Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.7 LAccepted-AOC HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L1 | Accepted-AOC Tender accepted due to lowest and reasonable rates | |
| 2 | L2₹14.9 L+₹1.2 L (8.61%)Rejected-Finance 403 GH MANSADEVI COMPLEX PANCHKULA 134109 HARYANA | PANCHKULA | HARYANA | 134109 | L2 | Rejected-Finance Higher side quoted amount | |
| 3 | L3₹18.6 L+₹4.8 L (35.3%)Rejected-Finance AWANTA BHAWAN SOURA SRINAGAR 190011 J K | SRINAGAR | JAMMU AND KASHMIR | 190011 | L3 | Rejected-Finance Higher side quoted amount | |
| 4 | L4₹20.4 L+₹6.7 L (48.6%)Rejected-Finance | L4 | Rejected-Finance Higher side quoted amount | |
| 5 | L5₹23.1 L+₹9.3 L (67.9%)Rejected-Finance | L5 | Rejected-Finance Higher side quoted amount |
Tender Value
₹19 L
EMD Value
₹38,000
Closing Date
30 Aug 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Khumbathang
HQ CWE Khumbathang Pin 900270 C/o 56 APO
REPAIR MAINT OF CENTRAL HEATING PLANT AND STAND ALONE CHS AND OTHER ALLIED CONNECTED WORKS INSTALLED AT NIMU UNDER AGE(I)NIMU
2023_MES_611443_1
80051/38/E8
Open Tender
Support/Maintenance Service
Item Rate
180 days
Nimu
Class E, Cat c (i)
8 documents required · 8 mandatory
₹500
AGE (I) Nimu
₹38,000
Yes
20 Dec 2023
1 Aug 2023
31 Aug 2023
1 Aug 2023
30 Aug 2023
16 Aug 2023
Amount
Material and labour for attending of complaint for day to day maintainence / daily complaints by checking the serviceability of fan coil unit of any capacity for having continuous sreviceability of FCU for any number of time as desired by Engr-in-Charge including replacement of minor spare part like Gasket, Teflon tape, flare nut, tightening of any loose glycol line connections, shifting FCU from one place to another place if required, heating up the freezed glycol line anywhere about the premices to have continuous flow of glycol fluid, stopping any kind of leakage from any size of pipe line, tightening the loose electrical connections as related with FCU / Heating system, cleaning the air filter including radiator of FCU to the entire satisfaction of Engineer-in- Charge all as directed at site
Note :- (i) Attending any complaints of different nature in a single day in 24 Rajput Plant Room inside / outside will be considered as one job. ii) Any kind of replacement of major items shall be measured and paid for separately under respective item of BoQ iii) . Any nature of complaint related with FCUs, radiators, bursting/cracking/leakage of MS pipe lines, replacement of valves etc will be completed round the clock by suitable trademen (welder with suitable T & P), (including portable heating materials)-01, Skilled mechanic of CHS-01, Plumber/Fitter with helper-each o1, Supervisor-01 as per directions of Engineer-in- Charge.
S&F in replacement of fan coil unit 1.5/2 Ton duel shaft electric motor 30 watt 930 RPM, 3 speed as per existing make, complete all as specified and directed.
S&F in replacement of radiator unit of FCU 1.5 Ton including connecting with the unit and making it leakproof of copper coils covered with aluminium finishing as per existing size of capacity 3000 K Cal / Hour complete all as specified and directed.
S&F in replacement of radiator unit of FCU 2 Ton including connecting with the unit and making it leakproof of copper coils covered with aluminium finishing as per existing size of capacity 6000 K Cal / Hour complete all as specified and directed.
Fixing only fan coil unit 1.5 Ton as per existing connection complete all as specified and directed. Note:-The material will be issued under Sch 'B' free for fixing.
Fixing only fan coil unit 2 Ton as per existing connection complete all as specified and directed. Note:-The material will be issued under Sch 'B' free for fixing.
M&L for Dismantling of burner assembly at OTM-I Nimmu plant room CHS and removing of side cover and repairing the same by removing the old burnt fire refractory cement plastering, replastering the same as per existing fire refractory cement for boiler capacity 6 lakh Kcal/hrs and complete servicing the boiler by removing the complete carbon/oil deposits with suitable coil shine chemical including repair to coil assembly by welding, if there is any leakage found or any other repair required at site, and reassembling/ testing the same, complete all as specified and directed.
All as per srl item No. 7 here-in-before but for 4 Lakh Kcal/hrs at OTM-I, complete all as specified and directed.
M&L for dismantling of Glycol based electrical operated central heating boiler of capacity 75 KW of capacity 75000 Kcal/hrs by unscrewing and removal of heater side/end plates, with scalent de-carbonizing, scraping out carbon ,dirt acculated in heater, overhauling, servicing incl re-assembling all the dismantled component to its original position with testing and commissioning, Complete all as specified and directed by Engineer-in-Charge.
M&L for dismantling Standalone air heater for space heating of capacity 50000 Kcal/hr by unscrewing and removal of heater side/end plates, with scalent de-carbonizing, scraping out carbon ,dirt acculated in heater, overhauling, servicing incl re- assembling all the dismantled component to its original position with testing and commissioning, Complete all as specified and directed by Engineer-in-Charge.
M&L for dismantling of the blower motor of Stand alone air heater for space heating of capacity 50000 Kcal/Hr incl rewinding of blower motor with suitable size/gauge of copper wire including replacement of suitable blower fan sweep and blower fan guard and refixing of the same after varnishing, Complete all as specified and directed by Engineer-in-Charge.
M&L for rewinding of electric motor 3 phase 415 volts of capacity 7.5/10 HP with superior quality super enameled copper winding wire of appropriate size and gauge as existing including varnishing , cotton tape, PVC sleeves etc, including taking down and Re fixing, complete all as specified and directed.
M&L for servicing to the glycol pump and motor of capacity 7.5/10 HP, 2870 RPM including replacement of bearings, oil seals or any other spares / work required for smooth functioining of pump, complete all as specified and directed. Note - Major items replaced shall be measured and paid separately under respective item of BoQ and fixing of part rate also included.
Supply only Ball Bearing of suitable size
Supply only Oil seal /Gland
Supply Only Air circulation Fan (Plastic)
Supply Only Impellers
M&L for rewinding of electric motor single phase 230 volts of capacity 01 HP with superior quality super enameled copper winding wire of appropriate size and gauge as existing including varnishing , cotton tape, PVC sleeves etc, incl taking down and Re fixing. Complete all as specified and directed.
M&L for servecing to the glycol make up pump and motor of capacity 01 HP, 2870 RPM including replacement of bearings, oil seals or any other spares / work required for smooth functioining of pump, complete all as specified and directed. Note - Major items replaced shall be measured and paid for separately under respective item of BoQ and fixing of part rate also included..
Supply only Ball Bearing of suitable size
Supply only Oil seal /Gland
Supply Only Air circulation Fan (Plastic)
Supply Only Impellers
S&F in repair sequence controller suitable for 6 lakh Kcal/hr for LAL 2.25 burner rod assembly, complete all as specified and directed.
S&F in repair sequence controller suitable for 4 lakh Kcal/hr for LAL 2.25 burner rod assembly, complete all as specified and directed .
S&F in replacement of ignition rod suitable for 06 lakh Kcal/hr for burner rod assembly as per sample complete all as specified and directed.
S&F in replacement of ignition rod suitable for 04 lakh Kcal/hr for burner rod assembly as per sample, complete all as specified and directed.
S&F in replacement of ignition Transformer electronic type suitable for 6 lakh Kcal/hr for burner rod assembly as per sample complete all as specified and directed.
S&F in replacement of ignition Transformer electronic type suitable for 4 lakh Kcal/hr for burner rod assembly as per sample complete all as specified and directed.
S&F in replacement temp controller digital type DTC 503 with sensor suitable for 6 lakh Kcal/hr for LAL 2.25 burner rod assembly, complete all as specified and directed.
S&F temp controller digital type DTC 503 with sensor suitable for 4 lakh Kcal/hr for LAL 2.25 burner rod assembly, complete all as specified and directed.
S&F in replacement of pressure gauage 4" dial 0 to 10 Kg/Sqcm as per existing, complete all as directed by Engineer-in-Charge.
S&F in replacement of digital type volt meter 0-500 volts, complete all as specified and directed.
S&F in replacement of photo cell as per existing suitable for 6 lakh Kcal/hr for burner rod assembly, complete all as specified and directed.
S&F in replacement of photo cell as per existing suitable for 4 lakh Kcal/hr for burner rod assembly, complete all as specified and directed.
S&F in replacement of digital type Amp meter complete with suitable CTs 0-300 Amps, complete all as specified and directed.
S&F in replacement of indicating lamps RYB as per existing complete all as specified and directed.
S&F in replacement of rotary type ON/OFF switches, 22mm dia as per existing, complete all as specified and directed.
S&F in replacement of DOL starter MK-1, 7.5/10 HP as per existing, complete all as specified and directed.
S&F in replacement exhaust fan made of steel body complete with frame, voltage 230V, 50 Hz, RPM 1200, of sweep 380/400mm complete as specified and directed.
Cleaning of MS diesel storage tanks of capacity 1000 Ltrs by removing of sludge from tanks and scrapping the side walls by means of wire brush or emery paper and wash the same with caustic soda and clear water and painting the internal wall with two coats of black rubber emulsion paint and painting the complete tank from out side with two coats of synthetic enamel paint, complete all as specified and directed.
S&F in replacement of PVC flexible copper multistrand wire 3 core of 2.5 sqmm as per existing, complete all as specified and directed.
S&F in replacement of burner nozzle suitable for 6 lakh Kcal/Hr complete all as specified and directed.
S&F in replacement of burner nozzle suitable for 4 lakh Kcal/Hr complete all as specified and directed.
S&F in replacement of Electrode suitable for burner of capacity 6 lakh Kcal/Hr complete all as specified and directed.
S&F in replacement of Electrode suitable for burner of capacity 4 lakh Kcal/Hr complete all as specified and directed.
S&F in replacement of High pressure fuel pipe 1.5 mtr length as per existing, complete all as specified and directed.
S&F in replacement of FCU connection flexible pipe 20/16 mm as per existing, complete all as specified and directed.
S&F in replacement insulation 13mm as per existing, complete all as specified and directed.
S&F in replacement of plug top 15/5 Amps as per existing, complete all as specified and directed.
S&F in replacement of gun metal butter fly control valves of 100 mm bore, complete all as specified and directed.
S&F in replacement of gun metal butter fly control valves of 80mm bore , complete all as specified and directed.
S&F in replacement of gun metal butter fly control valves of 40/50mm bore , complete all as specified and directed.
S&F in replacement of inlet outlet Ball valve 3/4" with stainer for FCU, including supply and fixing MS / GI nipple of size 3/4 inch includig welding work including cutting the existing rusty unserviceable MS/GI nipple complete all as specified and directed.
M&L for repair of exaust pipe of boiler/MS pipe by welding, complete all as specified and directed by Engr-in-Charge.
S&F closed cell elastometric insulation 30 to 40 Kg/Cub mtr density 19 mm thick (nitrile insulation) complete all as specified and directed.
S&F in replacement of auto air pressure valve 3/8" as per existing, complete all as specified and directed.
Supply and filling of Mono Ethylene Glycol (MEG) of 99% purity and having freezing temperature less than -40° in Central heating plant installed at OTM-II Nimmu all as specified and direced by Engineer-In- Charge.
Supply and laying, connecting , fixing in repair/replacement including taking out the existing pipe and testing of MS ERW 'C' class piping 65 mm bore pipe, complete with fittings, duly insulated with 13mm thick closed cell elastomeric insulation 30 to 40 Kg/m3 density for the hot Glycol fluid pipes.(Note:-The pipes shall be provided with 24 SWG aluminium cladding over the insulation for exposed piping only and underground pipe shall be till 1.5m in depth)
All as per srl item No.59 here-in-before but 50 mm bore pipe with 13mm thick nitrile insulation.
All as per srl item No.59 here-in-before but 40 mm bore pipe with 13mm thick nitrile insulation.
All as per srl item No.59 here-in-before but 32 mm bore pipe with 13mm thick nitrile insulation.
All as per srl item No.59 here-in-before but 25 mm bore pipe with 13mm thick nitrile insulation.
All as per srl item No.59 here-in-before but 20 mm bore pipe with 13mm thick nitrile insulation.
M&L for replacement of MS pipes 80mm bore, heavy grade in any length laid in trenches pressure testing, welding of pipe, washing out complete including dismantling, taking out old corroded pipe line including all fittings complete all as specified and as directed by Engineer-in-Charge
All as per srl item No.60 here-in-before but 100mm bore pipe
All as per srl item No.60 here-in-before but 150mm bore pipe
Excavatoin in trenches not exceedng 1.5 mtr wide but exceeding 1.5 mtr in depth for laying of pipe and getting out all in hard and dence soil.
Returning filling in including spreading watering and well ramming in layer not exceeding 25mm thick in hard dence soil
Removing excavated material (soil) to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above starting point.
Note:-The accepted amount will be arrived after deducting the Sch of credit i.e. Rs 21,024.00 and any other reduction if any from quoted amount.
EESSI
EVERGREEN GROUP OF INDUSTRIES
CHHIRPON BUILDERS
Takshos Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .