| 1 | L1₹23.0 LAccepted-AOC NEAR INDUSTRIAL ESTATE THANDA PADDAR UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹23.0 L | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹23.6 L+₹56,532 (2.45%)Rejected-AOC 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | ₹23.6 L+₹56,532 (2.45%) | L2 | Rejected-AOC OTHER THAN LOWEST BIDDER |
| 3 | L3₹24.4 L+₹1.4 L (5.92%)Rejected-AOC | ₹24.4 L+₹1.4 L (5.92%) | L3 | Rejected-AOC OTHER THAN LOWEST BIDDER |
| 4 | L4₹25.9 L+₹2.8 L (12.4%)Rejected-AOC NEAR MES FILTER PLANT SANGOOR UDHAMPUR J K 182101 | UDHAMPUR | UDHAMPUR | J K | 182101 | ₹25.9 L+₹2.8 L (12.4%) | L4 | Rejected-AOC OTHER THAN LOWEST BIDDER |
Tender Value
₹35.1 L
EMD Value
₹70,280
Closing Date
1 Apr 2021, 6:00 pmClosed
SHRI A K DUBEY
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182121
REPAIR /MAINT OF HT OH LINES, HT UG CABLE, VCB, HT POLES, HT STAYS, ACSR, EARTHING, LIGHTNING ARRESTOR AND ALLIED WORKS AT JNE AND CHNC AREA UNDER GE (UTILITY) UDHAMPUR
2021_MES_423996_1
CWE/U(U)-102/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
UDHAMPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (UTILITY) UDHAMPUR
₹70,280
Yes
28 Apr 2021
20 Feb 2021
3 Apr 2021
20 Feb 2021
1 Apr 2021
20 Mar 2021
Amount
Dismantling of unserviceable ACSR Conductor of any size from existing over head lines completed all as specified and directed by Engr-in-Charge.
Dismantling of unserviceable steel tubular swaged pole/ PCC pole complete with accessories all as directed by Engr-in-Charge.
BLANK
Dismantling of cross arms of MS fabricated complete with all accessories viz nut, bolts, washer etc. complete all as specified and directed by Engr-in-Charge.
Taking down carefully old unserviceable insulator (any type/size) from existing over head lines complete all as specified and directed by Engr-in-Charge.
Dismantling/Taking down of unserviceable/ damaged air break switch of any capacity & removing from site of works all as specified and directed by Engr-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n.exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for laying cables/pipes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth in hard/dense and getting out soil, complete all as specified and as directed by Engr-in-Charge.
Excavating in trenches, n exc 1.5 m wide and depth exc 1.5 m and n exc 3.0 m, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for laying cables/pipes, etc. n exc 10 sq m on plan and n exc 3.0 m in depth in soft/loose and getting out soil, complete all as specified and as directed by Engr-in-Charge.
Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil,complete all as specified and as directed by Engr-in-Charge.
Removing excavated material not exceeding. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and as directed by Engr-in-Charge.
Dry coarse sand as cushioning to under ground cable provided with layer of 8 cms deep before laying the cable and 15 cms deep after laying and stretching the cable, punned to 18 cm thick complete all as specified and as directed by Engr-in-Charge. NOTE: only punned thickness shall be measured for payment purpose.
Precast unreinforced concrete cable cover class HV, TYPE 2, flat, size 300mmx180mmx40mm conforming to IS-5820 (1970), for protection of HT under ground cable, complete all as specified and as directed by Engr-in-Charge.
Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregates as in foundation, filling and mass concrete, complete all as specified and as directed by Engr-in-Charge.
Plain cement concrete 1:2:4 type B-1(using 20 mm graded stone aggregate) for coping of poles including use of form work complete, all as specified and directed by Engr-in-Charge.
Supply, laying, commissioning and testing in replacement XLPE insulated screended PVC bedded galvanised steel strip or wire armoured electric power (Heay duty) with aluminium condutor 11000 volts (earthed) grade cross sectional area 95 sqmm 3 core cable in trenches, jointing with proper lugs, cable gland including taking down old unsv cable complete all as specified and directed by Engr-in-Charge.
Supply, laying, commissioning and testing in replacement XLPE insulated screended PVC bedded galvanised steel strip or wire armoured electric power (Heay duty) with aluminium condutor 11000 volts (earthed) grade cross sectional area 120 sqmm 3 core cable in trenches, jointing with proper lugs, cable gland including taking down old unsv cable complete all as specified and directed by Engr-in-Charge.
Supply, laying, commissioning and testing in replacement XLPE insulated screended PVC bedded galvanised steel strip or wire armoured electric power (Heay duty) with aluminium condutor 11000 volts (earthed) grade cross sectional area 150 sqmm 3 core cable in trenches, jointing with proper lugs, cable gland including taking down old unsv cable complete all as specified and directed by Engr-in-Charge.
Supply, laying, commissioning and testing in replacement XLPE insulated screended PVC bedded galvanised steel strip or wire armoured electric power (Heay duty) with aluminium condutor 11000 volts (earthed) grade cross sectional area 185 sqmm 3 core cable in trenches, jointing with proper lugs, cable gland including taking down old unsv cable complete all as specified and directed by Engr-in-Charge.
Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 to 120 sqmm complete, all as specified and directed by Engineer-in-Charge.
Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 to 120 sqmm complete, all as specified and directed by Engineer-in-Charge.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 to 95 sqmm complete, all as specified and directed by Engr-in-Charge.
M&L for MS works, cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections ( flat, angle, channel) including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified.
Supply, installation and testing HT gang operated air break switch 11 KV, 3 pole vertically mounted type, mechanically operated, mounted on steel frame with operating mechanism, worked from ground level for current upto 400 Amps with drop out fuse elements of required capacity, GOD/switch having 100 MVA rating at 11 KV and 12 insulators suitable for 11 KV, 50 C/s including mounting on HT poles and necessary electrical connections with two coats of aluminium paint over a coat of red oxide zinc chrome primer complete all as specified and directed by Engr-in-Charge.
Supply and ererction in vertical position Steel tublar swaged poles erected truly vertical or planted as strut complete with 6 mm thick mild steel base plate, welded to pole, B-118 finial taper cap,bolts,nuts & screws, poles made out of ERW MS tubing conforming to IS 2713 Part-II. Type 410-SP-55 (11 m long) including drilling of holes of required size for fixing of cross arms, painting the exposed surfacs of pole with two coats of aluminium paint over a coat of two coats of zinc chrome primer and two coats of black bitumenous paint internally & portion embedded in concrete, making five black & white bands at lower portion of pole each 300 mm wide alternatley, and marking pole No. with black paint at suitable height complete all as specified and directed. Note :- Excavation and earth work, PCC in foundation shall be measured and paid for separetely.
Supply, installation and testing Lightning arresters gapless metal oxide type suitable for 11 KV grade out door Non-linear resist type line discharge class-2 nominal discharge current 65 KA and high current with stand 100 KA assembly suitable for 11 KV including clamps nuts and bolts,washers and connection to 4mm dia GI earth wire including taking down old unsv lightning arrester complete all as specified and directed by Engr-in-Charge.
Supply & fixing 11 KV HT cable route indicator and providing PCC 1:3:6 type C-1 of size 200x200x300 mm (using 20mm graded stone aggregate) to hold the angle Iron (by inserting the split end of angle) up to ground level complete all as specified.
Supply and fixing in replacement of for danger notice plate board of 250 mm x 200mm size of HT 11000 volts system of 1.6 mm thick steel sheet , vitreous enameled white , with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps ,bolts,nuts of approved size for HT 11 KV 25cmx20 cm size complete all as specified.
M&L for tubing 'light grade'' 100mm bore galvanised iron with all fittings and fixed to poles, walls etc. With flat iron clamps/bolts/nuts/washers or laid in floors/under roads, complete all as specified and as directed by Engr-in-Charge.
Supply and fixing of Aluminium Conductor Steel Reinforced any size,stringing properly on insulators and binding with aluminium binding wire, jumpers etc complete all as specified and directed .
Disc type insulator working pressure 11000 volts single disc assembly, porcelain, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green, MS hardware tension clamps, complete all as specified.
Pin Type, Porcelain vitreous, White, brown insulator of size 150 mm height, 150 mm dia for 11000 volts grade including one galvanised mild steel spindle , two galvanised iron washers and one galvanised iron nut in replacement, complete all as specified and directed by Engr-in-Charge.
Taking down old unserviceble and relaying old serviceable XLPE insulated screended PVC bedded galvanised steel strip or wire armoured electric power (Heay duty) with aluminium condutor 11000 volts grade cross sectional area 95 sqmm 3 core cable in trenches, jointing with proper lugs, cable gland obtained against item no.03 all as specified and directed by engineer incharge.
Disconnecting the bindings of loose overhead conductor of HT lines from insulators and stringing the same for proper sag and rebinding with new aluminum binding wires at insulators, making all jumpers and inter connections of conductors at cut points as well as turnings using PG clamps of suitable size as per size of conductor for any type of conductor including stringing of continuous GI earth wire complete all as specified and directed. Note: - (i) Trimming of tree branches upto 3 m all around the conductors is considered to be included in the rates quoted. (ii) Three ACSR conductors and two GI earth wire will be measured as one unit length for payment. (iii) Cost of PG clamps, aluminum winding wire and eye hook for GI earth wire are included in the rates quoted for restringing.
M&L for painting of steel tubular pole 11.0 m long, by applying two coat of aluminium paint after scraping / brushing and cleaning the rust on pole and cross arms. Aluminum painting will be done on pole above 1.5 m height from ground level and balance 1.5 m from ground level will be painted by alternate layer of red and white enameled paint (30 cms each) pole no will be written on pole by black paint in yellow circle of 150 mm dia complete all as specified and directed.
S&F PG clamp die cast aluminum of suitable size of over head line of ACSR conductor connections for PTs CTs isolator connection etc all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to galvanised iron earth strip 32 x 6mm by means of bolts,check nuts and washers and earth strip protected by provision of GI pipe light grade 40mm bore including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 KG/Sqm) and frame of angle iron 25 X 25 X 3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge plate, common salt and charcoal filling, connecting to test point with fixing arrangement, funnel, wire mesh and earth work in any type of soil,returning filling in and removal of surplus soil to a distance not exeeding 50 mtr, all as per electrical plate No 3 of SSR 2009 Part-I all as specified and testing on completion. Note :- Cost of GI earth strip & protection pipe upto 7.5 mtr is deemed to be included in unit rate.
Srl item No36 Contd … (e) 15 mm nominal bore light grade GI protection pipe 7.5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note : On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.
Earthing complete with copper earth plate electrode 60cmx60cmx3.15 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to copper earth strip 32 x 6mm by means of bolts,check nuts and washers and earth strip protected by provision of GI pipe light grade 40mm bore including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 KG/Sqm) and frame of angle iron 25 X 25 X 3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge plate, common salt and charcoal filling, connecting to test point with fixing arrangement, funnel, wire mesh and earth work in any type of soil,returning filling in and removal of surplus soil to a distance not exeeding 50 mtr, all as per electrical plate No 3 of SSR 2009 Part-I all as specified and testing on completion. Note :- Cost of GI earth strip & protection pipe upto 7.5 mtr is deemed to be included in unit rate.
Srl item No 38 Contd … (e) 15 mm nominal bore light grade GI protection pipe 7.5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note : On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.
Copper strip 32 x 6 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and as direceted by Engr-in-Charge.
Disconnecting, opening of VCB of any description and rating 11 KV 1250 Amps capacity for servicing overhauling, taking out and removing unserviceable defective parts including cleaning & servicing greasing, oiling of the parts etc. and replacement of unserviceable parts with new one, reassembling the VCB after overhauling / servicing and its testing complete all a specified and directed. Note: (i) Replacement of unserviceable parts shall be measured and paid for separately under appropriate item of Sch 'A' as supply only but fixing charges of the parts replaced / repaired is considered to be included in these item. (ii) Servicing shall be got carried out by the authorized rep of the VCB manufacturer and the service engineer will submit a service report for each VCB. (iii) Any item not included in CA and required for successful operation of the panel will be provided by the contractor & same shall be considered to be included rate quoted.
Supply only Vacuum Interrupter type suitable for 11 KV VCB Panel complete all as specified and directed.
Supply only Isolating contact assembly 1250 Amps suitable for 11 KV VCB Panel complete, all as specified and directed by Engr-in-Charge.
Supply only Tripping Coil assembly 30 Volts DC suitable for 11 KV VCB Panel complete, all as specified and directed by Engr-in-Charge.
Supply only Close Coil assembly 30 Volts DC suitable for 11 KV VCB Panel , all as specified and directed by Engr-in-Charge.
Supply only Motor & Gear assembly 110V AC and 220 AC for 11 KV VCB Panel complete, all as specified and directed by Engr-in-Charge.
Supply onlyTNC switch for 11 KV VCB Panel complete, all as specified and directed by Engr-in-Charge.
Supply only indication lamp LED type suitable for 230 Volts AC 50Hz and 110/30 Volts DC complete, all as specified and directed by Engr-in-Charge.
M&L for testing and calibration of 11KV VCBs indoor type along with control panel and control wiring, protection system and relays system (relay to tripping coil auxiliary switch male and female housing cut outs etc.) checking of quality of vacuum interrupter, insulation resistance, static contact resistance, testing (IR value, Ratio test, polarity test) and connection verification of 11 KV current transformer set of three) by PRIMARY INJECTION KIT and testing and calibration of relay (set of two over current and one earth fault) by SECONDARY INJECTION KIT including all Other functional tests of the VCB C&R panel and CTs, PTs, complete, all as specified and directed by Engr-in-Charge.
Supply, Installation,Testing and Commisioning of Micro processor base relay (02 O/ C + 01 EF) for 11 KV VCB panel, rating 5 Amps, Auxiliary supply 20-110 Volt DC complete all as specified and directed. Note: (i) Necessary addition / alteration to existing VCB front panel such as cutting / welding of front size of panel board / position if required including necessary modification of wiring shall be carried out at site by the contractor without any extra cost. (ii) The digital relay shall have following protections :- (a) Phase over current protection (b) earth fault protection (c) over voltage (d) Breaker failure indication (e) Auxiliary power supply 24-110 V DC
Disconnecting and taking down unserviceable current transformer of any description and in any position and supply, installation, commissioning and testing of cast resin type 11KV current transformer having ratio 100 + 50 / 5-5A as per IS: 2705 having protection core class 5P10, burden of 15VA and metering core class CL1.0 and burden of 15VA, breaking capacity of 13.1 KV for 1.0 second all as specified and directed.
S&F MS angle as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as direceted by Engr-in-Charge.
Supply only chain link mild steel galvanized fencing with 100 mm square mesh of size of wire 3.15 mm/ 4 mm complete all as specified and as directed by Engr-in-Charge.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wirecomplete all as specified and as directed by Engr-in-Charge.
200 mm long mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and as directed by Engr-in-Charge.
Mild steel cold rolled butt hinges medium weight 125 mm log fixed to pressed steel door /angle iron frame by welding, if required complete all as specified.
Mild Steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing, conforming to Fe 410-W (Gde-E- 250) quality-A, complete all as specified and as directed by Engr-in-Charge.
Brick work with old size sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6, complete all as specified and as directed by Engr-in-Charge.
15mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:6, finish surfaces even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Preparing plastered or unplastered new surfaces of wall and applying three coats of white wash, complete all as specified and as directed by Engr-in-Charge.
Preparation of new steel and iron surfaces exceeding 10cm width or girth and applying two coats of aluminiuml paint over and including one coat of red oxide/zink chrome primer, complete all as specified and as directed by Engr-in-Charge.
M&L for filling crushed/broken aggregates of gauge exceeding 40 mm but not exceeding 80mm in layer thickness 150mm laid in sub station yard complete all as specified and as directed by Engr-in-Charge.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in Soft/loose Soil, complete all as specified and as directed by Engr-in-Charge.
Taking proper shut down in writing and Spray painting of transformer at site with one coat of weather proof grey synthetic enamel paint after removing all dust, rust, carbon and oily spots, including well preparation of surfaces and writing /marking SM/MES No as 25mm stencil using white paint complete all as specified including cleaning of temperature gauge and silica gel ,oil temperature level for transformer rating 160 KVA to 315 KVA complete, all as specified and directed by Engr-in-Charge.
Taking proper shut down in writing and disconnecting up the LT and HT electric mains from transformer of capacity 160 KVA to 315 KVA, removing from pole structure / platform shifting to near by suitable location by using crane and any other equipment and reconnecting with existing electrical system of HT and LT electrical mains including commissioning and testing complete, all as directed by Engineer-in-Charge Note :-Temp arrangement will be provided by the Contractor.
MOHAN LAL AND SONS
proach associates
FANGALIA TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .