Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance HURA HURA HURA DIST PURULIA W B PIN 723130 | PURULIA | WEST BENGAL | 723130 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical Credentials not O.K |
Tender Value
₹14.8 L
EMD Value
₹29,630
Closing Date
16 Feb 2024, 2:30 pmClosed
DIRECTOR, CSIR-CMERI
The Director, CSIR-CMERI, Durgapur 713209
Civil and Electrical works for establishment of Science Technology and Innovation hub for Sal Butter at Kanska Block, Paschim Bardhaman District in West Bengal.
2024_CSIR_185021_1
60/30/11/23-24/CI/Proj/ESD
Open Tender
Construction Works
Item Rate
60 days
Kanska Block, Paschim Bardhaman District, W.B
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
Yes
DIRECTOR, CSIR-CMERI
₹29,630
Yes
28 Feb 2024
9 Feb 2024
17 Feb 2024
9 Feb 2024
16 Feb 2024
9 Feb 2024
Amount
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Centering & shuttering including strutting, propping etc & removal of form for Foundations, footings, bases of columns, etc. for mass concrete
Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm)
White washing with lime to give an even shade : New work (three or more coats)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying in position 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
Neat cement punning.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
12 mm cement plaster of mix 1:4( 1 cement : 4 coarse sand).
15mm cement plaster on rough side of mix 1:4 (1cement: 4coarse sand)
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing 1 mm thick M.S. sheet sliding-shutters, with frame and diagonal braces of 40x40x6 mm angle iron, 3 mm M.S. gusset plates at the junctions and corners, 25 mm dia pulley, 40x40x6 mm angle and T- iron guide at the top and bottom respectively, including applying a priming coat of approved steel primer
Providing and fixing precoated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm + 0.05 %, total coated thickness with zinc coating 120 gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. Trapizoidal profiled colour coated sheet.
Providing and fixing aluminium work for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) with Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge .(Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade two or more coat.
ELECTRICAL PART
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. : Group C
Wiring for circuit / sub main wiring alongwith earthwire with the following sizes of FRLS PVC insulated, copper conductor, single core cable in surface / recessed medium class PVC conduit as required.
2 x 1.5 sq. mm.+ 1x 1.5 sq. mm earth wire
2 x 2.5 sq. mm.+ 1x 2.5 sq. mm earth wire
2 x 4 sq. mm.+ 1x 4 sq. mm earth wire
4 x 6 sq. mm.+ 2x 6 sq. mm earth wire
4 x 10 sq. mm.+ 2x 6 sq. mm earth wire
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB Distribution board, 240Volts, on surface/ recess, complete with tinned copper busbar, neutral busbar, earth bar, Din bar,interconnection, powder painted including earthing etc. as required.( But without MCB/RCCB/Isolator)
12 way double door
Supplying and fixing 5Amps to 32 Amps rating, 240 /415 volts, 10 KA, "C" curve, miniature circuit breaker suitable for inductive load of following pools in the existing MCB DB complete with connections, testing and comissioning etc. as required.
Single pole
Double pole
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Above 35 sq. mm and upto 95 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Above 35 sq. mm and upto 95 sq. mm ( Clamp with 25x3 mm MS flat clamp)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3.5 X 50 sq. mm (35mm)
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing of flush mounting 6 way (DPX160+18) VTPN IP43-IK09 protection, distribution board with SP/TP MCBs outgoing with provision for FP MCCBs with Speeder link, as incomer with tinned copper busbar 250A for each phase,2 neutral bar, 2 earth bar and cable ties for cable management, fully insulated basbar & shrouded neutral bars, improved pan assembly for each installation, perifitted masking sheet, reversible door for IP 43 DBs, connection, testing, commissioning etc as required. Incomer 100A, DPX3 160 Thermal magnatic FP MCCBs, Icu=25KA- 1No with speeder links. Outgoing -63 A, 415V, C curv - 10KA, TP MCBs - 1 nos, & 32 A, 415V, C curv - 10KA, TP MCBs - 4 nos. and 32 A, 415V, C curv - 10KA, SP MCBs - 3 nos, (Model no- 507746 for VTPN DB, 420055 for 100A, DPX3 160 Thermal magnatic FP MCCBs, Icu=25KA. 408661 for 63A, TP MCB. 408658 for 32A TP MCB and 408595 for 32A SP MCB make- Legrand / eqv.
Supply and Fixing of Extruded aluminium batten available in 4ft run length with multiple lumen packages and suitable for surface, wall & conduit mounting, Clamp, nut bolts and all accessories for fixing wall mounting, connection, testing, commissioning etc as required BN021C LED22S PSU CW GR of Philips or equivalent.)
Supply of 1.1 KV grade XLPE insulated, cores laid up, Thermoplastic tape inner sheathed, armoured and extruded PVC type ST2 outer sheathed Aluminium Conductor armoured power cables conforming to IS 7098 ( Part - 1) 2011 and ISI marked of following sizes, Make- Gloster/ equivalent.
3.5 X 50 sq mm A2XWY/A2XFY cable.
Providing & fixing of four module Sheet steel encloser with 1 no. 40 to 63 Amp, 'C' curv-10 KA, FP MCB and Din Channel for installing it including connection & body earthing complete as required. Model no 507793 for FP enclosure and 408700-02 for FP MCB of Legrand.
Providing & fixing of four module Sheet steel encloser with 1 no. 32 Amp, 'C' curv-10 KA, FP MCB and Din Channel for installing it including connection & body earthing complete as required.Model no 507793 for FP enclosure and 408699 for FP MCB of Legrand..
Supply and fixing of 1200 mm sweep, 230 Volt, 50 Hz, Brown colour, full copper motor and aluminium blades Ceiling mounted fan with suitable suspension down rod, nut-bolt, connection with wire, testing and commissioning etc. as required. (Rapid Air of Orient or equivalent.)
DUTTA CONSTRUCTION
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .