| 1 | L1₹23.9 LAccepted-AOC | L1 | Accepted-AOC Accepted due to L1 | |
| 2 | L2₹24.5 L+₹54,809.60 (2.29%)Rejected-AOC | L2 | Rejected-AOC higher rate | |
| 3 | L3₹24.9 L+₹97,347.64 (4.07%)Rejected-AOC 13 218 MASJID EXTEN SADAR BAZAR | L3 | Rejected-AOC higher rate | |
| 4 | L4₹25.8 L+₹1.9 L (7.77%)Rejected-AOC FLAT NO 602 THE ELEPHANT HEAD CGHS LTD PLOT NO 41 OPP AYUSHMAN HOSPITAL DWARKA SECTOR 10 SOUTH WEST DELHI 110075 | SOUTH WEST | DELHI | 110075 | L4 | Rejected-AOC higher rate | |
| 5 | L5₹30.7 L+₹6.7 L (28.1%)Rejected-AOC | L5 | Rejected-AOC higher rate |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
23 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NEW DELHI
GE NEW DELHI
CA NO GE/ND-73/2022-23 REPAIR/MAINT OF EXTERNAL ELECTRIC SUPPLY IN NAVY AREA UNDER GE NEW DELHI
2022_MES_565291_1
GE/ND-73/2022-23
Open Tender
Civil Works
Item Rate
270 days
GE NEW DELHI
REFER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE NEW DELHI
₹60,000
Yes
31 Mar 2023
25 Nov 2022
26 Dec 2022
25 Nov 2022
23 Dec 2022
9 Dec 2022
Amount
Excavation in trenches in any type of soil not exceeding 1.5 mtr wide and not exceeding 1.5 metre in depth for laying of LT under ground cable/ GI pipe complete all as specified
Returning filling including spreading, levelling watering and well ramming in layers n. exc. 25 cm thick in any type of soil complete all as specified.
Removing excavated materials to a distance not exec. 50 mtr and deposing where directed at a level not exec 1.5 mtr above the starting point all as specified.
M&L for Best quality, locally available, sub class ‘B’ bricks (Old Size) for cable protection cover, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and as directed by Engineer-in-Charge.
Supply local sand cushioning , with dry and clean sand, over and under the under ground cables in trenches, ducts for cable protection including consolidation, 80mm thick to the authorized width as per SSR Part-I before laying of cable and 150mm thick after laying of cable complete all as specified and as directed
Laying only serviceable sub class ‘B’ bricks as retrieved from Srl item No 10 complete all as specified and directed by Engr-in-Charge.
M & L for excavation by trenchless boring technology for holes under road pavement, hard standing using ultra sound technique and engaging necessary machine suitable for 0.4 Mpa working pressure complete all as specified and directed Note:- marking good the disturbed surface shall deemed to be included in quoted rate.
Supply & Laying in replacement of XLPE LT cable 1100 volts grade heavy duty with XLPE insulated stranded aluminium conductor served with an inner sheathing of PVC Tape armoured with galvanized steel strip or wire and over all PVC Sheathed stranded conductor conforming to IS-7098 (Part-I) with latest amendments laid in tranches/fixed to wall/pole/laid in floor including necessary connections and suitable size of thimbling complete all as specified and as directed by Engineer-in-Charge of the following size:-. (Note : Excavation , earth work, sand cushioning , brick protection and pipe shall be measured and paid separately under appropriate item of this schedule)
(a) 25 sqmm 3.5 core
(b) 35 sqmm 3.5 core
(c) 50 sqmm 3.5 core
(d) 70 sqmm 3.5 core
(e) 95 sqmm 3.5 core
(f) 185 sqmm 3.5 Core
(g) 240 sqmm 3.5 Core
(h) 400 sqmm 3.5 Core
M&L for locating the fault in underground electrical power cable of any length & any type of 1100 grade LT cables, by arranging fault locating Machine & pin point the fault, cutting the cable at fault to fixing the joint including testing of the cable after locating fault and jointing cable including excavation and earth work in any type of soil complete all as specified and as directed. Note: (i) Jointing of cable shall be measured and paid separately under respective item of this Schedule. (ii) If fault is not rectified within 24 hours after receiving Message, the contractor shall be charged penalty for Rs 500/- per hour per complaint and shall be deducted from next payment due to contractor.
Supply , fixing testing and commissioning in replacement of cable joint kit for 1.1 KV grade cable for straight through joint heat shrinkable type joint complete with jointing material and accessories suitable for following size of XLPE/PVC aluminium conductor cable :-
25 to 35 Sq. mm cable of 3.5/ 4 core size
50 to 95 Sq. mm cable of 3.5core size
185 to 400 Sq. mm cable of 3.5 core size
Material & Labour for road cutting, including excavation, returning filling in, spreading, levelling well ramming in layers, soling with broken boulders/stones, WBM 7.5 cm thick coarse aggregate received from dismantling the existing road, premix, carpeting 25 mm thick using ready mix patch mate material, rolled and compacted for road patch repair work, complete all as specified and directed by Engr-in-Charge.
M&L for supply, erection, testing & commissioning of 8 metre high made out of 3 mm thick galvanized iron sheet hot dip octagonal street light pole in one segment with one longitudinal welding joint including galvanized MS sheet with window/door opening with one MCB SP 6 to 16 Amps & TPN connector block 40 Amps having flash cover including necessary earth work (excavation, returning filling & removal) in soft/loose soil, RCC (grade M20) in foundation as per recommended design of manufacturer considering safe soil bearing capacity at site including suitable size & minimum 04 Nos foundation bolts of minimum dia 22 mm & 750 mm long "J"-type along with nuts, washers, anchor plates and templates, 50 mm dia PVC pipe in foundation for entering cable complete including dismantling of PCC pole all as specified. The foundation details shall be as under:- (a) RCC foundation size below GL will be 600 mm x 600 mm x 1300 mm (depth) (minimum) and above GL shall be 300 mm high of same section. (b) Main reinforcement in RCC shall be 20 mm dia 8 Nos TMT steel bars in vertical and stirrups of 8 mm dia @ 190 mm c/c. ( c) Base plate and anchoring plate shall be of minimum size 225 x 225 x 16 mm thick. (d) RCC (grade M20) in foundation. (e) Anchoring bolts shall be of "J"-type 750 mm long and 22 mm dia MS rod. Make: Cat Pt No. HM-1109P of Crompton Greaves or equivalent in L& T/schneider
S&F of single arm bracket of minimum length 1.00 mtr, GI pipe duly fixed with necessary fixing arrangement complete all as specified.
S & F in replacement of aluminium busbar chamber indoor type with 200 Amps, TPN aluminium busbars for safe power distribution with provision of incoming and outgoing cables & including fixing accessories complete all as specified and directed by Engr-in-Charge.
S&F in replacement of ACB thermal release with pre-fabricated factory made tested with suitable retrofitting kit ACBs 4 Pole, 800A, Ics=Icu=Icw= 50kA (RMS) for 1 Sec, Manual draw-out type, front operated Air Circuit Breaker suitable for 415Volt, 3-Phase, 50Hz AC supply system, complete with microprocessor based protection release with over current, short-circuit protection, earth-fault protection, instantaneous protection and over temperature protection feature, the breaker shall have minimum breaking capacity of 50kA , 5NO/5NC auxiliary contacts, breaker shall have electrical interlocking with proper wiring, testing after installation making modifications in the existing LT Panel by suitable capacity of Bus Bar including dismantle/ dissembled (both fixed and moving parts) old ACB completely and replaced with latest series of circuit breakers complete all as specified and as directed. Make:-As per existing.
S&F in replacement of ACB thermal release with pre-fabricated factory made tested with suitable retrofitting kit ACBs 4 Pole, 1250A, Ics=Icu=Icw= 50kA (RMS) for 1 Sec, Manual draw-out type, front operated Air Circuit Breaker suitable for 415Volt, 3-Phase, 50Hz AC supply system, complete with microprocessor based protection release with over current, short-circuit protection, earth-fault protection, instantaneous protection and over temperature protection feature, the breaker shall have minimum breaking capacity of 50kA , 5NO/5NC auxiliary contacts, breaker shall have electrical interlocking with proper wiring, testing after installation making modifications in the existing LT Panel by suitable capacity of Bus Bar including dismantle/ dissembled (both fixed and moving parts) old ACB completely and replaced with latest series of circuit breakers complete all as specified and as directed. Make:-As per existing.
Notes for items No 19 & 20: (i) Work shall be carried out through authorised Rep of OEM i.e. Make- L&T or auth channel partner of Make- L&T only. The bidder has to confirm that use of retrofit will not downgrade performance of breaker and no heating will take place at breaker power terminals and bus bar contacts. Rates shall be including for the following scope of work all as specified and directed:-
(a) Retrofit kit should be ready before start the job at site and the current carrying path is made up of ETP copper/ aluminium. Time for shutdown of elect supply for each ACB panel will not more than 3-4 hours including installation & testing with complete retrofit kit arrangement on site. (b) The retrofit kit links should be directly connected to the existing bus bar terminals without any modification in the existing bus bar and the joints shall be TIN plated if required. The retrofit kit drill pitch should be in accordance with DIN standard.
(c) The cross-section area per phase of the retrofit kit shall be capable to carry the rated uninterrupted current of ACB (lu) without any derating factor. The bus bar support arrangement shall be designed in such a way that it can withstand the fault level equivalent to icw fault of ACB for 1 second. (d) Dismantling to old breaker and cradle including replacement of necessary hardware including modification in the control wiring and interconnections shall be as per original schematics.
(e) Dismantling from cables connected to bus-bars and connection of old outgoing cables & interlocking the new links with old bus bars including removing of existing cradle & installing new one. (f) Modification of existing panels/doors /breaker bus - bus bar arrangements/cubicles/wiring/schematic interconnections with other sections of the panel with similar shade of paint to complete panel. (g) After insertion of new breaker, testing of the installation with megger and final testing of ACB with switching & tripping. (h) The cost shall be included for all T&P tackles required for installation, testing and commissioning shall be provided by the deptt.
Disconnecting HT supply and taking out ACB of any make and rating 630 Amps to 1250Amp and servicing by cleaning the fix and moving parts, removing dust particles by using high speed blower applying grease / jelly to moving mechanism and moving parts, tightening nut bolts of all the components of ACB and replacement of all unserviceable spares as required, testing commissioning and putting on the supply on load and testing with VI injecting instrument for full load test/calibration for work efficiently in the tripping circuit complete all as specified and directed by Engr-in-Charge. Note:- (i) Servicing/repairs shall be carried out by authorised service engineer only. (ii) Spares as required for replacement shall be of the same company as of existing make or as recommended by the Engr-in-charge. (iii) All Measuring equipment and T&P required shall be arranged by the contractor. (iv) any other activity/ minor items not listed/covered here and required during /completing the work for smooth functioning of system will have to be arranged by Contractor himself and for this purpose no extra cost will be paid. (v) Major Spare parts shall be paid separately under relative item as supply only. However fixing charges shall deemed to be included in this item (vi) A sum of Rs. 5000/- will be recovered from the contractor for non rectification of breakdown/fault or replacement of any unserviceable spares after 12 hours from lodging of complaint telephonically or verbally. (vii) Thereafter Rs. 1000/- will be added every day till rectification of fault or replacement of unserviceable spares complete all as specified and directed by Engr-in-Charge.
S&F in repair Earth Fault protection relay for ACB of capacity 1000 Amps complete all as specified and as directed.
S&F in repair 3 Phase Digital Ammeter including wiring from CT to meter and Bus bar complete all as specified and as directed. Make: As per existing
S&F in repair CT 630/5A CL-1 15VA Burden complete all as specified and as directed.
S&F in repair CT 1000/5A CL-1 15VA Burden complete all as specified and as directed.
S&F in repair LED Phase Indication Light (set of three) and its connection complete all as specified and as directed.
S&F in repair ON/OFF/Trip/ Ready to close indication including fixing charges and required wiring for ACB 's complete all as specified and as directed.
S&F in repair Breaker Control Switch (TNC) to operate ACB's including fixing charges and required wiring for ACB's complete all as specified and as directed.
S&F in repair Control MCB SP of suitable rating for Indication Light including fixing charges and required wiring for ACB's complete all as specified and as directed. Make: Legrand Cat 4085 83 or equivalent Model of Make mentioned in PS.
Supply only in replacement manual charging handle suitable for LT ACB of any make and rating 630 Amps to 1250 Amps as per existing make and model complete all as specified and directed by Engr-in-Charge.
Supply only in replacement UVR under voltage release coil assembly suitable for LT ACB of any make and rating 630 Amps to 1250 Amps as per existing make and model complete all as specified and directed by Engr-in-Charge.
Supply only in replacement Racking inter lock complete suitable for LT ACB of any make and rating 630 Amps to 1250 Amps as per existing make and model complete all as specified and directed by Engr-in-Charge.
Supply only in replacement fixed/moving arching contacts suitable for LT ACB of any make and rating 630 Amps to 1250 Amps as per existing make and model complete all as specified and directed by Engr-in-Charge.
Supply only in replacement CT's of suitable ratio for LT ACB of any make and rating 800 Amps to 2500 Amps as per existing make and model complete all as specified and directed by Engr-in-Charge.
Supply only in replacement circuit draw out terminals suitable for LT ACB of any make and rating 800 Amps to 2500 Amps as per existing make and model complete all as specified and directed by Engr-in-Charge.
S & F in replacement of Heavy Duty Power Factor Improvement Capacitors BANK Stud Mounting Cylindrical type, 440 volts, 50 Hz, 3 phase, delta connected of following capacity:- Make:- EPCOS/Havells/Legrand.
S & F in replacement Power Contactor of rating 70 Amps AC3, 3 pole 415 V suitable for operating of time switch Make C&S or L&T (ML-4)/HPL
S & F in replacement Power Contactor of rating 40 Amps AC3, 3 pole 415 V suitable for operating of time switch Make C&S or L&T (ML-3)/HPL
S & F in replacement Power Contactor of rating 25 Amps 220 volts 3 pole suitable for operating of time switch Make C&S or L&T (ML-1.5)/HPL
S&f In replacement of MCCB, 4 pole, 415 volt of capacity 100 amp, Ics=100% Icu, adjustable thermal setting 80-100% with breaking capacity 16 KA all as specified Make-As per existing.,
All as per Srl item No. 46 here-in-before but 63 Amps breaking capacity not less than 36 KA
All as per Srl item No. 46 here-in-before but 160 Amps breaking capacity not less than 36 KA
All as per Srl item No. 46 here-in-before but 250 Amps breaking capacity not less than 36 KA
All as per Srl item No. 46 here-in-before but 630 Amps breaking capacity not less than 50 KA
All as per Srl item No. 46 here-in-before but 4 pole 250 Amps breaking capacity not less than 36 KA
All as per Srl item No. 46 here-in-before but 4 Pole 630 Amps breaking capacity not less than 50 KA
All as per Srl item No. 46 here-in-before but 3 Pole 63 Amps breaking capacity not less than 16 KA
All as per Srl item No. 46 here-in-before but 3 Pole 100 Amps breaking capacity not less than 16 KA
All as per Srl item No. 46 here-in-before but 3 Pole 125 Amps breaking capacity not less than 16 KA
All as per Srl item No. 46 here-in-before but 3 Pole 160 Amps breaking capacity not less than 36 KA
All as per Srl item No. 46 here-in-before but 3 pole 200 Amps breaking capacity not less than 36 KA
All as per Srl item No. 46 here-in-before but 3 pole 250 Amps breaking capacity not less than 36 KA
All as per Srl item No. 46 here-in-before but 3 Pole 400 Amps breaking capacity not less than 36 KA
S&F in replacement MCB TPN/ Isolator 4P from 63 Amps 415 volts, 'C' Series 10 KA as per site requirement and as directed of approved make. (Make : Legrand/ABB/Crabtree)
S&F in replacement MCB TPN/ Isolator 4P from 100 Amps 415 volts, 'C' Series 10 KA as per site requirement and as directed of approved make. (Make : Legrand/ABB/Crabtree)
S&F in replacement MCB TP 3P from 63 Amps 415 volts, 'C' Series 10 KA as per site requirement and as directed of approved make. (Make : Legrand/ABB/Crabtree)
S&F in replacement of decorative LED type post top lanterns luminaire 40 watts, out door type for 360 degree indirect light with resistant to corrosion, glare free having better uniformity complete with suitable driver all as specified. Cat pt No. LPTO-40/CDL of Crompton Greaves make or equivalent in Philips/Havells
S&F in replacement of ARCHNER LED type post top light 45 watts, PDC aluminium housing with opal diffuser, IP- 65 protection ,input voltage 140-270 Volt, 50 HZ ,Total hormonic distortion less than 10%,CCT- warm white and power factor greater than 0.95 out door type complete with GI decorative light pole of suitable length and size with necessary foundation for fixing the light pole all as specified. Cat pt No for light:-BGCPNP 45 W LED WW of Bajaj make or equivalent in Philips/Crompton.
S&F LED bollard luminaire 10 watts, inverted pyramid tripod type with soft 360 degree light out door type having resistant to corrosion with better optics for uniform distribution complete with suitable driver & fixing nuts, bolts & washers all as specified. Cat pt No LBLSN-10CDL of Crompton Greaves or equivalent in Philips/Havells
S & F LED flood light luminaires 40 watts, 230 volts AC, out door type with pressure die cast aluminium housing resistant to impact and corrosion, glare free complete with lamp, driver complete all as specified. Make: CG Philips/Havells .
S & F LED flood light luminaires 90 watts, 230 volts AC, out door type with pressure die cast aluminium housing resistant to impact and corrosion, glare free complete with lamp, driver complete all as specified. Make: CG or equivalent in Philips/Havells .
S&F LED flood light luminaires 120 watt , 230 volt AC, out door type with pressure die cast aluminium housing resistant to impact and corrosion, glare free complete with lamp, driver complete all as specified. Make:Philips/Havells/CG
S & F in replacement of Integral aviation obstruction light luminaires comprising of aluminium housing with polycarbonate encloser including 230 volts, 50 Hz red coloured complete with all fixing accessories including minimum 01 RM medium grade GI tube of 25 mm bore with suitable reducer & suitable PCC foundation and all standard accessories all as specified. Make: Bajaj/Philips/Wipro.
S&F in replacement of LED Street light fitting 45 Watt Highly efficient made of pressure die cast aluminium housing with lens & toughened glass in replacement of old unserviceable conventional security light fitting including fixing material i.e. MS clamp, Nut and bolt, anchor fastener washer etc complete all as directed . Make Havells/CG/Philips).
S&F in replacement of LED Street light fitting 120 Watt Highly efficient made of pressure die cast aluminium housing with lens & toughened glass in replacement of old unserviceable conventional security light fitting including fixing material i.e. MS clamp, Nut and bolt, anchor fastener washer etc complete all as directed . Make Havells/CG/Philips).
S&F in replacement of LED Street light fitting 135 Watt Highly efficient made of pressure die cast aluminium housing with lens & toughened glass in replacement of old unserviceable conventional security light fitting including fixing material i.e. MS clamp, Nut and bolt, anchor fastener washer etc complete all as directed . Make Havells/CG/Philips).
S & F in replacement of ornamental street light 120 Watt, 230 Volt AC ,outdoor type with spun aluminium designer housing with clear acrylic for city beautification with IP 65 protection all as specified and directed by Engineer-In-Charge Cat No HLOSL-04-120-CWL or equivalent model in CG/Havells/Philips.
Supply and fix sports light fitting 480 watt LED complete with suitable bracket , and fixing arrangement like bracket clamp of Philips cat part No:-BVP621 LED504/CW 480W 220-240V NB GM or equivalent to Havells/CG.
S&F in replacement of LED driver having input voltage as 200-260 Volts AC 50 HZ & output voltage as 12 Volt DC Suitable upto 120 watt LED Fitting driver fixed in & suitable size thermoplastic box having IP protection complete including making proper electric connection complete all as specified Make as per sample
S&F in replacement of LED Fountain light 27 Watt water proof ,adjustable type IP 67 complete with stainless steel housing toughened glass LED lens of multicolour including necessary nut, bolt, anchor, fastner, washer etc complete all as specified and directed.
Supply & fix in replacement of SS fountain nozzle of suitable size (as per sample) for fountain outer ring all as specified and directed by Engr-In-Charge.
M&L for painting of steel tubular pole after Cleaning and scraping with wire brush complete with two coat of aluminium paint over a coat of red oxide primer and applying one coat of cement base paint on PCC coping complete all as directed
supply and fix in replacement of decorative post top 40 Watt LED light pole with suitable length and size along with suitable foundation and nut bolts for fixing the pole and refix the light on newly mounted pole including taking down old rusted/broken pole of any type all as specified and directed by Engr-In-Charge.
Material and labour for refixing/rearranging the12 M High mask light pole top circular symmetry which consist the LED lights to its original position by using suitable T&P and expert labour and Supply of raising lowering system comprising double drum winch, 6mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box, lightning finial and replacement of unserviceable Flood lights. Note:- (i) Flood light shall be measured and paid separately under respective item. (ii) Wiring material from JB to individual luminaries & MCB in base compartment are also included in this section (iii) The quoted rates are inclusive of hydra machine required for rearranging the circular symmetry.
M& L for Painting of LT Panel of any sizes after cleaning and scraping old paint with wire brush with two coat existing paint over a one coat of red oxide primer by using spray gun and applying one coat of cement base paint on PCC foundation complete all as directed
M& L for Painting of decorative security light poles of any sizes after cleaning and scraping old paint with wire brush with two coat existing colour paint over a one coat of red oxide primer by using spray gun and applying one coat of cement base paint on PCC foundation complete all as directed
Taking out complete 8 Mtr street light pole along along with street light fitting from existing site and refixing the same pole with new foundation concrete , including grouting with new nut bolts, and refixing/reconnecting the street light after completion of fixing of pole work complete all as specified and directed by Engr-in -Charge
S&F in replacement cable PVC insulated, multi stranded, unsheathed 1100 volts, three core copper conductor of size 2.5 sqmm drawn in pole/post/conduit all as specified.
S & F in replacement of PVC conduit pipe 25mm including clamps, Nut, Bolts complete all as specified & directed
M & L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI strip 25X4 mm up to 7.50 RM bolted (with GI nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board / test point at the other and watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 40 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh etc including necessary excavation and earth work in any type of soil, returning filling in and removal of surplus soil all as specified.
Material and labour for design, development, commissioning & testing EHCC certified ground tubular effective earthing system to give earth resistance less than 2 ohm ,hollow tube solid bar (CPRI tested for 15 kA current capacity for LT line) highly anticorrosive long life electrode with and including adequate protective coating to withstand severe wear conditions in the earth pit and of size std medium grade GI tube outside secondary conductor of 80mm dia and main primary conductor inside of 25x4mm copper strip 3000mm length ready to install with suitable connecting terminal confirming to IS: 3043:1987 specification highly conductive packing material to be filled in earth pits for providing uniform low resistivity anticorrosive hygroscopic medium around the earth system for improving the efficiency of current dissipation 25 Kg per bag (3 bag per kit) min or sufficient quantities required as per site complete including main copper earthing lead of size 25x6 mm up to 7.50 metre to connect with equipment and including PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate pit chamber with FRP pit cover of size 0.30x0.30x0.30m and cutting of rocks if available at site in a rocky area including necessary earth work in any type of soil complete all as specified. Make of chemical:-Erove or equivalent
M&L Earth continuity conductor fixed to wall or buried on ground or any other indicated situation for loop earthing etc with Aluminium strip of size 25x4mm mm all as specified and directed .
Disconnecting electrically switch boards/ electric panels/ distribution boards of any size by taking proper electric shut down, opening cables from MCCBs/DBs/main switches/panels, cutting of unserviceable/overheated cable ends/ thimbles etc, fixing of new aluminium thimbles suitable for LT cable size up to 400 sqmm x 3.5 core as required at site, insulation of all necked wires as per existing colour code, re-fixing/re-assembling as per existing complete all as specified and directed by Engr-in-Charge. Note: Thimbles shall be measured and paid separately under respective item.
Supply, fabricate, install, testing and commissioning in replacement LT control panel outdoor type powder coated, weather proof, dust proof, vermin proof made out of 3.15 mm thick CRCA sheet front openable door, angle iron frame and locking arrangement with pad lock, and fixed on raised PCC platform with PCC 1:2:4,type B1 (20mm graded aggregate) raised base with control wiring with comprising cable gland brass, copper lugs etc. including dismantling the unserviceable panel and compressing the following. (i) Off load Changeover switch 100 Amps 4 Pole, AC 50 Hz 440 Volt -01
Supplying, installation, testing and commissioning in replacement of LT panel 2.0 mm thick cubical indoor type weather proof, powder coated, totally enclosed with IP 65 protection made out of CRCA sheet angle iron of size 50 mm x 50 mm x 6 mm suitable for 3 phase, 440 volts, 50 Hz including cable glands, phase indicators, internal wiring, voltmeter, suitable size of CT's, ,ammeter, with proper spacing to accommodate to all control switches and other accessories, cable connections with suitable size of lugs/thimble etc and locking arrangement with two locks godown type welded inside of the shutter with duplicate keys, and mounted on two No bricks pillars including excavation and earth work complete PCC (1:2:4) brick work (1:4) and plastering complete. comprising of the followings
Note : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC platform incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge.
Supplying, installation, testing and commissioning in replacement of LT panel 3.15 mm thick cubical outdoor type weather proof, totally enclosed with IP 65 protection made out of CRCA sheet angle iron of size 50 mm x 50 mm x 6 mm suitable for 3 phase, 4 wire ,440 volts, 50 Hz including cable glands, phase indicators, internal wiring, CT of suitable Ratio, voltmeter, ammeter, air passing holes with proper spacing to accommodate to all control switches and other accessories, cable connections with suitable size of lugs/thimble etc and locking arrangement with two locks godown type welded inside of the shutter with duplicate keys, spray painting with two coats of light gray paint over a coat of red oxide primer and mounted on two No bricks pillars including excavation and earth work complete PCC (1:2:4) brick work (1:4) and plastering complete:-
Note : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC plat form incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge.
S&F in replacement Off load Changeover Switch 200 Amp,415 volts, 4 pole, 50Hz on load side handle operated type including taking down old change over complete all as specified and directed Make: Havells/L&T/Standard.
Supply, Installation, testing and commissioning in replacement of 4 Pole Automatic Transfer Switch (ATS) 400 Amps, 415 Volts, 50 Hz, automatic/manual type with inbuilt time delay complete with enclosure all as specified. Make: Havells/Equivalent
Supply, Installation, testing and commissioning in replacement of 4 Pole Automatic Transfer Switch (ATS) 630 Amps, 415 Volts, 50 Hz, automatic/manual type with inbuilt time delay complete with enclosure all as specified. Make: Havells/Equivalent
Supply, installation, testing and commissioning in replacement of 4 pole phase corrector unit 100 Amps, 415 Volts, 50 Hz, automatic/manual type with inbuilt time delay complete with enclosure all as specified. Make: Havells/Universal Switchgear Control/Sinetrac.
Shifting of bollard light from existing position and fixing on PCC foundation (1x1x1 ft) by grouting , Nut bolt and making arrangement in PCC and fixing iron box with bus bar for termination of cable all as specified and directed by Engr-in-Charge
S&F thermoplastic cable junction box with metric knock out for cable entry of size 200x160x98mm with 4 Nos of 200A aluminium busbar mounted on insulators, terminal and MCB 10A capacity including fixing with clamp 30x5mm iron flat, nuts, bolts and washer complete including providing of steel conduit of dia 32mm bore of length 1.60 mtr including earth work for taking out of cable and fixing complete all as specified and directed.
Supply only aluminium thimble ring/pin type of size 6 Sq. mm to 35 sq. mm all as specified
Supply only aluminium thimble ring/pin type of size 50 Sq. mm to 120 sq. mm all as specified
Supply only aluminium thimble ring/pin type of size 150 Sq. mm to 300 sq. mm all as specified
Taking out of unserviceable motor of high mask light pole and carrying out necessary repair work ,replacement of unserviceable spare parts and refix the motor to its original position, making all the connections properly and testing carried out upto satisfactory level of Engr-In-Charge by lowering and lifting the high mask light complete all as specified and directed.
S & F in replacement of Auto/ Manual switch for security light panel as per sample
S & F in replacement of timer MCX 31,4 pole, 240 Volt, 50 HZ for security light panel all as specified and directed by Engr-In-Charge.
S & F in replacement of HRC Fuse 20 Amps for security light panel all as specified and directed by Engr-In-Charge.
S & F in replacement of fuse 800 Amps for fuse box all as specified and directed by Engineer-In-Charge.
S&F in replacement Off load Changeover Switch 400 Amps, 415 Volt, 4 pole, 50Hz on load side handle operated type including taking down old change over complete all as specified and directed Make: Havells/L&T/Standard.
S.R. Constructions
verma enterprises
NEERU ELECTRICALS
Surjit and Sons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .