| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹39.5 LAdmitted-Finance 975 E LOHIYA GALI NO 4 BABARPUR DELHI 110032 | DELHI | SHAHDARA | DELHI | 110032 | L1 | Admitted-Finance | ||
| 2 | L2₹46.4 L+₹6.9 L (17.4%)Admitted-Finance | L2 | Admitted-Finance | ||
| 3 | Not Admitted-Fee/PreQual/Technical 1853 2ND FLOOR BHAGIRATH PALACE SURYA BAZAR CHANDI CHOWK NORTH DELHI DELHI 110006 | NORTH | DELHI | 110006 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | ||
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹77.4 L
EMD Value
₹1.5 L
Closing Date
20 Jan 2026, 3:00 pmClosed
Executive Engineer (Elect.)
EE (E), PWD NES/ M-251, LM Bund Road, Ramesh Park
SH- Running and operation/maintenance of pump set and maintenance of E.I i/c compound light, UPS, CCTV and miscellaneous E.I Work)
2026_PWD_284815_1
81/EE(E)/PWD NES ED/2025-26 (Recall)
Open Tender
Electrical Works
Percentage
365 days
Sub Div-2512
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹1.5 L
Yes
23 Jan 2026
13 Jan 2026
20 Jan 2026
13 Jan 2026
20 Jan 2026
13 Jan 2026
HLTB Jail Block Running operation and routine maintenance of internal EI & light points, fan points, Exhaust Fan point, call bell point, compound light, high mast lights, Pole Light on RCC Road Tahirpur & power point and main distribution board and SDB’s, pump sets and control panel cleaning of all electrical installation at HLTB Complex in Two shift i/e 6:00 AM to 2:00 PM & 2:00 PM to 10:00 PM on all days of week i/c Sunday & holidays. a) 2 Nos. Wireman cum Operator (Two Shift) b) 2 Nos. Khallasi (Two Shift)
Kasturba Gram, Anand Gram & Sewage Pump House Running operation and routine maintenance of internal EI & light points, fan points, Exhaust Fan point, call bell point, flood light, pole lights i/c power point and main distribution board and SDB’s, pump sets and Sewage pump house, control panel cleaning of all electrical installation at Kasturba Gram, Anand Gram & Sewage Pump in General shift i/e 9:00 AM to 5:00 PM on all days of week i/c Sunday & holidays. a) 2 Nos. Wireman cum Operator (9:00 AM to 5:00 PM)
Sanskar Ashram Running operation and routine maintenance of internal EI & light points, fan points, Exhaust Fan point, call bell point, compound light, pole lights, high mast i/c power point and main distribution board and SDB’s, pump sets Sewage & Watering and control panel cleaning of all electrical installation at Sanskar Ashram, in Round the Clock on all days of week i/c Sunday & holidays. a) 3 Nos. Wireman cum Operator (Round the Clock) b) 3 Nos. Khallasi (Round the Clock)
RCL office, TCPC(O), TCPC (L) Sunder Nagari, Civil Sub Division M-2222, Civil Sub Division M-2114, Tahirpur Red Light & M- 2221 Running operation and routine maintenance of internal EI & light points, fan points, Exhaust Fan point, call bell point i/c power point and main distribution board and SDB’s, pump sets and control panel cleaning of all electrical installation at RCL office, TCPC(O), TCPC (L) sunder nagari, Civil Sub Division M-2222, Civil Sub Division M-2114, Tahirpur Red Light in General shift 9:00 AM to 5:00 PM on all days of week excluding Sunday & holidays. a) 1 Nos. Wireman cum Operator (9.00 AM to 5.00PM) b) 1 Nos. Khallasi (9.00 AM to 5.00PM) - 1 Job
Supplying and Fixing of Ventilating Exhaust fan upto 250mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning etc. as required.
Replacement of defective wall fan by Supplying Installation, testing & commissioning of wall fan 400 mm sweep in the existing surface and making good the damage, making connections, interconnections, earthing etc. as required.
Replacement of defective by S.I.T.C. of electric ceiling fans 1200mm sweep shall be capacitor type, with double ball bearing complete with capacitor, 300mm down rods, canopies, three number blades made of aluminum alloy, suitable for operation on single phase, AC 230 volt, 50Hz supply and but without regulator.
Replacement of defective exhaust fan by Supplying and Installation of exhaust fan 375-380mm sweep 900 RPM in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning i/c dismentling the existing etc. as required.
Replacement of defective exhaust fan by Supplying and Installation of exhaust fan 450mm sweep 900 RPM in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning i/c dismentling the existing etc. as required.
S & fixing 3 x 10 sqmm. P.V.C insulated XLPE Al. conducter armoured cable on surface of wall i/c connection testing etc. as required.
S & fixing 4 x 16 sqmm. P.V.C insulated XLPE Al. conducter armoured cable on surface of wall i/c connection testing etc. as required.
S & fixing 4 x 16 sqmm. P.V.C insulated XLPE Al. conducter armoured cable direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. Connection testing etc. as required.
Supplying, installation , testing & commissioning of Weather proof pole box made out of hot molded SMC sheet and following size complete with 4 way 60 amps connector and suitable din bar for S/F one no. amps SP MCB complete with inter connection as required. (a) 250mm x 200mm x 100mm
S & laying of 3 core 2.5 Sq.mm wire in the existing pole i/c connection testing etc. as required.
Servicing of 25Ltr. water heater (Geyser) by chemical and remove the waste powder from tank i/c remove from the site and reinstall testing commissioning etc. as required.
Repairing of 25Ltr. water heater (Geyser) by replacing of following defective parts i/c testing commissioning etc. as required. (a) Thermostat
(b) Element
Supply and replacement of defective Geyser Connection pipe SS body of 3 feet i/c connection testing etc. as required
Servicing/overhauling the desert/room coolers, checking the unit, changing the wood wool pads, distributor of water, elbow, PVC pipe of required length, oiling of Blower motor, fixing missing nuts, bolts, screws etc. providing necessary insulation tape etc. on wore joints, reinstallation of Desert Coolers to its original position, testing, commissioning etc. complete as required.
Replacement of Cooler Pump in the existing Desert Cooler etc. complete as required.
Replacement of burnt out Cooler Motor single phase motor in existing desert coolers i/c testing commissioning etc. as required.
Supplying and fixing of 15 Amp Top plug in the extension board i/c connection testing etc. as required.
Comprehensive Maintenance and minor repairing of CCTV System installed HLTB complex, Tahirpur, Delhi with minimum one visits in a month by Technical Engineer/Qualified Technician and additional visits as and when required at site. The system consists of following items : CCTV Camera -10 Nos. 16 Ch. NVR - 01 Nos. UPS SFP Module Rack POE Switch Patch Panel
Comprehensive Maintenance and minor repairing of Online UPS System installed at HLTB, Sanskar & I.T.I complex, including all accessories replacement excluding Fuse, Battery, Transformer, Resistor by Technical Engineer/Qualified Technician and additional visits as and when required at site. (a) 02 KVA UPS - 03 Nos.
(b) 06 KVA UPS - 04 Nos.
(c) 10 KVA UPS - 01 Nos.
Replacement of defective by Supply & fixing of 26AH 12 Volt SMF Type Battery in the existing online UPS system with connection wire Nut-bolt i/c buy back of old battery etc. complete as required.
Replacement of defective by Supply & fixing of 42AH 12 Volt SMF Type Battery in the existing online UPS system with connection wire Nut-bolt i/c buy back of old battery etc. complete as required.
Lowering of submersible /mono submersible/ centrifugal pump set Upto 20Hp rating along with G.I /MS Pipe from existing bore well/ sump with the help of chain and pulley block i/c cartage from workshop to site etc. as required.
Lifting of submersible /mono submersible/ centrifugal pump set Upto 20Hp rating along with G.I /MS Pipe from existing bore well/ sump with the help of chain and pulley block i/c cartage from workshop to site etc. as required.
Repairing overhauling & Rewinding of up to 5 HP submersible /Monoblock Pump motor set i/c replacement of emplier, replacement of all burnt parts i.e. G.M. Bush, Thrust Plate, Motor Seal 2 nos. O-Ring, 16nos Ss Stand, ss key 1 No. gasket 1set,ballbering 2nos, 6305, etc. i/c reassembling testing, commissioning etc. complete as reqd. i/c Less Credit of dismantle material.
Repairing overhauling & Rewinding upto 10 HP submersible /Monoblock/sewage Pump motor set i/c replacement of emplier, replacement of all burnt parts i.e. G.M. Bush, Thrust Plate, Motor Seal 2 nos. O-Ring, 16nos Ss Stand, ss key 1 No. gasket 1set, ballbering 2nos, 6305, etc. i/c reassembling testing, commissioning etc. complete as reqd. i/c Less Credit of dismantle material.
Repairing overhauling & Rewinding upto 20 HP submersible /Monoblock/sewage Pump motor set i/c replacement of emplier, replacement of all burnt parts i.e. G.M. Bush, Thrust Plate, Motor Seal 2 nos. O-Ring, 16nos Ss Stand, ss key 1 No. gasket 1set,ballbering 2nos, 6305, etc. i/c reassembling testing, commissioning etc. complete as reqd. i/c Less Credit of dismantle material.
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. Group C
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm
6 x 1.5 sq. mm
3 x 4 sq. mm
6 x 4 sq. mm
Supplying and fixing of following sizes of PVC conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. a) 20 mm
Replacement of defective Switch/socket by Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
3 pin 5/6 A socket outlet
15/16 A switch
6 pin 15/16 amp socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Replacement of defective box by Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess i/c dismentling the existing etc. as required 3 Module (100 mmX75 mm)
6 Module (200 mmX75 mm)
12 Module (200 mmX150 mm)
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.
5/6 A switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Replacement of defective by Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way, Double door
8 way, Double door
12 way, Double door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required. (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8 way (4 + 24), Double door
12 way (4 + 36), Double door
Replacement of defective by Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 125 A, 16 kA, TPMCCB
250 A, 25 kA, TPMCCB
Replacement of defective by Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Single pole and neutral
Replacement of defective by Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 Amp.
Replacement of defective by Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A
Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 1.7 centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum ower consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).
Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/ 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 18- 22 watt
Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P.F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg120deg as per the application and the project requirement deg, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).
Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP66,IK-10, CRI >80, under voltage and over voltage protection, EMIEMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin),SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 100 watt
Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required. 1 Run of cable
Supplying Installation Testing and Commissioning of 2MP Fixed Lens IP IR Outdoor Bullet Camera having following specifications and features etc :- 1) Signal System: PAL/NTSC, Signal to Noise Ratio: > 50 dB, Camera should display Camera title, Date & Time in live & recorded video 2)Image Sensor: 1/2.8" or better progressive Scan CMOS to get color image even at night condition(Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better) True Day & Night High Performance Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)- Inbuilt Smart IR LED's with effective distance upto 50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to 1/30000s electronic shutter support, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking.3) Compression (Minimum):-Video:- H.265 or better, H.264H, H.264, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.723 5) Digital Noise Reduction:- DNR (3D) On/Off 6) Video Streaming & Frame Rates :- Triple streaming , configurable(Main stream: 2MP (1920 × 1080)@25/30 fps Sub streams minimum: 720P@25/30 fps). 7) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser, Edge Analytics: Tripwire, Intrusion, Motion Detection 8) Cyber Security: AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, syslog, video trusted boot. 9) Onboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card. 10) Recording Management: Format SD, overwrite, storage management, video to NAS device,
11) Alarm Trigger : Motion/tampering detection; audio detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection 12)Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast, 13) System Capability: ONVIF, Camera shall support open source VMS 14) Ethernet: 1 RJ 45 10/100 Ethernet port 15) Audio : It should support 1 x Built-In Mic and 1/1 Alarm In/ Out for External Mic. and Speakers as per site requirement. 16) Power Input: The camera should support simultaneous dual power input—12 VDC (via power adapter) and PoE (802.3af)—to ensure continuous operation in the event of a failure in one power source. 17) Power Requirement: 12VDC/24 VAC/PoE (802.3af)/ePoE 18) Housing/ Enclosure:- IP67 weather proof, IK10, Metallic body 19) Operating Condition:- Ambient Temperature:- (- )05°C to 50°C, humidity 95% (max) (non-condensing) 20) IR life: 40000 hours or higher 21) Video Bit rate: 32 KBPS - 8 MBPS or better 22) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS (a) 2MP @ 25/30fps@1080P (1920×1080) Outdoor Bullet Camera with 2.8/ 3.6mm fixed lens
Less on account of buy back of dismentle material. Assorted Cooper wire
Assorted LED 2x2 / Batten Fitting
Assorted Celling fan/Exhaust fan
Assorted G.I box, Conduit, MCB, DB, MCCB, Switch Socket, Regulator & XLPE Cable etc.
Assorted Wall fan/Ventilation fan
Assorted Flood Light/Street Light
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 4.07 MB
BOQ_376725.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .