Loading…
Loading…
Tender Value
₹15.8 L
EMD Value
₹31,617
Closing Date
1 Oct 2026, 3:00 pm4d left
The Registrar
The Registrar Central University of Tamil Nadu
Providing False Ceiling Academic Building-IV, Microbiology Dept, Rooms KS-302 to309, CUTN,Thiruvarur
2026_CUTN_925726_1
CUTN/ENGG/CVL/Ten/2026-27/10
Open Tender
Civil Works
Works
Central University of Tamil Nadu Thiruvarur
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹31,617
Estate Section
10 Sept 2026
10 Sept 2026
5 Oct 2026
10 Sept 2026
1 Oct 2026
10 Sept 2026
21 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Providing and fixing false ceiling at all heights with integral densifiedcalcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design and patternsas per CPWD Specification 2019, to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanisediron section of0.33mmthick (galvanized @ 120 grams per sqm including both sides)comprising of main-T runners of size 24x38mm of length 3000 mm,cross - T of size 24x32 mm of length 1200 mm and secondary intermediate cross-T of size 24x32 mmof length 600mm to formgrid module of size 600 x 600 mm,suspended from ceiling usinggalvanised mild steel items (galvanizing@ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm diafully threaded hanger rod upto 1000 mm length and L-shape leveladjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size25x37x25x1.6mm thick with precut hole on both 25mm flange topierce into 12x50mm or even bigger size dash fastener if require, fixed with Glavanised iron perimeter wall angle or size 24x24x0.40mm of length 3000 mm to be fixed onperiphey wall / partition withthe help of plastic rawl plugs at 450mm center to center and 40 mmlong dry wall S.S screws. The workshallbe carried out as per specifications, drawing and as per directionsof the Engineer-in-Charge. | |||||
| 1.1 | With 15 mm thick tegular/butt edged without perforationplain/designer light weight calcium silicate Anti-MicrobialBio-Safe coated false ceiling tiles Confirming to JIS-Z2801and ASTM G-21 | 390 | Sq.m | 53 | ₹20,670 |
| 2Electrical works - Wiring | |||||
| 3Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. | |||||
| 3.1 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire (Computer ) | 160 | per mtr | 53 | ₹8,480 |
| 4LED Panel light 2x2 ft., (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends ,CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). | |||||
| 4.1 | 40 watt | 105 | Nos | 53 | ₹5,565 |
| 5 | Dismantling & Reinstallation of existing Air Conditioners, testing & Commissioning Air conditioners including supply & fixing of necessary copper pipe (upto 5 meters ) as required and directed by Engineer In charge | 6 | Nos | 53 | ₹318 |
| 6 | Refilling of R32/R415 refrigerant gases | 6 | 1.5 Kg each | 10 | ₹60 |
| 7 | Supply and fixing of extra length of Twin Copper pipe line duty insulated by suitable thickness nitrile rubber along with PVC insulated copper conducted (for control & power cabling) suitable for 2.0 TR Split Air-Conditioner from Indoor to units to Outdoor Unit in suitable size PVC flexible pipe for protection of piping, on the wall surface/Cable tray etc using suitable clamps etc complete as per site requirement | 30 | Mtr | 1.25 | ₹37.5 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.77 MB
TenderFalseceiling.pdf
Tender Documents • 1.75 MB
BOQ_972799.xls
BOQ • 0.41 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .