BDO VP
BDO VP palani panchyat union
Palani Block PKG No 107 AGAMT 2022-23 Library Repairs 3 works
2023_RDTN_278217_1
Palani Block ROC No 2607/2022/B3 AGAMT Library
Open Tender
Civil Works
Works
180 days
Palani block
Palani Block PKG No 107 AGAMT 2022-23 Library Repairs 3 works
5 documents required · 5 mandatory
₹0
₹6,000
Yes
Palani union office
18 Jan 2023
3 Jan 2023
13 Jan 2023
3 Jan 2023
13 Jan 2023
3 Jan 2023
9 Jan 2023
Amount
Repairs of Library building at Chinna kalaiyamputhur H/O Chinna kalaiyamputhur Estimate Amount: Rs.1.95 Lakhs
Removing the existing damged Pressed tiles & weathering course for over roof including cost and conveyance of all materials , labour charges etc., complete.
Clean removal of Cement plaster from walls etc., complete as per Standard Spcification.
Dismantling and damaged flooring Chipping concrete clearing and stacking away from the site including in all other charges etc
Weathering course concrete using best quality of broken jelly of size 20mm uniform gauge in pure slaked lime (no sand to be used) over the RCC Roof slab in the proportion of brick jelly to lime being 32:12:1/2 by volume includingcost and conveyance of all materials to site and all labour charges etc.,complete for 10 m3
Laying one course of Pressed tiles (40% new and 60% old Pressed tiles) including cost and conveyance of all materials , labour charges etc., complete
Plastering with cement mortar 1:3 mix to 10 mm thick including cost and conveyance of all materials & all labour charges etc., complete.
Plastering with cement mortar 1:5 mix to 12 mm thick including cost and conveyance of all materials & all labour charges etc., complete.
Providing the following thickness of Granolithic pattern floor finish with Plain Cement concrete 1 : 2 : 4 mix using 10-12mm ISS HBG metal and the top rubed smooth etc., complete
White washing two coats inclluding cost & conveyance of all materials to site and all labour charges etc., complete.
Supplying and painting the walls with two coats of oil bound distemper over one coat of water based cement primer including cost for distemper, primer, cleaning and scrapping the walls, rendering the walls smooth with necessary putty, brushes, scaffolding arrangements, labour charges, etc., as per standard specification.
Painting two coats with Plastic Emulsion of I st Class Quality paint and of approved colour over a priming coat including through scrapping, clean removal of dirt and cost and conveyance of all materials and labour charges etc,complete.
Painting two coats over Old iron work with quality synthetic enamel paint over existing priming coat including cost and conveyance of all materials and labour charges etc,complete.
Wiring with 2x1.5sqmm (22/0.3) PVC insulated Sc unsheathed Cu conductor of 1100V on wall or ceiling for open PVC light point / fan point SD 17
Wiring with 2x1.5sqmm (22/0.3) PVC insulated Sc unsheathed Cu conductor of 1100V on wall or ceiling for open PVC plug point SD 36
Supply and fixing of single box type 4'40 W flu fitting complete with copper choke and condensor with TW round blocks on wall or ceiling with flu tube with PVC unsheathed copper leads from terminals to the fitting - S.D.No: 88
Labour charges for Repairs doors and window charges
Provision for Ramp with Hand rail arrangements
Provision for Name board charges
GST Amount for providing Service to Government Contract Works for the above Construction Works. { GST Amount is the Total GST Amount for total overall quoted amount above this row in column "BB" for all works in this package}
Part 2 : Renovation of Library building at Kombaipatty H/O Kanakkanpatty Estimate Amount Rs.2.00 lakhs
Dismantling and removing the damage P.C.C concrete portion including all labour charges and all other incidental charges etc., complete.
Supplying and Filling the foundation and basement with filling sand in layers not more than 15cm . Thick well rammed, watered and compacted Complete.
Cement concrete 1:4:8 mix using 40mm ISS HBG metal including cost and conveyance of all matials to site and all labour charges etc., complete
Providing Granolithic pattern floor finish with c.c 1:2:4 mix using 10 to 12mm ISS metal including cost & conveyance of all materials to site and all labour charges etc., complete.
Removing the existing damged Pressed tiles & weathering course for over roof including cost and conveyance of all materials , labour charges etc., complete.
Clean removal of Cement plaster from walls etc., complete as per Standard Spcification.
Weathering course concrete using best quality of broken jelly of size 20mm uniform gauge in pure slaked lime (no sand to be used) over the RCC Roof slab in the proportion of brick jelly to lime being 32:12:1/2 by volume includingcost and conveyance of all materials to site and all labour charges etc.,complete for 10 m3
Laying one course of Pressed tiles (40% new and 60% old Pressed tiles) including cost and conveyance of all materials , labour charges etc., complete
Plastering with cement mortar 1:3 mix to 10 mm thick including cost and conveyance of all materials & all labour charges etc., complete.
Plastering with cement mortar 1:5 mix to 12 mm thick including cost and conveyance of all materials & all labour charges etc., complete.
White washing two coats inclluding cost & conveyance of all materials to site and all labour charges etc., complete.
Supplying and painting the walls with two coats of oil bound distemper over one coat of water based cement primer including cost for distemper, primer, cleaning and scrapping the walls, rendering the walls smooth with necessary putty, brushes, scaffolding arrangements, labour charges, etc., as per standard specification.
Painting two coats with Plastic Emulsion of I st Class Quality paint and of approved colour over a priming coat including through scrapping, clean removal of dirt and cost and conveyance of all materials and labour charges etc,complete.
Painting two coats over Old iron work with quality synthetic enamel paint over existing priming coat including cost and conveyance of all materials and labour charges etc,complete.
Wiring with 2x1.5sqmm (22/0.3) PVC insulated Sc unsheathed Cu conductor of 1100V on wall or ceiling for open PVC light point / fan point SD 17
Wiring with 2x1.5sqmm (22/0.3) PVC insulated Sc unsheathed Cu conductor of 1100V on wall or ceiling for open PVC plug point SD 36
Supply and fixing of single box type 4'40 W flu fitting complete with copper choke and condensor with TW round blocks on wall or ceiling with flu tube with PVC unsheathed copper leads from terminals to the fitting - S.D.No: 88
Supply and Fixing of 1200mm dia sweep AC ceiling fan including cost and conveyance of all materials and labour charges etc complete. SD 107
Labour charges for Repairs doors and window charges
Provision for Ramp with Hand rail arrangements
Provision for Name board charges
GST Amount for providing Service to Government Contract Works for the above Construction Works. { GST Amount is the Total GST Amount for total overall quoted amount above this row in column "BB" for all works in this package}
Renovation of Library building at Pethanaickenpatty H/O Pethanaickenpatty Estimate Amount: Rs.1.80 Lakhs
Removing the existing damged Pressed tiles & weathering course for over roof including cost and conveyance of all materials , labour charges etc., complete.
Clean removal of Cement plaster from walls etc., complete as per Standard Spcification.
Dismantling and damaged flooring Chipping concrete clearing and stacking away from the site including in all other charges etc
Weathering course concrete using best quality of broken jelly of size 20mm uniform gauge in pure slaked lime (no sand to be used) over the RCC Roof slab in the proportion of brick jelly to lime being 32:12:1/2 by volume includingcost and conveyance of all materials to site and all labour charges etc.,complete for 10 m3
Laying one course of Pressed tiles (40% new and 60% old Pressed tiles) including cost and conveyance of all materials , labour charges etc., complete
Plastering with cement mortar 1:3 mix to 10 mm thick including cost and conveyance of all materials & all labour charges etc., complete.
Plastering with cement mortar 1:5 mix to 12 mm thick including cost and conveyance of all materials & all labour charges etc., complete.
Providing the following thickness of Granolithic pattern floor finish with Plain Cement concrete 1 : 2 : 4 mix using 10-12mm ISS HBG metal and the top rubed smooth etc., complete
Supplying and painting the walls with two coats of oil bound distemper over one coat of water based cement primer including cost for distemper, primer, cleaning and scrapping the walls, rendering the walls smooth with necessary putty, brushes, scaffolding arrangements, labour charges, etc., as per standard specification.
Painting two coats with Plastic Emulsion of I st Class Quality paint and of approved colour over a priming coat including through scrapping, clean removal of dirt and cost and conveyance of all materials and labour charges etc,complete.
Painting two coats over Old iron work with quality synthetic enamel paint over existing priming coat including cost and conveyance of all materials and labour charges etc,complete.
Provision for Electrification arrangements
Wiring with 2x1.5sqmm (22/0.3) PVC insulated Sc unsheathed Cu conductor of 1100V on wall or ceiling for open PVC light point / fan point SD 17
Wiring with 2x1.5sqmm (22/0.3) PVC insulated Sc unsheathed Cu conductor of 1100V on wall or ceiling for open PVC plug point SD 36
Supply and fixing of single box type 4'40 W flu fitting complete with copper choke and condensor with TW round blocks on wall or ceiling with flu tube with PVC unsheathed copper leads from terminals to the fitting - S.D.No: 88
Supply and fixing of WT bulk head fitting with guard (Philips / Bajaj / Crompton / K-Lite) suitable for 11W CFL lamp with CFL S.D.No: 83
Supply and Fixing of 1200mm dia sweep AC ceiling fan including cost and conveyance of all materials and labour charges etc complete. SD 107
Supply and run of 4x6sqmm (84/0.3) PVC insulated Sc unsheathed Cu conductor of 1100V for Service connection mains SD 64
Labour charges for Repairs doors and window charges
Provision for Ramp with Hand rail arrangements
Provision for Name board charges
GST Amount for providing Service to Government Contract Works for the above Construction Works. { GST Amount is the Total GST Amount for total overall quoted amount above this row in column "BB" for all works in this package}
N.KARUPPUCHAMY
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .