MAJ UDAY SHANKAR ROY
GE AF SURATGARH
REPAIR/MAINT OF OVERHEAD LINE, LT UG CABLE AND ALLIED E/M WKS AT AF STN SURATGARH
2024_MES_668674_1
8191/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) SURATGARH
As per tender Documents
10 documents required · 10 mandatory
₹500
GE (AF) SURATGARH
₹99,000
Yes
19 Oct 2024
31 Aug 2024
30 Sept 2024
31 Aug 2024
28 Sept 2024
14 Sept 2024
Amount
BOQ ( REPAIR/REPLACEMENT OF LT UG CABLE AND CONNECTED E/M WORKS AT KV No 1 AT AF STN SURATGARH)
Excavation in trenches not exc 1.5m wide and not exc 1.5m in depth for laying of cable/shifting of cable/pole/panel/pipe and getting out in soft loose soil, complete all as specified and directed by Engr-in-charge.
All as per item No. 1 above but depth exceeding 1.5m and not exceeding 3m complete all as specified and directed by Engr-in-charge.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25cm thick, complete all as specified and directed by Engr-in-charge.
Removing of excavated material not exc 50m and depositing where directed at a level not exc 1.5m above the starting point, complete all as specified and directed by Engr-in-charge.
M&L for PCC 1:3:6 type C-2 using 40mm graded aggregate as in foundation for filling in, mass concrete for foundation of pole, Transformer, panel board, stay, post top lantern, repairs to road cutting, drain, path etc complete all as specified and directed by Engr-in-charge.
M&L for PCC (1:2:4) type B-1 using 20mm graded aggregate as in coping of new pole/reconstruction old damaged copings etc, including necessary form work, complete all as specified and directed by Engr-in-charge.
M&L for sand cushioning to cables with a layer of sand 8cm deep before laying the cable and 15cm depth (punned down to 10cm depth after laying and stretching of cable), complete all as specified and directed by Engr-in-charge.
M&L for brick of common burnt clay, sub class 'B' old size laid flat and dry on cables an in cable protection in trenches over cables prependicular to direction of cables abutting each other, complete all as specified and directed by Engr-in-charge.
Dismantling taking out carefully old/unserviceable UG cable any type any size from trenches/poles/ducts/LT panels after dismentling ends from OH conductors/MCCBs/joint boxes for relaying/refixing or carrying to store for Sch of Credit, complete all as specified and directed by Engr-in-charge.
M&L for fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board, 1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed 6sqmm 2 core with required aluminium cable lugs, heat shrink joints, Colour code heat shrink sleeves at both cable ends all as specified and complete all as specified and directed by Engr-in-charge. Note:- Heat shrink straight through joint 2 core/4 core will be measured and paid separately in this schedule.
All as per item No. 10 here-in-before but 10sqmm 2 core, complete all as specified and directed by Engr-in-charge.
All as per item No. 10 here-in-before but 16sqmm 2 core, complete all as specified and directed by Engr-in-charge.
All as per item No. 10 here-in-before but 10sqmm 4 core, complete all as specified and directed by Engr-in-charge.
All as per item No. 10 here-in-before but 16sqmm 4 core, complete all as specified and directed by Engr-in-charge.
All as per item No. 10 here-in-before but 25sqmm 3,5 core, complete all as specified and directed by Engr-in-charge.
All as per item No. 10 here-in-before but 50sqmm 3.5 core, complete all as specified and directed by Engr-in-charge.
All as per item No. 10here-in-before but 70sqmm 3.5 core, complete all as specified and directed by Engr-in-charge.
All as per item No. 10 here-in-before but 95sqm 3.5 core, complete all as specified and directed by Engr-in-charge.
All as per item No. 10 here-in-before but 120sqmm 3.5 core, complete all as specified and directed by Engr-in-charge.
All as per item No. 10 here-in-before but 150 sqmm 3.5 core, complete all as specified and directed by Engr-in-charge.
All as per item No. 10 here-in-before but 185 sqmm 3.5 core, complete all as specified and directed by Engr-in-charge.
All as per item No. 10 here-in-before but 240 sqmm 3.5 core, complete all as specified and directed by Engr-in-charge.
Labour only for fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board at existing places or carrying to other location, upto 1100 volts grade heavy duty cable with XLPE/PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed of size upto 25sqmm 4 core obtained from item no-09 here-in-before with required aluminium cable lugs, heat shrink joints, complete all as specified and directed by Engr-in-charge.
All as per item No. 23 here-in-before but 35 sqmm 3.5 core to 120sqmm, 3.5 core, complete all as specified and directed by Engr-in-charge.
All as per item No. 23 here-in-before but 150sqmm 3.5 core to 400sqmm, 3.5 core, complete all as specified and directed by Engr-in-charge.
Excavation of road cuttiug by manually including making good to disturb surface with PCC 1:2:4 type B2 on top not less than 150mm thick including levelling and cambering according to existing road surface, refilling, watering, ramming etc complete all as specified and directed by Engr-in-charge.
Dismentling taking out broken/worn out steel pole/PCC Pole of 8.5 to 9.50 mtr long and keeping aside for refixing or carrying to store for credit, complete all as specified and directed by Engr-in-charge.
M&L for steel tubular swaged pole complete with cast iron base plate, finial taper plug bolts nuts and screws confirming to IS : 2713 and made out of structural steel tube confirming to IS: 1161 and painted internally with a coat of bituminous paint and externally one primer coat, one under coat and one finishing coat of aluminium paint as specified type 410 SP-31 (9 mtr long), complete all as specified and directed by Engr-in-charge.
Labour only for re-fixing of steel tubular swaged pole complete with cast iron base plate, painted internally with a coat of bituminous paint and externally one primer coat, one under coat and one finishing coat of aluminium paint as specified type (9 mtr long), complete all as specified and directed by Engr-in-charge.
Dismantling and taking down old/unsv cross arms, bracing, supports etc complete for reuse at site or carrying to store for sch of credit complete all as specified and directed by Engr-in-charge.
S&F for cross arms bracings supports clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paints, complete all as specified and directed by Engr-in-charge.
Dismantling and taking down old/unsv ACSR conductor any size complete for reuse at site or carrying to store for Sch of Credit all as specified and directed by Engr-in-charge.
S&F for ACSR conductor incl jointing with existing conductor and straining on LT pole and proper fastening to pin/shackle insulators with aluminium binding wires and required jumpering connection, complete all as specified and directed by Engr-in-charge.
Dismantling and taking down old/unsv insulator of any type any size from pole/stay for reuse at site or carrying to store for sch of credit, complete all as specified and directed by Engr-in-charge.
S&F pin type, porcelain, vitreous, brown, including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut, 100mm height and 65 mm dia for 1100 volts grade, complete all as specified and directed by Engr-in-charge.
S&F shackle type, porcelian vitreous white, brown or green insulator including galvanised mild steel straps , washers, insulators bolts ,washer and nuts of size 100mm height and 115mm dia for 1100 Volts grade complete all as specified and directed by Engr-in-charge.
S&F Loop type insulator, porcelian vitreous brown of size 65mmX90mm and clearence hole 16mm all as specified and directed by Engr-in-charge.
M/L for stay assy using 16mm dia galvanised rod complete all as shown in electrical plate No 1 of SSR Part I incl dismentling unsv one complete all as specified and directed by Engr-in-charge. Note:- Clamps, loop insulator, earth work, PCC measured separately.
S&F for stay wire using galvanised steel strand of 7/3.15mm complete with necessary binding incl dismentling taking down unserviceable one complete all as specified and directed by Engr-in-charge.
S&F cradle hexagonal /rectangular fabricated with galvanised steel wire not less than 4mm dia on pole incl dismentling taking out unsv cradle guard, complete all as specified and directed by Engr-in-charge.
S&F earth continuity wire using GI wire not less than 4mm dia on pole incl dismentling taking out unsv GI wire, complete all as specified and directed by Engr-in-charge.
M&L for restraining of overhead ACSR conductor of any size of 4 wire on pole after disconnecting all jumpering connection & binding of insulators and redoing all jumpering connection and insulator binding with aluminium conductor providing required T&P, complete all as specified and directed by Engr-in-charge.
M&L for restraining of ACSR conductor of any size of 2 wire on pole after disconnecting all jumpering connection & binding of insulators and redoing all jumpering connection and insulator binding with aluminium conductor providing required T&P, complete all as specified and directed by Engr-in-charge.
M&L for restraining of GI Cradle guard hexagonal/rectangular of any size on pole after disconnecting all binding on cross arms and redoing all bindings providing required T&P complete all as specified and directed by Engr-in-charge.
M&L for restraining of GI wire of any size on pole after disconnecting all binding on cross arms and redoing all bindings providing required T&P, complete all as specified and directed by Engr-in-charge.
Cutting/Trimming of tree branches arround 3.00 mtr distance from conductors of HT over head line of span up to 50 meters including removing of creepers etc frompoles, complete all as specified and directed by Engr-in-charge.
Cutting/Trimming of tree branches arround 3.00 mtr distance from conductors of LT over head line of span up to 40 meters including removing of creepers/vegitation etc from poles, complete all as specified and directed.
M&L for painting of steel pole any type up to 7.5 mtr height above ground level including cross arms,clamps,stay clamps etc with two coats of aluminium paint after surface preparation, complete all as specified and directed.
Numbering of steel poles serially with letter/number size width and height up to 40mm in situ with black paint on white back ground, complete all as specified and directed.
S&F Heat shrink joint indoor/outdoor LT 1100 volts grade 10-16sqmm, 4 core including exacavation work complete all as specified and directed by Engr-in-charge. Make-Raychem, Cat No-EPKT0003 or equivelent of M-Seal/MS Seal/3M
S&F Heat shrink joint indoor/outdoor LT 1100 volts grade 25-50sqmm, 4 core, complete all as specified and directed.. Make-Raychem, Cat No-EPKT0019 or equivelent of M-Seal/MS Seal/3Maychem/M-Seal/MS Seal/3M
S&F Heat shrink joint indoor/outdoor LT 1100 volts grade 70-150sqmm, 4 core, complete all as specified and directed. Make-Raychem, Cat No-EPKT0035 or equivelent of M-Seal/MS Seal/3M
S&F Heat shrink joint indoor/outdoor LT 1100 volts grade 185-300sqmm, 4 core, complete all as specified and directed. Make-Raychem, Cat No-EPKT0051 or equivelent of M-Seal/MS Seal/3M
S&F Heat shrink straight through joint LT 1100 volts grade 10-16sqmm, 4 core including exacavation work complete all as specified and directed by Engr-in-charge. Make-Raychem, Cat No-EPKJ0123 or equivelent of M-Seal/MS Seal/3M
S&F Heat shrink straight through joint LT 1100 volts grade 25-50sqmm, 4 core including exacavation work, complete all as specified and directed by Engr-in-charge. Make-Raychem, Cat No-EPKJ0130 or equivelent of M-Seal/MS Seal/3M.
S&F Heat shrink straight through joint LT 1100 volts grade 70-150sqmm, 4 core including exacavation work complete all as specified and directed by Engr-in-charge. Make-Raychem, Cat No-EPKJ0137 or equivelent of M-Seal/MS Seal/3M.
S&F Heat shrink straight through joint LT 1100 volts grade 185-300sqmm, 4 core including exacavation work complete all as specified and directed by Engr-in-charge. Make-Raychem, Cat No-EPKJ0144 or equivelent of M-Seal/MS Seal/3M.
S&F for GI tubing light grade 40mm bore,on pole /wall with necessary clamps,nuts,bolts and washers/under road cross ISI marked, for cable protection, complete all as specified and directed.
S&F for only GI tubing light grade 50mm bore on pole /wall with necessary clamps,nuts,bolts and washers/under road cross ISI marked, for cable protection, ISI marked, for cable protection, complete all as specified and directed.
S&F for GI tubing light grade 80mm bore,on pole /wall with necessary clamps,nuts,bolts and washers/under road cross ISI marked, for cable protection ISI marked, for cable protection, complete all as specified and directed.
S&F for jumper connections of length up to 1.50 mtr with existing size and guage of ACSR, binding with existing conductors for LT OH lines, complete all as specified and directed.
M&L for Danger notice plate of 1.6mm thick MS sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in singal red colour and fixed with MS clamps, bolts and nuts of approved size, for LT 1100 volts, 25cmX20cm size, complete all as specified and directed.
Painting both side of Iron angle fencing including iron gate after removing rust, loose paint, dirt ,scum or foreign matter and using two coats of same colour synthetic paint, complete all as specified and directed.
Labour for disconnecting LT/HT cable of any size from structure/pole/transformer for finding fault, M&L for defect rectification LT/HT cable laid in trenches or any location by liacting fault with the help of electronic fault machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc. The entire repair work to be completed with in 12 hours of instruction from Engr-in-charge as specified. Note:- Complaint will be notified to contractor on mobile phone at any time between 0800 to 2200 Hrs and has to be rectified with in 12 hours after notification, failing to which Rs 500/- per day complaint will be recoverd. fault locating with electronic fault locator, excavation and earth work, disconnecting and reconnecting both end of cable, relaying of sand and protective cable covers are deemed to be included in the quioted rate all as specified and directed by Engr-in-charge. Joint kit will be measured seperately in appropriate item in this schedule
Labour only for disconnecting LT/HT cable of any size from pole (height 7.5 to 9 mtr) /transformer/ panel and re-connecting of cable at both end after removing carbon /burnt insulation part of cable by cutting refixing cable with new cable lugs . The entire repair work to be completed with in 06 hours of instruction from all as directed by Engr-In-Charge. Note:- Complaint will be notified to contractor on mobile phone at any time between 0800 to 2200 Hrs and has to be rectified with in 06 hours after notification, failing to which Rs 500/- per day will be recoverd per complaint.
Labour only for disconnecting LT cable from Junction Box/TPN DB and opening of cable loop by exacavtion and re-connecting of cable of upto 35 sqmm size at both end after removing carbon /burnt insulation part of cable by cutting, refixing cable with new cable lugs including returning , filling including levelling of soil complete all as specified and directed by Engr-in-charge.
M&L for earthing complete with galvanised steel plate earth electrode 600X600X6mm thick buried directly in ground (earth pit not less than 2.25 meter below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to GI earth lead wire 4.0mm dia at two points by means of bolts and nut, check nut and washers including charcoal dust, common salt, necessary excavation in hard/dense soil, returning filling in and removal of surplus soil to a distance up to 50metres, PCC pit in 1:3:6 type CI (using 20mm grade stone aggregate) RCC 1:2:4 type B-1 (using 20mm grade stone aggregate ) 50mm thick pit cover, reinforced with 8mm dia TMT bars 75mm c/c, both ways MS handle 12mm dia, GI funnel, wire mesh and GI watering pipe of 20mm bore GI (light grade) and earth lead protection pipe 40mm bore (light grade) all as specified, directed and shown in electrical plate No 3 of SSR Part-I including testing complete. Note : GI strip and protection pipes 40 mm GI light grade up to 7.5 metre is included in unit rate and beyond that the same will be measured separately.
M&L for earthing complete with galvanised steel Earth plate electrode 600X600X6mm thick buried directly in ground (earth pit not less than 2.25 meter below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to GI strip 32x6 mm at two points by means of bolts and nut, check nut and washers including charcoal dust, common salt, necessary excavation in hard/dense soil, returning filling in and removal of surplus soil to a distance up to 50 metres, PCC pit in 1:3:6 type CI (using 20mm grade stone aggregate) RCC 1:2:4 type B-1 (using 20mm grade stone aggregate ) 50mm thick pit cover, reinforced with 8mm dia TMT bars 75mm c/c, both ways MS handle 12mm dia, GI funnel, wire mesh and GI watering pipe of 20mm bore GI (light grade) and earth lead protection pipe 40mm bore (light grade) all as specified, directed and shown in electrical plate No 3 of SSR Part-I including testing complete. Note : GI strip 32x6mm upto 7.5 metre with 40mm protection pipe shall be included in quoted rate and beyond that the same will be measured separately.
M&L for earthing complete with copper Earth plate electrode 600mmX600mmX6mm thick buried directly in ground (earth pit not less than 2.25 meter below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to copper strip 20x3mm at two points by means of bolts and nut, check nut and washers including charcoal dust, common salt, necessary excavation in hard/dense soil, returning filling in and removal of surplus soil to a distance up to 50 metres, PCC pit in 1:3:6 type CI (using 20mm grade stone aggregate) RCC 1:2:4 type B-1 (using 20mm grade stone aggregate ) 50mm thick pit cover, reinforced with 8mm dia TMT bars 75mm c/c, both ways MS handle 12mm dia, GI funnel, wire mesh and GI watering pipe of 20mm bore GI (light grade) and earth lead protection pipe 40mm bore (light grade) all as specified, directed and shown in electrical plate No 3 of SSR Part-I including testing complete. Note : Copper strip 20x3mm upto 7.5 metre with 40mm protection pipe shall be included in quoted rate and beyond that the same will be measured separately.
S&F for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20mmx3mm GI strip, complete all as specified and directed.
S&F for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32mmX6mm galvanised iron strip, complete all as specified and directed.
S&F for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20mmX3mm copper strip, complete all as specified and directed..
S&F for MCCB, 4 pole, 36 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 400 amps, incl dismentling taking down unsv one, complete all as specified and directed. Make- Legrand Cat Part No 4220-07 or equivelent model of Schneider/ABB/Merlin Gerin.
S&F for MCCB, 4 pole, 36 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 320 amps, incl dismentling taking down unsv one, complete all as specified and directed. Make- Legrand Cat Part No 44220-06 or equivelent model of Schneider/ABB/Merlin Gerin.
S&F for MCCB, 4 pole, 36 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 250 amps incl dismentling taking down unsv one, complete all as specified and directed. Make- Legrand 4202-19 or equivelent model of Schneider/ABB/Merlin Gerin.
S&F for MCCB, 4 pole, 36 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 200 amps incl dismentling taking down unsv one, complete all as specified and directed. Make- Legrand 4202-18 or equivelent model of Schneider/ABB/Merlin Gerin.
S&F for MCCB, 4 pole,36 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 160amps, incl dismentling taking down unsv one, complete all as specified and directed. Make- Legrand cat Part No 4200-57 or equivelent model of Schneider/ABB/Merlin Gerin.
S&F for MCCB, 4 pole,36 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 125 amps, incl dismentling taking down unsv one, complete all as specified and directed. Make- Legrand cat Part No 4200-56 or equivelent model of Schneider/ABB/Merlin Gerin.
S&F for MCCB, 4 pole,36 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 100 amps, incl dismentling taking down unsv one, complete all as specified and directed. Make- Legrand cat Part No 4200-55 or equivelent model of Schneider/ABB/Merlin Gerin.
S&F for MCCB, 3 pole, 36 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 320 to 400 amps, incl dismentling taking down unsv one, complete all as specified and directed. Make- Legrand Cat Part No 4220-01 & 02 or equivelent model of Schneider/ABB/Merlin Gerin.
S&F for MCCB, 3 pole, 36 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 250 amps, incl dismentling taking down unsv one, complete all as specified and directed. Make- Legrand Cat Part No 4202-09 or equivelent model of Schneider/ABB/Merlin Gerin.
S&F for MCCB, 3 pole, 36 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 200 amps, incl dismentling taking down unsv one, complete all as specified and directed. Make- Legrand Cat Part No 4202-08 or equivelent model of Schneider/ABB/Merlin Gerin.
S&F for MCCB, 3 pole,36KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 160 amps, incl dismentling taking down unsv one, complete all as specified and directed. Make- Legrand Cat Part No 4202-47 or equivelent model of Schneider/ABB/Merlin Gerin.
S&F for MCCB, 3 pole,16KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 125 amps, incl dismentling taking down unsv one, complete all as specified and directed. Make- Legrand Cat Part No 4200 46 or equivelent model of Schneider/ABB/Merlin Gerin.
S&F for MCCB, 3 pole,16KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 40amps, incl dismentling taking down unsv one, complete all as specified and directed. Make- Legrand Cat Part No 4200 45 or equivelent model of Schneider/ABB/Merlin Gerin.
Repair to any type of LT panel with cutting necessary worn out portion of MS sheet, providing MS sheet of 2mm, MS angle iron of existing size and hinges to broken door etc fixed with electric arc welding, providing external locking arrangement after taking proper elctric shutdown, complete all as specified and directed.
Contract Amount shall be derived after deducting the amount of Schedule of Credit in General Summary on serial page No 17 of tender documents.
MAJOR REFREGERATION AND ELECTRICALS (BID ID -3119673)
BHADU BUILDERS (BID ID -3119485)
DASHMESH ENTERPRISES (BID ID -3114883)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .