Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹67.5 LAdmitted-Finance RZ M 21 NAND BLOCK MAHAVIR ENCLAVE PALAM NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | L1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | JAI SAI ENGINEERING L1 |
|---|---|---|---|---|
| 1.00Supplying and making following type of cable end jointing with cast resin compound, including lugs and other jointing materials, for following size of 3 core, XLPE aluminium conductor (armoured) cable of 11KV/22KV grade i/c cutting, removing the existing faulty cable end termination wherever required etc. complete as required. (Note: Make of jointing kit- Denson/ Raychem or equivalent) | ||||
| 1.01 | Indoor Type Joint for cable-sizes 95sq.mm. to 185sq.mm. | 4 | Each | 14,300 ₹57,200 Lowest |
| 1.02 | Indoor Type Joint for cable-sizes 240sq.mm. to 300sq.mm. | 2 | Each | 18,250 ₹36,500 Lowest |
| 1.03 | Outdoor Type Joint for cable-sizes 95sq.mm. to 185sq.mm. | 4 | Each | 18,250 ₹73,000 Lowest |
| 1.04 | Outdoor Type Joint for cable-sizes 240sq.mm. to 300sq.mm. | 2 | Each | 24,200 ₹48,400 Lowest |
| 1.05 | Straight through Type Joint for cable-sizes 95sq.mm. to 185sq.mm. | 4 | Each | 25,650 ₹1,02,600 Lowest |
| 1.06 | Straight through Type Joint for cable-sizes 240sq.mm. to 300sq.mm. | 2 | Each | 31,600 ₹63,200 Lowest |
| 2.00 | S.I.T.C. of electronic Inverse definite minimum time relay including complete wiring, dismantling & removing existing faulty relay etc. complete as required. (Make- L&T/ Crompton/ ABB) | 4 | Each | 27,450 ₹1,09,800 Lowest |
| 3.00 | S.I.T.C. of Vaccum interrupter bottle suitable for existing 11KV/22KV VCB of 400A/630A (Make: Alstom/ Kirloskar/ ABB/ Areva/ Crompton) including dismantling & removing existing faulty Vacuum interrupter bottle, making connections & high voltage testing etc. complete as required. | 2 | Each | 1,23,500 ₹2,47,000 Lowest |
| 4.00Supplying, laying in existing trench/ duct/ pipe or on existing surface, fixing, testing and commissioining of following size of 3 core Aluminium conductor armoured XLPE insulated power cable of 11KV(UE)/22KV(E) Grade, duly ISI marked (IS: 7098 Part-2/1985 with latest amendment) etc. complete as required. (Note: Cable end termination shall be measured and paid separately; however any existing HT cable if required to be disconnected, dismantled and removed, the same shall be carried out by the agency in this item for which nothing extra shall be paid) | ||||
Tender Value
Refer Docs
EMD Value
₹1.2 L
Closing Date
21 Dec 2020, 3:00 pmClosed
SENIOR MANAGER (ELECT) Z5
O/o. SM(E) Z5, 3rd flr, TE Building, Sector 11, CBD Belapur, NM
Essential works for 11KV 415V 22KV 415V Electric sub stations under Zone 5 MTNL Mumbai
2020_MTNL_602397_1
SM(E)Z5/20-21/09
Open Tender
Electrical Works
Works
90 days
ZONE 5 AREA
As per NIT Document
2 documents required · 2 mandatory
₹1,180
Accounts Officer (CASH-BW), MTNL Mumbai
₹1.2 L
Yes
31 Dec 2020
10 Dec 2020
22 Dec 2020
10 Dec 2020
21 Dec 2020
10 Dec 2020
10 Dec 2020 - 18 Dec 2020
Amount
Supplying and making following type of cable end jointing with cast resin compound, including lugs and other jointing materials, for following size of 3 core, XLPE aluminium conductor (armoured) cable of 11KV/22KV grade i/c cutting, removing the existing faulty cable end termination wherever required etc. complete as required. (Note: Make of jointing kit- Denson/ Raychem or equivalent)
Indoor Type Joint for cable-sizes 95sq.mm. to 185sq.mm.
Indoor Type Joint for cable-sizes 240sq.mm. to 300sq.mm.
Outdoor Type Joint for cable-sizes 95sq.mm. to 185sq.mm.
Outdoor Type Joint for cable-sizes 240sq.mm. to 300sq.mm.
Straight through Type Joint for cable-sizes 95sq.mm. to 185sq.mm.
Straight through Type Joint for cable-sizes 240sq.mm. to 300sq.mm.
S.I.T.C. of electronic Inverse definite minimum time relay including complete wiring, dismantling & removing existing faulty relay etc. complete as required. (Make- L&T/ Crompton/ ABB)
S.I.T.C. of Vaccum interrupter bottle suitable for existing 11KV/22KV VCB of 400A/630A (Make: Alstom/ Kirloskar/ ABB/ Areva/ Crompton) including dismantling & removing existing faulty Vacuum interrupter bottle, making connections & high voltage testing etc. complete as required.
Supplying, laying in existing trench/ duct/ pipe or on existing surface, fixing, testing and commissioining of following size of 3 core Aluminium conductor armoured XLPE insulated power cable of 11KV(UE)/22KV(E) Grade, duly ISI marked (IS: 7098 Part-2/1985 with latest amendment) etc. complete as required. (Note: Cable end termination shall be measured and paid separately; however any existing HT cable if required to be disconnected, dismantled and removed, the same shall be carried out by the agency in this item for which nothing extra shall be paid)
Supply and fixing of spring-loaded TNC switch (having three positions Trip, Neutral & Close) to TRIP or CLOSE the Circuit breaker in HT Panel complete with wiring, connections, testing etc. complete as required.
Supply, fixing, connecting, testing and commissioning of D.O. fuses (20A to 100A) for 11KV to 22 KV H.T. Panel etc. complete as required.
Supply, fixing, connecting, testing and commissioning of HRC fuses (current rating: 5A to 100A) for 11KV to 22 KV H.T. Panel etc. complete as required.
Supply and fixing of cluster type fixed contacts for 11KV-22KV HT VCB/OCB etc. complete as required.
Supply and fixing of top fix contact for LT ACB i/c testing etc. complete as required.
Supply and fixing of current transformer in existing 22KV HT panel having suitable CT ratio for protection and metering including testing wiring and installation in the existing H.T. panel including connections, testing and commissioning etc. complete as required as per site requirement.
Supply and fixing of current transformer in existing 11KV HT panel having suitable CT ratio for protection and metering including testing wiring and installation in the existing H.T. panel including connections, testing and commissioning etc. complete as required as per site requirement.
Supply and fixing of current transformer in existing LT panel, having suitable CT ratio up-to 2000/5 Amp for protection and metering, including testing, wiring, and installation in the existing LT Panel including connections, testing and commissioning etc. complete as required as per site requirement.
Servicing of 400Amp to 800Amp HT OCB / VCB complete with cleaning, alignment, adjustment of gaps between phase to phase, lubricating all moving parts, adjustment for smooth mechanical operation etc complete as required.
Servicing of 400Amp to 630 Amp HT Isolator complete with cleaning, alignment, adjustment of gaps between phase to phase, lubricating all moving parts, adjustment for smooth mechanical operation etc complete as required
De-hydration of transformer oil with Filter machine at site to maintain the break down value, die electric strength of oil up to 50 KV including providing oil testing facility at site as reqd.
Supplying & filling the transformer oil, sealed pack drum including transportation charges etc. ( Make : M/S Power oil / Savita with ISI marked having 50KV R/C)
Supply & fixing of power pack unit having input 220 Volt AC and output 24/48/110 Volt DC i/c. making inter connection suitable for existing HT system etc. complete as required.
Checking & arresting at site for Oil Leakages from transformer of various ratings including (a) Dismantling of LT cable’s / Bus- Bar’s connections & dismantling of L.T. Bushing Rods. (b) Dismantling of Main Top cover / inspection window of Transformer. After draining of oil of Transformer into clean empty drums (as per requirement) c) Replacement of Cork rings set along with new Teflon rings of all phases for arresting oil leakages. d) Fixing of all terminals & Bus-bar’s connections & making adjustments. e) Replacement of cork gaskets, oil rings of inspection window side & Buckolz relay side & pipe line also for arresting leakages, if any. f) Re-filling of oil into transformer & examining of leakages for improving breakdown value of oil complete as reqd.
Servicing of 800 to 3200 Amp ACB Complete with cleaning, alignment, adjustment of gaps between phase to phase, lubricating all moving parts adjustment for smooth mechanical operation etc complete as required.
Supplying, installing, testing and commissioning of 3pole, 50kA, 415V, Manual draw-out type air circuit breaker of following full-load current rating, in the existing LT/MV panel i/c carrying-out required modifications in the panel, in the associated incoming/outgoing bus bars of the panel for proper mounting & connections of the ACB, also providing suitable interlocking connections, control wiring, end terminations etc. complete as reqd as per the site requirement. (Make: L&T/ABB /Siemens / Schneider )
Supplying, installing, testing and commissioning of 4 pole, 50kA, 415V, Manual draw-out type air circuit breaker of following full-load current rating, in the existing LT/MV panel i/c carrying-out required modifications in the panel, in the associated incoming/outgoing bus bars of the panel for proper mounting & connections of the ACB, also providing suitable interlocking connections, control wiring, end terminations etc. complete as reqd as per the site requirement. (Make: L&T/ABB /Siemens / Schneider )
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .