| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.9 LAccepted-Finance MANKATTA ROAD MILAN NAGAR DIBRUGARH ASSAM 786003 | DIBRUGARH | ASSAM | 786003 | L1 | Accepted-Finance L1 | |
| 2 | L2₹44.5 L+₹8.5 L (23.7%)Rejected-Finance C 709 VARDHAMAN APARTMENT MAYUR VIHAR I DELHI 110091 INDIA | EAST | DELHI | 110091 | L2 | Rejected-Finance L2 | |
| 3 | L3₹49.1 L+₹13.2 L (36.7%)Rejected-Finance B 814 8TH FLOOR B G TOWER OPP DELHI GATE SHAHIBAUG ROAD AHMEDABAD 380004 | AHMADABAD | GUJARAT | 380004 | L3 | Rejected-Finance L3 | |
| 4 | L4₹53.7 L+₹17.8 L (49.4%)Rejected-Finance 107 265 BRAHAMA NAGAR KANPUR UP 208012 | KANPUR NAGAR | UTTAR PRADESH | 208012 | L4 | Rejected-Finance L4 | |
| 5 | Rejected-Technical 0 0 0 KUMHARAR PATNA BIHAR 800026 | PATNA | BIHAR | 800026 | - | Rejected-Technical Not Eligible for opening of Env-II |
Tender Value
₹50.7 L
EMD Value
₹1.0 L
Closing Date
25 Mar 2023, 6:00 pmClosed
Asstt. General Manager (E-E)
Asstt. General Manager (E-E) O/o Airport Director, Dibrugarh Airport
Supply and laying of cables, SITC of LT panels, FDA system, Air conditioners
2023_AAI_147433_1
AAI/DIB/ENGG(E)/ILS/2022-23
Open Tender
Electrical Works
Item Rate
90 days
O/o Airport Director, Dibrugarh Airport
As per NIT criteria
13 documents required · 13 mandatory
₹1,180
₹1.0 L
23 May 2023
2 Mar 2023
27 Mar 2023
3 Mar 2023
25 Mar 2023
3 Mar 2023
3 Mar 2023 - 8 Mar 2023
Amount
Supply of 1.5TR Hi-wall split AC unit (5-star rating - Inverter type), Copper Condensing unit (Outdoor Unit) including stabilizer and all standard accessories.
ITC of Hi-wall split AC Unit, Copper Condensing unit (Outdoor Unit), Voltage stabilizer, suitable rating SPN MCB, by making required support structure as per site requirement, Gas charging the system with refrigerent, including covering the Copper piping with nitrile rubber insulation with suitable size, PVC pipe Lifting / Shifting of Outdoor & Indoor units upto site location etc., complete as required.
Supply of 4' x 1' wall mounted LED luminarie of 18-25W including all required accessories. Make & Model as directed by Engg-in-Charge.
Installation of 4' x 1' wall mounted LED luminarie including all required accessories etc., complete as required.
Installation of Outdoor LED luminarie including all required accessories. etc. complete as required.
Supply of portable LED Emergency light (rechargeable) of min. 5 watt with all accessories required to hung the light at a required height. Make & Model to be approved by Engg-in-Charge before supply.
Installation of portable LED Emergency light with all accessories required to hung the light at a required height etc., complete as required.
Supply of 1200 mm Sweep, Ceiling fan included required down rod and other standard accessories etc. for operation on 230V, 50 Hz, AC supply, etc. complete as required.
Installation of Ceiling fan including providing two module stepped type electronic fan regulator along with the PVC box and modular plate etc. complete as required.
Supply of 4C x 16 sq.mm size, FRLS, 1.1KV grade, multicore PVC insulated and PVC sheathed armoured Copper conductor cable as per IS standards with upto date amendents as required.
Supply of 3.5C x 120 sq.mm size, 1.1KV grade, multicore XLPE insulated and PVC sheathed Aluminium conductor armoured power cable as per IS 7098:1998 (Part-I) with upto date amendents as required.
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Upto 35sq.mm
Above 95sqmm and upto 185sqmm
Supply and Laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, joining etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
63 mm dia (OD 63mm & ID-51 mm nominal)
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for 3.5 x 120 sq.mm PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required.
Supplying and making end termination with brass compression gland and aluminium lugs for 3.5 x 120 sq.mm PVC/XLPE insulated and PVC sheathed aluminium conductor cable of 1.1 KV grade as required.
Design, Fabrication, Supply, Installtion, Testing and Commissioning of cubicle type, dust and vermin proof, indoor LT panel, IP 42 suitable for 415V ± 10%, 3 phase, 4 wire, 50Hz AC supply system fabricated in compartmentalised modular design as required from CRCA steel of 2mm thick for frame work and covers, 3mm thick for gland plate including supply & Installation of following Switchgears, metering Instrucments and accessories in the LT Panel as per specifications. INCOMER: 63A, DP MCB -1No. OUTGOING: 20A, DP MCB with provision of SPD of T3/40KA - 08 Nos. 10A, DP MCBwith provision of SPD of T3/40KA - 06 Nos. Neutral & Earth Bars.
BUSBARS TPN Aluminium bus bars of minimum capcaity 100A with heat shrinkable coloured sleeves including SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 25KA for 1 sec. OUTGOING 63A, 4P, MCCB - 1 No. with SPD of T2/50KA capacity with backup TPN MCB 63A, 4P, MCCB - 1 No. 40A, TPN, MCB - 1 No. 32A, DP, RCBO (100mA) - 4 No. 20A, DP, MCB - 7 No. 10A, DP, MCB - 6 No. Note: All breakers breaking capacities shall be Icu=Ics. All thermal based release MCCBs shall be comparatmenalised and provided with inbuilt O/L, S/C protection & E/F module with CBCT or Earth fault relay with required CT releases shall be provided. All MCCBs shall be provided with ON, OFF & TRIP indication lamp (LED type) with 2A SP MCB and 1 set Rotary operating mechanism and terminal expansion spreaders .
Supply and fixing of suitable size PVC box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch with indicator, connection etc. as required.
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable PVC box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 Sets of brass nut bolt & spring washer spaced at 50mm)
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 Sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required
Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5 % V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol Bacnet/ Modbus over IP complete as per specifications.
one loop panel
Supply & fixing of Photoelectric, Multi sensor smoke detectors along with mounting base with unique optical sensing chamber, visible LED's complete with all accessories including connections etc. as required. (As per approved makes list)
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.
Supplying & laying of 2 x 1.5 sqmm fire survival armoured cable, 600 / 1000V rated with annealed copper conductor havingh glass mica fire barrier tape covered by extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath as required.
Supply and installation of ABC Fire extinguishers of 6 kg capacity (high quality) as per latest IS standards including the supporting stand and accessories etc. complete as required.
SITC of auto dialer (Voice and SMS) having facitlity of storing voice message & min. 10 contact numbers with all necessary accessories including SIM, 1 year recharge, connections beween fire alarm panel etc, complete as required.
Supply and Installation of Intelligent timer for cyclical operation of 2 AC units at 4-8hrs including required wiring and other accessories etc. comple as required.
REWINDER TECHNO ELECTRICALS
jaydeep agency corporation
Awasthi Electric Works
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .