Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.5 LAccepted-AOC RZ 40 PALAM VIHAR DWARKA SECTOR 6 NEW DELHI 75 | NEW DELHI | DELHI | 75 | L1 | Accepted-AOC AOC | |
| 2 | L2₹22.7 L+₹2.0 L (9.63%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹23.3 L+₹2.6 L (12.6%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹23.8 L+₹3.1 L (15.1%)Rejected-AOC WZ 1391 31 B NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L4 | Rejected-AOC L4 | |
| 5 | L5₹24.7 L+₹4.0 L (19.3%)Rejected-AOC WZ 409 0 B 1ST FLOOR PLOT NO 12 JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | WEST DELHI | DELHI | 110064 | L5 | Rejected-AOC L5 |
Tender Value
₹29.7 L
EMD Value
₹59,460
Closing Date
20 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE(AF) Tughlakabad
HQ CWE(AF) Tughlakabad
CA NO. CWE/TKD/TOKEN-06/2020-21
2020_MES_354461_1
CA NO. CWE/TKD/TOKEN-06/2020-21
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) Tughlakabad
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE(AF) Tughlakabad
₹59,460
Yes
26 Aug 2020
20 Jun 2020
22 Jul 2020
20 Jun 2020
20 Jul 2020
8 Jul 2020
60 days
Amount
M&L for Dismantling the water mains from the delivery lines, lifting/taking up GI/CI Column pipes, pumping sets of any description upto 250 mtr depth including submersible cable after disconnecting pumping sets from cable, repairs to the defective submersible cable and jointing of submersible cable, pump and motors by using water proofing jointing kit, and also jointing of crack/leaked GI pipe with MS sheet jointing clamp,rubber sheet, nut, bolts and washer etc replacement of defective column pipes, and including Lowering of submersible pump Sets, submersible cable, column pipes, reonnecting main delivery mains as existing and testing for satisfactory running and continuous flow of water etc complete all as directed by Engineer in charge in bore wells at various locations. Note: 1 Repair to Motor & Pumping sets, cable and column pipes etc. shall be measured and paid seperately. 2. Contractor shall take proper precautions while lifting out and removing pump set from bore well so as to avoid any damage to column pipe and submersible cable. All necessary T&P and equipments required for lifting out and lowering pump set etc shall be arranged by the contractor at his own cost.
Dismantling and strip opening of submersible pump & motor of any description and in any position for servicing /overhauling, cleaning, oiling/greasing, fixing of serviceable parts in position, removing & replacement of defective / unserviceable parts with new parts and reassembling the pump and motor, ensuring proper alignment of pump and motor, fixing in position, connecting to existing system and testing at site on full load to the entire satisfaction of the Engineer-in-Charge for the following capacities pumps & motors :- (a) 30 HP, three phase, 415 Volts, 50 Hz, AC supply Note: - (i) The replacement of defective / unserviceable parts shall be measured and paid separately as “Supply only” under appropriate item of Sch ‘A’ and fixing rate for new items are deemed to include under these item. (ii) Burnt out windings of motor shall be replaced, measured and paid separately under appropriate item of Sch ‘A’ for rewinding. (iii) (a) The rates for above items are deemed to include transportation of pumps/ motors to and from workshop as approved by Engineer-in-charge for necessary repairs, alignment and testing of pump and motors at authorised workshop. (b) Re-metalling to Pump shaft, polishing and grinding and making standard size to matching with Gun Metal Bush / Neck-ring shall be measured and paid for separately under appropriate item of Sch ‘A’ (iv) Lifting of pump and motor from bore well and lowering of pump and motor after repairs shall be measured and paid separately under appropriate item of Schedule `A'.-
(b) 10 to 12.5 HP, three phase, 415 Volts, 50 Hz, AC supply
(c) 5 to 7.5 HP, three phase, 415 Volts, 50 Hz, AC supply
Taking out and removing old burnt out windings of the submersible/Non clog submersible electric motors of any description and in any position of 30HP, three phase, 415 Volts, 50 Hz, AC supply.capacity and rewinding of submersible electric motors with existing size PVC insulated, copper conductor as approved by the Engineer-in-charge including cleaning the slots with carbon- tetra-chloride solution before rewinding & testing on full load etc complete all as specified and directed :- Note : (i) The winding wire shall be of make ATLAS/FINOLEX (ii) The rate quoted by the contractor shall be deemed to include the cost of transportation from site to authorised workshop and back, fixing / lowering in position
(b) 10 to 12.5 HP, three phase, 415 Volts, 50 Hz, AC supply
(c) 5 to 7.5 HP, three phase, 415 Volts, 50 Hz, AC supply
Supply only in replacement of following defective spare parts of submersible motor of any description/make and capacity 05 to 12.5 Hp and in any positioin :-
(a) Bearing lower / upper housing of existing size
(b) Gunmetal bearing bush
(c) CI thrust plate
(d) CI thrust bearing
(e) Water seal
(g) Bearing bush rubber
(h) Turning and polishing of motor shaft including lathe work
Supply only in replacement of following defective spare parts of submersible motor of any description/make and capacity 30 Hp and in any positioin :-
(a) Bearing lower / upper housing of existing size
(b) Gunmetal bearing bush
(c) CI thrust plate
(d) CI thrust bearing
(e) Water seal
(g) Bearing bush rubber
(h) Turning and polishing of motor shaft including lathe work
Supply only in replacement of following defective parts of submersible pumps of any description/make and capacity 05 to 12.5 Hp and in any position :-
(a) Stage casing bowl (SS-410 material)
(b) Rubber bearing bush
(c) Stage casing gun metal bearing bush
(d) impeller of existing casing size capacity
(e) neck ring
(f) Defective Stainless steel sleeve
(g) NRV body suitable for any make of submersible pump
(h) MS coupling and key common suitable of pump shaft and motor shaft of any type of submersible pump.
(j) Stainer
Supply only in replacement of following defective parts of submersible pumps of any description/make and capacity 30 Hp and in any position :-
(a) Stage casing bowl (SS-410 material)
(b) Rubber bearing bush
(c) Stage casing gun metal bearing bush
(d) impeller of existing casing size capacity
(e) neck ring
(f) Defective Stainless steel sleeve
(g) NRV body suitable for any make of submersible pump
(h) MS coupling and key common suitable of pump shaft and motor shaft of any type of submersible pump.
(j) Stainer
Disconnecting the water mains from the suction and delivery pipe line of centrifugal pump sets/open well pump set of any description and in any position and taking out pump set / motor from the base frame including disconnecting electric connections and foundation, nuts and bolts. for servicing /overhauling, cleaning, oiling/greasing, fixing of serviceable parts in position, removing & replacement of defective / unserviceable parts with new parts and reassembling the pump and motor of capacity 5 HP capacity, ensuring proper alignment of pump and motor, fixing in position, connecting to existing system and testing at site on full load to the entire satisfaction of the Engineer-in-Charge. Note: - (i) The replacement of defective / unserviceable parts shall be measured and paid separately as “Supply only” under appropriate item of Sch ‘A’ and fixing rate for new items are deemed to include under these item. (ii) The rates for above items are deemed to include transportation of pumps/ motors to and from workshop as approved by Engineer-in-charge for necessary repairs, alignment and testing of pump and motors at workshop.
Ditto but for centrifugal pumps sets of capacity 7.5 HP to 12.5 HP capacity,
Ditto but for centrifugal pumps sets of capacity 40 HP to 60 HP capacity,
Supply only in replacement of following defective parts of centrifugal pump sets/open well pump sets
(a) Ball bearing for 5 HP Pump
(b) Ball bearing for 7.5 HP/10HP pump
(c) Ball bearing for 30/40 HP pump
(f) Gland Collar for 5 HP Pump
(g) Gland Collar for 7.5/10 HP pump
(h) Gland Collar for 30/40 HP pump
(k) Stainless steel bush for 5 HP Pump
(l) Stainless Steeel bush for 7.5 HP/10HP pump
(m) Stainless Steel bush for 30/40 HP pump
(n) Stainless Steel shaft for 5 HP pump
(q) Stainless Steel shaft for 7.5 HP/10HP pump
(r) Stainless Steel shaft for 30/40 HP pump
(t) Cast Iron Impeller for 7.5 HP/10HP pump complete with all accsessories.
(u) Cast Iron Impeller for 40 HP pump complete with all accsessories.
(v) Cast Iron Impeller for 60 HP pump complete with all accsessories.
(w) Gland packing off size suitable for pump set capacity 5HP to 60 HP
(x) M&L for Turning /remetalling and polishing of pump shaft with shaft key including lathe work.
(y) Rubber insersion sheet 3mm thick.
(z) Ball bearing grease superior quality in 1 KG containers(Make CASTROL)
(aa) MS Nuts, bolts and washers of various sizes as required.
Rewinding of 5 HP motor same gauge with super enamelled copper wire including removing burnt winding cleaning of slotes sepration of rotor and startor making insulation to all joint . and replacement of the following items.All as specified and directed by Engr-in- charge. (a) Replacement of ball bearing.Make: SKF-01 Nos (b) Replacement of cooling fan - 01 Nos. (c) Replacement of capacitor of suitable mfd (d) Replacement of seal, bush (e) Repair/replacement of shaft
(a) Ditto but for centrifugal motor of capacity 7.5 HP to 12.5 HP capacity,
(b)Ditto but for centrifugal motor sets of capacity 40 HP to 60 HP capacity,
Dismounting of monoblock 2 HP pump and motor from foundation including disconnecting all electric connection suction / delivery line connection and transporation to pumping set civil work shop and return to store after repair including Re- assembing of motor and testing and commissioning all as specified and directed.
All as per item No- 13 above but 3 HP
Taking out the pump from the motor and rewinding of 2 HP motor with super enamelled copper wire same gauge & size includinng all insulating material ie. sleeves stick and insulation sheet. and replacement of the following parts. (a) Replacement of driving and non driving end ball bearing-02 Nos. (b) Balanceing of rotor including straightening of strip -02 Job. (c) Replacement of bearing bush upper and lower-02 Nos.
All as per item No- 15 above but 3 HP
Repair/maintenance, and servicing of Pressure Switch including removing, cleaning, greasing, checking for wear and tear, refixing, testing, installing, commissioning as directed by Engineer-In-Charge Pressure Rating :- 0 – 10 Kg/sq.cm.
Repair/maintenance, and servicing of Solenoid Valve 15 mm dia 230 V AC, including removing, cleaning, greasing, checking for wear and tear, refixing, testing, installing, commissioning as directed by Engineer-In-Charge.
Repair/maintenance, and servicing of Solenoid Valve 20 mm dia 230 V AC, including removing, cleaning, greasing, checking for wear and tear, refixing, testing, installing, commissioning as directed by Engineer-In-Charge.
Repair/maintenance, and servicing of float type point level sensor 230 V AC, including removing, cleaning, greasing, checking for wear and tear, refixing, testing, installing, commissioning as directed by Engineer-In-Charge.
Repair/maintenance, and servicing of Motorised Butterfly Valve - Size 200mm including removing, cleaning, greasing, checking for wear and tear, refixing, testing, and commissioning complete all as specified and as directed.
Repair/maintenance, and servicing of Motorised Butterfly Valve - Size 150mm including removing, cleaning, greasing, checking for wear and tear, refixing, testing, and commissioning complete all as specified and as directed.
Repair/maintenance, and servicing of Motorised Butterfly Valve - Size 100mm including removing, cleaning, greasing, checking for wear and tear, refixing, testing, and commissioning complete all as specified and as directed.
Repair/maintenance, and servicing excluding spares but including regular maintenance of the PLC and Relay Logic based control panels installed at Airforce Station Tughlakabad including carrying out complete maintenance/serving/repairs as required of all the sub systems viz. PLC based control panels (with all the accessories) , breakdown maintenance and replacement of unserviceable parts, refixing of old serviceable parts / new parts if any including the followings and all as specified and directed by Engineer-in-Charge:- Equipments:- (i) Automation Panel at Vayusenabad Booster Pump House (ii) Automation Panel at Tech Booster Pump House Notes:- (i) The scope of work includes the charges required for removing, repairing, refixing, carrying out electrical termination and fixing/installing, testing, commissioning, etc and all as directed. (ii) New parts if any shall be paid under separate items as supply only. (iii) In addition to above specific emergency complaints from time to time shall be attended after receiving the same. Note:- The already installed Automation Panel is installed and programmed by M/S Universal Switch Gear Control. It is Commanded that the updating of Automation system should be done through OEM(i.e. M/S Universal Switch Gear Control ) or through the authorized service provider of the OEM or through other OEM of M/s Schneider Electric/ABB/GE Automation.The tenderer has to submit of MOU within seven days of acceptance of tender to the Garrison Engineer, failing which the contract will be liable to be cancelled and work shall be excuted at risk & cost of the contractor.
Supply, installation, testing, and commissioning in replacement of float type point level sensor for Over Head tank with the following specification:- Type:- Magnetic Magnet:- Ring Type Switch:- Reed Switch Connecting cable:- 2 core Teflon Make : Siemens / Nohken / Universal
Supply, Installation, Testing and Commissioning in replacement of Flow Switch along with all necessary installation accessories like GI barrel piece, double nipple etc with following specification :- Type:- Pedal Designed Line Pressure:- 150 PSIG Make: Switzer / Siemens / Rapid Control
Supply, installation, testing, and commissioning in replacement of Pressure Transmitter with proper wiring including necessary power pack for supply of DC :- Power supply: 10-36 V DC Enclosure: whether proof IP 65 Process temperature: -30 to 120 Celsius Accuracy: 0.25 % Make: Indfos/Danfoss/ Endress+Hauser
Supply and fix in replacement Electric motor suitable for actuator for 100mm dia. Motorized Butterfly valve (20 Kg/N to 30 Kg/N) complete all as specified and as directed. Make Cat No. UNIVERSAL (U-100/10/220VAC) / EMERSON/ROTORK.
Supply and fix in replacement Electric motor suitable for actuator for 200mm dia. Motorized Butterfly valve (20 Kg/N to 30 Kg/N) complete all as specified and as directed. Make Cat No. UNIVERSAL (U-200/10/220VAC) / EMERSON/ROTORK.
Supply and fix in replacement Printed Circuit Board (PCB) for Motorized Butterfly valve of size 100,150,200 mm complete all as specified and as directed. Make Cat No. UNIVERSAL (U-100,150,200/10/220VAC) / EMERSON/ROTORK.
Supply, Installation, testing and Commissioning in replacement of 80 mm dia, single phase, Motor Actuated Butterfly valve with disc material of CI with nylon coating, hand wheel for manual operation and having 02 nos. limit switches for Open / Close condition and valve position indicatorin replacement.The mounting shall be direct on valve type. Input Voltage: 230 V, A.C. Designed line pressure: 16 kg/sq cm. In built Serial / USB communication Port In built data logger with memory In built SD Card In built bluetooth transceiver with capability of pairing with any android based smart phone to download logged data. The mounting shall be indirect type using specialized extended type arrangement of GI pipe of suitable size/thickness, so that actuator mounting is at least 36 inches above ground level complete all as specified and directed. Make : ZOLOTO/UNIVERSAL (U-80/16/220VAC) /VAT/EMERSON
All as per item No 31 herein before but for 150mm dia.
Supply & fix in replacement of 4 Core 1.5sq.mm. PVC sheathed PVC insulated copper armoured cable complete all as specified and directed by Engr-in-charge. Make: Havells/Polycab/Gloster
All as per item No 33 herein before but for 6 Core 1.5 Sqmm.
Dismantling of old existing panel board including disconnecting of main feeder, sub feeder bus bars & removing from site.
S&F in repair Cast iron foot valve of size 150mm dia with necessary fixing arrangement like nut , bolts washer packing sheet etc including taking out existing unserviceable footvalve complete all as directed at site. Make:- Kirloskar/Sant/Zoloto
All as per item No 38 herein before but for 100mm dia.
All as per item No 38 herein before but for 65 mm dia.
S&F in repair Cast iron non return valve of size 150mm dia ISI Marked both end flanged with necessary fixing arrangement like nut , bolts washer packing sheet etc including taking out existing unserviceable valve complete all as directed at site. Make:- Kirloskar/Sant/Zoloto
All as per item No 41 herein before but for 100mm dia.
All as per item No 41 herein before but for 65 mm dia.
M & L for preparation of old Cast iron/ GI steel water tubing including all fittings and Sluice valves and applying two coats of synthetic Enamel paint (Colour as decided by Engineer -in- Charge) on suction,delivery of pump Sets, pipe lines of dia not more than 200mm complete all as specified and directed by Engineer-in-charge.
S&F in repair new Leather Sheet flap with Cast iron plate of foot valve of size 100mm dia with necessary fixing arrangement like nut , bolts washer packing sheet etc including taking out existing defective foot valve from UG sump complete all as directed at site.
All as per item No 45 herein before but for 150mm dia.
Supply and fix in repair rubber coupling suitable for 7.5/10/12.5 HP pump set as per existing pattern complete all as specified and directed by Engr-in-Charge.
All as per item No 47 herein before but for 40/60 HP.
Re-development of bore well by means of DTH compressor of suitable capacity & Pressure (Minimum 2 hour each bore well) with Air compressed in deep bore well with high pressure rubber hose in bore well ( Each upto 200 Meter deep) by pushing compressed air pumping muddy water till the clear water is obtained all as directed.
S&F in replacement GI column pipe of size 40 mm dia including welded flange nut bolts, washer, gasket and welding works complete all as specified and directed by Engr-in-Charge. Make-Jindal/Tata/Electrosteel
All as per item No 50 herein before but for size 50mm dia.
S&F in replacement of gate valve of size 50 mm dia complete all as specified and directed by Engr-in-charge. Make-Sant, Zoloto
S&F in replacement Fully Automatic star delta motor starter upto 40 hp ,with single phase protection AC-3, 415V,50 Hz, 3 Phase , relay range 30 to 50 AMP complete all as specified and directed by Engr-in-charge. Make- L&T/Havells Cat Part No IHPASDWE or equivalent ISI marked.
S&F in replacement Direct on line Submersible pump starter of capaccity 3 HP( 3.7 KW) current rating 18 Amp overload relay range 9-13 Amp.Make- Havells Cart part No IHSDOAKB*A/L&T or equivalent ISI marked.
S&F in replacement Direct on line Submersible pump starter of capaccity 10 HP ( 7.5 KW) current rating 25 Amp overload relay range 17-25 Amp.Make- Havells Cat part No IHSDOAPC*A/L&T or equivalent ISI marked.
S&F in replacement Auto phase sequence corrector (Motor protection Assembly) suitable for 05 HP to 12.5 HP capacity pump and motor, with five protection 415 volt ,3 phase 50 Hz supply complete all as specified and directed by Engr-in-charge. Make- L&T, Universal Switch Gear
M&L for Single phase preventor VSP 2 auto/manual reset of any size , 415V, complete all as specified and directed by Engr-in-charge. make-AE/L&T/SG/Minilec.
M&L for Power contactor 3 pole Type CN5 50 AC 50 Amp rating complete all as specified and directed by Engr-in-charge. Make- Havells Cat part No IHPAA050511, L&T or equivalent ISI marked.
M&L for Power contactor 3 pole Type MNX 70 AC 3 rating 70A complete all as specified and directed by Engr-in-charge. Make- Havells, L&T Cat part No CS97076 or equivalent ISI marked.
M&L for Power contactor 3 pole Type CN6 95 AC 3 rating 95A complete all as specified and directed by Engr-in-charge. Make- Havells Cat part No IHPAA095611, L&T or equivalent ISI marked.
M&L for Power contactor 3 pole Type CH1,150 AC 3 rating 150A complete all as specified and directed by Engr-in-charge. Make- Havells Cat part No IHPAA150100, L&T or equivalent ISI marked.
M&L for Power contactor 3 pole Type MNX 32 AC 3 rating 32A complete all as specified and directed by Engr-in-charge. Make- Havells L&T cat Part no CS94111
Supply & fix contactor, 3 pole, 415V, MNX 25 complete all as specified and directed by Engr-in-charge. Make- L&T Cat part No CS94110, Havells or equivalent ISI marked.
Supply & fix Power contactor 3 pole Type 4 ML AC 3 rating 70 A with auxilary contact 2 NO + 2 NC complete all as specified and directed by Engr-in-charge. Make- L&T cat part no SS90910 or equivalent ISI marked.
Supply & fix Power contactor 3 pole Type 3 ML AC 3 rating 40 A with auxilary contact 2 NO + 2 NC complete all as specified and directed by Engr-in-charge. Make- L&T cat part no SS90721 or equivalent ISI marked.
Supply & fix Power contactor 3 pole Type 2 ML AC 3 rating 32 A with auxilary contact 2 NO + 2 NC complete all as specified and directed by Engr-in-charge. Make- L&T cat part no SS90701 or equivalent ISI marked.
Supply & fix Power contactor 3 pole Type 1.5 ML AC 3 rating 25A with auxilary contact 2 NO + 2 NC complete all as specified and directed by Engr-in-charge. Make- L&T cat part No SS91851 or equivalent ISI marked.
Supply & fix Electronic overload relay (Manual reset) relay range 24-40 amp suitable for direct mountimg complete all as specified and directed by Engr-in-charge. Make- L&T Cat part No SS9597900G0 or equivalent ISI marked.
Supply & fix Electronic overload relay (Manual reset) relay range 9-16 amp suitable for direct mountimg complete all as specified and directed by Engr-in-charge. Make- L&T Cat part No SS9597900A0 or equivalent ISI marked.
Supply & fix Electronic overload relay (Manual reset) relay range 45-75amp suitable for direct mountimg complete all as specified and directed by Engr-in-charge. Make- L&T or equivalent ISI marked.
Supply & fix Electronic overload relay (Manual reset) relay range 66-110 amp suitable for direct mountimg complete all as specified and directed by Engr-in-charge. Make- L&T or equivalent ISI marked.
Supply & fix Electronic timer 415 Volt, 50 Hz range 3-10 Secs complete all as specified and directed by Engr-in-charge. Make- L&T or equivalent ISI marked.
S&F in replacement Submersible cable PVC insulated copper conductor flat 3 core 2.5sqmm 1100 volt complete all as specified and directed by Engr-in-charge. Make- Havells or equivalent ISI Marked.
All as per item No 73 herein before but for 3 core 4 sqmm.
All as per item No 73 herein before but for 3 core 6 sqmm.
Supply only copper lugs size varying from 6 sq mm to 35 sqmm for jointing cable. All as specified and directed by Engr-in-Charge. Make- Dowells Cat Part No CUS-554 & equivalent
M&L in replacement for MCCB 3 pole 63 amps, 25 KA complete all as specified and directed by Engr-in-charge. make- Legrand or equivelent of Havells Cat Part No IHLGHT0063 / L&T/Standard.
M&L in replacement for MCCB 3 pole 100 amps, 25 KA complete all as specified and directed by Engr-in-charge. make- Legrand or equivelent of Havells Cat part No IHLGHT0100#/L&T/ Standard.
M&L in replacement for MCCB 4 pole 100 amps, 35 KA complete all as specified and directed by Engr-in-charge. make- Legrand or equivelent of Havells Cat part No IHLFNF0100# / L&T/Standard.
M&L in replacement for MCCB 3 pole 200 amps, 35 KA complete all as specified and directed by Engr-in-charge. make- Legrand or equivelent of Havells Cat Part No IHLFNF0200# / L&T/Standard.
M&L in replacement for MCCB 4 pole 250 amps, 50 KA complete all as specified and directed by Engr-in-charge. make- Legrand or equivelent of Havells cat Part No IHLFHF0250# / L&T/Standard.
M&L in replacement for MCCB 4 pole 400 amps,50 KA complete all as specified and directed by Engr-in-charge. make- Legrand or equivelent of Havells Cat Part No IHLLNFBF0400 / L&T/Standard.
M&L for making Pump set foundation from PCC 1:3:6, type C1, with 20mm graded stone aggregate,of any shape or size as indicated including grouting of foundation bolts of suitable dia and size as required on site complete all as specified and directed at site by EIC.
M&L for cutting of existing CI pipe line in position for rectifying leakage and reducing to required length, in position, for insertion of collars or other fittings including necessory exvation and earthwork, dewatering etc,if any involed, complete all as specified and directed for 80mm bore of pipes Note : S&F of insertion of fittings/pipes pieces etc shall be measured & paid for separately under appropriate item of Sch 'A').
ditto but for 100m bore pipe
ditto but for 150m bore pipe
Taking down Old unserviceable cast iron detachable joints of any size,any description and in any postion from existing pipe lines complete all as specified and directed.
S & F cast iron detachable joint for 80mm bore of pipes for coupling of CI/GI pipe including nuts, bolts and rubber ring etc for short collar/long collar as per sire requirement complete all as specified and directed.
ditto but for 100m bore pipe
ditto but for 150m bore pipe
Repairing of Auto phase sequence corrector (Motor protection Assembly) of 7.5 HP to 40 HP capacity, current rated capacity upto 200A, 415 volt ,3 phase 50 Hz supply incl removing, replace of internal wiring, refixing, testing, installing and commissioning Complete all as specified and as directed by Engr-in-Charge.
Repairing of automatic star delta starter ML 4/ML3 for pump and motor, 415 volt ,3 phase, incl removing, replace of internal wiring, refixing, testing, installing and commissioning Complete all as specified and as directed by Engr-in-Charge.
Repairing of Battery charger capacity of 02 Amp, 230 volt supply incl replace/repair of rectifier circuit, power circuit, regulator circuit, control circiut, fault detection circuit, internal wiring, refixing & testing Complete all as specified and as directed by Engr-in-Charge.
S&F MS clamp with nuts and bolts for 50mm dia column pipe made out of 12mm thick MS flat of size 600mm long and 50mm wide, fabricated to shape, fixed at the top of the tube well complete all as specified and directed by the Engr-in-Charge.
S&F well cap for 200 mm dia internal threaded and welded iron handle, fabricated from 6.00 mm thick MS sheet complete all as specified and directed by Engineer -in- Charge.
Excavation in trenches not exceeting 1.5 Mtr wide and not Exceding 1.5 Mtr in depth and getting out in Hard/Dense soil for laying cables all as directed.
Returning, filling in including spreading, levelling, watering and ramming in layers not exc. 25 cms.
Removing excavated material not exceeding 50 Mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point all as directed.
Supply and fill dry river sand in trenches for cable cushioning complete all as specified and directed.
Supply and fix bricks subclass B designation 75, laid flat in trenches for protection of cable over LT cable complete all as specified and directed.
S&F in replacement of XLPE insulated heavy duty electric cable with aluminium conductor, 1100 volt grade, cross-sectional area size 3.5 C 35 Sqmm complete all as specified and directed by Engr-in-Charge. Make:- Polycab/Plaza/Finolex
ditto but for 2 C 6 Sqmm.
Supply, installation, fixing, jointing and testing, ISI Marked, cast iron sluice valve of class PN-1 conforming to IS-14846 of 2000 both ends flanged with iron wheel head and stainless steel spindle, long body type, jointed on both ends with and including rubber gasket joints, nut, bolts & washers and tested complete all as specified and directed for 80mm bores complete all as specified and directed by Engr-in-Charge.
ditto but for 100m bore pipe
ditto but for 150m bore pipe
Supply and fix in repair/replacement dosing pump, single phase, 230 Volts, Max flow rate 4LPH, injection pressure 5.5 kg/cm2 or equivalent specifiction & incl connceted accessories complete all as specified and directed by Engr in charge. Make : Eureka Forbes/Milton roy/Ramco OR EQUIVALENT AS APPROVED BY GE
S & F in repairs indicator lamps suitable for 3 phase LT panel board/as per samplecomplete all as specified and directed by Engr-in-Charge.
S & F in repairs volts meter 0 to 500V Square type 96mmx96mm complete as specified and directed. Make: L&T/Havells/BCH.
Supply & fix in repair Onload changeover Switch four pole by pass switch conforming to IS: 13947 Part III in sheet steel enclosure of rated current capacity 200 A complete as specified and directed. Make : HAVELLS Cat part No IHCBF00200 or equivalent Make of Indoasian/L &T
Supply only AQUAFIT( Calcium hypochlorite) disinfect for water treatment more stable than bleaching powder and sodium hypochlorite.Make- Aquafix/Altoch/ Hi Strength Hypo LTD or equivalent ISI marked approved by E-in-Cs Branch.
S&F pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/clading to wall, fixed with self tapping screws and bending of sheet as required and as directed by Engineer-in-Charge.
M&L for channel MS angle iron (60x60mm), MS channel(100x50x50mm) and ensuring the allignment of pump and motor complete with bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washer, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint all as specified and directed by Engr-in-Charge
M/S S.K.Electricals
Surjit and Sons
G M CONSTRUCTION COMPANY
Flint India
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .