| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.6 LAccepted-AOC 9 EZRA STREET KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | L1 | Accepted-AOC Quoted lowest and reasonable | |
| 2 | L2₹59.7 L+₹10.1 L (20.4%)Rejected-Finance | L2 | Rejected-Finance Quoted high rate | |
| 3 | L3₹61.7 L+₹12.1 L (24.5%)Rejected-Finance 33 CHANDASI HOUSE LANE NO 11 S K PURAM ARYA SAMAJ MANDIR ROAD RPS MORE BAILEY ROAD DANAPUR PATNA BIHAR 801503 | PATNA | PATNA | BIHAR | 801503 | L3 | Rejected-Finance Quoted high rate | |
| 4 | L4₹72.9 L+₹23.3 L (47.1%)Rejected-Finance 1 TROPICAL REFRIGERATION PHONIX BAY PORT BLAIR PORT BLAIR ANDAMAN NICOBAR 744101 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L4 | Rejected-Finance Quoted high rate | |
| 5 | L5₹78.1 L+₹28.5 L (57.6%)Rejected-Finance GROUND FLOOR HOTEL SHALIMAR DELANJPUR SRI VIJAYA PURAM 744 102 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744102 | L5 | Rejected-Finance Quoted high rate |
Tender Value
₹68.5 L
EMD Value
₹1.3 L
Closing Date
22 Apr 2025, 6:00 pmClosed
Col Alex Antony, CWE Sri Vijaya Puram
Commander Works Engineer, Military Engineer Services, Minniebay, Junglighat PO, Sri Vijaya Puram- 744 103
SPECIAL REPAIR FOR REPLACEMENT OF OLD VINTAGE FOUR POLE/ TWO POLE STRUCTURES WITH SF6 BASED RING MAIN UNITS AT INHS DHANVANTARI UNDER GE MINNIEBAY SRI VIJAYA PURAM
2025_MES_702495_1
81143 SPECIAL REPAIR FOR REPLACEMENT OF OLD VINTAGE FOUR POLE/ TWO POLE STRUCTURES WITH SF6 BASED RI
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Sri Vijaya Puram
As per NIT
8 documents required · 8 mandatory
₹1,000
GE Minniebay
₹1.3 L
Yes
29 Jul 2025
25 Mar 2025
29 Apr 2025
25 Mar 2025
22 Apr 2025
15 Apr 2025
Amount
Taking down/dismantling old vintage HT four pole structure and connected fitting fixture complete with necessary T&P complete all as specified and as directed.
Taking down/dismantling old vintage HT two pole structure and connected fitting fixture complete with necessary T&P complete all as specified and as directed.
Supplying, Installing, testing & commissioning of Factory Made, Floor mounted, 11 kV, 630 Amps, 21 kA for 3 Seconds, SF6 Insulated, Motorised, Outdoor, extensible type, 8 Way RMU Consisting of 2 Nos. VCBs as Incoming and 6 Nos. of VCBs as Outgoing with metering cubicle and SCADA Compatible complete all specified and as directed and shall comprise of the following: Make of RMU/ VCB/ Vacuum Interrupter/ Relays : ABB/ SIEMENS/ SCHNEIDER [A] RMU shall be floor mounted, 11 KV, 630 Amps, 21 kA for 3 Seconds, SF6 Insulated, Motorized, Outdoor extensible type, RMU with Air Insulated Bus Connected Metering unit, Type tested in line with latest IEC Standards, suitable for operations at a height up to altitude 1000 Meters above sea level and Ambient Temperature range from 5ºC to 50ºC as per OEM designed de-rating, Switchgear and Busbar shall all be contained in a Stainless Steel Enclosure [Minimum 2.0mm thick SS 304 Grade filled with SF6 at 0.3 Bar [300 hPa] Relative Pressure, RMU Tank shall provide Full Insulation and Switchgear shall be insensitive to the environment with Degree of Protection of IP67, Switchgear Operating Mechanism shall have an IP2X Protection and Cable Chamber shall have IP3X Protection, Outer Enclosure shall be IP 54 type tested, Powder Coated with Pure Polyester Based Paint, suitable for the site installation conditions, Accidental Overpressure due to an Internal Arc is limited by the opening of the safety valve, at the bottom of the metal enclosure, away from the operator, Plug in type of extensibility must be provided and coupling busbar should not be exposed to air to avoid oxidation of busbars.
[B] Each Vacuum Circuit Breaker [VCB] shall be comprising of the following: [i] 11 KV, 630 Amps, 21 kA/ 3s, 3 Pole Motorised VCB (Non draw out type) with 3 pole manual disconnector and 3 pole manual earth switch, Motorized Spring Assisted Mechanism and Series Trip Coil – 1 No. [ii] Self Powered Relay with O/C, S/C, E/F Protection. Relay shall have a Front USB for Laptop Interface, LCD Display, 10 Event Records, 5 Fault Records, min 2 setting group and keypad for setting parameters for the relay – 1 No [iii] Resin Cast ring core Protection CT, Plate mounted type : 200-100/1A, 5P10, 2.5 VA-01 Set. [iv] Resin Cast ring core Metering CT, Plate mounted type : 200-100/1A, Cl. 1.0, 2.5 VA-01 Set. [iv] Live Cable Indicator with indications at the Front and Three Inlets to check the Synchronization of Phases – 1 No or as per OEM design [v] Making capacity - 52.5 kAp [vi] Cable Termination Bushing suitable for up to 1 Run, 3 Core, 185 Sq.mm, XLPE Cable – 1 Set [vii] Cable Termination Cover Boots [Push on type] – 1 Set.
[viii] Circuit Breakers shall have Two Positions: Open or Disconnected and Closed. A separate and independent 3 Position Earthing Switch and disconnector shall be fitted to open and earth the cables in such way that interlocks prevent all unauthorised operations. An operating mechanism shall be used to manually close the circuit breaker and charge the mechanism in a single movement. An independent mechanism shall be fitted for the 3 Positions Earthing Switch and Disconnector Circuit breaker shall be fitted with a local system for manual tripping by an Integrated Push Button. There shall be no automatic reclosing. Circuit Breaker shall have a min of 2000 Mechanical and Electrical Operations and 50 Nos Short Circuit Operations, Disconnector and Earth Switch shall have a minimum of 1000 [M1] Mechanical Operations , 100 Electrical Operations at rated current. [C] Air Insulated Bus Connected Metering Unit comprising the following: – 1 Set [i] Air Insulated Enclosure with necessary Bus Connection – 1 No [ii] PT 11KV / √3 / 110V / √3, 50 VA, Class-1.0 – 1 Set [iii] Multi Function Meter, Digital Type [Displaying A, V, PF, Hz, KVA, KW, KVAR, KWH, KVARH etc. Class 1.0 / 0.5] with RS485 Port for Communication in Modbus Protocol. - 01 Set [iv] R / Y / B Indicating Lamps – 1 Set [v] Provn of control wiring with DWC/CPVC protection pipe from nearest substation LT panel or RMU [vi] Battery and Battery Charger, 12 Ah, [I/P-230V AC, O/P - 24V DC] – 1 No or as per OEM design. [D] Space Heater with thermostat
[E] 2 x 8 or as per OEM design Window Alarm Annunciator and Hooter. Notes: [a] The IAC in front, lateral and rear AFLR 21 kA – 1 Sec, Downwards Exhaust, for Tank as well as Cable Compartment of the RMU Switch board during an internal fault shall not be exposed to the effects of Arcing. Internal Arc Type Test Report for IAC AFLR 21 kA for 1 Sec for both Tank & Cable Box. [b] All operations shall be from front of the RMU, including access to cable bushings. Bushings along the sides or the rear of the RMU are not acceptable. [c] The quoted rate is deemed to be inclusive of, to provide minimum 04 No operating handles for operation of RMU. [c] Construction of Plinth / Foundation for 11KV RMU: The rate quoted is deemed to be including the cost of Plinth / Foundation and shall not be paid as extra on this account. The foundation shall consists of Two Parallel solid block masonry straight or curved on plan to any radius built in Cement Mortar 1:6 of suitable length, suitable thickness and height as per the manufacturer’s instructions over PCC Concrete Bed of 150mm thick in PCC 1:4:8, Type D-2, using 40mm graded stone aggregate over 150mm thick Hardcore of gauge not exceeding 63mm of broken stones or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick watered and rolled, over 150mm thick Sand Bed, rendering to brick surfaces, 15 mm thick in Cement Mortar 1:4, and finishing the top surface even and smooth without using extra cement, applying Three coats of white washing including earthwork excavation complete all as per manufacturer’s recommendations, drawings, as specified and as directed.
[d] The rate quoted is also deemed to be including the cost of disconnection of HT Cables up to 3 Core, 185 Sq.mm from existing 2 Pole / 4 Pole Structures, removing of cable loop and reconnection to RMU complete all as specified and as directed by the Engineer-in-Charge. [e] End termination joints and Shifting/ relaying of cable from structure to RMU shall be measured and paid separately. [f] The make of RMU/ VCB/ vacuum interrupter/ Relays offered shall be of same make/ OEM approved makes. (g) The Contractor shall submit GA drawings of RMU for approval of GE before placing order. The Contractor shall make all necessary arrangements for pre-despatch inspection at manufacturer site or e-testing as directed by Accepting Officer and for pre-commissioning test by SEI/EI/ ESO or any testing officer as nominated by HQ CE (A&N) Zone through Accepting Officer after installation of RMU. The cost for the same is deemed to be included in quoted rate.
M & L for shifting/ Relaying of HT UG cable of sizes 95 Sqmm to 120 Sqmm from structure to RMU complete all as specified and as directed Note: necessary excavation earthwork shall be measured and paid seperately.
Supply, laying in trenches/ ducts, fixed on walls, passing through pipes, testing & termination of HT UG cable, XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor 11 KV (earthed) grade cable of following sizes including taking down defective cable complete all as specified and as directed. Note:- (i) HT end termination kits/ straight through joints will be measured and paid separately. (iI) Excavation earth work shall be measured and paid seperately.
3 Core 120 Sqmm
3 Core 95 Sqmm
Excavating in trenches n. exc. 1.5m wide and n. exc. 1.5m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. n. exc. 10sq.m. on plan and n. exc. 1.5m in depth and getting out in soft / loose soil complete all as specified and as directed.
Returning, filling in including spreading leveling watering and well ramming in layers not exc 25cm in any type of soil complete all as specified and as directed.
Removing excavated materials to a distance not exc. 50m and depositing where directed at a level n.exc 1.50m above the starting point complete all as specified and as directed.
M&L for river sand filling in trenches spreading and levelling in layers n. exc 25cm thick and well ramming including watering as required complete all as specified and as directed.
Supply & Laying reinforced precast concrete cable cover, class HV, type 2 with flat, size 450mm x 180mm x 40mm complete all as specified and as directed.
Supply and lay 80 mm dia GI tubes light grade galvanised with all fittings laid in trenches etc for protection of cable including taking down of old unserviceable GI pipe of complete all as specified and as directed.
Supply & fix cable jointing kit for 11 KV grade XLPE cable for Indoor end termination cold shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 50 Sqmm to 95 sqmm, testing after jointing including taking down defective end joint complete all as specified and as directed.
Supply & fix cable jointing kit for 11 KV grade XLPE cable for Indoor end termination cold shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 120 Sqmm to 185 sqmm, testing after jointing including taking down defective end joint complete all as specified and as directed.
Supply and fix cable jointing kit for 11 KV grade XLPE cable for straight through joint, cold shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE , armoured, Al conductor cable of size 50 sqmm to 95 sqmm, testing after jointing including taking down defective end joint complete all as specified and as directed.
Supply and fix cable jointing kit for 11 KV grade XLPE cable for straight through joint, cold shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE , armoured, Al conductor cable of size 120 sqmm to 185 sqmm, testing after jointing including taking down defective end joint complete all as specified and as directed.
Material and labour for earthing with galvanised earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly in ground vertically to a depth of not less than 2.25 mtr below ground level connected to galvanised iron strip 32 mm x 6 mm by means of GI Welding made out of galvanised iron mild steel and 40 mm dia GI pipe "light grade" for protection of earth lead, 20 mm dia GI pipe for watering and earth plate surrounded by packed layer of coal and common salt, 15cm thick all around bottom and top, watering pipe of 20 mm bore of light grade with funnel all as shown in electrical plate No 3 of SSR Part-I (2009) and connecting to earthing test point, main switch board/ transformer neutral/ RMU and testing on completion as directed including earthing pit in PCC (1:3:6) type C-1, pre-cast reinforced cover with MS XPM Jalli, RCC 1:1.5:3 cover slab of size 300 x 300 x 100 mm with one handle made out of 8 mm dia round bar, wire mesh and testing complete all as specified and as directed including dismantling old defective earth pit. Note: (i) Cost of GI earth Strip and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item. (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, returning & filling, PCC chamber pit, RCC cover & test point.
Energy Water Supply (BID ID -3285883)
Roy and Sons Infrastructures (BID ID -3286131)
Tropical Refrigeration (BID ID -3286114)
M/S AMBER PAVER PRODUCTS (BID ID -3285989)
SKV Engineering (BID ID -3285949)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .