| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.9 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹46.8 L+₹3.1 L (7.12%)Rejected-Finance | L2 | Rejected-Finance BEING NOT L1 |
| Sl No | Description | Qty | Unit | United Enterprises L2 | DIAMOND ENTERPRISES L1 |
|---|---|---|---|---|---|
| 1.00 | Supply and fix in repair Switch piano flush type single pole one way 5 Amp , Make Anchor/ Havells Rio,Complete all as specified & as directed by Engineer-In-Charge.
Note applicable for BOQ item no 1 to 105 (a)contractor rep/ superviser shall be present at office of Engineer-In-Charge at 9AM every day for taking of instruction regarding repairs to be carried out on the day on priority,(b) alternative Electricians deploy in place of regular electrician has to work on sunday/holiday to attend faults/defects/complains.In case if electrician fails to rectify the faults then recovery shall be recovered from contractor s any due payment(c)The repair work on any single day may be order by Engineer-In Charge to be carry out in number of places/building in one day i.e in one buildings quantity of any of BOQ items to be carried may be one or more & number of BOQ items to be executed on any single day may also be one or more(d) Contractor shall not have any claim on account of order of one or more quantity of one or more items of BOQ that to be executed in one or more building and or area in any single day & even the same on any numbers of day during contract period(f) all above mentioned labour effect on this account is deemed to be included in quoted rates by the tenderer for all items of this tender.Note:1) Complaints/Defects will be rectified withen 8 Hrs of intimated time. if complaints not rectified, a recovery of an amount of Rs150/-per complains per day will be recoverd from the RAR/ FB , ii) Rates are inclusive of T&P required safety equipment, and transport required contractor shall arrange on his own arrangement, iii).Compliant given by any electronic media i.e SMS, email or whats app etc and in writting shall be count as valid compliant contractor to take immediate action within stipulated time as mention in note -1 above. | 280 | Each | 35 ₹9,800 | 26 ₹7,280 Lowest |
| 2.00 | Supply and fix in repair Modular switch one way 6 Amp,1 Module , Make Anchor/Roma/Complete all as specified & as directed by Engineer-In-Charge. | 120 | Each | 50 ₹6,000 Lowest | 80 ₹9,600 |
| 3.00 | Supply and fix in repair Modular switch one way 16 Amp, 1 Module , Make Anchor/ Roma,Complete all as specified & as directed by Engineer-In-Charge. | 80 | Each | 100 ₹8,000 Lowest | 175 ₹14,000 |
| 4.00 | Supply and fix in repair Modular bell push 6 Amp,1 Module , Make Anchor/ Roma/Legrand,Complete all as specified & as directed by Engineer-In-Charge. | 30 | Each | 90 ₹2,700 Lowest | 145 ₹4,350 |
| 5.00 | Supply and fix in repair Modular Fan regulator electronic step type 230 V 2 Module. Make : Anchor/Roma Complete all as specified & as directed by Engineer-In-Charge. | 50 | Each | 290 ₹14,500 Lowest | 430 ₹21,500 |
| 6.00 | Supply and fix in repair Modular Socket outlet 6A/16 Amps 2/3 pin combined 2 module Make : Anchor/Roma. ,Complete all as specified & as directed by Engineer-In-Charge. | 90 | Each | 150 ₹13,500 Lowest | 220 ₹19,800 |
| 7.00 | Supply and fix in repair Modular Socket outlet 6 Amps 2/3 pin combined 2 module Make : Anchor/Roma ,Complete all as specified & as directed by Engineer-In-Charge. | 130 | Each | 100 ₹13,000 Lowest | 125 ₹16,250 |
| 8.00 | Supply and fix in repair Bell push flush type 5 Amps. Make : Anchor/Havells Rio,Complete all as specified & as directed by Engineer-In-Charge. | 25 | Each | 35 ₹875 Lowest | 40 ₹1,000 |
| 9.00 | Supply and fix in repair Fan regulator electronic step type 230 V. 120W . Make : Anchor/Havells Rio.,Complete all as specified & as directed by Engineer-In-Charge. | 70 | Each | 240 ₹16,800 Lowest | 265 ₹18,550 |
| 10.00 | Supply and fix in repair Bell buzzer,AC 230 Volts single pole. Make : Anchor/Press Fit,Complete all as specified & as directed by Engineer-In-Charge. | 65 | Each | 60 ₹3,900 Lowest | 65 ₹4,225 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
4 Aug 2025, 6:00 pmClosed
GE AF OJHAR
GE AF OJHAR
REPAIR/REPLACEMENT OF UNSV OLD WIRING, FITTINGS, FIXTURES , INTERNAL ELECTRIFICATION, MAINT OF SOLAR WATER HEATER, GEYSER AND MISC WORK ITEMS OF INTERNAL ELECTRIFICATION AND METERING PANEL AT RAKSHANAGAR AND MAINT OF SEWAGE/ETP INSTALLATION 11 BRD AF
2025_MES_716119_2
8329/E8
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
OJHAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF OJHAR
₹90,000
Yes
13 Oct 2025
14 Jul 2025
6 Aug 2025
15 Jul 2025
4 Aug 2025
16 Jul 2025
Amount
Supply and fix in repair Switch piano flush type single pole one way 5 Amp , Make Anchor/ Havells Rio,Complete all as specified & as directed by Engineer-In-Charge. Note applicable for BOQ item no 1 to 105 (a)contractor rep/ superviser shall be present at office of Engineer-In-Charge at 9AM every day for taking of instruction regarding repairs to be carried out on the day on priority,(b) alternative Electricians deploy in place of regular electrician has to work on sunday/holiday to attend faults/defects/complains.In case if electrician fails to rectify the faults then recovery shall be recovered from contractor s any due payment(c)The repair work on any single day may be order by Engineer-In Charge to be carry out in number of places/building in one day i.e in one buildings quantity of any of BOQ items to be carried may be one or more & number of BOQ items to be executed on any single day may also be one or more(d) Contractor shall not have any claim on account of order of one or more quantity of one or more items of BOQ that to be executed in one or more building and or area in any single day & even the same on any numbers of day during contract period(f) all above mentioned labour effect on this account is deemed to be included in quoted rates by the tenderer for all items of this tender.Note:1) Complaints/Defects will be rectified withen 8 Hrs of intimated time. if complaints not rectified, a recovery of an amount of Rs150/-per complains per day will be recoverd from the RAR/ FB , ii) Rates are inclusive of T&P required safety equipment, and transport required contractor shall arrange on his own arrangement, iii).Compliant given by any electronic media i.e SMS, email or whats app etc and in writting shall be count as valid compliant contractor to take immediate action within stipulated time as mention in note -1 above.
Supply and fix in repair Modular switch one way 6 Amp,1 Module , Make Anchor/Roma/Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Modular switch one way 16 Amp, 1 Module , Make Anchor/ Roma,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Modular bell push 6 Amp,1 Module , Make Anchor/ Roma/Legrand,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Modular Fan regulator electronic step type 230 V 2 Module. Make : Anchor/Roma Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Modular Socket outlet 6A/16 Amps 2/3 pin combined 2 module Make : Anchor/Roma. ,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Modular Socket outlet 6 Amps 2/3 pin combined 2 module Make : Anchor/Roma ,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Bell push flush type 5 Amps. Make : Anchor/Havells Rio,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Fan regulator electronic step type 230 V. 120W . Make : Anchor/Havells Rio.,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Bell buzzer,AC 230 Volts single pole. Make : Anchor/Press Fit,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Ding Dong AC 230 Volts single pole. Make : Anchor/Press Fit,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Socket out let 2 in 1, 5 pin 5 Amps flush type. Make : Anchor/Havells Rio.,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Switch socket combination outlet 5 pin 6 Amps 16 Amps 2 in 1 flush type.Make: Anchor/Havells Rio.,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Switch socket combination outlet 5 pin 5 Amps 2 in 1 flush type Make : Anchor/Havells Rio.,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Plug top 3 pin 5 Amps Make Anchor/Leader/Cona
Supply and fix in repair Plug top 3 pin 15 Amps Make Anchor/Leader/Cona
Supply and fix in repair Lamp holder PVC/polycarbonate insulated body with back plate suitable for angle fittings. Make : Anchor/Havells Rio.,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Ceiling rose surface type, PVC/Polycarbonate isolated body size 50x28 mm three terminals. Make : AnchorHavells Rio.,Complete all as specified & as directed by Engineer-In-Charge.
Fixing only in repairs Miniature Circuit Breaker, 10 Ampere, MCB SP 10 Amps 240 volts Type C series.
Fixing only in repairs Miniature Circuit Breaker, 16 Ampere, MCB SP 16 Amps 240 volts Type C series.
Fixing only in repairs Miniature Circuit Breaker, 20 Ampere, MCB SP 20 Amps 240 volts Type C series.
Fixing only of tube light , POP light, ceiling light, Focus light or any type of light to be fix on wall /ceilling with the help of suitable size of nut bolt washer etc including all electrical connection connection as required at site ( Note - Material /store will be issued under schedule be )
Supply and fix in repair MCB SPN 32 to 40 Amps 240 volts 10 KA. Cat Part No-408617 Make : Legrand /Standard/L & T,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair MCB TPN 32 to 40 Amps 240 volts 10 KA. Cat Part No- 408680 Make : Legrand Standard L & T,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair MCB TPN 63 to 100 Amps 240 volts 10 KA. Cat Part No-408683 Make : Legrand Standard /L & T,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Sheet metal enclosure for DB’s 2 way 240 volts. Make : Standard/HPL/Legrand,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Sheet metal enclosure for DB’s SPN, with 200 amps rated bus bar , 4 way ,240 volts double door. Make : Standard/HPL/Legrand.,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Sheet metal enclosure for DB’s SPN, with 200 amps rated bus bar ,8 way ,240 volts double door. Make : Standard/HPL/Legrand.,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Sheet metal enclosure for DB’s TPN, with 200 amps rated bus bar , 4 way ,415 volts double door. Make :Standard/Legrand/L&T.,Complete all as specified & as directed by Engineer-In-Charge.
Supplying and fix in repair sheet metal enclousers with socket, plug top and MCBs, single pole and neutral enclouser with a two pin and earth plug and socket complete with one single pole MCB , single pole, 240 V of capacity 20 amps , complete all as specified and as directed by Engr-in-Charge.
Supply and fix sheet metal distribution board 415 Volt,Vertical TPN 4 Way with provision for DHx100 series MCCB of legrand make as incomer and SP/TP MCBs as outgoing as per IS including compact insulated bus bar and rounded neutral bar, door earthing complete double door surface/reccess mounting IP-43 protection of L&T Cat No DBVTL004GD or equivalent in Legrand/Siemens.,Complete all as specified & as directed by Engineer-In-Charge.
S&F MCCB TP ,Thermal magnatic with enclouser , 415 Volts,50 HZ, 30 KA, 100 Amps DU-100H Cat No CM9789400k2 of L&T or equivalent Model of Legrand, Siemens.,Complete all as specified & as directed by Engineer-In-Charge.
Supply & Fix in repairs MCB TP 32 Amps 415 volts 50HZ of Legrand Cat No 4086 58 or equivalent in L&T /Seimens. ,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair PVC rectangular board 100 mm x 100 mmx 50 mm deep. Make : Press Fit or equavelent ,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair PVC rectangular board 175mm x 100mmx50mm deep. Make : Press Fit or equavelent.,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair PVC rectangular board 200mmx150mmx50mm deep. Make : Press Fit or equavelent.,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair PVC rectangular board 250mmx200mmx50mm deep. Make : Press Fit or equavelent .
Repair of Point wiring with 1.5 Sqmm (nominal area) PVC ( FRLS) insulated sheathed copper stranded conductor cable run inconcealed /floor PVC medium grade conduit /cassing capping as reqd at site with all fittings such as bends, tee, junction boxes,etc with suitable size of 1.5 Sqmm PVC(FRLS) insulated copper earth continuity conductor connected to common earth dolly for one light/fan/call bell point complete all as specified and as directed by Engr -in -Charge. Note - Cutting and making good of chasis in wall/roof/floor is included in the qtd rates.
Supply and fixing CRYSTA LED Glass T8 tube rod with in built driver Double sided connection. 1x20 Watt (Double sided connection) (4 ft) . Make - Crompton Cat No TCS-726-20-65-SL-DP-NWH or Havells
Supply and fix 36W LED Ultra-modern recess mounting luminaire with high performance LEDs, maximum 36 W 2x2 LED Panel suitable for mounting in Armstrong / 2x2 Grid ceiling which provides soft-light and glare free symmetrical illumination with CRCA powder coated Housing with sheet thickness of min 0.4 mm and with min 50 mm fixture Depth / height with glare free high translucent milky high grade diffuser with min 0.8 mm thickness . High efficiency long life LED package in integral module with lumen efficacy of >140 lm/W and viewing angle of 120° to ensure better uniformity with minimum System Lumen of 4300 Lumens with CRI > 80, Color temperature 5500- 6500 K, THD < 10% and PF > 0.95,IP20 , IK03.Life class of 50,000 hrs. @ L70, Input Supply Voltage Range:140-270 V, Frequency :50-60 HZ; Internal Surge Protection: 4 KV; Protection : Reverse Polarity, Open & Short Circuit. DRIVER SAFETY REQUIREMENT STANDARDS :IS 15885-2-13, TEST REPORT TO BE SUBMITTED; PHOTO BIOLOGICAL SAFETY NORMS: IS 16108, TEST CERTIFICATE TO BE SUBMITTED; CERTIFICATION: LM 79 FOR LUMINAIRE LM 80 FOR LED SOURCE. Fixture with R mark and registration number. As per Crompton Cat Ref: LCTLRNE-36-CDL with 5 Year warranty from manufacturer or equivalent in Havells/Halonix
S & F in repairs and connecting up LED 22 watt inverter fitting 6500K 4 feet with 100 lumen/watt on AC & 450+-10% on DC,PC housing with off white end cap,ABS material off white with surge protection upto 4KV with inverter back up upto 3.5 Hrs & high voltage sustain capacity 440Vac@ 2Hrs ,internal wire PVC coated cable 0.75 sq mm RED/BLACK 12 CCA including all necessary fixing arrangements fastners ,holding brackets & screw etc complete. Crompton cat No LDINVGL22-CDL or equivalent in Philips/Havells ).
S & F in repairs and connecting up LED 20 watt fitting 6500K 4 feet with 120 lumen/watt,aluminum housing extruded in thermal conductive material with powder coated in white colour Extruded serration High Optically efficient plastic FR grade material in milky white,Spring Steel Nickel plated,Inj. Moulded engineering plastic Brown in colour Five year written warranty from manufacturer including 23/00.0076 size 3 core copper flexible wire from connector to ceiling rose/adoptor including all necessary fixing arrangements complete. Crompton cat No CCS-100-20-65-HL2-DP-NWH or equivalent in Philips/Havells/Wipro ).
S & F in repairs and connecting up LED 10 watt fitting 6500K 2 feet with 100 lumen/watt,aluminum housing extruded in thermal conductive material with powder coated in white colour Extruded serration High Optically efficient plastic FR grade material in milky white,Spring Steel Nickel plated,Inj. Moulded engineering plastic Brown in colour Five year written warranty from manufacturer including 23/00.0076 size 3 core copper flexible wire from connector to ceiling rose/adoptor including all necessary fixing arrangements complete. Crompton cat No CCS-103-10-65-SL-DP-NWH or equivalent in Philips/Havells/Wipro ).
S & F in repairs and connecting up LED 5 watt fitting 6500K 1 feet with 100 lumen/watt,aluminum housing extruded in thermal conductive material with powder coated in white colour Extruded serration High Optically efficient plastic FR grade material in milky white,Spring Steel Nickel plated,Inj. Moulded engineering plastic Brown in colour Five year written warranty from manufacturer including 23/00.0076 size 3 core copper flexible wire from connector to ceiling rose/adoptor including all necessary fixing arrangements complete. Crompton cat No CCS-103-05-65-SL-DP-NWH or equivalent in Philips/Havells/Wipro ).
Taking down existing copper/aluminum existing point wiring (light/fan/socket or power points) complete (fittings such as switches,ceiling roses,pendents, regulators, sockets etc to be measured saperatly) incl wooden battens and conduct etc & removing material as directed complete all as specified and as directed by Engr-in-Charge.
M&L for Point wiring with 1.5 Sqmm (nominal area) PVC ( FRLSH) insulated sheathed copper stranded conductor cable run in and including surface in wall/celling/floor PVC casing caping as per IS with all fittings such as bends, tee,junction boxes,etc of suitable size including 1.5 Sqmm PVC(FRLSH) insulated copper earth continuity conductor connected to common earth dolly and including PVC boxes with modular inner & surface plate suitable for housing modular switches, sockets,fan regulators etc for one light/fan/call bell point controlled by one 1- way switch complete all as specified and as directed by Engr-in-Charge.
All as per item no 46 but for One 5 Amps socket point on same/below board with other switches.
All as per item no 46 but for One 5amps switch socket point independent.
All as per item no 46 but for One 15amps switch socket power point
Point wiring with 1.5 Sqmm (nominal area) PVC ( FRLSH) insulated sheathed copper stranded conductor cable run in and including concealed in wall/floor PVC conduit not less than 20 mm as per IS with all fittings such as bends, tee,junction boxes,etc of suitable size including 1.5 Sqmm PVC(FRLSH) insulated copper earth continuity conductor connected to common earth dolly and including MS/GI sunken boxes with modular inner & surface plate suitable for housing modular switches, sockets,fan regulators etc for one light/fan/call bell point controlled by one 1- way switch complete all as specified and as directed by Engr -in -Charge.
All as per item no 50 but for One 5 Amps socket point on same/below board with other switches.
All as per item no 50 but for One 5amps switch socket point independent.
M&L for Point wiring with 2.5 Sqmm (nominal area) PVC ( FRLSH) insulated sheathed copper stranded conductor cable run in wall/floor PVC medium grade conduit not less than 20 mm as per IS with all fittings such as bends, tee, junction boxes,etc of suitable size including 1.5 Sqmm PVC(FRLSH) insulated copper earth continuity conductor connected to common earth dolly and including MS/GI sunken boxes with modular inner & surface plate suitable for housing modular switches, sockets,fan regulators etc for one light/fan/call bell point controlled by one 1- way switch complete all as specified and as directed by Engr -in -Charge. Note - Cutting and making good of chasis in wall/roof/floor is included in the qtd rates.
Supplying and fixing in repairs Modular white cover plate with frame, 3 Module, Make Legrand /Anchor Roma/Crabetree.
Supplying and fixing in repairs Modular white cover plate with frame, 6 Module, Make Legrand /Anchor Roma/Crabetree.
Supply & fix metal fiush mounting box 3 module.
Supply & fix metal fiush mounting box 6 module.
Supply & fix rigid non metelic PVC conduit not less then 20mm/Casing caping exclusive of boxes (junction/terminal) but inclusive of all tee,bends, elbow, reducer bell mount tube ends and fixing accessories such as coupler, lock nuts saddles, pipe hooks etc in surface in wall/celling/floor etc. complete all as specified & directed.
M&L wiring for circuit/ sub main wiring of 2x1.5 Sqmm + 1x1.5 Sqmm earth wire, alongwith eart wire PVC (FRLSH) insulated copper conductor, single core, 1100 v grade cable in surface/ recessed as required in PVC casing caping complete all as directed by Engr -in- Charge.
M&L wiring for circuit/ sub main wiring of 2x2.5 Sqmm + 1x2.5 Sqmm earth wire, alongwith earth wire PVC (FRLSH) insulated copper conductor, single core, 1100 v grade cable in surface/concealed as required in PVC cassing N capping complete all as directed by Engr -in- Charge.
M&L wiring for circuit/ sub main wiring of 2x4 Sqmm + 1x4 Sqmm earth wire, alongwith eart wire PVC (FRLSH) insulated copper conductor, single core, 1100 v grade cable in surface/ recessed as required in PVC casing caping complete all as directed by Engr -in- Charge.
M&L wiring for circuit/ sub main wiring of 2x6 Sqmm + 1x6 Sqmm earth wire, alongwith eart wire PVC (FRLSH) insulated copper conductor, single core, 1100 v grade cable in surface/ recessed as required in PVC casing caping complete all as directed by Engr -in- Charge.
Supply,install,testing and commissioning of indoor type cbical metering panel board outer shell made out of 3.15 mm thich MS sheet of size not less than 600X600XX300 mm and fixed on MS angle of suitable size on Wall/Floor withsuitable size of nut, bolt and washer , frame factory fabricated withfront openable 3 phase , 4wire 415 volt, 50 Hz, including taking down old existing electric meter and refixing the same in new metering panel incl all electrical connections complete all as specified and directed by Engr-in-charge and compriseing with following TPN aluminium bus bar 200 Amp insulated with colour coded heat shhrikable sleeve and shall be mounted on suitable size 'F' class insulators Incoming MCCB 63 Amps 16 KA ,415 Volts, 50 Hz, FP-01 No Out going MCB SP 40 Amp-04 No Space for installation of electric meter-04 No LED Indicating lamp -01 set of three
M&L for Cutting 450/300 mm size hole for exaust fan in existing wall and making good with plastering and matching colour, Plaster the cut edges and surrounding area to restore the wall surface and apply surface treatment and paint the patched area using match colour and texture to blend seamlessly with the existing wall. Note Remove all debris and clean the site after work.
S&F ceilling fan BLDC 1200 mm sweep operated on 230/240V AC,26 W Single phase electric supply ,5 star with remote in white in colour complete including connecting with 3 core stranded copper conductor cable cordas as per manufacture recommendation from ceiling rose to fan connector including writing MES No. on ceiling fan white synthetic enamelled paint complete all as per specified and directed by Engr-in- Charge . Make Havelles cat pt- Efficienia Neo BLDC or equivalent in Orient n & crompton
S&F Exhaust fan 300 mm sweep, 4 blade ( Mettallic type ) with louvers, operated on 230/240V AC Single phase electric supply complete duly grauted bolts in the wall fixed with nuts, bolt and washers complete matching with the existing including connecting with 3 core stranded copper conductor cable cordas as per manufacture recommendation from ceiling rose to exhaust fan connectorcomplete all as per specified and directed by Engr-in- Charge . Make Crompton, havells , Usha
S&F Exhaust fan 300 mm sweep, 4 blade ( PVC ) with louvers, operated on 230/240V AC Single phase electric supply complete duly grauted bolts in the wall fixed with nuts, bolt and washers complete matching with the existing including connecting with 3 core stranded copper conductor cable cordas as per manufacture recommendation from ceiling rose to exhaust fan connector complete all as per specified and directed by Engr-in- Charge . Make Crompton, havells , Usha
S&F Exhaust fan 250 mm sweep, 4 blade ( PVC ) with louvers, operated on 230/240V AC Single phase electric supply complete duly grauted bolts in the wall fixed with nuts, bolt and washers complete matching with the existing including connecting with 3 core stranded copper conductor cable cordas as per manufacture recommendation from ceiling rose to exhaust fan connector complete all as per specified and directed by Engr-in- Charge . Make Crompton, havells , Usha
S&F Exhaust fan 200 mm sweep, 4 blade ( PVC ) with louvers, operated on 230/240V AC Single phase electric supply complete duly grauted bolts in the wall fixed with nuts, bolt and washers complete matching with the existing including connecting with 3 core stranded copper conductor cable cordas as per manufacture recommendation from ceiling rose to exhaust fan connector complete all as per specified and directed by Engr-in- Charge . Make Crompton, havells , Usha
Disconnecting all existing electric supply and taking down carefully ceilling/ exhaust/cabin/wall fan of any make and sweep dismantlling blades, checking for repairs required ( Note: Repairs/ Replacement of spares shall be carreied under appropriate items. for C/fan, Exhaust fan . The item will be taken down and brought to MES yard for repairs, i.e overoiling,rewinding,replacement of bush/bearing, brazing/machine work, painting and after testing at MES store yard Cost for transportation from site to MES store yard & vice versa is deemeed to be included under the quoted rate.
Hanging/fixing only ceiling fans of any make and sweep connecting the complete with & including provision of copper conductor cord 3 core PVC insulated and sheathed 0.5 Sqmm from ceiling rose to exhaust fan connector and testing as directed and specified( Note: The exhaust fan shall be fitted with new set of clamps, rubber shackle split pins and top and bottom nut bolts etc.)
Hanging/fixing only exhaust/cabin/wall fan of any make or sweep connecting up complete with and including provision of copper conductor cord 3 core PVC insulated and sheathed from celing rose to fan connector & testing as directed and specified. ( Note: The Exhaust fan shall be fitted with new set of washers, nuts, rubber packing etc.)
M & L for Opening up of fan, motor of fan, cleaning stator,rotor, cleaning of all parts greasing oiling of bushes and bearing reassembling and testing for smooth functioning for celling fan 1200 mm sweep Note;-rate shall be quoted for taking down & refixing of ceiling fn after repair work
All as per item No 73 but for Exhaust fan 300/375/450mm sweep
M & L for removing the burnt winding and rewinding the fan with super enamelled copper winding wire of suitable gauge, insulating, putting sleeves etc complete all as specified and directed by Engineer-in-Charge for celing fan 1200 mm sweep
All as per item No 75 but for Exhaust fan 300/380 mm sweep
Supply only bearing/bush in repairs or replacement for celing fan 1200 mm sweep
All as per item No 77 but for Exhaust fan of any type
S&F in repairs Fan capacitor 2.5 MFD, 250 V.
Supply and fixing in replacement fan motor suitable for PCV exhaust fan 230/300 mm complete Note;-rate shall be quoted for taking down & refixing of exhaust ceiling fn afterrepair work
S&F fan clamp assembly consisting of nut, bolts, washers and split pin alongwith suitable size rubber real for mounting of fan down rod.
Disconnectiing of all electrical connections of the existing ceiling fan and taking down ceiling fan (any type/ sweep) from the ceiling and removing the existing down rod of the ceiling fan .
M&L for down rod 1000 mm long for ceilling fan of any make and sweep made out of medium grade GI tubing 15 mm dia duly painted with two coats of enamel paint and provision of holes for electric wire at top and bottom also arrangemnts for fittment of ceiling fan motor,clamp assembly and condensor all specified and directed by Engineer in charge
All as per item No 83 do but 1500 mm
S&F copper flexible twin twisted cable of size 23/ 0.0076 .
Supply & Fix in repair PVC perplex cover glove type with Base plate /holder not less than 8 inch dia suitable for Post top lantern including one nos 7/9 watt LED lamp complete all as specified and directed by Engineer- in-charge.Make - Surya/*havells.
Supply and fix 40mm dia bore galvanized iron tubing, light grade including all fitting for cable protection etc laid in floor or fixed to poles with clamps etc all as specified and directed.Make- Prakesh surya/Swastik/Jindal.
S&F louver complete for exhaust fan of size 300mm , made of iron/ aluminium (As Sample approved ) of matching colour with exhaust fan of suitable size ,duly grauted bolts in the wall fixed with nuts, bolt and washers and making good the plastering by matching colour with existing colour to the disturbed surface of wall complete
Disconnecting carefully water and electric connection from geyser, taking down carefully storage type water heater of any type and capacity and dismantling geyser by removing glass wool, thermostat, heating element for checking of defects, repalcement of defective thermostat, heating element of any capacity, indicating lamps (round/rectangular) flange assembly, top or bottom cover half round plate glass wool etc where required, cleaning of inner container by anti corrosive liquid removing scales repair by brazing, Re-assemblong of geyser and refixing at its original location and testing complete(Replacement of spares such as heating element , thermostat, indicating lamp, top and bottom cover, half round plate, glass wool heating flange assembly will be measured and paid under relevent items) all as directed
Supply, installation, testing and commissioning of storage type electric water heater of capacity 25 Ltrs, AC 240 Vot, 50 Hz. 5 star rating, verticle type duly fixed to existing wall where directed including suitable mounting bolts, nuts and washer duly grouted including necessary accessories such as safety valve, thermostat, NRV, inlet/ outlet water connection piece etc including writing MES No on geyser with white synthetic enameled paint complete all as specified and as directed Note: (i) Cutting and making good of chases in the wall/roof/floor is deemed to be included in the quoted rates (The wiring for geyser shall be independent from main DB of individual quarter to geyser power socket is deemed to be included in the quoted rates.
M&L for replacement of heating assembly (flange) made out of copper/steel as existing including heat resistance and leak proof gasket suitable for 25 ltrs capacity geyser all as directed Make : Ditzs/ Racold/ Shakti/Spheroat
All as per item No 91 above but for 35/50 lts capacity
S & F Power Board suitable for 50/35/25 Ltr Digital Square water heater /geyser as per sample Make : Jaquar or equilivalent
S&F in repair thermostat having range 0 to 100 C for geyser as original size of 25/35/50ltrs capacity geyser sutiable for Ditzs/ Racold/ Shakti/Spheroat Make.
S&F in repair heating element 2 KW with round or triangular base for 50 ltrs capacity geyser sutiable for Ditzs/ Racold/ Shakti/Spheroat Make.
S&F in repair heating element 1.5 KW with round or triangular base for 35 ltrs capacity geyser sutiable for Ditzs/ Racold/ Shakti/Spheroat Make.
S&F in repair lamp indicator with red colour 230 volts complete with fixing arrangement round or rectangular shape and size as per existing geyser suitable for Ditzs/ Racold/ Shakti/Spheroat Make.
S&F in repair cord flexible 230 volts 3 core 2.5 sqmm copper conductor PVC insulated and sheated cable from geyser to power point to each geyser all as directed
Supply and fix 15mm dia bor plug type bib taps, cast iron, screwed for iron pipe and fixed.etc all as specified and directed.Make- ISI.
S&F in repair stop valve cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for 15 mm bore iron pipe on existing position for geyser Make : Ditzs/ Racold/ Shakti/Spheroat
S&F in repair new galvanised steel water tubing 15 mm dia medium grade including all necessary new GI fittings and fixed complete to wall from tank to geyser in let/out let all as specified and as directed by Engineer-in-Charge for geyser Make : Ditzs/ Racold/ Shakti/Spheroat
Supplying and fix in repair sheet metal enclousers with socket, plug top and MCBs, single pole and neutral enclouser with a two pin and earth plug and socket complete with one single pole MCB , single pole, 240 V of capacity 20 amps , complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of microprocessor based single phase, AC electronic tamper proof static energy meter LCD display Electronic KWH meter of capacity 5-30 Amp, 240 Volts, 50 HZ, accuracy class 1 , KWh compact meter with pilfer proof meter bo with sealing screw provision base mounting, projection mounted Cat no- SPPB1310000002OC00 of Make:- HPL / L&T /
Supply, Installation Bldgs security lights LED street light fittings 45 watt with minimum110 lumen/ watt system lumen output .The luminaire should have cool white coloure temperature with minimum 5700 K. The luminaire housing should be made of pressure die cast aluminium Epoxy power coated with wether proof gasket for LEDs and control gear compartments, heat resistance toughened clear glass fixed with SS screw with IP 66 protection, Make Crompton CAT No CRP-417-45-57-SL-LM-NSG or equivalent in Havells/ Phillips. .complete all as specified and directed by Engineer- in-charge.
M&L for earthing in repair including taking out GI plate with pipes earthing lead fasteners etc and earthing complete with galvanised steel earth plate electrode 600x600x6mm thick,burried directly in ground (earth pit not less than 2.25 Mtr deep below ground level ) with top edge of the plate not less than 1.5 Mtr below normal ground level,connected to 4 mm dia GI earth wire as earth lead by means of bolts,nuts ,washer and check nut of galvanized steel, protected by and including GI pipe 40 mm bore (light grade) and connected to main switch / MCB DBs box point / LP test point as directed and including cement concret pit in 1:2:4 type B1 using 12.5mm graded aggregate, with cast iron miled steel frame embedded in the concrete enclouser fineshed flushed & CI cover 10 mm thick of size (300mmx300mm CI) having locking arrengment hinged to CI frame all as shown under electrical plate of SSR Pt - I 2009 and as directed including painting the external surface of chamber & cover with enamel paint in diffrent colour as directed and writing earth results & date of test carried out with white paint on black painted background, wiremesh funnel 20 mm bore GI pipe medium grade for watering adequate quantity of black soil and charcol and common salt in alternate layer of 15cm 3ft x 3ft thick all around the electrode including necessery excavation & earth work in any type of soil complete testing on completion all as directed. Note:- i) Filling the pit with black cottan soil brought at site. ii) The excavated soil will be removed & paid separtely.
M&L for Periodical maintenance of Effluent Treatment Plant (ETP) 6 KLD Effluent streams handling with - Cyanide, Chrome & Acid/Alkali, once in three month by checking & Testing all connected part complete all as directed by Engr-in-charge comprising with the following:- Checking the serviceability of following tanks and repair any leakage found and cleaning of tanks Cleaning of Acid Alkali, tank 2000 ltrs Cleaning of chrome tank 2000 ltrs Cleaning of chrome tank 2000 ltrs Cleaning of Neutalite tank 6000 ltrs Cleaning of Tube settelar tank 2000 ltrs Cleaning of Sludge tank 2000 ltrs Cleaning of Sand filter by removing sand and charcoal Cleaning of Carbon filter and removing filter Cleaning of filter Press Checked serviceability of Filter Press, Charcaol Filter (ACF), Bag filter System ,Pressure Sand Filter (PSF), Resin Filter (RF) and and cleaning the same as per OEM Instruction complete all as directed by Engr-in-charge General checking of all water and pump and servicing of motor including greasing of all parts
Supply only Caustic soda
Supply only Ferrous sulphate
Supply only Lime powder
Supply only Allum powder
Supply only Bleching powder
Supply only Hydocloric acid (HCL)
Supply only sand as per sample
Supply only Charcoal as per sample
Supply / Fixing Digital PH meter size 96X96 mX115 mm, range 0.00 to 14.00 pH, 220 Volt, AC, cailibrated on 7 PH Make as per sample.
Supply / Fixing Chemical dosing pump PT 200 max flow rate 6-25 LPH, 125 PSI/8.6 bar, 50 Hz, 45 watt Make as per sample.
Supply & Fixing reaction tank for Acid /alkali made of PP ( Poly propylene ) as per existing design, size , thickness and capacity ( Approx 2000 Ltrs ) with supporting frame work at ETP plant Tech area including all connection of water supply and electric supply as reqd at site for fully function of plant incl painting in blue colour and writting tank name with white in colour of suitable size complete all as specified and as directed by Engr-in-charge incl taking down old unserviveable tank.
Taking down existing unsv electric motor 3 phase, 415 volts, 50 HZ , capacity 0.5 to 01 HP motor of any make after disconnecting all electrical connection and shift to workshop for repair. Dismantling the motor , removing old burnt winding, cleaning the slots, checking and setting the stampings, providing a coat of insulating warnish, rewinding with super enamelled copper conductor winding wire of suitable gauge, packing the slots with insulating sleeves. drying in controlled temperature, re-assembling the motor with new set of bearings and connecting with its original place.
Taking down existing unsv electric motor 3 phase, 415 volts, 50 HZ , capacity 1.5 to 3 HP motor of any make after disconnecting all electrical connection and shift to workshop for repair. Dismantling the motor , removing old burnt winding, cleaning the slots, checking and setting the stampings, providing a coat of insulating warnish, rewinding with super enamelled copper conductor winding wire of suitable gauge, packing the slots with insulating sleeves. drying in controlled temperature, re-assembling the motor with new set of bearings and connecting with its original place.
Taking down existing unsv rusted iron base frame of suitable size of 1 HP/ 3 HP motor with pump at ETP Plant and supply and fixing New pump moter base brame as per existing size complete all as specified and as direceted by engr-in-charge.
Supply and fixing in replacement of filter press cloth as per existing size and sample
Supply and fixing in replacement gear oil for ETP pump motor
Taking down existing unsv electric motor 3 phase, 415 volts, 50 HZ , capacity 3 HP motor with shaft , supply and fixing new electric motor 3 phase, 415 volts, 50 HZ , capacity 3 KW motor with existing size of shaft with new set of bearings and connecting with its original place complete all as specified and as direceted by engr-in-charge.
Taking down existing unsv flange/head of existing electric motor 3 phase, 415 volts, 50 HZ ,and supply and fixing pump- head/flange suitable for 1 HP pump motor complete all as specified and as direceted by engr-in-charge.
Supply and fixing PVC Pipe 40 mm dia for water supply connection of various pump motor to tank complete all as specified and directed by Engineer- in-charge.
All as per item no-125 but PVC Elbow 40 mm dia
All as per item no-125 but PVC Tee 40 mm dia
All as per item no-125 but PVC Socket 40 mm dia
All as per item no-125 but PVC Union 40 mm dia
All as per item no-125 but PVC NRV 40 mm dia
All as per item no-125 but PVC Pipe 25 mm dia
All as per item no-125 but PVC Elbow 25 mm dia
All as per item no-125 but PVC Tee 25 mm dia
All as per item no-125 but PVC Socket 25 mm dia
All as per item no- 125 but PVC Union 25 mm dia
All as per item no-125 but PVC NRV 25 mm dia
All as per item no-125 but PVC Stop cock butter fly 15 mm dia
All as per item no-125 but PVC Stop cock butter fly 25 mm dia
All as per item no-125 but PVC Stop cock butter fly 40 mm dia
S&F PVC flexible wire 2.5 sqmm 4 core
S&F PVC Flexible pipe 20 mm dia
S&F PVC Conduit pipe 20 mm dia
S&F Multi function meter
S&F Indicating lamp
S&F MCB SP 2Amp
S&F MCB TP 6 Amp
S&F Contactor (MNX 09 , 3 Phase 1No+1NC as per sample
S&F Relay as per existing size
Material & labour to collect waste water and sludge sample from ETP technical area 11 BRD in container,sending it to govt acreeditted NABL lab/MPCB lab , to carry out chemical analysis as well as phisical parameter test fromapproved lab for following parameter (i) BOD (ii) COD (iii)total suspended solid (iv) Ph:7-8 (v) Cynide (vi)Nickel vi) Chromium Viii) Acidity ix) Alkalinity and collecting electroplating waste sludge (150 Kg approx) cake from ETP plant for disposal and depositing the sludge cake to Maharashtra Enviro power Ltd- Pune for its further disposal & depositing its receipt to Engineer-In Charge,
Supply & fix Fully Automatic Star Delta Motor starter 20 HP in sheet-steel enclosure type MK-1S (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph) and Relay Range 9-14
Disconnecting electrically and disengaging the AC Squirrel cage induction motor 3 phase 415 Volts, 50 Cycles, and taking out to local workshop induction motor25 HP/20 HP/15 HP for repair purpose including complete cleaning,varnishing ,reinsulation and replacement of DE /NDE bearings and greasing and including shifitng back to location as directed, installing, testing and commissioning after repair complete all as specified and directed. (note- Rewinding will be measure & paid seperately under relavant item of sch.)
Material & labour for Rewinding the motor with super enamelled copper winding wire with appropriate same gauge of existing coil with similar class of existing insulation as recommended by manufacturer with high quality normex insulating paper applying best quality insulating varnish on stator/rotor windings drying them completely, testing the insulations as directed by engr -in - charge
Pumping out continously raw sewage water & cleaning of underground raw sewage water well of size 4.87 mtr dia x 6.75 mtr deep by removing sludge and silt completely with the help of electric operated lift machine from the bottom of raw sewage water well scrapping out complete sludge from the side walls of sewage well with the help of wire brush. Stacking out complete sludge and silt at distance not exceeding 50 mtr from the pump house. Applying two coats of lime wash on side walls of sewage walls on interior & weather proof apex over primer on exterior surfaces of sewage wall and painting of inlet outlet pipe CI/DI/MS pipe at tank/sump at base,dome,pumpset & associated pipeline with synthetic enamel paint as directed by Engineer-In-Charge
Pumping out raw sewage water & Cleaning of Aeration tanks of size 9.15 mtr x 9.15 mtr x 4.50 mtr by removing sludge and silt completely with the help of electric operated lift machine from the bottom of aeration tank scrapping out complete sludge from side wall of Aeration tanks with help of wire brush stacking out complete sludge and slit at distance not exeeding 50 mtr from tank,and taking out sludge for further dispolal outsidde domestic area .Applying two coats of lime wash on side wall at interiour surfaces & weather proof apex over primer on exterior surfaces ,cleaning and clearing,bushes and vegetaion arround the tanks, painting of inlet outlet pipe CI/DI/MS pipe at tank/sump at base,dome,pumpset & associated pipeline with synthetic enamel paint all as specified and directed by Engineer-in-Charge .
Pumping out raw sewage water and Cleaning of final settling tank of size 11 mtr (dia) x 5 mtr deep by removing sludge and silt completely with the help of electric operated lift machine from the bottom of final settling tank . Scrapping out complete sludge from the side wall of final settling tank with the help of wire brush, stacking out complete sludge and silt at distance not exceeding 50 mtr from the sewage treatment plant. Applying two coats of lime wash on side walls interior surfaces & weather proof apex over primer on exterior surfaces of final settling tank, cleaning and clearing the bushes and vegetation around the area all as specified and directed by Engineer-in-Charge.
Pumping out raw sewage water & Cleaning of semi underground sludge sump by removing sludge and silt completely with suitable pump ,scrapping out complete sludge from the side wall of sump with the help of wire brush etc and cleaning with clear water. Removing and depositing the sludge and silt at distance not exceeding 100 mtr from sewage treatment plant.Applying two coats of lime wash on interier side of sump & weather proof apex over primer on exterior surfaces and painting of inlet outlet pipe CI/DI/MS pipe at tank/sump at base,dome,pumpset & associated pipeline(suction & Delivery) with synthetic enamel paint as directed by Engineer-In-Charge,cleaning the vegetation and bushes around the sump all as directed by Engineer-in-Charge.
M&L for Pumping out continously raw sewage water & cleaning of underground collection pit of size 5.2 mtr x 5.2 mtr x 4.8 mtr deep at MAP Booster by removing sludge and silt completely with the help of electric operated lift machine from the bottom of raw sewage water well scrapping out complete sludge from the side wall of sewage well with the help of wire brush. stacking out complete sludge and silt at the distance not exceeding 50 mtr from pump house. Applying two coats of lime wash on side wall of sewage well on interior & weather proof appex over prime on exterior surface of sewage wall and painting of inlet , outlet pipe CI/DI/MS pipe at tank/sump at the base, dome,pumpset & associate pipeline with synthetic enamel paint as directed by Engr-In-Charge.
M&L for Pumping out continously raw sewage water & cleaning of Equalisation tank at MAP STP of size 6.8 mtr x 5.8 mtr x 3.2 mtr deep by removing sludge and silt completely with the help of electric operated lift machine from the bottom of raw sewage water well scrapping out complete sludge from the side wall of sewage well with the help of wire brush. stacking out complete sludge and silt at the distance not exceeding 50 mtr from pump house. Applying two coats of lime wash on side wall of sewage well on interior & weather proof appex over prime on exterior surface of sewage wall and painting of inlet , outlet pipe CI/DI/MS pipe at tank/sump at the base, dome,pumpset & associate pipeline with synthetic enamel paint as directed by Engr-In-Charge.
M&L for Pumping out continously water & cleaning of clean water tank of size 5 mtr x 5 mtr x 1.5 mtr deep at MAP STP by removing sludge and silt completely with the help of electric operated lift machine from the bottom of raw sewage water well scrapping out complete sludge from the side wall of sewage well with the help of wire brush. stacking out complete sludge and silt at the distance not exceeding 50 mtr from pump house. Applying two coats of lime wash on side wall of sewage well on interior & weather proof appex over prime on exterior surface of sewage wall and painting of inlet , outlet pipe CI/DI/MS pipe at tank/sump at the base, dome,pumpset & associate pipeline with synthetic enamel paint as directed by Engr-In-Charge.
M&L for Pumping out continously water & cleaning of chlorine tank of size 2.3 mtr x 5.4 mtr x 1.8 mtr deep at MAP STP removing sludge and silt completely with the help of electric operated lift machine from the bottom of raw sewage water well scrapping out complete sludge from the side wall of sewage well with the help of wire brush. stacking out complete sludge and silt at the distance not exceeding 50 mtr from pump house. Applying two coats of lime wash on side wall of sewage well on interior & weather proof appex over prime on exterior surface of sewage wall and painting of inlet , outlet pipe CI/DI/MS pipe at tank/sump at the base, dome,pumpset & associate pipeline with synthetic enamel paint as directed by Engr-In-Charge.
Material & labour to collect waste(sewage) water sample from domestic area 11 BRD in container,sending it to govt approved NABL accreditted lab , to carry out chemical analysis as well as & phisical parameter & bacteriological parameter test from approved lab & rate quoted are deemed to be quoted with this item.) (Note : - Report from approved NABL lab shall be submitted (Testing of sample before treatment & after treatment will be treated as one job ) for following parameter (i) BOD (ii) COD (iii)SS (iv) Ph:7-8 (v) Outlet coliform (vi)Residual chlorine) , complete all as specified and as directed by Engneer-in-Charge.
Material and labour for repair,cleaning ,servicing of all the parts and carring out "B" check of 200 KVA DG set Engine Model No : 6CTAA-8-3-01 of Make CUMMINS INDIA LTD & alternarnator Model no UG127441 of Make STAMFORD,servicing of AMF panel and other auxilary units,commissioning and test run from authorised dealer of company complete all as specified & as directed by Engineer in charge.(Note :Spares required in the process of maintenance will be measured and paid separately but cost of labour charges for fixing are deemed to be included under quoted rates. complete sychronization of Controller with alternator /Engine using harness is included in the job )
Supply and Fix in repair Genset Harness , A030X917
Supply and Fix in repair Relay Assembly 0307-3086
Supply and Fix in repair Interface Harness A045H558
Supply and Fix in repair Engine Harness A030X912
Repairs to verticle type sewage handling pump set of Make :Kirloskar, Model No Dry/s type ,114 cu.m/hr discharge, and 25 HP capacity installed at sewage booster pump house ,dismantling the pump set carefully from its connected electric motor including disconnecting and taking out the electric motor,transporting the pumpset to workshop for complete overhauling the pump set with the following replacement/repairs of pump set respectively and Refixing and recommissioning of pump with motor in proper alignments and recommissioning ,testing of pump set to the complete satisfaction of Engineer in charge.
Supply and fix in repairs Gland Bush Split type
Supply and fix in repairs Impeller Nut
Supply & fix Ball bearing SKF of suitable size
supply & fix shaft sleeve gun metal
supply & fix Repair to bush cast alloy
Supply & fix Repair of Damaged oil seal
supply & fix Repair to the main spindle shaft
supply & fixRepair to the key and impeller
Repair/Replacement to the Existing coupling with tyre coupling including drilling required side of hole on either side
supply & fix in Replacement of terminal plate for electric motor
-Ditto- all as item No. 62 above but capacity 15 HP & discharge 106.00 Cu.M/Hr pump set.
Supply and fix in repairs Gland Bush Split type
Supply and fix in repairs Impeller Nut
Supply & fix Ball bearing SKF of suitable size
supply & fix shaft sleeve gun metal
supply & fix Repair to bush cast alloy
Supply & fix Repair of Damaged oil seal
supply & fix Repair to the main spindle shaft
supply & fix Repair to the key and impeller
Repair/Replacement to the Existing coupling with tyre coupling including drilling required side of hole on either side
supply & fix in Replacement of terminal plate for electric motor
Design & Supply, installation, testing & commissioning of FRP construction, Induced Draft, Cross flow Cooling Towers (single / multicell as mentioned below) of capacity 180 TR, complete with FRP basin, honeycomb design PVC fill, drift eliminators, hot water distributors, low noise adjustable pitch propeller type fan of FRP & Belt Driven along with casing, coupled with TEFC Squirrel cage induction motor weather-proof with cowl for outdoor installation. Basin shall be provided with accessories like quickfill, makeup & drain pipes, Pvc construction float valve, overflow pipe etc. Motor shall be suitable for 415V ± 10%, 50Hz ± 5%, 3-phase AC supply. Motor shall be suitable for VFD operation i.e. motor suitable for any low voltage & low frequency range due to speed variation through VFD without heating and noise generation. Separate motor shall be provided in each cell in case of multi cell towers. The fan / fan motor shall be isolated from the cooling tower structure . Each tower/ each cell shall be complete with its suitable HDG Steel ladder with safety cage as per specifications. The cooling tower shall be certified for test procedure as per CTI STD-201, Motors shall be TEFC, Squirrel cage induction motors, IP 66, Class F insulation. Motor Efficiency shall be as per ECBC 2017: ECBC: IE3, Cooling Towers Efficiency: As per Table 5.18 of ECBC-2017 1. The maximum allowable sound power at a distance of 3m from the equipment shall not be more than 75 dB(A) without sound deflector cowls. 3. 2. Each Cell of the tower shall have HDG Steel ladder with safety cage. Cooling Tower Type 1: Weather conditions of site location GE (AF) Ojhar as mentioned below: *Summer DBT / *Summer WBT: 110°F | 75°F *Monsoon DBT /* Monsoon WBT: 95°F | 83°F Wet bulb temp. to be considered for cooling tower sizing: 83°F Cooling Tower Approach: 7°F Condenser water OUT (Leaving Water Temp.) LWT: 89.6°F (Considered WBT + Cooling Tower Approach) Condenser water IN (Entering Water Temp.) EWT: 98.6°F Chiller capacity: 150 TR, Cooling Tower capacity: 180 TR (720 USGPM), Condenser water flow rate: 4 USGPM X TR of Chiller Capacity Cooling tower's capacity should be adequate for total heat rejection, which shall be the total chiller capacity (TR) plus the BHP of chiller motor (IKW of motor) i.e. motor heat. Cooling Tower as described above Complete all as specified and as directed by Engr-In-Charge. Make: ADVANCE / PAHARPUR / MIHIR. The rate quoted for shall include taking down existing cooling towers and depositing to MES yard and all misc works given as per manufacture in annexure viz all civil work/ foundation work , Earthwork, excavation, PCC/RCC/Brick work, MS Fabrication with existing MS pipes & fittings ,gasket and nut bolt washer etc, Electrical connection for making cooling tower completely operational under existing condition
M&L for repair & overhaulling of non clogging pumpset Make: Grundfos- Model No SE1.75.100.150.2.52S.C.N.51D resulting head of pump : 20.3 mtr, flow 48.2 LPS Type of impeller: S-Tube, Primary shaft seal : SIC-SIC, Secondary shaft seal : SIC-Carbon, Pump housing: Cast Iron EN-GJL250, Impeller: Cast Iron EN-GJL250, Motor: Cast Iron EN-GJL250, Material: Whole Pump in cast iron, Maximum current consumption: 29 A, Insulation class H, Power input P1: 17 KW, Rated power P2: 15 KW, Mains frequency: 50 Hz, installed at STP dry installation, taking down the pump set carefully with help of crane from existing position with connected electric motor transporting the pumpset to OEM authorised dealer workshop with following replacement/ repair of pumpset (a) opening it through its casaing for dismantling pump and motor and carrying out repair/ overhauling including cleaning of casing and impeller, clogged, discharge line and oil chamber (b) Taking out the electric motor and carrying out for overhaulling warnishing the same (c) Repairing the sleeves of the bearing & Repair of any major or minor defects (d) Refixing and recommissioning of pump with motor with proper alingment and recommissioning and test run from authorised rep of company, testing the pump set to the complete satisfaction ( 2 yrs performance warranty shall be submitted for pumps ) Complete all as specified and as directed by Engr-In-Charge. Replacement of following spare part mentioned hereafter in the process of the maintainance will be measured and paid seperately Note: Item mentioned under SI no 86-92 are to be executed from authorized dealer of appointed by OEM exclusively. Item no 86 to 92 are the spare required in the process of maintainance which shall be measured and paid seperately.
Supply and fix Kit, Shaft Seal Cartridge F52 2P A
Supply and fix Bearing set
M&L for Rewinding of motor with suitable gauge copper winding of insulation class (IEC 85) : H
Supply and fix O-Ring set for dry motor NBR
Supply and fix S moisture switch kit
Supply and fix Leakage switch
Supply and top up Oil
Supply only copper sulphate in granular form for removing algae from pool water, complete all as specified and directed by Engineer-In -charge
Supply only VG 320 gear oil of Make : Servo Veedol /suitable for worm type gear box complete all as specified & directed
Supply only poly ammonia chloride enclosed inside suitable container,Complete all as specified & as directed by Engineer-In-charge.
Supply only PH paper,Complete all as specified & as directed by Engineer-In-charge.
Material & Labour for disengaging motor from gear box,flexible coupling & turbine and blades from aeration tank ,complete Maintenance and Overhualing of surface aerator at STP complete greasing of movable parts,bearing, gear box,& associated SS-316 nut bolts and washers , Refixing and recommissioning of surface aerator with motor in proper alignments and recommissioning and test run from authorised rep of company of company and testing the pump set to the complete satisfaction & all as specified & as directed by Engineer in charge.
Supply and fix in repair CI foot valve 80 mm dia with flange end with replacement of existing foot valve.of make: L&T/Zoloto/BIR ,complete all as specified & as directed by Engineer-In-Charge
M&L for preparation of surface for board painting on MS display board of size 5x3 feet or more by scratching the board with emby paper and applying two coats of synthetic enamel paint of blue colour as approved and letter writing with white radium paint having font of size 3" to 1 inch including necessary fabrication/welding work of board, flling metal, applying support metal structure wherever required, complete all as specified and as directed by Engr-ln- Charge. Note: Painting of all display boards (Approx 10 nos. ) at E/M installations under AGE E/M at various location in Domestic area Technical Area, Raksha Nagar are deemed to be considered as 1 job.
M & L for cleaning the sludge line of CI pipe of 150mm dia from final settling tank to sludge pump (Appx length 25mtr) and removing sludge, blockages, deposites etc by using mechanical cleaners, strings, brushes etc.for proper flow of effluent for the functioning of installation all as specified and directed by Engineer-In-Charge.
United Enterprises (BID ID -3375804)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .