Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance INSIDE KL PARK W NO 37 IN MOGA CITY | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance ARRORIAN STREET DISTT PATIALA | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹36,430
Closing Date
2 Jul 2020, 5:00 pmClosed
Executive Engineer
WSS Division No. 3 SAS Nagar
Providing and Installing one no. New Tubewell of size 250x150mm I/d upto 300 mtr Depth with Reverse Rotary Rig in place of failed Tubewell for WSS Rassanheri, Block Kharar
2020_WSS_48776_1
4760-61 dt 15-06-2020
Open Tender
Drilling Works
Item Rate
90 days
SAS Nagar
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,000
Yes
TIA
₹36,430
Yes
20 Sept 2024
17 Jun 2020
3 Jul 2020
17 Jun 2020
2 Jul 2020
17 Jun 2020
Amount
Drilling of 650mm dia bore with reverse rotary rig in all kinds of soil including the cost of consumable stores, fuel oil and transportation of rig to the site. Complete in all respects.
Drilling of 650mm dia bore with reverse rotary rig upto 150 mtr depth BGL.
Drilling of 650mm dia bore with reverse rotary rig beyond 150 mtr depth upto 300 mtr depth
1. Erection and dismantling of boring plant including all arrangement for the transportation of the boring equipment to site of work from the store of contractor at site and back are to be made by the contractor at his own cost. All rates should be quoted for supplying the material at site of work. Pits for collection of Water and Water for drilling tube-well be arranged by the firm/ contractor at site at his own cost.
2. In case the bore is converted into a tube-well payment of bore shall be made up to the bail plug plus margin (7% of main bore drilling or as actual as per field requirement whichever is less) required for sustaining the main bore. The test bore beyond margin shall be paid at the rate of test bore drilling.
Making electric Logging of borehole with electronic well logger including cost of equipment at site etc. complete in all respect.
Supplying, lowering of MS Pipe as per IS:4270-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore.
250mm Nominal Diameter (Weight 52.3 kg/mtr) 8.00mm Thickness
150 mm Nominal Diameter (Weight 25.35kg/mtr) 6.30mm Thickness as per analysis attached
Supplying, fixing and lowering of stainless steel cage type wite wound screen as per, ISI 8110-2000 or latest ISI marked, duly welded with suitable grade SS welding electrode to lower the strainer into tubewell bore.
150mm internal diameter (slot size 0.75mm) 6.30 mm thickness
Supplying and fixing of bail plug of M.S pipe complete with inverted U-hook attached to the bottom plug Complete in all respects.
150mm internal diameter (weight 25.35kg/m) 6.30 mm thickness
Providing and fixing M.S. taper / reducer made out of 6 mm thick M.S. sheet complete in all respect.
Reducer 250mm x 150 mm
Supplying, fixing and lowering of stainless steel socket as per IS 8110-2000 or latest, ISI marked duly welded with suitable grade SS welding electrode to lower the strainer into tubewell bore complete in all respect.
150mm Internal Diameter
Supplying, lowering & fixing of M.S. special socket to connect S.S. Strainer to M.S pipe duly welded with suitable grade welding electrode complete in all respects.
150mm Internal Diameter
Supplying & Fixing of well cap having thread to fix on housing pipe complete in all respect.
250mm Internal Diameter
Supplying & fixing of M.S Clamp of size 150mm X 12mm made out of MS Flat 1.52m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect.
Supplying at site Wooden Box of suitable size with Lid & locking arrangement for preserving strata sample collected from the bore.
Supplying at quarry site of gravel of 1/16" to 1/8" sizes including pouring and packing in the annular space between the pipes assembly and the bore. The gravel should be free from, dust, dirt, or the vegetable manner as per IS 4097/1967 with latest amendments. (to be paid as per actual length of pipe)
Supplying and fixing Mild steel centering guide made out of 32mm x 6mm thick M.S. bar complete in all respects.
Collection of water sample from different strata and testing of sample from approved lab. (Physical and Chemical Analysis)
Testing of water sample for Heavy metal from approved laboratory (Aluminum, selenium, cadmium, chromium, lead, mercury, arsenic, nickel, pesticide & uranium etc.)
Development and Stabilizing of the tubewell with air compressor of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.
Capacity of Air compressor 550 cfm at 600 PSI
Development and Stabilizing of the tubewell with submersible pump of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.
Rising main
Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications including excavation.
110mm o/d pipe of 10kg/sqcm
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge)
Providing, Fixing & jointing Cast Iron Surface box for Sluice Valve, Air Valve, Fire hydrant etc. including all carriages complete @ 3Kg Each
Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health department (size 0.9m x 0.9m)
Chlorinator Plant
Providing, Installing, testing & commissioning one No. Electronically actuated, Diaphragm Operated, Metering System, Chemical Dosing Chlorinator, suitable for delivering 0.5 to 6 Litres of Bleaching Powder Solution/Sodium Hypo solution per hour under maximum delivery pressure up to 7 Kg.cm2, and suction lift not less than 1.5 m, as per DWSS standard specifications.
Pumping Machinery
Providing, installing, testing and commissioning of 1 no. Electrically driven pumping set of reputed make, capable of delivering 170 lpm against a head of 132 mtr (10.00 BHP) Complete in all respects
Supplying lowering of 80 mm dia GI pipe as per IS 1229 including GI sockets. Complete in all respects
Providing and fixing of submersible of 4 mm ² core cable, complete in all respect
Providing installing, testing and commissioning of 1 no. Software Based DOL (Direct Online) Smart Motor Control Panel (EC/WS) electricity & water saver, 1 HP to 12.50 HP oil immersed 2 set contactor Complete job including indicators, switches, over load functions, line fault protection, power saving functions as per manufacturer specifications, details & enclosure etc. Complete in all respect including carriage, GST as applicable& installation charges.
C.I Fitting Outside Pump Chamber, Gravel Pit
Providing and installing 100mm dia delivery main (From Tube well to Duck Foot bend including cost of C.I/D.F Pipes, D/F Sluice valves, D/F NRV & Specials as C.I Bends, Tail Piece Tees etc.. inside the pump chamber as per standard design complete in all respects
Construction of Gravel Pit outside the Pump Chamber (0.90m Dia.) as per standard design & drawings of public health department.
M/S Rakesh Kumar Govt. Contractor Dhuri
Goyal Tubewell store
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .