S&F 4 mm thick obscured/ frosted / pin headed glass in ventilator shutters not exc 0.50 sqm in each pane complete all as specified and directed.
S&F 4 mm thick plain sheet glass ordinary quality fixed with aluminium frame work Not exc 0.50 sqm in each pane complete all as specified and directed.
M & L for painting the new wood surface complete all as specified and directed as follows :- (a) Surface preperation- Preperation of new wooden surfaces of any description, not otherwise described over 10 cm width or girth (b) Priming surface- Applying one coat of pink primer (c) Painting- Applying two coat of synthetic enamel paint.
M & L for painting the new wood surface complete all as specified and directed as follows :- (a) Surface preperation- Preperation of new wooden surfaces of any description, not otherwise described over 10 cm width or girth (b) Priming surface- NIL (c) Painting- Applying two coat of synthetic enamel paint.
M & L for painting the new steel surface complete all as specified and directed as follows :- (a) Surface preperation- Preperation of new steel surfaces of any description, not otherwise described over 10 cm width or girth (b) Priming surface- Applying one coat of red oxide primer (c) Painting- Applying two coats of synthetic enamel paint.
S & F of 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls complete all as specified and directed.
Supply in repair, installation, testing and commissioning of Automatic Power Factor Correction (APFC) panel outdoor type, factory made of 120 KVAR capacity ready to use design confirming to IS 5039 / IS 8623 & relevant IS/IEC codes rated for short circuit current rating of 50 KA, front openable & lockable by keys having louvers & air vent, gasket & totally vermin proof & suitable for 415/440 V, 3 Ph, 50 Hz, AC & housed in elegant enclosure fabricated from minimum 3.15 mm thick CRCA sheet & min 2.0 mm thick for partitions anti-corrosive coating to improve power factor to 0.99 & finally powder coated in texture siemens grey RAL 7032 incl suitable size & length of copper conductor cable PVC insulated for controls to each capacitor with & including the following accessories :- (a) 200 A capacity tinned copper bus-bar duly insulated with colour coated heat shrinkable sleeves & mounted on suitable sized DMC/epoxy insulators. (b) MCCB 4P, 200 Amps, 36 KA breaking capacity (Icu = 100 Ics) - 01 No as Incoming. (c) A set of heavy duty, capacitor heavy duty, type MDXL or any suitable type, 440 V with output capacity 120 KVAR, capacitor bank in suitable steps & configuration to accommodate all possible set for automatic operation to maintain 0.99 power factor. (d) MCBs TP, "C" series, 415 V of required sizes with required numbers & suitable ratings as per the capacity of the capacitors.
All as per item No. 77.00 above but for 60 KVAR.
All as per item No. 77.00 above but for 100 KVAR.
Supply and fixing in repair heavy duty copper wound quality factor >35 cylindrical capacitor of capacity 5 kVAr rated voltage 415 V , 50 Hz complete all as specified and directed.
All as per item No. 80.00 above but for capacity 10 kVAr.
All as per item No. 80.00 above but for capacity 15 kVAr.
All as per item No. 80.00 above but for capacity 20 kVAr.
All as per item No. 80.00 above but for capacity 25 kVAr.
Supply and fixing in repair APFC Controller of size 144x144 suitable for measuring 3 phase current and voltage , Power factor display upto 3 digit after decimal, dual Power facot setting for mains and DG operation, communication thriugh inbuilt MODBUS RS-485 Protocol complete all as specified and directed.
Supply and fixing in repair 3 Phase over current and earth fault relay having password ptotection facility, Last 30 trip data recording with date and time, IDMT & Definite time characteristics complete all as specified and directed.
M&L for ACB 4 pole,415 V, with thermal Magnetic Relese (Manual Fixed type) of capacity 630Amps complete all as specified and directed.
M&L for ACB 4 pole,415 V, with thermal Magnetic Relese (Manual Fixed type) of capacity 800Amps complete all as specified and directed.
Supply and installation testing and commissioning of MCCB 160 A with extended terminals both side 36KA 4 pole Ics=100%Icu with thermal maganetic protection unit of suitable size have to be fitted in existing LT Panel complete including old unsv one all as specified and as directed.
Supply and installation testing and commissioning of MCCB 250 A with extended terminals both side 36KA 4 pole Ics=100%Icu with thermal maganetic protection unit of suitable size have to be fitted in existing LT Panel complete including old unsv one all as specified and as directed.
Supply and installation testing and commissioning of MCCB 400 A with extended terminals both side 36KA 4 pole Ics=100%Icu with thermal maganetic protection unit of suitable size have to be fitted in existing LT Panel complete including old unsv one all as specified and as directed.
Supply,installing, testing and commissioning out door type LT feeder piller box of suitable size, padestal mounted, OEM own factory made, supplied by OEM, floor mounted, LT 415 V AC, 50 HZ, 3-phase 4 wire, AL Busbar chamber and PVC sheathed rating 400 Amps with color coding mounted on DMC insulator, confirming to protection class IP-54 weather and vermin proof. Panel will compliance IEC 61439, Mechanical Impact IK10. Double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet for outer portionand 2.0 mm CRCA sheet for inner portion, framing with 50 x 50 x 6 mm thick MS angle iron and legs of size 0.90m long, duly fabricated and having front hingled opening, rubber lining locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted internally and externally with powder coating (RAL -7032) suitable for 500 volts, 50 Hz, 3 phase 4 wire system, internal wiring with single copper conductor cable/PVC insulated tinned copper strip of suitable size for incoming to busbar and busbar to MCCBs/MCBs, fine wiring with single core copper conductor cable for instruments/indicating lamps and comprising with and including following accessories and mounted on PCC Plat form made out of PCC 1:3:6, 100 mm thick, 1 Mtr all round the panel board complete with the following items housed in including taking down old unsv one complete all as specified and directed by Engr-in-Charge.
Supply,installing, testing and commissioning out door type LT feeder piller box of suitable size, padestal mounted, OEM own factory made, supplied by OEM, floor mounted, LT 415 V AC, 50 HZ, 3-phase 4 wire, AL Busbar chamber and PVC sheathed rating 400 Amps with color coding mounted on DMC insulator, confirming to protection class IP-54 weather and vermin proof. Panel will compliance IEC 61439, Mechanical Impact IK10. Double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet for outer portionand 2.0 mm CRCA sheet for inner portion, framing with 50 x 50 x 6 mm thick MS angle iron and legs of size 0.90m long, duly fabricated and having front hingled opening, rubber lining locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted internally and externally with powder coating (RAL -7032) suitable for 500 volts, 50 Hz, 3 phase 4 wire system, internal wiring with single copper conductor cable/PVC insulated tinned copper strip of suitable size for incoming to busbar and busbar to MCCBs/MCBs, fine wiring with single core copper conductor cable for instruments/indicating lamps and comprising with and including following accessories and mounted on PCC Plat form made out of PCC 1:3:6, 100 mm thick, 1 Mtr all round the panel board complete with the following items housed in including taking down old unsv one complete all as specified and directed by Engr-in-Charge. Make of panel Accessories :- ABB/Havells/L&T
Supply,installing, testing and commissioning out door type LT feeder piller box of suitable size, padestal mounted, OEM own factory made, supplied by OEM, floor mounted, LT 415 V AC, 50 HZ, 3-phase 4 wire, AL Busbar chamber and PVC sheathed rating 400 Amps with color coding mounted on DMC insulator, confirming to protection class IP-54 weather and vermin proof. Panel will compliance IEC 61439, Mechanical Impact IK10. Double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet for outer portionand 2.0 mm CRCA sheet for inner portion, framing with 50 x 50 x 6 mm thick MS angle iron and legs of size 0.90m long, duly fabricated and having front hingled opening, rubber lining locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted internally and externally with powder coating (RAL -7032) suitable for 500 volts, 50 Hz, 3 phase 4 wire system, internal wiring with single copper conductor cable/PVC insulated tinned copper strip of suitable size for incoming to busbar and busbar to MCCBs/MCBs, fine wiring with single core copper conductor cable for instruments/indicating lamps and comprising with and including following accessories and mounted on PCC Plat form made out of PCC 1:3:6, 100 mm thick, 1 Mtr all round the panel board complete with the following items housed in including taking down old unsv one complete all as specified and directed by Engr-in-Charge. Make of panel Accessories: ABB/Havells/L&T
Supply,installing, testing and commissioning out door type LT feeder piller box of suitable size, padestal mounted, OEM own factory made, supplied by OEM, floor mounted, LT 415 V AC, 50 HZ, 3-phase 4 wire, AL Busbar chamber and PVC sheathed rating 400 Amps with color coding mounted on DMC insulator, confirming to protection class IP-54 weather and vermin proof. Panel will compliance IEC 61439, Mechanical Impact IK10. Double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet for outer portionand 2.0 mm CRCA sheet for inner portion, framing with 50 x 50 x 6 mm thick MS angle iron and legs of size 0.90m long, duly fabricated and having front hingled opening, rubber lining locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted internally and externally with powder coating (RAL -7032) suitable for 500 volts, 50 Hz, 3 phase 4 wire system, internal wiring with single copper conductor cable/PVC insulated tinned copper strip of suitable size for incoming to busbar and busbar to MCCBs/MCBs, fine wiring with single core copper conductor cable for instruments/indicating lamps and comprising with and including following accessories and mounted on PCC Plat form made out of PCC 1:3:6, 100 mm thick, 1 Mtr all round the panel board complete with the following items housed in including taking down old unsv one complete all as specified and directed by Engr-in-Charge. Make of panel Accessories: ABB/Havells/L&T
INCOMING :- (a) MCCB 4 pole 415 volts 35 KA breaking capacity rating 100 Amps, Ics=100% Icu, adjustable overload and adjustable short circuit setting, thermal magnetic type along with spreader terminals including fixing accessories :- 01 No BUSBAR:- (b) Aluminium busbar suitable for 250 Amp including insulator with nuts & bolts - 04 Nos OUTGOING:- (c) MCCB 4 pole 415 volts 25 KA breaking capacity rating 63 Amps Ics=100% Icu, adjustable overload and adjustable short circuit setting, thermal magnetic type along with spreader terminals including fixing accessories - 01 No (g) Lexic indicator lamp with holder = 03 nos
Supply, install, commissioning & testing of hi wall, split-type Air Conditioner Unit of capacity 1.5 TR or higher rating based on Non Inverter Technology comprising of copper compressor suitable for adjusting power depending on heat load incl indl indoor & outdoor units complete with cordless remote control unit & PM 2.5 Filter etc. for better indoor air quality with minimum 3 star rating incl electric connection complete all as specified and directed.
Supply, installation commissioning of glass top deep freezer, swing door, inbuilt lighting, single phase 240 volts, 50 Hz of capacity 320 Ltr complete all as specified and directed. Make :- Voltas, Bluestar, HITACHI, Godrej, or equivelent.
M&L for poing wiring with PVC Caping casing of 2.5 sqmm size single core multi stranded copper conductor unsheathed PVC insualted 1100V grade FRLSH cable drawn into and including PVC Caping casing adequate width and length with accessoris and fittings like bend, elebows, crosses wall crossing etc for one light/fan/bell point controlled by one switch including shunken type pressed steel box width 3 mm thick plastic laminated sheet top cover of approved make for housing switches, sockets outlet and regulators etc and with continous 1 No cable 2.5 sqmm copper conductor PVC insualted, unsheathed as earth wire connected to earth dolly and to be connected boxes of suitable sizes for mounting to fittings etc complete all as specified and as directed.
M & L for sub main wiring with 2 runs of 4.00 sqmm main wire alongwith 1 run of 4.00 sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade copper conductor cable, drawn through and including adequate size PVC casing caping (double lock pattern) with all fittings & accessories on walls / ceiling surfaces etc., complete all as specified and directed. NOTE :- Two runs of main copper conductor, one run of earth wire and one run of PVC casing caping shall be measured as one unit length.
S&F Double pole & neutral enclosure with a two pin & earth plug and socket complete with one single pole MCB "C" Curve of 20 Amp rating complete all as specified and directed.
S&F switch socket combination 3 pin 15 Amp, flush type universal complete all as specified and directed.
Supply, installation commissioning & testing of wall-mounted copper wound voltage stabilizer, ISI marked for automatic operation, single phase, naturally air cooled, indoor type & designed for I/P variation between 170V to 260 V with O/P voltage stabilization at 230 V with accuracy of +/-2.5%, with high & low voltage cut off & time delay & of capacity 4.0KVA suitable for deep freezer including electric connection complete all as specified and directed. Make :- V-Guard / Sen & Pandit / Volina or equivalent.
Supply, install, commissioning & testing of wall-mounted copper wound voltage stabilizer, ISI marked for automatic operation, single phase, naturally air cooled, indoor type & designed for I/P variation between 170 V to 260 V with O/P voltage stabilization at 230 V with accuracy of +/- 2.5%, with high & low voltage cut off & time delay & of capacity 4.0 KVA suitable for 1.5 TR AC incl electric connection complete all as specified and as directed. Make : V-Guard/Sen & Pandit/Volina or equivalent.
M/s TRIMURTI ASSOCIATE (BID ID -3485327)
MS ORIENT ENGINEERING WORKS (BID ID -3485474)
G C DUTTA N CO (BID ID -3485870)
M/S A C PAUL (BID ID -3485599)
ELECTRO WIR WAY (BID ID -3485056)
M/s T K Das (BID ID -3485708)
D K SARKAR (BID ID -3485405)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Document
0.17 MB
Tender Documents
Tender Documents • 1.65 MB
BOQ
BOQ • 0.43 MB
Download all tender documents and submit your bid