| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.9 LAccepted-AOC JAISALMER | L1 | Accepted-AOC Accept | |
| 2 | L2₹33.2 L+₹5.7 L (20.9%)Rejected-Finance | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹34.8 L+₹7.4 L (26.8%)Rejected-Finance GANDHI CHOWK MANIPURA JAISALMER RAJ 345001 | JAISALMER | JAISALMER | RAJASTHAN | 345001 | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹35.7 L+₹8.2 L (30.0%)Rejected-Finance | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹35.9 L+₹8.4 L (30.7%)Rejected-Finance JAISALMER | BARMER | RAJASTHAN | 344001 | L5 | Rejected-Finance Not being lowest |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
31 May 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Army Jaisalmer
GE Army Jaisalmer - 345001
REPAIR AND CLEANING OF SEWAGE LINE, SEPTIC TANK AND SOAKAGE WELL IN TECHNICAL AREA AT MIL STN JAISALMER
2023_MES_593091_1
8282/23-24/E8
Open Tender
Civil Works
Item Rate
270 days
Jaisalmer
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Army Jaisalmer
₹98,000
Yes
7 Jul 2023
4 May 2023
7 Jun 2023
4 May 2023
31 May 2023
17 May 2023
Amount
Cleaning of septic tank, man holes and inspection chamber etc. by means of removing the silt, sludge, excreta etc. or other materials, manually or mechanically and depositing the same, where directed at a distance not exceeding 150m including excavation of pits of required size to accommodate the foul materials taken out from septic tank, manholes, soakage pits and covering of the same with soil, not less than 30cm thick layer and making good all excavated site as required and as directed by Engineer-in-Charge. Note for item No. 1.00 :- (i) Depth of silt, sludge, excreta, etc shall only be measured and paid. (ii) Dewatering/pumping out of foul water shall be measured and paid separately.
Pumping out foul water from soakage wells/septic tank mechanically and removing sludge of capacity 10 users complete all as directed by Engineer-in-charge.
---- ditto --- all as per item No. 2.00 above but 20 users
---- ditto --- all as per item No. 2.00 above but 50 users
---- ditto --- all as per item No. 2.00 above but 100 users
---- ditto --- all as per item No. 2.00 above but 250 users
Pumping out of water / liquid from soak wells of any capacity or size and discharge the same to nallah / drains through hose pipe or by other means upto distance of 250 mtr. Including removing old brick bats/Slucisy material from the soak well and refilling the same after washing brick bats with water etc complete in all respect complete all as specified and directed by Engineer-in-charge.
Cleaning the Blockage of floor trap, gully trap , WC/EWC, WHB/Urinal in any size by means of removing the silt, sludge, etc & bailing out water complete manually or mechanically and removing the same out side MD land complete and making good complete all as specified and directed by Engineer-in-charge.
Cleaning of choked sewage line of 150-250 mm bore of pipe including drains by rodding and well flushing with water, taking out waste materials any quantity and depositing where directed including covering the same with at least 30cm thick layer of soil complete all as specified and directed by Engineer-in-charge.
Cleaning of choked sewage line of 250mm-300mm bore of pipe including drains by rodding and well flushing with water, taking out waste materials any quantity and depositing where directed including covering the same with at least 30cm thick layer of soil complete all as specified and directed by Engineer-in-charge.
Cleaning of manholes not exceeding 1.5m deep by means of removing the silt, sludge, etc & bailing out foul water complete manually or mechanically and covering of the same with soil, not less than 30cm thick layer and making good all excavated site as required complete all as specified and directed by Engineer-in-charge.
Dismantling of cast iron or reinforced concrete drain pipes 100 mm dia jointed in cement mortar
Dismantling of cast iron or reinforced concrete drain pipes 75 mm dia jointed in cement mortar
S&F, 100mm bore (sand cast pipe) soil, waste and vent pipes in any length with or without ears and jointing with cement & fixed to walls with MS clamp complete all as specified & directed by Engineer-in-charge.
S&F, 75mm bore (sand cast pipe) soil, waste and vent pipes in any length with or without ears and jointing with cement & fixed to walls with MS clamp complete all as specified & directed by Engineer-in-charge.
S&F in repair, 75mm bore PVC (SWR) single socketed in any length with rubber ring joints & fixed to walls with MS clamp all as specified and directed by Engineer-in-charge.
S&F in repair, 110mm bore PVC (SWR) single socketed in any length with rubber ring joints & fixed to walls with MS clamp complete all as specified and directed by Engineer-in-charge.
S&F in repair, 150mm bore PVC (SWR) single socketed in any length with rubber ring joints & fixed to walls with MS clamp complete all as specified and directed by Engineer-in-charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed by the Engineer-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/disintegrated rock complete all as specified and directed by the Engineer-in-Charge.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil all as specified & directed by Engineer-in-Charge.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in soft/disintigrated rock all as specified & directed by Engineer-in-Charge.
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as directed.
Removing excavated soft/ disintegrated rock to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by the Engineer-in-Charge.
Demolition and breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) of 150 mm bore set in cement mortar including demolition of packing under and hauching against sides of pipes complete all as directed by Engineer-in-charge. (Note :- Excavation and earth work shall be measured and paid separately.
Demolition and breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) of 200 mm bore set in cement mortar including demolition of packing under and hauching against sides of pipes complete all as directed by Engineer-in-charge. (Note :- Excavation and earth work shall be measured and paid separately.
Demolition and breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) of 300mm bore set in cement mortar including demolition of packing under and hauching against sides of pipes complete all as directed by Engineer-in-charge. (Note :- Excavation and earth work shall be measured and paid separately.
M&L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate for concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested complete for 150mm bore pipe all as specified & directed by Engineer-in-charge.
M&L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate for concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested complete for 200mm bore pipe all as specified & directed by Engineer-in-charge.
M&L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate for concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested complete for 300mm bore pipe complete all as specified & directed by Engineer-in-charge.
M&L for 150mm bore reinforced concrete pipes, class NP-2 (ISI marked) with collars, laid in trenches and jointed complete all as specified & directed by Engineer-in-charge.
M&L for 200mm bore reinforced concrete pipes, class NP-2 (ISI marked) with collars, laid in trenches and jointed complete all as specified & directed by Engineer-in-charge.
M&L for 300mm bore reinforced concrete pipes, class NP-2 (ISI marked) with collars, laid in trenches and jointed complete all as specified & directed by Engineer-in-charge.
Demolition of cement concrete in ground floors and pavings n.exc 15cm thickness (below or above ground level) complete all as specified & directed by Engineer-in-charge.
M&L for Cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregate in foundations, filling and mass concrete complete all as specified & directed by Engineer-in-charge.
M&L 75 mm thick Cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) in sub base of flooring/ hard standing complete all as specified & directed by Engineer-in-charge.
M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment laid over and including 25mm thick sand cushioning complete all as specified & directed by Engineer-in-charge. Note :- (i) Pattern of interlocking tile to be rubber moulded or equivalent as approved by GE. (ii) Rate quoted by the contractor shall deemed inclusive of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) packing and finished even and fair to the sides of pavement.
M&L for Providing, precast cement concrete set in cement mortar 1:4 Type C1 1:3:6 (20mm graded aggregate) in window or door cills, lintels, bressummers, steps, quoin blocks (for use with masonry), string courses, copings, kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone walling), corbels, brackets, etc.(of any section indicated), with plain fair faces, including chamfers weatherings, throating etc. and setting in mortar complete with joints to match complete all as specified.
M&L 100 mm thick plain cement concrete (1:2:4) type D-2 (using 40 mm graded stone aggregate) in sub base of flooring/ hard standing complete all as specified & directed by Engineer-in-charge.
Demolition of brickwork or stone/ boulder masonry and built in cement mortar including all quoins arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles and removal unserviceable materials, debris and rubbish to a distance complete all as specified & directed by Engineer-in-charge.
M&L for precast cement concrete (1:3:6) type C-1 using 20mm graded stone aggregate as in block masonry with solid blocks exceeding 10cm width and setting in cement mortar (1:4) complete all as specified & directed by Engineer-in-Charge.
M&L Squared rubble walling Jodhpur type, brought upto courses, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified & directed by Engineer-in-charge.
Extra over stone walling for hammer dressing to face stones with maximum depression on face from a straight edge not exceeding 20mm & dressing face beds and joints as specified to squared rubble walling Jodhpur type brought up to courses complete all as specified & directed by Engineer-in-charge.
Material and labour for flush pointing to squared rubble mansonry, uncoursed or brought upto courses in CM 1:3 complete all as specified and as directed by Engr-in-charge.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.complete all as specified and directed
M&L for rendering 15 mm thick on stone masonry surfaces or surface other than fair face of brick-work or on one side of lathing in cement mortar 1:4 & finished the surface even & fair without using extra cement all as specified.
M & L for Preparing new surfaces plastered or unplastered of wall and apply two coats of cement base paint over a coat of alkali resistance primer on wall complete all as specified and as directed by Engr-in-charge.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. loaded bedded and pointed in any mortar
M&L sand stone slabs 50mm thick in sun-shades, chajjas, shelves, cills, landings, cover stones, templates, etc. n exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in lime mortar 1:2 or cement mortar 1:4. complete
M&L for Jodhpur stone roof slabs, self faced 7.5cm to 10cm thick, 25cm to 35cm wide, hoisted and set, jointed and grouted in lime mortar 1:3 or cement mortar 1:6 complete
demolition of Stone sett paving of any description or thickness etc. all as directed by Engineer-in-charge.
M&L 100 mm thick Cement concrete type D 2, 1:4:8 (using 40 mm graded stone aggregate) in sub base of flooring/ hard standing.
M&L for Stone sett flooring with stone setts of size 200 to 250mm long, 150 to 200mm wide and 150mm deep and sides dressed; bedded in cement mortar 1:3, joints 20mm thick; grouted in cement mortar 1:2 with an admixture of metallic floor hardner 5% by weight of cement and struck flush complete all as directed by Engineer-in-charge.
NOTE :- Contractor to ensure that sewage complaints of any nature will be rectified within 12 hrs after receipt of complaint from the department. However, any delay in rectification of sewage complaint (any type) post 12 hrs will leads to penalty on contractor and will be charged/deducted from the contractor @ Rs 300/- per hour.
BHARAT CONSTRUCTION AND SERVICES
BHAGWATI CONSTRUCTION
AMBEY MAA CONSTRUCTION COMPANY
M/s Shri Inder Construction Company
M/S VISHNOI ENTERPRISES
M/S SHRI HARI CONSTRUCTION COMPANY
Leelashah Enterprises
S K TRADER
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .