| 1 | L1₹41.0 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹42.9 L+₹74,256 (1.76%)Rejected-Finance BHAGAT SINGH CHOWK SURATGARH 335804 DISTT SRIGANGANAGAR RAJ | GANGANAGAR | RAJASTHAN | 335804 | L2 | Rejected-Finance Due to not lowest |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
18 May 2022, 6:00 pmClosed
GE North Bikaner
GE North Bikaner Rajasthan 334001
REPAIR REPLACEMENT OF EXISTING SEWAGE LINE SEPTIC TANK SOAKAGE WELL AND REPAIR TO TOILETS AND REPAIR REPLACEMENT OF CERTAIN B R AND E M WORKS INCL JOINERY AND PERIODICAL SERVICES AND REPAIR TO PATHWAY HARDSTANDING FENCING DRAINAGE IN NORTH CAMP EA
2022_MES_519467_1
GE (N) BKN TOKEN NO 09 /2022-2023
Open Tender
Miscellaneous Works
Item Rate
335 days
Mahajan MFFR
Class D category a i
7 documents required · 7 mandatory
₹500
GE North Bikaner
₹99,000
Yes
9 Jun 2022
22 Apr 2022
23 May 2022
22 Apr 2022
18 May 2022
9 May 2022
Amount
Demolition of brick work built in cement mortar including all quoins, arches pillars complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (unreinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level) complete all as specified and directed by Engineer-in-Charge.
Demolition wall and ceiling boards or insulation boards, any thickness, any description, including cover fillets complete all as specified and directed by Engineer-in-Charge.
Dismantling asbestos cement /MS (corrugated, semi corrugated etc) sheets of any thickness in roof coverings including ridges complete complete all as specified and directed by Engineer-in-Charge.
Taking down shutters of any description exceeding 1 Sqm but not exceeding 2 Sqm each leaf complete all as specified and directed by Engineer-in-Charge.
Taking down chowkats with shutters not exceeding 1.5 Sqm each (without taking off shutters from the frames) etc complete all as specified and directed by Engineer-in-Charge.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exceeding 1.5 Sqm but not exceeding 4 Sqm each complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster of any description, on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
Dismantling posts or struts (RCC or steel) any section , including taking out embedded portion and making good disturbed ground complete all as specified and directed by Engineer-in-Charge.
Dismantling fencing wire , any type complete all as specified and directed by Engineer-in-Charge.
Excavating in post holes (or similar holes) in loose/soft soil each not exceeding 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm ,watering and removing surplus soil to a distance not exceeding 50m and making good surface complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches in soft/loose soil not exceeding 1.5 m wide and not exceeding 1.5 m deep in foundations or for walls of manholes etc not exc 10 sqm on plan and not exceeding 1.5 m in depth and getting out complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, soft/loose soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engineer-in-Charge.
Removing surplus soil obtained from item Nos 11 & 12 here-in-before to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L Brickwork with Fly ash ' bricks straight or curved on plan exc 6 m mean radius built in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
Ditto -all- as per srl item 15 above but except bricks complete all as specified and directed by Engineer-in-Charge.
Dismantling floor, heath or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
M&L for 20 mm thick machine cut Kota stone flooring over cement screed base laid and jointed with grey cement slurrry mixed with pigments to match the shade of the slab including rubbing and Mirror finish polishing complete all as specified and directed by Engineer-in-Charge.
All as per srl item 18 above but kota stone slab 18-20 mm thick in riser of steps, skirting, dados and pillar laid over cement screed and jointed complete all as specified and directed by Engineer-in-Charge.
M&L for coloured non-skid tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and directed by Engineer-in-Charge.
M&L for coloured non-skid tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles etc complete all as specified and directed by Engineer-in-Charge.
S& F Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engineer-in-Charge.
M&L for coloured glazed ceramic tiles of size 350x250 x7mm/450x350x7mm thick as in vertical surface set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tiles etc complete all as specified and directed by Engineer-in-Charge.
M&L 15mm thick screed bed or bedding layer for floor finishes in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
M&L for 10mm thick screed bed or bedding layers for laying of vertical surface of wall in cement mortar 1:4 as on dados skirting and vertical surface complete all as specified and directed by Engineer-in-Charge.
M& L for 75mm thick PCC 1:3:6 type C-1 (Using 20mm gradede crushed stone aggregate) as in plinth protection finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc of Fe-290 (Gde E-165) complete all as specified and directed by Engineer-in-Charge.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge.
S & Fixed in repair Gypsum board of any size for ceiling/walling including all necessary fittings complete all as specified and directed by Engineer-in-Charge.
Supply and fixing anodized snap grid frame work size 605mmx605mm for false ceiling including necessary notching. The snap grid shall consist of aluminium main &cross tee of size 36.5x25x1.40mm weighing 0.24 Kg/RM and 23.5x26.4x1.40mm weighing 0.191 Kg/RM respectively. The main and cross tee shall be jointed at junction crossing with anodized aluminium angle bracket of size 15mmx15mmx1.5mm weighing 0.12 Kg/RM fixed with suitable MS bolts, nuts and washer. The snap grid (main/cross tee section) shall be supported at ends all along the wall with anodized aluminium angle of size 40x25x2mm weighing 0.36 Kg/RM fixed to wall with suitable arrangement and providing 12mm thick mineral fibre board of make armstrong in fixed in grid support with 2.50mm dia plain mild steel wire galvanised class 3 fixed in detached works etc to support snap grid, made of aluminium as per specification complete all as specified and directed by Engineer-in-charge.
Rendering 15mm thick in cement mortar 1: 6 on other than fair faces of brick work or concrete surfaces including finished fair and even surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for Rendering 15mm thick in cement mortar 1: 4 on fair faces of brick work or concrete surfaces including finished fair and even surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for 1.25 mm thick MS Pressed steel frames of size 125mm x 60mm, for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate complete all as specified and directed by Engineer-in-Charge.
M&L for 1.25 mm thick MS Pressed steel frames of size 105mm x 60mm, for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate complete all as specified and directed by Engineer-in-Charge.
S&F steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed by Engineer-in-Charge.
S&F steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified and directed by Engineer-in-Charge.
S & F Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walkways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed by Engineer-in-Charge.
Supply and fixing factory made plain framed panelled shutters (two panel ) 30mm thick 2nd class hardwood with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces . the size of rail and stile as per IS: 1003 ( Part -I) kiln seasoned and chemically pressure treated. complete fixed to chowkats complete all as specified and directed by Engineer-in-Charge.
M&L for Cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in coping or roof kerbs, rounded or chamfered on edges, back filling of frame complete all as specified and directed by Engineer-in-Charge.
S&F 30mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type with sunmica Film on both sides complete all as specified and directed by Engineer-in-Charge.
Supply and fixing( factory Made ) 2nd class hard wood 35 mm thick glazed and skelton shutters open rebated and prepared to receive gauge. (Without sash bars ) edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc sizes of members of shutters as specified in SSR Part-I section 8 clause 8.20 (a) supplied and fitted to chowkats complete all as specified and directed by Engineer-in-Charge.
S&F factory made solid panel PVC door shutter with MS square tube 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails MS frame shall be covered with heat moulded plain colour PVC sheet stirip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top,lock and bottom rail on either side & as gap insert for top rail & bottom rail .panelling of plain colour PVC sheet to be fitted in the MS frame welded /sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement S&F in the steel frame at site as per specification complete all as specified and directed by Engineer-in-Charge.
S&F Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and directed by Engineer-in-Charge.
S&F butt hinges, medium weight, cold rolled mild steel,100mm size complete all as specified and directed by Engineer-in-Charge.
M&L 125mm size aluminium handles, cast type, anodised complete all as specified and directed by Engineer-in-Charge.
S&F 200mm size aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed by Engineer-in-Charge.
S&F Aluminium alloy, anodised, sliding door bolt 250mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed by Engineer-in-Charge.
S&F 150mm long Floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor complete all as specified and directed by Engineer-in-Charge.
S&F 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed by Engineer-in-Charge.
S&F stainless steel wire cloth,0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanisied wire staples complete all as specified and directed by Engineer-in-Charge.
All as per srl item 50 above but fixed in repairs complete all as specified and directed by Engineer-in-Charge.
S&F 3mm thick Sheet glass,ordinary quality and glazing with oil putty in square n exc. 0.5 sqm in each pane complete all as specified and directed by Engineer-in-Charge.
Hacking out old broken glass (any thickness, size, quality or description) from from old wooden or metal frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads etc including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and directed by Engineer-in-Charge.
S& F bib taps cast copper alloy with crutch or butterfly handle, fancy type, CP screwed down, screwed for iron pipe or for brass ferrule 15mm bore, fixed in repairs complete all as specified and directed by Engineer-in-Charge.
S& F Bib taps PTMT with crutch or butterfly handle, fancy type, screwed down, screwed for iron pipe or for brass ferrule 15mm bore, fixed in repairs complete all as specified and directed by Engineer-in-Charge.
M& L for 4mm thick Sheet glass,ordinary quality and glazing with oil putty in square n exc. 0.5 sqm in each pane complete all as specified and directed by Engineer-in-Charge.
Supply and Fixed in repairs fancy type chromium plated stop valves cast copper alloy screwed down high pressure fixed to pipe of 15mm bore complete all as specified and directed by Engineer-in-Charge.
Taking up or down GI steel water tubing and connection including cleaning for refixing of 15mm bore complete all as specified and directed by Engineer-in-Charge.
Taking up or down GI steel water tubing and connection including cleaning for refixing of 20mm bore complete all as specified and directed by Engineer-in-Charge.
Dismantling water tanks exceeding 250 and not exceeding 500 litres capacity and removing to store complete all as specified and directed by Engineer-in-Charge.
Dismantling water tanks exceeding 500 and not exceeding 1000 litres capacity and removing to store complete all as specified and directed by Engineer-in-Charge.
Dismantling water tanks exceeding 1000 and not exceeding 2000 litres capacity and removing to store complete all as specified and directed by Engineer-in-Charge.
M&L for GI tubing 15mm bore with all fittings fixed to walls, ceilings or laid in floors medium grade complete all as specified and directed by Engineer-in-Charge.
Refixing old steel tubing and connections in new or old position (walls,ceiling, floors etc 15mm bore of pipe complete all as specified and directed by Engineer-in-Charge.
M&L for GI tubing 20mm bore with all fittings and fixed complete to walls, ceilings or laid in floors medium grade complete all as specified and directed by Engineer-in-Charge.
Refixing old steel tubing and connections in new or old position(walls,ceiling, floors etc 20mm bore of pipe complete all as specified and directed by Engineer-in-Charge.
S& F Rotational moulded polyethylene triple layed white in colour water storage tanks (cylindrical vertical with closed top) of 500 litres capacity, hoisted and fixed in position including connecting up pipes, fixed in repairs complete all as specified and directed by Engineer-in-Charge.
S& F Rotational moulded polyethylenetriple layed white in colour water storage tanks (cylindrical vertical with closed top) of 1000 litres capacity, hoisted and fixed in position including connecting up pipes, fixed in repairs complete all as specified and directed by Engineer-in-Charge.
S& F Rotational moulded polyethylenetriple layed white in colour water storage tanks (cylindrical vertical with closed top) of 2000 litres capacity, hoisted and fixed in position including connecting up pipes, fixed in repairs complete all as specified and directed by Engineer-in-Charge.
S& F Ball valves, high pressure of PTMT with epoxy coated Aluminium rod and high density plastic ball , screwed for iron pipe or brass ferrule 20mm bore fixed in repairs complete all as specified and directed by Engineer-in-Charge.
S&F Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipe or for unions 15mm bore complete all as specified and directed by Engineer-in-Charge.
S&F Pillar taps, cast copper alloy, with capstan heads, fancy type, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, screwed for iron pipe 15mm bore fixed in repairs complete all as specified and directed by Engineer-in-Charge.
S&F Spray jet with PVC connection to EWC complete all as specified and directed by Engineer-in-Charge.
S&F Vitreous china wash basin, white, flat back, size 550 x 400mm, including brackets and cutting for and pinning in ends of brackets, fixed in repairs including 32mm bore brass chromium plated waste fitting and 32mm bore PVC waste pipe of sufficient length complete all as specified and directed by Engineer-in-Charge.
S & F syphonic action PVC low level flushing cistern of 10 ltr capacity including internal fittings, brackets,32mm flush pipe etc, fixed in repairs complete all as specified and directed by Engineer-in-Charge.
S & F flush kit for syphonic action PVC low level flushing cistern of 10 ltr capacity fixed in repairs complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Vitreous China wash down water closet pan, pedestal pattern, coloured, fixed in repairs including PVC seat cover black/white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device and fixing bolts and making connections to flushing cistern complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Vitreous China WC seat Orrisa pattern size 580 x 440mm, white with integral foot rests fixed in repairs including cast iron ‘P’ or ‘S’ trap, lime concrete in sunken floor making connection with flush pipe using new GI flush bend (Floor portion) and making good to floors, matching to existing surfaces complete all as specified and directed by Engineer-in-Charge.
S& F PVC connection 450 mm long for 15mm dia pipe having CP brass nuts with washers on both ends, fixed in repairs complete all as specified and directed by Engineer-in-Charge.
S&F in repaire Plastic water closet seat cover, black/white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed by Engineer-in-Charge.
S& F Tubular towel rail of brass chromium plated, 20mm dia, D type, 60cm long between flanges fixed in repairs complete all as specified and directed by Engineer-in-Charge.
M&L preparation of new or previously untreated surfaces of steel of any description over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of a red oxide primer complete all as specified and directed by Engineer-in-Charge.
Supply & fixing Flush pipe of polyethylene for PVC, 32 mm dia for low level cistern in repairing to EWC or IWC including all necessary work reqd at site complete all as specified and directed by Engineer-in-Charge.
S&F in repairs PVC (SWR) pipes, 110mm dia, single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed by Engineer-in-Charge.
S&F PVC (SWR) bends any radius 110mm dia complete all as specified and directed by Engineer-in-Charge.
S&F in repairs PVC (SWR) bends any radius, 75 mm bore complete all as specified and directed by Engineer-in-Charge.
S&F in repairs PVC (SWR) junction single, (single T) equal or unequal any radius, 110 mm bore complete all as specified and directed by Engineer-in-Charge.
S&F in repairs PVC (SWR) junction single, (single T) equal or unequal any radius, 75 mm bore complete all as specified and directed by Engineer-in-Charge.
S&F PVC (SWR) branch piece 110mm bore, single (single Y) equal or unequal complete all as specified and directed by Engineer-in-Charge.
S&F in repairs PVC (SWR) reducers 75-110 mm dia complete all as specified and directed by Engineer-in-Charge.
S&F PVC (SWR) vent cowl 75mm bore complete all as specified and directed by Engineer-in-Charge.
S&F in repais PVC (SWR) pipes 75mm dia single socketed in any length with rubber ring joints fixed to walls with clamps etc complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Stack clamps out of 50mm x 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof, for 100 mm bore pipes complete all as specified and directed by Engineer-in-Charge.
S&F Harrison rail mild steel chromium plated with fixing bracket stops rollers complete all as specified and directed by Engineer-in-Charge.
S&F Anodised aluminium door shutters, aluminium section, partition weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc complete all as specified and directed by Engineer-in-Charge.
S&F Anodised aluminium frame for doors, windows, ventilators , partition etc with one or more rebates including joining cleat for fixing complete all as specified and directed by Engineer-in-Charge.
S&F Vitreous China urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe complete all as specified and directed by Engineer-in-Charge.
S& F Toilet paper holder of Stainless steel fixed to walls with chromium plated (CP) brass screws complete all as specified and directed by Engineer-in-Charge.
S& F CP soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and directed by Engineer-in-Charge.
S& F Chromium plated shower roses with or without swivel joints, any size 100 mm sqr, including fixing to steel pipe or union complete all as specified and directed by Engineer-in-Charge.
S& F Door closer hydraulically regulated, designation No. 1 universal type, suitable for door shutters up to 700 mm in width and of weight not more than 80 kg complete all as specified and directed by Engineer-in-Charge.
S& F Mortice lock, vertical type, 4 lever size 100 mm complete all as specified and directed by Engineer-in-Charge.
S&F 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed by Engineer-in-Charge.
M&L Preparing old decorated surface plastered or unplastered by brooming down etc. and applying one coat of white wash on walls including cornices pilasters complete all as specified and directed by Engineer-in-Charge.
M&L Preparing old decorated surface plastered or unplastered by brooming down etc. and applying one coat of white wash on ceiling complete all as specified and directed by Engineer-in-Charge.
M&L Preparing old decorated surface plastered or unplastered by brooming down etc. and applying one coat of distemper oil emulsion on ceiling complete all as specified and directed by Engineer-in-Charge.
M&L Preparing old decorated surface plastered or unplastered by brooming down etc. and applying one coat of colour wash on walls complete all as specified and directed by Engineer-in-Charge.
M&L Preparing old distempered surface of walls including cornices pilasters etc and applying one coat of distemper oil emulsion white or tinted complete all as specified and directed by Engineer-in-Charge.
M&L Preparation of old painted surface of wood or wood based material over 10 cm width or girth of any description & applying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
M&L Preparation of old painted steel surface over 10 cm width or girth of any description & applying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
M&L Preparing old decorated surface of walls including cornices pilasters etc and applying one coat of cement base paint white or tinted as complete all as specified and directed by Engineer-in-Charge.
Complete removal of existing tratment of wall including cornices, pillasters etc by scraping down with electric sanding machine and applying white wall care putty for filling the undulation of wall and finished with two coats distemper oil emulsion, white or tinted complete all as specified and as directed by Engineer-in-Charge
Complete removal of existing tratment of wall including cornices, pillasters etc by electric sanding machine and applying white wall care putty for filling the undulation of wall and finished with two coats of cement based paint, upto 25ft height of bldg above ground level white or tinted complete all as specified and as directed by Engineer-in-Charge
Complete removal of existing tratment of wall including cornices, pillasters etc by electric sanding machine and applying white wall care putty for filling the undulation of wall and finished with two coats of cement based paint, for height above 25ft and below 55ft white or tinted complete all as specified and as directed by Engineer-in-Charge
Complete removal of existing tratment of wall using electric sanding machine including cornices, pillasters etc by scraping down and applying white wall care putty for filling the undulation of wall and finished with two coats of cement based paint,in camouflage pattern in any shape and colour upto 55ft height of bldg above ground level complete all as specified and as directed by Engineer-in-Charge
M&L for providing and applying plaster of paris putty if 1mm thick over plastered surface to prepare the surface even and smooth complete all as specified and directed by Engineer-in-Charge.
M&L for Preparing new plastered or unplastered surfaces of walls and applying two coats of distemper oil emulsion, white or tinted over a coat of primer complete all as specified and directed by Engineer-in-Charge.
M&L preperation of new plastered surface and applying two coat of cement base paint of approved tint, colour on wall including cornices, pilastes complete all as specified and directed by Engineer-in-Charge.
M&L Preparation of old painted plastered or concrete surface over 10 cm girth or width, & applying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
Writing letters or figures (Block.Roman, Italic or Indian) n exc. 30 cm high complete all as specified and directed by Engineer-in-Charge.
M&L for Stops, commas, short lines, dashes, hyphens, brackets, complete all as specified and directed by Engineer-in-Charge.
M&L for Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundations, filling and mass concrete including sub base of floors complete all as specified and directed by Engineer-in-Charge.
M&L for Mild steel work for posts & struts in fencing including cutting top to shape as directed, drilling holes, notching for wire, etc; flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting complete all as specified and directed by Engineer-in-Charge.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc including provision of binding wire complete all as specified and directed by Engineer-in-Charge.
Supply only chain link mild steel galvanized fencing, any type or size complete all as specified and directed by Engineer-in-Charge.
S&F Mild steel bars 10mm dia & over, cut to length, bent to shape requred, including cranking, bending spirally for hooping for columns, hooking ends and binding with and inc mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge.
S&F Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm to 80mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, complete all as specified and directed by Engineer-in-Charge.
S& F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed by Engineer-in-Charge.
M&L for 75 mm thick pcc (1:4:8) type D -2 using 40 mm graded stone agg as in sub base laid in altennate bays finished even and rough complete all as specified and directed by Engineer-in-Charge.
M&L for Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-20 Grade using grey cement and pigment complete all as specified and directed by Engineer-in-Charge.
M&L for Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-20 Grade using grey cement and pigment complete all as specified and directed by Engineer-in-Charge.
M & L Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors complete all as specified and directed by Engineer-in-Charge.
S & F 38 mm Plastic dividing strips, 1.5mm thick complete all as specified and directed by Engineer-in-Charge.
M&L for Bricks, sub class B, laid flat, Bedded and Add if, dry and jointed in jointed mortar pointed in and pointed are 1:3 cement in cement used in floors, old size brick complete all as specified and directed by Engineer-in-Charge.
M&L for 25mm thick sand cushoning under inter locking tiles including spreading and levelling complete all as specified and directed by Engineer-in-Charge.
M&L for 75mm thick Cement concrete 1:2:4 type B-2 using 40mm graded stone aggregate in ]\ floors and paving, laid in panels and finished even & smoth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for 40 mm thick PCC (1:2:4) type B-1 using 20mm graded stone aggregate in ]\ floors and paving, laid in panels and finished even & smoth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for Cement concrete 1:2:4 type B-2 using 40mm graded stone aggregate in surface channels and drains complete all as specified and directed by Engineer-in-Charge.
M&L for pre cast RCC jali 35mm thick in PCC (1:2:4) type B0 using 12.5mm graded stone aggregate set and jointed in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
Supply only liquid water proofing compound complete all as specified and directed by Engineer-in-Charge.
Cleaning/removing blockage of sewer line (SGSW/RCC/CI) of dia 100/150/200/300mm etc of any description or in any position by roding, by pressure pump of any type or by using any mechanical equipments, manually or by puncher of sewage`line and repair the same if required including taking off and refixing manhole covers including removing all sludge in or outside MOD land complete all as specified and directed by Engr-in-Charge.
De-watering from septic tanks/soakage wells by suitable pumps and also removing of all wastes, semi solid or liquid of any description to the location as specified and directed by Engr-in Charge. (note: dewatering tank will be taken to the STP location shown by Engr-inCharge.)
Cleaning/removing blockage of EWC, IWC, Gully Trap, including P or S Traps of any description, by rodding, by pressure pumps of any description or by other mechanical equipments in any position or locations at Military stn MFFR and nodes under AGE MFFR area till complete satisfaction within 48 hr of complaint of Engr-in-Charge.
Cleaning/removing blockage of floor trap, nahni trap, wash basins, sinks etc including waste pipe or waist coupling etc. by manually or mechanically at locations at Military stn MFFR and nodes under AGE MFFR area till complete satisfaction within 48 hr of complaint of Engr-in-Charge.
De-sludging by removing of semi solid sludge from existing septic tanks of any depth, any capacity in foul condition, including taking and placing in position the manhole cover of any description, removal of sludge & solid content to any place outside defence land and deposting where directed by Engineer-in-Charge.
De-sludging the existing / cleaning of man holes of depth not exceeding 2 mtrs of any size by removing silt/grit/sludge and faul water either by mannual or by mechanical means and flushing water through man holes to ensure free flow of sewage, placing back the man holes covers in position including removal all the sludge/silt/any foreign material from the sewer lines out the defence land complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete hunching without bedding layer to drain pipes including drain pipes etc complete against the side of the pipe &removing all retrieved material all as directed by Engr-in-Charge.
M&L for Cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregate as in packing under and hunching against the sides of pipes, without bedding layer, after they are laid and tested in 150 mm dia of pipe complete all as specified and directed by Engineer-in-Charge.
Salt glazed stone were drain pipes, grade ‘A’ 150 mm bore (internal dia) laid in trenches over existing concrete bedding and jointed as specified
Demoliton of stone slab as in roofs , suspended floors any thickness jointed in any mortar complete all as specified and as directed by Engineer-in-Charge.
M&L Jodhpur stone of roof slab self faced ,7.5cm to 10 cm thick ,25 cm to 35cm wide ,hoisted and set ,jointed and grouted in cement and sand mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
M&L for 50mm thick P.C.C 1:3:6 C2 using 40 mm graded stone agg. As in floors over stone patti roof slab finished the surface even and fair complete all as specified and as directed by Engineer-in-Charge.
Cutting into existing manholes or connecting new, drains making good existing benching or forming channel and reforming benching with cement and sand mortar 1:4 or PCC 1:2:4 type B-1 smooth finished and reforming benching as in 150 mm dia of pipe complete all as specified and as directed by Engineer-in-Charge
M&L for Pre cast reinforced cement concrete 1: 2 :4 using 20 mm graded stone aggregates as in manhole covers including removing old damaged cover from manhole complete all as specified and as directed by Engineer-in-Charge
M&L for Mild steel TMT bars 10mm dia and over as reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed by Engineer-in-Charge.
M/S Shree Ram Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .