Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.6 CrAccepted-Finance | ₹6.6 Cr | L1 | Accepted-Finance L1 |
| 2 | L2₹6.7 Cr+₹7.9 L (1.20%)Accepted-Finance | ₹6.7 Cr+₹7.9 L (1.20%) | L2 | Accepted-Finance L2 |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Others-NOT RESPONSIVE |
Tender Value
Refer Docs
EMD Value
₹6.6 L
Closing Date
9 Jun 2022, 12:00 pmClosed
Executive Engineer
Office of the Executive Engineer, Capital Division-B, PWD, Itanagar
Construction Administrative Building for Dera Natung Govt. College, Itanagar
2022_PWDAP_748_1
CDB/NIC/2022-23/01
Open Tender
Civil Works
Item Rate
730 days
Itanagar
Please refer Tender documents.
4 documents required · 4 mandatory
₹2,000
EE, CD-B, PWD, Itanagar
₹6.6 L
Itanagar
29 Sept 2022
27 May 2022
11 Jun 2022
27 May 2022
9 Jun 2022
27 May 2022
6 Jun 2022
Amount
SH 1: CIVIL WORK
EXCAVATION AND EARTH WORK
Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30cm size, saturated soil and rock), lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returing the stacked soil in 15cm layers, when required, into plinth sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m.
Re-filling excavated earth in foundations and plinth etc. in 15cm layer including ramming and watering etc. complete.
Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete.
CONCRETE WORK
Providing and laying in foundations and plinth cement concrete 1:4:8 (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) excluding the cost of centring and shuttering.
Providing and laying damp proof course 38mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 12.5 mm nominal size)
Extra for providing and mixing water proofing material in cement concrete work in the proportion recommended by manufacturers.
Applying a coat of hot bitumen (mashphalte 80/100 or equivalent) using 1.70 kg. per sqm. on damp proof course after cleaing the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
Making plinth protection 50 mm thick of cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 stone aggregate using 20 mm nominal size) over 75 mm bed of stone ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finsihing the top smooth.
R.C.C. WORK
Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in: M20 (1 cement : 1.5 cparse samd : 3 stone aggregate 20mm nominal size)
Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1:3 (1 cement : 3 fine sand) of thickness not exceeding 6mm to give a smooth and even surface but excluding cost of centring, shuttering and reinforcement. a. M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20mm nominal size).
Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1:3 (1 cement :3 fine sand) of thickness not exceeding 6mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. a. M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20mm nominal size).
Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size)
Reinforced cement concrete in chajjas exceeding 15mm in thickness upto floor two level including centring and shuttering complete but excluding the cost of reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20mm nominal size)
Reinforced cement concrete in stairs (excluding landings) including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size)
Reinforced cement concrete in retaining wall (any thickness) including attached pillasters, buttresses, plinth and string courses, fillets etc from top of foundation up to floor two level excluding cost of centring,shuttering and reinforcement in : a) M20 (1 cement : 1.5 Coarse Sand : 3 stone aggregate 20 mm nominal size).
Centring and shuttering including strutting, propping etc. and removal of form work for: Foundation, footings, bases of columns etc. and mass concrete.
b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5m height)
Lintels, beams, girders, bressumers and cantilevers etc.
Column, pillars, posts and struts etc.
Stairs
STEEL REINFORCEMENT
Reinforcement of RCC work including bending, binding and placing in position complete. b) Tar/ TMT steel
BRICK WORK
Brick work with best available local bricks in foundations and plinth in cement mortar 1:4 (1 cement : 4 fine sand).
Extra for brick work with best available local bricks in superstructure above plinth level up to floor two level.
Half brick masonry (with best available local bricks) in cement mortar 1:4 (1cement: 4 coarse sand) in foundation and plinth.
ROOFING AND TERRACING
Lime concrete terracing on roofs average thickness 10 cm laid to fall with 25 mm gauge brick ballast and 50% mortar consisting of 1lime putty and 2 surki finished with gur and belgiri treatment complete.
Grading Roof for water proofing treatment with: Lime Concrete with 20mm nominal size brick aggregare & 50% lime mortar 1:2 (1 lime putty :2 surkhi)
Providing gola 75 x 75 mm in cement concrete 1:2;4 ( 1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge) including finishing with cement mortar 1 : 3 ( 1 cement : 3 fine sand) as per standard design :
Providing and laying four courses water proofing treatment with bitumen felt over roofs consisting of first and third courses of blown or/ and residual bitumen applied hot @ 1.45kg per sqm. of area for each courese, second course of roofing felt type-3 grade-1 (hessian base self finished bitumen felt) and fourth and final course of stone grit 6mm and down size or pea size gravel spread at 6 Cu.dm. per sqm. including preparation of surface excluding grading complete.
Providing and fixing on wall face C.I Rain water pipes including filling the joints with spun yarn soaked in neat cement slurry & cement mortar 1:2. 100 mm diameter
Providing and fixing M.S. Holder bat clamps of approved design of C.I. or S.C.I. pipes embedded in and including cement concrete block 10mm x 10cm x 10cm of 1:2:4 mix (1 cement : 2 coarse sand: 4 stone aggregate 20mm nominal size) including cost of cutting holes and making good the wall etc. 100 mm diameter
Providing and fixing on wall face C.I. accessories for rain water pipes including filling the joints with spun yarn soaked in neat cement slurry and cement mortar 1:2 (1 cement : 2 fine sand)
b)- CI Plain Bend-100mm dia
b)- CI Plain shoe-100mm dia
Making khurras 45 x 45 cm with avg. minimum thickness of 5 cm cement concrete 1 : 2 : 4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1 mm x 1 m x 400 micron, finished with 12 mm cement plaster 1 : 3 ( 1 cement : 3 coarse sand) and finishing the outlet complete as per drawing.
Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge.
WOOD WORK
Providing approved best local wood ( Class-B II) work in frames of doors , windows clerestory windows and other frames , wrought framed and fixed in position.(490.30 per Ten Cudm)
Providing and fixing flush door shutters, decorative type, core of black board construction with frame of 1st class hard wood and well matched 1st class teak ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. a) 40mm thick including anodized aluminum butt hinges with necessary screws.
Providing and fixing 40 x 3 mm flat iron hold fasts 40 cm long including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embedding in cement concrete block 30 x 10 x 15 cm in 1 : 3 : 6 (1 cement : 3 sand : 6 hard stone chips 40 mm nominal size).
Providing and fixing aluminum handles anodised transparent or dyed to required color or shade with necessary screws etc complete. 100 mm
Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessary screws etc complete. a) 300 x 10 mm
Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc complete. a) 300 x 16 mm
Providing and fixing 50 cm long aluminum kicking plate 100x3.15mm anodised, transparent or dyed to required color or shade with necessary screws etc. complete.
Providing and fixing chromium plated finished 100mm mortice latch and lock with 6 levers and a pair of CP handles with necessary screws etc.
Providing and fixing aluminium floor door stopper anodised ( anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws, etc. complete. a) Twin rubber stoper (Except Toilet doors)-D3
FLOORING
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption's less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 60x60 cm refer carpet area calculation
SKIRTING : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption's less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 12mm thick cement mortar 1:3 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete. size of tile 600x600 mm
Providing and fixing 1 st quality ceramic glazed wall tiles confirming to IS: 15622 ( thickness to be specified by manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of any sizes as approved by Engineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 Cement : 3 Coarse sand) and joining with grey cement slurry @3.30kg per sqm including pointing with white cement mixed with pigment of matching shade complete.
Providing and laying rectified Glazed Ceramic floor tiles of size 300x30 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete. sqm 1225.10 shades, except White, Ivory, Grey, Fume Red Brown laid on 20mm thick bed of Cement Mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigments etc., complete.
Providing and laying matt finished vitrified tile of size 100x100x16mm having water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in out door floors such as footpath, court yard multi models etc., laid on 20mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as direction of Engineer-in-Charge.
Providing and laying gang saw cut 18 mm thick, mirror polished pre moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in-Charge. With granite stone of area less than 0.50 sqm
STEEL WORK
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
FINISHING
12 mm thk cement plaster 1: 4( 1 cement : 4 coarse sand) on walls.
15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement :4 fine sand)
6 mm thick cement plaster ( 1 cement : 3 fine sand) to ceiling.
Applying one coat of cement primer of approved brand and manufacture on wall surface.
Finishing walls with water proofing cement paint of required shade :
Wall painting (two or coats) with plastic emulsion paint of approved brand and manufacture on new work to give an even shade.
Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works.
With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood works.
painting with synthetic enamel paint of approved brand and manufacture to give an even shade- 2 or more coats
Painting (two or more coats) on rain water, soil waste and vent pipes and fittings with aluminum paint of approved quality over a priming coat of ready mixed genuine red lead on new work.
Varnishing (two or more coats) with superior quality spar varnish of approved brand and manufacture brand and manufacture on new work including an under coat of flatting varnish with glue sizing.
ALUMINUM WORK
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and panelling to be paid for separately) : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-incharge. (Cost of aluminium snap beading shall be paid in basic item) With float glass panes of 4.0 mm thickness.
Providing and fixing stainless steel (SS 304 grade) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer-incharge complete. 255 X 19 mm.
Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS:1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/stainless steel screws @200mm centre to centre , including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section arcound the opening, all complete as per requirement and direction of Engineer-in-charge.(Only weight of grill to be measured for payment) windows area @ 2.07Kg/m.
DSR-25.2 Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels,
Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in-Charge. For payment, only the actual area of glass on face # 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevent Item*).“(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
SH:-2-Electrical works
POINT WIRING WIRING IN STEEL AND PVC CONDUIT
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm 20 mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet
TV antenna socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Installation, Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. For Data & CCTV 1 run of cable
2 run of cable
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC copper conductor single core cable etc. as required. insulated Group B
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
Supplying and fixing PVC batten/ angle holder including connections etc. as required.
MCCB, MCB & DB’S
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way , Double door ( UPS)
Supplying and fixing following way surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCBs & incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required) 8 way (4 + 24), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 A
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. For 8 way, Double door SPN MCBDB
Supplying and fixing Cable End Box (Loose Wire Box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc. as required.
CABLE TRAYS Hot Dipped Galvanized Iron Cable Tray
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
E A R T H I N G
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
LIGHTNING CONDUCTOR
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required.
Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
Laying copper/ G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
MV CABLE LAYING
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Above 185 sq. mm and upto 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.
MV CABLE JOINTING & END TERMINATION
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
2 X 10 sq. mm (19mm)
3½ X 185 sq. mm (57mm)
4 X 10 sq. mm (25mm)
4 X 16 sq. mm (28mm)
CONVENTIONAL FIRE ALARM & PUBLIC ADDRESS SYSTEM
Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required. 6 Zone
Supplying, installation, testing & commissioning of heat detector operating at 54ºC/57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required
Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required.
Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required.
Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required
Supplying, installation, testing & commissioning talk back slave station in surface/recess suitable for operation on simplex mode complete with P.T.T. knob & speaker/microphone enclosed in a M.S.(16 SWG)/ ABS box with break glass in front etc. complete as required.
PUBLIC ADDRESS SYSTEM
Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required.
Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required.
Supplying, installation, testing & commissioning of digital audio amplifier 75 Watt, 25V rms operating at 240 Volt AC Supply complete as required.
Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required.
CONDUITING & WIRING
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.
2 x 1.5 sq. mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm. For PA & CCTV
Supplying and fixing of following sizes of Steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in the case of recessed conduit. For FA
SUB DISTRIBUTION PANEL
Sub Distribution Panels
The Main Panel in Electrical room shall consists of:
INCOMER
Main Incomer 250 amps TPN MCCB (35KA) terminals suitable to receive 1 x 3.5 x185 sq. mm XLPE AL.AR. cable connection on one side and Busbar connection on the other side.
BUSBARS
300 Amps TPN busbar, chamber of suitable length with aluminium busbars. All busbars and interconnections shall be of suitable size aluminium strips current density of aluminium shall not be more than 0.8 Amps/ sq.mm.
INDICATING PANEL
3 nos phase indicating lamps each backed up with MCB and switch shall be provided for incomer.
Provide Intelligent Panel Meter - Scheinder -Model No-EM-6400NG (96 mm x 96 mm) covering 25 electrical parameters with RS 485 port for incomming feeder.
OUTGOINGS
2 Nos. 100 A TPN MCCB (25 kA) terminals suitable to receive cable on one side and wire connection to Bus bars..
10 Nos. 63 A 4P MCB (10 kA) terminals suitable to receive cable on one side and wire connection to Bus bars..
8 Nos. 40 A 4P MCB (10 kA) terminals suitable to receive cable on one side and wire connection to Bus bars..
Main panel as described above and specifications complete.
The SDB UPS in Electrical room shall consists of:
INCOMER
Main Incomer 100 amps TPN MCCB (25KA) terminals suitable to receive 4 x 1 x 16sq. Mm copper cable connection on one side and Busbar connection on the other side.
BUSBARS
150 Amps TPN busbar, chamber of suitable length with copper busbars. All busbars and interconnections shall be of suitable size copper strips current density of copper shall not be more than1.6 Amps/ sq.mm.
INDICATING PANEL
3 nos phase indicating lamps each backed up with MCB and switch shall be provided for incomer.
Provide Intelligent Panel Meter - Scheinder -Model No-EM-6400NG (96 mm x 96 mm) covering 25 electrical parameters with RS 485 port for incomming feeder.
OUTGOINGS
8 Nos. 40 A DP MCB (10 kA) terminals suitable to receive cable on one side and wire connection to Bus bars..
SDB UPS as described above and specifications complete.
TELEPHONE SYSTEM
Rates of only ISI marked conduits, cables, switches and socket outlets have to be taken in the following items. Unless and otherwise specified, only such conduits, cables, switches and socket outlets shall be used in the work.
Providing and fixing of Krone make Telephone Tag Block of following pairs consisting of necessary Back Mount Frame, disconnection modules and grommets complete as required.
50 pair Telephone Tag Block
Supply,drawing and making connections with Telephone Main Junction box and Telephone Junction Box with annealed tinned copper conductor (ATC) , PVC insulated and PVC sheathed GI strip armoured Telecommunication cable in False Ceiling/on ceiling from the P & T Junction Box to the Main Telephone junction box including supporting arrangements from the roof complete with all accessories as required.
20 pair ( 0.61mm ) armoured Telephone cable.
SUPPLY OF LIGHTING FIXTURES & FANS
Supplying the following Lighting fixtures including lamps at site. Rate shall include all taxes and duties, transportation etc. complete. Samples of all light fixtures to be submitted to the client for approval prior to procurement of fixtures)
All Light Fixture shall be with H.F. electronic ballast ( THD less than 11% and P.F. 0.95 )
14 watts LED light Fixture as per Philips Cat. No.DN296B LED 15 S PSU
2 x2 Watts LED Light Fixture Philips Cat.RC380B LED 36S PSU or equivalent complete as required
Surface Mounted LED Light Fixture Philips Cat.SM251LED 16S PSU or equivalent complete as required
Emergency exit light
48" dia (1200 sweep) double ball bearing ceiling fan Crompton/Usha/ Havels
12" dia 1 phase exhaust fan, 1400 RPM (Havels make)
Supply of gravity and bird guard screen louvers for exhaust fan
CABLE WORK
Supply and laying, effecting proper connections, testing & commissioning of the following sizes of 1.1 KV armoured XLPE / unarmoured Cross linked polyethylene insulated, PVC sheathed (XLPE), conforming to IS: 7098 (Part-1)- 1988 ( 90 deg C) aluminium /copper conductor cables conforming to IS : 1554 and IS 694 for Flexible copper cable Part I - 1976 with latest amendments laid over MS supports in existing RCC ducts/ laid in ground /laid on Cable Trays including clamping the cables to supports in an approved manner as required complete with all accessories.All cables shall have thermo setting insulation XLPE and low emission of smoke and corrosive gas when affected by fire
1c x 16 sq.mm FR PVC insulated flexible copper conductor cables (For Inverter)
4 c x 16 sq.mm armoured XLPE insulated aluminium cable
4 c x 10 sq.mm armoured XLPE insulated aluminium cable
2 c x 10sq.mm armoured XLPE insulated copper cable
3.5 c x 185 sq.mm armoured XLPE insulated aluminium conductor cable
NETWORKING SYSTEM
DATA HORIZONTAL COMPONENTS
Cat 6 Information Outlets - Blue -Active DATA (User side)
Cat 6 24 Port Jackpanel - loaded- A DATA
Faceplate-Single
Patchcords- CAT 3 fts-Blue- ( RJ45-RJ45 ) for Field & Resource side (Active Data)
15 U Wall Mounted Networking Rack with accessories
Power Distribution Channel ( 6 Points - 5A Socket) - Vertical
Installation, terminating, crimping, commissioning, testing, penta scaning, documentation and certification of voice/data outlet with all fixing accessories
IP CCTV SYSTEM
Supply, Installation, Testing & Commissioning of IP Based CCTV System comprising of following:
Supply, Installation, Testing and commissioning of 2.0 MP IP Dome Camera, True Day Night camera with IR Illuminator, 1/2.8" CMOS or better, 2 MP @ 25fps, Min. Illumination required 0.01 lux @F1.4 (color) Lux IR On, AGC - Auto/Manual, 120dB True WDR, Min. Pixels 1920 x 1080 , triple stream, Wide Angle lens 2.8 mm IR corrected lens with angle of view of 120° or better, BLC, HLC, 3DNR, high power LEDs IR with upto 20m IR distance PoE, H.264 High Profile and MJPEG, PoE and 12V DC including cable termination and fixing accessories complete in all respect as per instruction of engineer in-charge.
Supply Installation Testing & commissioning of 2MP IP IR BULLETT CAMERA 2MP IR Outdoor Bullet camera with Motorised Vari-focal Lens,1/2.8" Progressive Scan CMOS, ICR, 0.014Lux/F1.4, 0 lux with IR, Slow shutter, 1920x1080 : 25/30fps, 2.8~12mm/F1.4 Motorized VF lens, H.264/MJPEG/MPEG4, Triple-Stream, Support Intrusion detection, scene change detection, Line crossing detection, motion detection, Support SD/SDXC Card up to 64GB, UP to 30m IR, IP67, DC12V/PoE, Full HD, DWDR, 3D DNR, HLC, Smart IR, 30m IR ONVIF, UL LISTED. CERTIFICATE CE & FCC.
16 Chanel Network Video Recorder Suitable for 30 days 24 hrs recording hard disk capacity Including providing syitable software complete as required etc.
Viewing Station
Intel® i7 2600 3.4Ghz/ or higher,» 4 GB of RAM DDR 3 or more » 80 GB of SATA II hard disk for OS & Application or more » 2 GB Graphics Card with 3 Monitor Output » 1600 x 1200 or higher screen resolution » 10/100/1000 Ethernet Network Interface Card » 16x ( HP Make ) Client scope
Supply/Installation/Testing/Commissioning of 32” CCTV color LED Monitor i and all accessories cable connections etc. complete as required.
Networking
Cat 6 24 Port Jackpanel - loaded- A DATA
S/I/T/C of Managed Layer 2 POE Ethernet Switch with 24 channel port 10/100/1000 Mbps including lockable racks and other accessories (Max .data transfer rate is 1 GB/S )
6 U rack for CCTV Application Server & Storage
Cat 6 Information Outlets - Blue -Active DATA (User side)
Patchcords- CAT 6- 4 fts-Blue- ( RJ45-RJ45 ) for Resource side (Active Data)
UPS EQUIPMENT
Supply, installtion, Testing & commissioning of
Design, manufacture, supply, installtion, Testing & commissioning of 20 KVA/18 KW UPS (Input - three phase and Output - Three phase) unit as per specifications - Stand alone operation
Design, manufacture, supply, installtion, Testing & commissioning of set of sealed maintenance free Batteries for 20 KVA/18 KW UPS for 15 Minutes backup as per specifications. The cost shall includes asll MS rack and etc.
SH-3 :- Plumbing Works
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid,10 litre low level white vitreous china flushing cistern & C.P flush bend with fitting & C.I brackets,40mm flush bend,overflow arrangement with special of standard make and mosquito proof coupling of approved municipal design complete including painting of fitting and bracketss,cutting and making good the walls and floors wherever required. W.C pan with ISI marked white solid plastic seat and lid.
Providing and fixing white vitreous china wash basin with C.I./M.S. brackets, 15 mm CP brass pillar taps, 32 mm CP brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : Flat back wash basin size 550x450 mm with a single 15 mm CP pillar tap
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 250 mm
Providing and fixing CP Brass or MI trap for wash basin and sinks. b) 40 mm dia
Providing and fixing rubber plug for sink or wash basin.
Providing and fixing 600x450 mm bevelled edge mirror or superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleats with CP brass screws and washers.
Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes. 100 mm dia
Providing and fixing sand cast iron heel rest sanitary bend. 100 mm
Providing and fixing sand cast iron single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 100 x100x100 mm
Providing and fixing sand cast iron trap of self cleaning design with sand cast iron screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors. a) 100 mm inlet and 100 mm outlet
Painting sand cast iron soil spun soil waste vent pipes and fittings with paint of any color such as chocolate, grey or buff etc over a coat of primer (of approved quality) for new work. 100 mm diameter pipe
G I Pipes and Fittings
Providing and fixing GI pipes complete with GI fittings and clamps, including cutting and making good the walls etc. (internal work) 20 mm dia nominal bore
25 mm dia nominal bore
32 mm dia nominal bore
Concealed pipe including painting with anti-corrosive bitumastic paint, cutting chases and making good the wall 20 mm dia nominal bore
25 mm dia nominal bore
32 mm dia nominal bore
Providing and fixing brass full way valve with wheel of approved quality. 32 mm nominal bore
40 mm nominal bore
Providing and fixing ball valve (brass) of approved quality complete 25 mm nominal bore
Providing and placing on terrace ( at all floor levels ) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing CP brass bib cock of approved quality conforming to IS : 8931 20 mm Nominal bore
Providing and fixing brass stop cock of approved quality. 15 mm Nominal bore
Drainage System
Providing laying and jointing glazed stone ware pipe grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. 200mm diameter
Providing and laying cement concrete 1 : 5 : 10 (1 cement : 5 lime sand : 10 graded stone aggregate 40 mm nominal size) all around SW Pipe including bed concrete 15 cm thick as per standard design. 250mm
Constructing brick masonry manhole with 2nd class bricks in cement mortar 1: 5 (1 cement :5 fine sand) RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone single 20 mm nominal size), foundation concrete 1 : 4 : 8 mix (1 cement : 4 coarse sand : 8 stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) neatly finished complete as per standard design. a) Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 Kg (weight of cover and frame to be not less than 38 kg, (weight of cover 23 Kg and weight of frame 15 Kg).
Providing and fixing square mouth SW gully trap class SP-1 complete with CI grating brick masonry chamber and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg. as per standard design. 180x150mm size P type With common burnt clay FPS(non modular) bricks of class designation 7.5.
SH:-4- Septic tank
Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required, into plinth sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m.
Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.
Reinforced cement concrete in retaining wall (any thickness) including attached pillasters, buttresses, plinth and string courses, fillets etc from top of foundation up to floor two level excluding cost of centring,shuttering and reinforcement in : a) M20 (1 cement : 1.5 Coarse Sand : 3 stone aggregate 20 mm nominal size).
Centering and shuttering including strutting, propping etc. and removal of form for: c) Suspended floors, roofs, landings, balconies, shelves and access platform.
Reinforcement of RCC work including straightening, cutting, bending, placing in position and binding all complete. b) Cold twisted bar.
12 mm thk cement plaster finished with a floating coat of neat cement of mix: 1:4 (1cement :4 fine sand)
Constructing brick masonry manhole with 2nd class bricks in cement mortar 1: 5 (1 cement :5 fine sand) RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone single 20 mm nominal size), foundation concrete 1 : 4 : 8 mix (1 cement : 4 coarse sand : 8 stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) neatly finished complete as per standard design. a) Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 Kg (weight of cover and frame to be not less than 38 kg, (weight of cover 23 Kg and weight of frame 15 Kg).
Making soak pit 2.50 m dia 3 m deep with 45 x 45 cm dry brick honeycomb shaft and SW drain pipe 100 mmdia 1.80 m long complete as per standard design.
SH:-5 Pathway -155 M
Earth work in surface excavation not exceeding 30 com in depth but exceeding 1.5m in width as well as 10 sqm on plan including disposal of excavated earth upto 50 m and lift upto 1.5m disposed soil to be levelled and neatly dressed:
Providing and laying cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20mm nominal size) excluding the cost of centring and shuttering in:
Brick work with best available local bricks in foundations and plinth in cement mortar 1:4 (1 cemnet: 4 fine sand)
Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
Cast in Situ Cement Concrete M20 kerb (Construction of cement concrete kerb with top and bottom width 115 and 165mm respectively, 250mm high in M20 grade PCC on M-10 grade foundation 150mm thick, foundation having 50mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408). Using Concrete Mixer
M/s JG Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .