Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.1 LAccepted-AOC NIVADA TIVAYA ROAD TIVYA MUST BUS STOP VILLAGE KHATAULI SAHARANPUR UP 247001 | SAHARANPUR | SAHARANPUR | UP | 247001 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹45.1 L+₹4.0 L (9.61%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Tenderer | |
| 3 | L3₹45.3 L+₹4.2 L (10.2%)Rejected-Finance 13 218 MASJID EXTEN SADAR BAZAR | L3 | Rejected-Finance Not Lowest Tenderer |
Tender Value
₹46.0 L
EMD Value
₹91,900
Closing Date
7 Feb 2023, 6:00 pmClosed
GE South Delhi Cantt-10
GE South Delhi Cantt-10
SPL REPAIR/REPLACEMENT OF WATER PIPELINES, SPL REPAIR TO ROOF TREATMENT OF BLDG NO.N-60 OFFICE COMPLEX AND BLDG NO.P-04 OFFR MD ACCN OF 60 MED REGT AND CERTAIN MINOR WORKS AT DUNDAHERA MIL STN, GURUGRAM UNDER AGE B/R-II AND AGE E/M OF GE (SOUTH) DELH
2023_MES_574201_1
GE/DS-105/2022-23
Open Tender
Civil Works
Item Rate
120 days
GE South Delhi Cantt
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
GE South Delhi Cantt
₹91,900
Yes
3 Mar 2023
10 Jan 2023
9 Feb 2023
10 Jan 2023
7 Feb 2023
24 Jan 2023
Amount
Supply, installation, testing and Commissioning of Centrifugal Pump set horizontal type split casing complete with electric motor of 20 HP, 415 Volts 3 phase, 50 Hz, AC supply, 1450 RPM, Capacity of pump 5 LPS at 34 mtr head including necessary demolition of existing foundation, earthwork and PCC (1:2:4) for foundation with MS Frame work, MS bolts with nuts anti vibration pads as per manufacturer specifications, provision of gauge with central valve and foundation finally foundation treated with two coats of oil bound distemper over a coat of primer complete all as specified and as directed.
S&F fully automatic star delta starter with sheet metal encloser ML-2 with relay range 20-32 Amp suitable for 20 HP centrifugal pump complete all as specified and as directed.
S&F FRLS PVC insulated industrial copper conductor wire 1100 volts grade of size 25 sqmm 3 core complete all as specified and as directed.
S&F MS pipe header as per IS 3589,200 mm dia size min 6mm thick 10 mtr length with flanged ends closed with dead plates not less than 18mm thick fixed with nut bolts and washer and rubber gasket and including provision of following incoming and outgoing connections of MS pipe,Heavy duty,class C, of length 200 mm with flanged with two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed. (a)100 mm dia incoming-02 Nos. (b) 100 mm dia outgoing-04 Nos. (c) Pressure gauge of suitable pressure-02 Nos
Excavation in trenches not exc 1.5 M wide and not exc 1.5 M in depth for pipe line, etc in soft/ loose soil getting out and levelling of bottom surface to required level complete all as specified and as directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 Cm thick soft / loose soil complete all as specified and as directed.
Removing excavated material (Soil) from site to a distance not exc 50 M away and depositing where directed at a level not exc 1.5mtr above the starting point complete all as specified and as directed.
Boring holes under road pavement by bocky manually in any type of soil upto 200 mm bore complete all as specified and as directed.
Supplying, laying, jointing, testing and commmisioning of 100 mm bore DI Pipe as per IS 8329, class K-7 with inside cement mortar lining including rubber gasket joint(Tyton joint) with spigot and socket ends laid in trenches complete all as specified and as directed. Note:- The quoted rates are deemed to be included M&L for providing rubber gasket joint as per site requirement Joints.
M&L for 100mm DI fittings/specials such as Tees, bends (any type, radius and angle) tapers any type, collars, tail pieces, caps and plugs of the following sizes confirming to IS: 9523 complete all as specified and as directed.
Supplying, laying, jointing, testing and commmisioning of 80 mm bore CI Pipe as per IS 8329, class 'A' with inside cement mortar lining including rubber gasket joint(Tyton joint) with spigot and socket ends laid in trenches complete all as specified and as directed. Note:- The quoted rates are deemed to be included M&L for providing rubber gasket joint as per site requirement Joints.
M&L for 80mm CI fittings/specials such as Tees, bends (any type, radius and angle) tapers any type, collars, tail pieces, caps and plugs of the following sizes confirming to IS: 1538-1993 complete all as specified and as directed.
M&L for laying of 50 mm bore GI tubing 'medium grade' in trenches/walls with all accessories including bends, elbow, socket complete all as specified and as directed.
M&L for laying of 40 mm bore GI tubing 'medium grade' in trenches/walls with all accessories including bends, elbow, socket complete all as specified and as directed.
M&L for Run lead joint including jointing material for CI/DI pipe of following size/bore for the following complete all as specified and as directed :-
80 mm bore
100 mm bore
Supplying, laying, jointing, welding & testing 100 mm bore MS Pipe (Heavy duty class 'C') laid in trenches or on floors for connections to centrifugal pump sets for suction, pump to header and to connect out going water main CI/DI pipe line complete all as specified and as directed. Note:- The quoted rate are deemed to be included for MS Flanges and Flange joints with rubber/fiber gasket joint complete with jointing material.
Supply, installation and testing of flanged ends water meter 100 mm bore ISI marked woltman type, Class 'B' of following sizes and making good connection with flanged ends, with gasket rubber sheet and nut & bolts fixing in horizontal/inclind/vertical position, complete all as specified and as directed. Note:- The quoted rate are deemed to be included for MS Flanges and Flange joints with rubber/fiber gasket joint complete with jointing material.
Supply, fixing, jointing & testing Cast Iron Sluice Valve 100 mm size, ISI Marked, flanged ends drilled pressure rating PN-1.0, PD Short body, confirming to IS 14846 -2000, having stainless steel spindle with cast iron operation wheel at top ine complete all as specified and as directed at site by the Engr-in-Charge. Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this itemcomplete all as specified and as directed.
Supply, fixing, jointing and testing of Cast iron Non Return valve of 100 mm size without by pass arrangement, swing type, confirming to IS 5312, flanged ends pressure rating PN 1.0 complete all as specified and as directed. Note:- The quoted rate are deemed to be included for MS Flanges and Flange joints with rubber/fiber gasket joint complete with jointing material.
Supply, fixing, jointing & testing Cast Iron Sluice Valve 80 mm size, ISI Marked, flanged ends drilled pressure rating PN-1.0, PD Short body, confirming to IS 14846 -2000, having stainless steel spindle with cast iron operation wheel at top ine complete all as specified and as directed. Note:- The quoted rate are deemed to be included for MS Flanges and Flange joints with rubber/fiber gasket joint complete with jointing material.
Supply, fixing, jointing & testing Cast Iron Sluice Valve 50 mm size, ISI Marked, flanged ends drilled pressure rating PN-1.0, PD Short body, confirming to IS 14846 -2000, having stainless steel spindle with cast iron operation wheel at top ine complete all as specified and as directed. Note:- The quoted rate are deemed to be included for MS Flanges and Flange joints with rubber/fiber gasket joint complete with jointing material.
M&L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI strip 32x6 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board test point at the other and watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 40 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate, RCC cover etc. complete all as specified and as directed.
S&F in repairs earth continuity conductor or main earthing lead fixed to wall on batten or reccess or chases or burid in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc as required 32X6 mm galvanised iron strip complete all as specified and as directed.
Cutting of vegetable plant (girth not exceeding 300mm) from roof, terrace, chajjas etc digging out the roots and making good the surface in PCC 1:2:4 type B1 with surfaces finished to match complete including scaffolding etc, complete all as specified and as directed. Note : One entire building/block shall be measured and paid as one Block.
Dismantling of brick tiles (laid flat or on edge) on roof surface.laid bedded and pointed in any mortar complete all as specified and as directed.
Demolition of mud in roof, any thickness, including plastering and leeping upto full height of bldg including necessary scaffolding arrangement complete (whether full thickness removed or only a part there of) and removing rubbish from cantonment area or as directed, complete all as specified and as directed.
M&L for cutting out craks to V-section in existing roof or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3, complete all as specified and as directed.
M&L for roof treatment in following stages, complete all as specified and as directed. (i) Preparation of concrete surfaces by wire brush and cleaned top surfaces of cement concrete . (ii) PCC type B-0, 1:2:4 (12.5mm gradded aggregate) to maintain slope with average thickness of 40mm as in roof padding alongwith liquid water proffing compound (FOSROC SBR LATEX). (iii) Applying evenly a tack coat of industrial bitumen 85/25 @ 1.2 Kg per sqm including cleaning surfaces (iv) APP polymeric water proofing membrane minimum 3 mm thick and wieghing not less than 3.0 Kg per Sqm , black finish reinforced with non woven polyester matt with a thermo fasable finish laid over bitumen primer @ 0.5Kg/ Sqm by torching application with a propane or a butrane gas torch with an overlap of 100mm at the sides and 150mm at the ends, as per manufacturers instructiions.
Make of APP: "Moply FP" manufactured by STP Texsa Ltd or Hyper Plas (Polyester) manufactured by M/S IWL Ltd or "Shaliplas"ter) manufactured by M/S Capital Steels and Chemical Pvt Ltd or Makpolyplast manufactured by M/S M K Patro as approved by GE.
Note :- The water proofing treatment shall be got carried out by the manufacturer or their authorised applicators. The contractor shall give 10 years guarantee for effectiveness of water proofing treatment, 2.5% of work done amount of this item shall be retained from contractors payment for a period of 10 years reckoned from date of physical completion of this work, or in lieu contractor may deposit bank FDR for the said amount for 10 years which shall be released by GE on expiry of satisfactory completion of 10 years period.
M&L for cement concrete tiles 20cm x 20cm x 20mm thick, machine pressed, set jointed and pointed in neat cement slurry in floors, and cut and polished laid over 15mm thick screed bed in CM 1:6 complete all as specified and as directed.
M&L for cement concrete type B1 - 1:2:4 (using 20mm graded stone aggregate) in roof kerbs or mud stop rounded or chamfered on edge etc. complete all as specified and as directed.
Taking up or down steel tubing and connections including cleaning for re-fixing, 20 mm bore of pipe, complete all as specified and as directed.
S&F 20 mm bore GI tubes, medium grade galvanised, with all fittings and fixed complete to walls and ceilings or laid floors or concealed, complete all as specified and as directed.
Dismantling water tanks of capacity exceeding 250 litres but not exceeding 500 litres,complete all as specified and as directed.
All as per Srl item No.33 above but exceeding 500 litres but not exceeding 1000 litres, complete all as specified and as directed.
S&F 500 ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position, complete all as specified and as directed.
All as per Srl item No.35 above but exceeding 500 litres but not exceeding 1000 litres complete all as specified and as directed.
S&F ball brass valves, high pressure, with of PTMT with epoxy coated aluminium rod & high desity plastic ball ascrewed for iron pipe of 20mm bore and fixed complete all as specified and as directed.
S&F in repairs gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe 20 mm bore,complete all as specified and as directed.
Taking down cement or cement lime plaster, any description, on brick or stone walls, concrete surface etc including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and as directed.
M&L for rendering 15mm thick in cement mortar 1:4 on on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement, complete all as specified and as directed.
M&L for preparation of newly plasered surfaces of walls and applying two coat of cement based paint,complete all as specified and as directed.
Supply only liquid water proofing compound,complete all as specified and as directed.
Taking down rain water pipe (any size) or pattern incl all fittings, head shoes, bends swan necks etc incl cleaning or re-fixing or removal to store(measured overall as fixed along the centre line over fittings and accessories, complete all as specified and as directed.
S&F PVC (SWR) pipes, 110mm dia single socketed in any length with rubber ring joints fixed to walls, complete all as specified and as directed.
S&F PVC (SWR) bends/ Tee any radius, 110mm bore,complete all as specified and as directed.
S&F holder bat clamps 100mm bore out of 50mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof, complete all as specified and as directed.
Demolition of brick work built in cement mortar or cement lime mortar, complete all as specified and as directed.
M&L brick work with sub class `B' bricks straight or curved on plan exc. 6mtr mean radius built in cement mortor 1:6, complete all as specified and as directed.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out any type of soil complete all as specified and as directed.
M&L for rolling and consolidating formation surface in cutting complete all as specified and as directed.
M&L for hardcore of guage broken stones n.exc 63mm, deposited, spread and levelled in layers n.exc 15 cm thick water and rammed to a true surface complete all as specified and as directed.
M&L 100 mm thick PCC 1:4:8 type D-2 using 40 mm graded crushed stone agg as in sub base complete all as specified and as directed.
M&L for 100mm thick cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone agg) laid in bags as in hard standing/flooring complete all as specified and as directed.
M&L for forming contraction (Dummy) joints 65mm deep x 10 mm wide filled with seraling compound graded 'B' complete all as specified and as directed.
Spike rolling to surfaces or making impressions of expanded metal, whilst the concrete is green complete all as specified and as directed.
Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and as directed.
M&L for point wiring with PVC insulated unsheathed multi stranded FRLS type copper conductor cable of size 1.5 Sqmm 1100 V grade including one run of PVC insulated unsheathed multi stranded FRLS type copper conductor cable of size 1.5 Sqmm as earth continiuty conductor connected to common earth dolly in and incluidng PVC concealed conduit of suitable dia medium grade ISI marked and its accessories including provn of MS new factory made sunken box of suitable size for housing the Modular switch, sockets fan regulators for the following:-
One Exhaust/Ceiling fan point controlled by one number one way 5 Amp switch.
S&F SP 6 Amp piano type flush mounted switch 230/250 Volts grade one way (as catered in point wiring above) complete all as specified and as directed.
S&F of Metal exhaust fan 250 mm size suitable for 240 V, 50 Hz single phase AC supply including nuts, washers, ceiling rose etc complete and necessary electrical connection from ceiling rose to fan connecter with three core sheathed wire of required length complete all as sepcified and as dirercted.
Cutting of walls and making hole for fixing of exhaust fan of suitable size and making good the surface as per existing complete all as specified and as directed.
Note :- The contract sum shall be after deducting the amount of Credit shown in Credit Schedule of this Tender.
M/S.M.S.Devi.Const.Co
verma enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .