| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.0 CrAccepted-AOC | ₹6.0 Cr | L1 | Accepted-AOC Accepted being L1 |
| 2 | L2₹6.5 Cr+₹45.1 L (7.46%)Rejected-Finance 11 GURU NANAK MARKET AMBALA ROAD SAHARANPUR 247001 | SAHARANPUR | UTTAR PRADESH | 247001 | ₹6.5 Cr+₹45.1 L (7.46%) | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹6.9 Cr+₹83.2 L (13.8%)Rejected-Finance NO 15 B 2ND FLOOR 4TH CROSS T ASHWATHNARAYANA ROAD THIMMAIAH NAGARA YELAHANKA BANGALORE 560 064 | BANGALORE | BANGALORE | KARNATAKA | 560064 | ₹6.9 Cr+₹83.2 L (13.8%) | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹7.3 Cr+₹1.2 Cr (20.0%)Rejected-Finance 20 1ST A CROSS SAI NAGAR AREHLLI UTTARHALLI BANGALORE 560 061 | BENGALURU URBAN | KARNATAKA | 560061 | ₹7.3 Cr+₹1.2 Cr (20.0%) | L4 | Rejected-Finance Not being L1 |
| 5 | L5₹7.5 Cr+₹1.5 Cr (24.7%)Rejected-Finance | ₹7.5 Cr+₹1.5 Cr (24.7%) | L5 | Rejected-Finance Not being L1 |
Tender Value
₹8.1 Cr
EMD Value
₹7.3 L
Closing Date
12 Apr 2023, 6:00 pmClosed
Chief Engineer AF Bangalore
Chief Engineer AF Bangalore No. 2 DC Area MES Road Yeshwantpur Post Bangalore 560022
ADDN/ALTN/IMPROVEMENT TO CERTAIN ROOFS AT ATS BELGAVI PH-II
2023_MES_582139_1
801571/E8
Open Tender
Civil Works
Item Rate
540 days
BELGAVI
S Class Cat a i
8 documents required · 8 mandatory
₹3,000
GE (AF) SAMBRA
₹7.3 L
Yes
8 May 2023
21 Feb 2023
19 Apr 2023
21 Feb 2023
12 Apr 2023
5 Apr 2023
22 Feb 2023 - 28 Feb 2023
Amount
Dismantling of plain or corrugated steel sheeting any guage, thickness including nainital or similar pattern in roof covering complete all as specified and as directed.
Dismantling Asbestos cement (corrugated, semi-corrugated etc) sheets in roof coverings complete all as specified and as directed.
Dismantling of Mangalore pattern or similar tiles in roof coverings including ridges complete all as specified and as directed.
Taking down of Battens for tiles, shingles etc, of any size including tilting fillets spacing exceeding 15 cm complete all as specified and as directed.
Dismantling timber scantlings of size 40 sq cm and over in section and in any position in unframed work complete all as specified and as directed.
Dismantling timber scantlings of size 40 sq cm and over in section and in any position in framed work complete all as specified and as directed.
Dismantling posts or struts (wood, steel or R.C.C.) embedded in concrete, brickwork, masonry etc. in any section, including taking out embedded portion and making good disturbed ground complete all as specified and as directed.
Material and labour for providing plain cement concrete (1:3:6) type C1, using 20mm graded crushed stone aggregate as in bed blocks, similar blocks, etc., including necessary form work complete all as specified and as directed.
Dismantling of brickwork and stone / boulder masonry built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
Material and labour for brick work with sub-class 'B' bricks, straight or curved on plan exceeding 6m mean radius built in CM (1:6) complete all as specified and as directed
Material and labour for rendering 15 mm thick on stone masonary surfaces or fair face of brick work in CM (1:4) to be finished even & smooth complete all as specified and as directed.
Material and labour for rendering 10 mm thick on stone masonary surfaces or surface other than fair face of brick work in CM (1:6) to be finished even & smooth complete all as specified and as directed.
Material and labour for preparation of newly plastered surfaces of walls and applying two coats of acrylic distemper on walls over a coat of alkali-resistant primer over 3mm thick wall care putty (multipurpose mixer shall be used for uniform and proper mixing of putty and applied with putty sprayer and prepared the surface even and smooth by vaccum based sanding machine) complete all as specified and as directed by GE. Note: First coat of distempering shall be carried out all as specified in SSR part I and final coat of distempering on wall with acrylic distemper shall be carried with mechanical tools
Material and labour for preparation of newly plastered surfaces of walls and applying two coats of cement based paint over a coat of alkali-resistant priming paint complete all as specified and as directed. (Note: First coat of cement based paint on new surfaces of walls shall be carried out all as specified in SSR Part I and final coat of cement based paint shall be carried out through mechanical tools.)
Taking down existing tarfelting of any type complete all as specified and as directed.
Taking down cement plaster of any description, any position complete all as specified and as directed.
Material and labour for roughening surface of old concrete floor by picking, sweeping clean and washing down with water to remove dust and brushing with neat cement slurry @ 3Kg of cement per Sqm complete all as specified and as directed.
Material and labour for providing 50 mm thick PCC 1:2:4, type B1 (Using 20 mm graded crushed stone aggregate) as in floors and pavings padding concrete/levelling course complete finished even and smooth without using extra cement complete all as specified and as directed.
Material and labour for 10mm thick rendering in cement mortar (1:3) mixed with water proofing compound as per manufacturer instruction on concrete surface and making the surface even and smooth as in required slope for draining out the rain water complete all as specified and as directed. (Note: WPC shall be measured and paid separately under respective item.)
Material and labour for preparing RCC roof slab by removing dust, dirt and applying oil bond bituminous primer @ 0.2Kg/Sqm and providing APP modified water proofing membrane weighting not less than 4 Kg/Sqm reinforced with non woven polyester matt weighing not less than 160 gms/sqm including minimum 10cm side over laps and 15cm end lap torch sealed and bonded as per detailed procedure on note No. 6 of TD AFB/TD/260/06 sheet 1/1 and applying a coat of blown hot bitumen 95/15 over a membrane at 1.20 kgs/sqm all as per detailed specification and procedure after drying apply a coat of solar reflective bituminous aluminium paint over membrane at 0.10 kg/sqm all as specified and as directed. Note:- (i) The work shall be carried out only through manufacturer or their authorised applicator and a written guarantee for work shall be submitted by the manufacturer for the effectiveness of WPT and the bidders rate is deemed to be included in the rate quoted by them.
Supply only liquid water proofing compound (ISI Marked) all as specified.
Material and labour for preparation of external surface of walls, facia / drops of roof slabs, applying two coats of antifungal, weather proof paint over a coat of primer complete all as specified and as directed (Note: First coat of anti fungal weather proof paint on new surfaces of walls shall be carried out all as specified in SSR Part I and final coat of antifungal weather proof paint shall be carried out through mechanical tools.)
Material and labour for providing plain cement concrete 1:2:4, type B1 using 20 mm graded crushed stone aggregate as in parapets, copings, bed plates fillets, kerbs, water troughs and the like including necessary formwork weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.,) or insulation boards/slabs/blankets, any thickness including cover fillets and frame work complete all as specified and as directed.
Demolition of reinforced cement concrete as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work and RCC water tanks on roofs (including reinforcement cut as required to facilitate demolition) complete all as specified and as directed.
Separating, scraping and cleaning of reinforcement obtained from dismantling of RCC tanks, beam etc complete all as specified and as directed.
Material and labour for Mild Steel plates (plain or chequered) channel, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe 410 W (Gde-E-250) Quality - A including fixing with riveting, bolting or welding complete all as specified and as directed.
Supply and fix rolled mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy brackets framing (Beam, tee, angle, channel, or flat section) including distance pieces, cleats etc. of Fe 410-W (Gde E-250) quality - A complete all as specified and as directed.
Material and labour for Mild steel work for wind ties for roof including securing bolts including all necessary drilling, bolting or riveting etc., and similar work conforming to Fe-290 Gde E-165 etc., complete all as specified and as directed.
Material and labour for mild steel work in tubular vertical posts including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade st - 240 complete all as specified and as directed.
Material and labour for preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Material and labour for preparation of new steel surfaces of any description, not exceeding 10cm in width or girth, when unconnected with other painting or when painted in a different tint and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Supply and fix pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa and 150AZ as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and as directed. Note :- The length of self tapping screw may vary for wooden and steel truss and quoted rates are deemed to be included
Material and labour pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa and 150 AZ as in ridges, roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. Note :- The length of self tapping screw may vary for wooden and steel truss and quoted rates are deemed to be included.
Supply and fix Aluminium, Stainless Steel Roof Top Air Ventilators Continuously in motion with low noise and leak proof installation with following specifications upto height of 10M including necessary scaffolding as applicable and match the profile of sheet to be cut and make sure that there is no leakage from affected roof portion. Totally Aluminum Built Number of Vanes: 0.5 mm thickness, 38 Numbers Center Shaft: Stainless Steel Bearing: Self Lubricated - 2 Nos Rivets: Aluminum Pneumatic Rivets Turbine Doom Thickness: 1 mm, Turbine Outer Dia: 680 mm, Turbine Doom Dia: 380 mm, Turbine Rotor Dia: 655 mm, Turbine Throat Dia: 610 mm, Turbine Height: 360 mm, Turbine Weight: 3.750 Kgs complete all as specified and as directed.
Cutting the existing corrugated GI sheet or AC sheet or Mangalore tiles roofing upto 600 mm dia, upto 10M height including silica joints to the periphery making water proof complete all as specified and as directed.
Supply and fix 8-10mm thick Gypsum board in ceiling over and including powder coated aluminium snap grid frame work supported by hanger 2 to 4 mm dia GI (up to length as per site requirement) adjusting level fixed to roof slab/walls/wooden/steel members by means of ceiling cleats made out of GI flat 40x3mm size 60 cm long and expansion hold fasteners 12.5mm dia 40mm long complete all as specified for false ceiling fixed with screws as per manufacturer's instruction complete all as specified and as directed.
Material and labour for preparation of newly plastered surfaces / gypsum board surfaces as in ceiling and applying two coats of acrylic distemper over a coat of alkali-resistant priming paints complete all as specified and as directed
Supply, fixing and installation of acoustic tiles with regular edge of 15 mm thickness, visible surface of each tile to be 7 mm below the grid, visible surface is a batch painted glass tissue in white, back of the tile covered with glass tissue. Size 600x600x15mm, compatible with Gyproc make BOLT SLOT GRID or silhouette grid, web 35 mm with the following specification and details:- Manufacturing - Manufactured production unit ISO 14001 certified. Acoustics-Sound absorption(Alpha W) - 1 at 200 mm o.d.s Acoustics-Sound absorption Class - Class A at 200 mm o.d.s NRC - 0.95 NRC as per ASTM C 423 Fire Safety - Tested and classified as non combustible with reaction to fire classification class A2 s1 d0. Flexural tensile strength - Class C/3N Indoor Air quality - Complying with the regulation on VOC emissions, A level. Building Information Group (RTS) with the M1 label. Product Certified under GRIHA council of India for Green Ratings, IGBC Green Pro certified. Environmental Footprint - Environmental Product declaration (EPD) acc to international ISO 14025 & EN 15804 series of standards. Circularity - Minimum post-consumer recycled content 47%, Fully recyclable Humidity Resistance -Class C, relative humidity 95% and 30°C. Light Reflectance - 83% light reflectance. Accessibility - The tiles are easily demountable CE Marking - Ecophon ceiling systems are CE marked construction products covered by a Declaration of Performance (DOP). Make : Saint - Gobain Ecophon Advantage or equivalent as approved by GE.
Supply and installation of acoustic tiles on wall of size 1200 x 2700 mm with 40 mm natural square edge, (with standard fabric approved by the GE) & wrapped around in concealed system with grippers . Size 2700x1200x40mm, customizable as per design. Fabric inclusive from Response fabric brand - MARS COLLECTION or its equivalent approved by GE with the following specification and details:- Manufactured in production unit ISO 14001 certified. Acoustics-Sound absorption(Alpha W) - 1 at 43 mm o.d.s Acoustics-Sound absorption Class - Class A at 43 mm o.d.s Articulation class - 230 as per ASTM E1111, ASTM E1110 Indoor Air quality - Complying with the regulation on VOC emissions, A level. Building Information Group (RTS) with the M1 label. Product Certified under GRIHA council of India for Green Ratings, IGBC Green Pro certified, Comply with the REACH regulation which confirms that mineral wool is produced in conformity with the Note Q of EC No 1272/2008. Environmental Footprint - Environmental Product declaration (EPD) acc to international ISO 14025 & EN 15804 series of standards. Circularity - Minimum post-consumer recycled content 53%, Fully recyclable Fire Safety - Tested and classified as non combustible with reaction to fire classification class A2 s1 d0. Humidity Resistance -Class C, relative humidity 95% and 30°C. Light Reflectance - Akusto in white high light reflectance CE Marking - Ecophon ceiling systems CE marked construction products covered by a Declaration of Performance (DOP). Make : Saint-Gobain Ecophon Akusto™ Wall A Akutex FT or equivalent as approved by GE.
Supply, fix and installation of exposed grid system of size 1200x600x15mm with ceiling with low light reflection and good sound absorbing properties. Manufactured in production unit ISO 14001 certified with the following specification and details:- Acoustics-Sound absorption(Alpha W) - 0.95 at 200 mm o.d.s Acoustics-Sound absorption Class - Class A at 200 mm o.d.s NRC - 0.9 NRC as per ASTM C 423 Flexural tensile strength - Class C/3N Indoor Air quality - Complying with VOC emissions, A level. Certified by the Finnish Building Information Group (RTS) with the M1 label. Product Certified under GRIHA council of India for Green Ratings, IGBC Green Pro certified, Comply with the REACH regulation. Environmental Footprint - Environmental Product declaration (EPD) acc to international ISO 14025 & EN 15804 series of standards. Circularity - Minimum post-consumer recycled content 47%, Fully recyclable. Fire Safety - Tested and classified as non combustible with reaction to fire classification class A2 s1 d0. Humidity Resistance -Class C, relative humidity 95% and 30°C, according to EN 13964:2014 Light Reflectance - 3-4% light reflectance. Accessibility - The tiles are easily demountable CE Marking - Ecophon ceiling systems CE marked construction products are covered by a Declaration of Performance (DOP). Make : Saint - Gobain Ecophon Sombra A or equivalent as approved by GE.
Material and labour for 12mm thick prelaminated particle board, interior grade, prelaminated one sides with decorative choice laminations & other side balancing white lamination fixed with screws to frame work as in ceiling and wall panelling complete all as specified and as directed,
Disconnecting of existing tanks capacity not exceeding 250 ltrs, setting aside (or lowering if required) for repairs, cleaning, etc and hoisting if required reconnecting and refixing in position complete all as specified and as directed.
Disconnecting of existing tanks capacity exceeding 250 ltrs & not exceeding 500 ltrs, setting aside (or lowering if required) for repairs, cleaning, etc and hoisting if required reconnecting and refixing in position complete all as specified and as directed.
Disconnecting existing tanks capacity exceeding 500 but not exceeding 1000 ltr, setting aside (or lowering if required) for repairs, cleaning etc and hosting if required, reconnecting & refixing in position complete all as specified and as directed.
Disconnecting existing tanks capacity exceeding 1000 but not exceeding 2000 ltr, setting aside (or lowering if required) for repairs, cleaning etc and hosting if required, reconnecting & refixing in position complete all as specified and as directed.
Labour only for Cleaning and removing all scale and dirt, etc from tanks and from mouths of circulating pipes etc of tanks capacity not exceeding 250 ltrs complete all as specified and as directed.
Labour only for Cleaning and removing all scale and dirt, etc from tanks and from mouths of circulating pipes etc of tanks capacity exceeding 250 ltrs and not exceeding 500 ltrs complete all as specified and as directed.
Labour only for Cleaning and removing all scale and dirt, etc from tanks and from mouths of circulating pipes etc of tanks capacity exceeding 500 ltrs and not exceeding 1000 ltrs complete all as specified and as directed.
Labour only for Cleaning and removing all scale and dirt, etc from tanks and from mouths of circulating pipes etc of tanks capacity exceeding 1000 ltrs and not exceeding 2000 ltrs complete all as specified and as directed.
Taking up or down 15 mm dia steel GI tubing and connections including cleaning for refixing complete all as specified and as directed.
Taking up or down 20 mm dia steel GI tubing and connections including cleaning for refixing complete all as specified and as directed.
Taking up or down 25 mm dia steel GI tubing and connections including cleaning for refixing complete all as specified and as directed.
Taking up or down 40 mm dia steel GI tubing and connections including cleaning for refixing complete all as specified and as directed.
Refixing old steel tubing 15 mm dia with all new fittings in new or old position, (Walls, Ceilings, floors, etc) complete all as specified and as directed.
Refixing old steel tubing 20 mm dia with all new fittings in new or old position, (Walls, Ceilings, floors, etc) complete all as specified and as directed.
Refixing old steel tubing 25 mm dia with all new fittings in new or old position, (Walls, Ceilings, floors, etc) complete all as specified and as directed.
Refixing old steel tubing 40 mm dia with all new fittings in new or old position, (Walls, Ceilings, floors, etc) complete all as specified and as directed.
Supply and fix triple layer Rotational moulded polyethylene water storage tanks of 500 ltrs capacity (cylindrical vertical with closed top) hoisting and fixed in position complete all as specified and as directed.
Supply and fix triple layer Rotational moulded polyethylene water storage tanks of 1000 ltrs capacity (cylindrical vertical with closed top) hoisting and fixed in position complete all as specified and as directed.
Supply and fix triple layer Rotational moulded polyethylene water storage tanks of 2000 ltrs capacity (cylindrical vertical with closed top) hoisting and fixed in position complete all as specified and as directed.
Supply and fix 25 mm bore GI pipe, medium grade with all fittings fixed complete to walls and ceiling or laid in floors, complete all as specified and as directed.
Supply and fix 40 mm bore of GI pipe, medium grade with all fittings fixed complete to walls and ceiling or laid in floors, complete all as specified and as directed.
Supply and fix Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for 25mm bore dia of pipe and fixed (minimum weight 25mm - 455 gms) complete all as specified and as directed.
Supply and fix Gun metal, globe valve, with iron wheel head, screwed both ends for 25mm pipe complete all as specified and as directed.
Taking down cement plaster on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
Material and labour Rendering 5mm thick in CM (1:3) on fair faces of brick work or concrete surfaces as in ceiling finished fair and even with out using extra cement complete all as specified and as directed.
Material and labour for preparing newly plastered ceilings surfaces and applying three coats of white wash complete all as specified and as directed.
Supply and fix 1.25mm thick mild steel sheet eaves gutter, 150mm dia, galvanised class 3, half round with rounded edges complete all as specified and as directed.
Supply and fix 110mm dia UPVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls complete all as specified and as directed.
Supply and fix 1.25mm thick mild steel sheet drop ends, 100mm dia, (for spigot or socket ends) or nozzles complete all as specified and as directed.
Supply and fix 110mm dia UPVC (SWR) bends any radius complete all as specified and as directed.
Supply and fix 1.25mm thick mild steel sheet stop ends, 150mm dia, (for spigot or socket ends) complete all as specified and as directed.
Material and labour for preparation of old painted steel surfaces of any description, not otherwise described over 10cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
Removal of concrete and plaster debris to a distance exceeding 5 Km and depositing where directed at a level not exceeding 1.50 m above the starting point complete all as specified and as directed.
Taking down carefully aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc removing materials for taking credit and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed.
Taking down carefully unserviceable main switches/DB's off size from their position complete all as specified and as directed.
Taking down existing sub main wiring with aluminium conductor cable of 2 of 1.5/4/6/10 sqmm with GI earth wire on and including wooden batten and removing materials from the site and making good disturbed surface of walls and roofs complete all as specified and as directed.
Material and Labour for point wiring with PVC unsheathed multi standard 1.5 Sqmm FRLS copper Cable for one light point controlled by one way switch, and wire to be drawn in and including PVC conduit/casing capping of suitable width complete with all accessories including MS sheet metal 1.2mm thick switch box with 3mm thick laminated sheet for housing switch/socket/regulator etc or PVC rectangular switch board of suitable size to be fixed on wall respectively including white washing/colour washing/distempering to match the disturbed surfaces including PVC unsheathed multi standard 1.5 Sqmm FRLS copper Cable as earth continuity conductor connected with common earth dolly complete all as specified and as directed for the following.
(a) One light point controlled by one, one way switch 5 Amp complete
(b) One fan point controlled by one, one way switch 5 Amp complete
(c) One bell point controlled by one bell push on independent board
(d) One 3 pin socket outlet 5 amp independent with other switches
(e) One 3 pin socket outlet 5 Amp on the same board with other switches
All as per srl item No 79 above but for one 3 pin socket outlet 15 Amp independent with cable of size 2.5 Sqmm for point wiring and 2.5 sqmm as in continuous earth wire complete all as specified and as directed.
Supply and fix switch piano flush type single pole one way 5 Amp 240 V complete all as specified and as directed.
Supply and fix switch socket combination 2 in 1, 3 pin 5 Amp flush type 240 volts complete all as specified and as directed.
Supply and fix socket outlet 3 pin, 5 Amp, flush type complete all as specified and as directed.
Supply and fix switch socket combination 5 in 1, 5 pin 15/16 Amp flush type 240 volts complete all as specified and as directed.
Material and labour complete for ceiling rose surface backelite three terminal 240 volts complete all as specified and as directed.
Supply and fix fan regulator, electronic, step type, flush mounting, socket size complete all as specified and as directed.
Supply and fix bell push, flush type, 5 Amp complete all as specified and as directed.
Supply and fix electric call bell Ding-Dong type AC 230 volts single pole complete all as specified and as directed.
Material and labour for Point wiring for explosive atmosphere with 1.5sqmm single core PVC insulated and unsheathed cable FRLS 1100V grade with multistranded copper conductor drawn through and including suitable ERW rigid stove enamelled steel conduit with & including bend/elbow/coupling & GI saddling clips etc, fixed on walls, roofs, floors etc. including 1.5 sqmm PVC insulated and unsheathed FRLS cable with stranded copper conductor for earth wire for One light / fan point controlled by one switch complete all as specified and as directed. NOTE : -Flame proof junction box shall be measured and paid separately under relevant item of the schedule.
Supply and fix Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and as directed.
Supply and fix flame proof junction box 4/2 way for cable entry complete all as specified and as directed.
Supply and fix LED light fitting 2 x 16 Watt flame proof, CMRI certified recommended for gas/vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and as directed.
Supply and fix exhaust fan, single phase, heavy duty, metal body, 225/240 sweep, 900 RPM, Double ball bearing, including fixing of mounting frame in the round hole cutting in the wall of brick/stone masonary by means of rugged bolts, nuts and washers etc & making good disturbed surfaces of walls etc, including louver shutter on outer surface of the wall and connecting with and including three core copper conductor flexible cord of 1.5 Sqmm cross sectional area of required length from ceiling rose to the connector block of the exhaust fan complete all as specified and as directed. Note : Quoted rate is deemed to be included the cutting in the wall and making good the surface to match with the existing surfaces.
Supply and fix ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed..
Supply and Fix Batten for LED tube with single LED Lamp 1x 20 w (Double side connection), Ultra bright glass LED Tubelight with very high efficacy with lamp holders etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed.
Supply and fix LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fix round shape 15 W 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size all as specified & directed.
Supply and fix Decorative, wall mounting fixture, in durable plastic body & designer mesh gold finish suitable for 9 watt LED lamp B22 base with 9 Watt LED Bulb. Make: Havells Cat No LHFOECE1TZ1B014 or equivalent make listed in PS.
Material and labour for sub main wiring with two single core stranded copper conductor unsheathed PVC insulated FRLS cable 1100V grade with 2.5 sq mm drawn through suitable size of non-metallic PVC rigid conduit with one run 2.5 sqmm copper conductor FRLS cable as earth conductor and conduit accessories fixed up in surface/recessed as required, including connecting up complete all as specified and as directed. NOTE:- Two runs of 2.5 sq mm cable and one run of 2.5 sq mm earth continuity copper conductor and one run of PVC conduit shall be measured as one unit.
Material and labour for sub main wiring with two single core stranded copper conductor unsheathed PVC insulated FRLS cable 1100V grade with 4 sq mm drawn through suitable size of non-metallic PVC rigid conduit with one run 4 sqmm copper conductor FRLS cable as earth conductor and conduit accessories fixed up in surface/recessed as required, including connecting up complete all as specified and as directed. NOTE:- Two runs of 4 sq mm cable and one run of 4 sq mm earth continuity copper conductor and one run of PVC conduit shall be measured as one unit.
Material and labour for sub main wiring with two single core stranded copper conductor unsheathed PVC insulated FRLS cable 1100V grade with 6 sq mm drawn through suitable size of non-metallic PVC rigid conduit with one run 6 sqmm copper conductor FRLS cable as earth conductor and conduit accessories fixed up in surface/ recessed as required, including connecting up complete all as specified and as directed. NOTE:- Two runs of 6 sq mm cable and one run of 6 sq mm earth continuity copper conductor and one run of PVC conduit shall be measured as one unit.
Supply and fix sheet metal enclosure factory made double door for DB 240 volts with 200 Amps rated bus bar SPN 4 Way including taking down old unserviceable enclosure complete all as specified and as directed.
Supply and fix sheet metal enclosure factory made double door for DB 240 volts with 200 Amps rated bus bar SPN 6 Way including taking down old unserviceable enclosure complete all as specified and as directed.
Supply and fix sheet metal enclosure factory made double door for DB 240 volts with 200 Amps rated bus bar SPN 8 Way including taking down old unserviceable enclosure complete all as specified and as directed .
Supply and fix sheet metal enclosure factory made double door for TPN DB 4 Way 415 volts including taking down old unserviceable enclosure complete all as specified and as directed.
Supply and fix sheet metal enclosure factory made double door for VTPN DB 4 Way 415 volts including taking down old unserviceable enclosure complete all as specified and as directed.
Supply and fix sheet metal enclosure factory made double door for VTPN DB 8 Way 415 volts, Four Pole with MCCB main incoming including taking down old unserviceable enclosure complete all as specified and as directed. Note for item No. 112: MCCB shall be measured and paid separately.
Supply and fix MCCB four pole 125 Amps, 25 KA, 415 volts, 50 Hz AC supply complete all as specified & directed including taking down old unserviceable one complete all as specified and as directed.
Supply and fix MCB TPN 16-32 Amps, C Curve, 415 volts, 50 Hz AC supply including taking down old unserviceable one complete all as specified and as directed.
Supply and fix MCB TPN 40-63 Amps, C Curve, 415 volts, 50 Hz AC supply including taking down old unserviceable one complete all as specified and as directed.
Supply and fix MCB SPN, C Curve, 16-32 Amps 240 volts, 50 Hz AC supply including taking down old unserviceable one complete all as specified and as directed.
Supply and fix MCB SP 06 to 32 Amps, C Curve, 240 volts, 50 Hz AC supply including taking down old unserviceable one complete all as specified and as directed.
Taking down ceiling fan/exhaust fan, dismantling blades and removing fan and blades, Painting of fans complete in situ with synthetic enamel paint by spraying including filling cavities with filler one coat after cleaning all dust etc and refixing ceiling fan/exhaust fan and connecting up including provision of three core twisted flexible copper conductor cable with suitable size from ceiling rose or connector of fan complete all as specified and as directed.
Supply and fix LED street light made of pressure die cast housing with toughened glass and high power LEDs with option of secondary optic with IP-66 protection with SPD LED street light of 25 Watt all as Crompton Cat Part No - LSTS-25-CDL-M of Crompton make or equivalent make of Bajaj/Philips/Wipro/Havells. With suitable size bracket made to shape of 40 mm dia GI pipe medium grade of 1.2 mtr length including MS clamps 25 x 4 mm - 02 Nos with nut bolts washers complete all as specified and as directed.
Supply and Fix LED Light fitting 36 Watts of size 600 mm x 600 mm, 220 V AC with high efficiency PMMA diffuser soft glare free light LED edge-lite luminaries suitable for armstrong/grid ceiling complete for low ceiling application with LED Driver of 36 Watts complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size complete all as specified and as directed.
Repairing the unserviceable ceiling fans including transporting to local work shop opening the motor and taking out the old burnt out copper winding wire from the fan of 1200/1400mm sweep and rewinding by using same gauge of copper wire insulating and varnishing and depositing back to MES store complete all as specified and as directed. Note:- Quoted rate is deemed to be included the cost of cleaning and servicing/repairing/rewinding work/other connected items and provision 3 core 1.5 sqmm copper flexible cable from ceiling rose to the fan.
Repairing the unserviceable heavy duty exhaust fans including transporting to local work shop, opening the motor and taking out the old burnt out copper winding wire from the fan of 300/350/380 mm sweep and rewinding by using same gauge of copper wire insulating and varnishing and depositing back to MES store complete all as specified and as directed. Note:- Quoted rate is deemed to be included the cost of cleaning and servicing/repairing/rewinding work/other connected items and provision of 3 core 1.5 sqmm copper flexible cable from ceiling rose to the fan.
Taking down the unserviceable wall mounting fans, dismantling the blades, transporting to local work shop, opening the motor and taking out the old burnt out copper winding wire from the fan of 400 mm sweep and rewinding by using same gauge of copper wire insulating and varnishing, assembling, transporting back and refixing at site complete all as specified and as directed. Note:- Quoted rate is deemed to be included the cost of cleaning, servicing, other connected items and provision of 3 core 1.5 sqmm copper flexible cable from ceiling rose to the fan.
Supply and fix in repair LED Bulb 9 Watt complete all as specified and as directed.
Material and labour for Earthing complete with galvanised mild steel earth plate electrode of size 600 x 600 x 6mm thick buried directly in ground earth (in vertical) earth pit not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr below ground level, connected to galvanised iron or earth lead wire 4.0 mm dia (8 SWG) by means of nut, bolt, check nuts and washer of galvanised iron including PCC pit in PCC 1:2:4 type B-1 pre-cast RCC cover slab using reinforcement with XPM weighing not less than 1.87 kg/Sqm with suitable handle made of 12mm round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh 15mm dia bore light grade galvanised steel tubing upto 7.5 m length for drawing earth lead wire protection, common salt, charcoal, etc all as shown in electrical plate No 3 of SSR Part-I and testing on completion complete including taking down existing earthing all as specified and as directed.
Dismantling and taking out existing unserviceable disconnected XLPE cables of 120/50/25/16/10/6 Sqmm 2/3.5/4 Core from its existing location complete all as specified and as directed.
Supply, laying, connect and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sqmm 3.5 core complete all as specified and as directed.
Supply, laying, connect and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sqmm 3.5 core complete all as specified and as directed.
Supply, laying, connect and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sqmm 3.5 core complete all as specified and as directed.
Supply, laying, connect and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 4 core complete all as specified and as directed.
Supply, laying, connect and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm 4 core complete all as specified and as directed.
Supply, laying, connect and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 2 core complete all as specified and as directed.
Supply, laying, connect and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm 2 core complete all as specified and as directed.
Supply, laying, connect and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm 2 core complete all as specified and as directed.
Supply, install, testing and commissioning of LT Feeder pillar Box AC 415 V, 50 HZ 3 Phase 4 wire of suitable size to accommodating the following accessories totally enclosed self supporting structure / cubicle, fully compartmentalized type, weather proof, vermin proof outdoor type made out of 3.15 mm thick MS sheet protection IP 54, suitable for outdoor use, with bottom cable entry with suitable cable glands structure with angle iron frame work with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter and MCCBs, double hinged doors at front with suitable locking arrangement, Provision of louvers at sides, structure treated under 7 - tank metal treatment process and duly powder coated with 200A electrical grade aluminium bus bar for phases and neutral complete with suitable digital type meters resin cast CTs, CPRI approved type tested, internal wiring all including the following incoming complete all as specified and as directed (LT Panel-1):- Note:- Connection from Main bus bar to Outgoing MCCB should be provided through bus bar of suitable rating instead of copper wires
Supply, install, testing and commissioning of LT Feeder pillar Box AC 415 V, 50 HZ 3 Phase 4 wire of suitable size to accommodating the following accessories totally enclosed self supporting structure / cubicle, fully compartmentalized type, weather proof, vermin proof outdoor type made out of 3.15 mm thick MS sheet protection IP 54, suitable for outdoor use, with bottom cable entry with suitable cable glands structure with angle iron frame work with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter and MCCBs, double hinged doors at front with suitable locking arrangement, Provision of louvers at sides, structure treated under 7 - tank metal treatment process and duly powder coated with 250A electrical grade aluminium bus bar for phases and neutral complete with suitable digital type meters resin cast CTs, CPRI approved type tested, internal wiring all including the following incoming complete all as specified and directed (LT Panel-2):- Note:- Connection from Main bus bar to Outgoing MCCB should be provided through bus bar of suitable rating instead of copper wires
Supply, install, testing and commissioning of LT Feeder pillar Box AC 415 V, 50 HZ 3 Phase 4 wire of suitable size to accommodating the following accessories totally enclosed self supporting structure / cubicle, fully compartmentalized type, weather proof, vermin proof outdoor type made out of 3.15 mm thick MS sheet protection IP 54, suitable for outdoor use, with bottom cable entry with suitable cable glands structure with angle iron frame work with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter and MCCBs, double hinged doors at front with suitable locking arrangement, Provision of louvers at sides, structure treated under 7 - tank metal treatment process and duly powder coated with 200A electrical grade aluminium bus bar for phases and neutral complete with suitable digital type meters resin cast CTs, CPRI approved type tested, internal wiring all including the following incoming complete all as specified and as directed (LT Panel-3):- Note:- Connection from Main bus bar to Outgoing MCCB should be provided through bus bar of suitable rating instead of copper wires
Material and Labour for Earthing and testing complete with galvanized iron earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 M below normal ground level with top edge of earth plate at a depth not less than 1.5 M below normal ground level connected to and including GI strip 32 x 6 mm as earth lead by means of bolts and nuts, check nuts and washers etc made of GI & connected to equipment and earthing test point, earth dolly all as shown in elect plate No 3 of SSR Pt-I including all necessary earth work, excavation PCC chamber cover with handle (PCC 1:2:4) and 20mm dia GI watering pipe and 40 mm dia light grade GI for protection of earth strip, wire mesh, funnel, charcoal dust & common salt, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing on completion complete all as specified and as directed. Note: GI strip of length upto 7.5m shall be deemed to be included in the quoted rate.
Supply and fix GI Strip of size 32x6 mm complete all as specified and as directed.
Material and labour for LT Cable route indicator with a welded/riveted disc of 4 inch dia and engraved with cable with cable route marker made out of angle iron 40 x 40 x4 mm thick dug in ground with in and including PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate at approx distance 100 mtr including necessary earth work complete all as specified and as directed
Supply and fix DWC HDPE Pipe IS-16205, size inner dia 103 mm, outer dia 120 mm for cable protection in wall/under ground laying of UG cables including SNAP-FIT Coupler and all fittings as required at site complete all as specified and as directed. Make: ASTRAL / KETRON/DUTRON / DURALINE
Supply and fix DWC HDPE Pipe IS-16205, size inner dia 63 mm, outer dia 75 mm for cable protection in wall/under ground laying of UG cables including SNAP-FIT Coupler and all fittings as required at site complete all as specified and as directed. Make: ASTRAL / KETRON/DUTRON / DURALINE
Excavation in trenches for laying underground cables, poles and stays in any type of soil not exceeding 1.5M wide and not exceeding 1.5 M deep and getting out complete all as specified and as directed.
Returning filling in with excavated soil including spreading leveling watering and well ramming in layers not exceeding 25 cms thick complete all as specified and as directed.
Removing surplus excavated material to a distance not exceeding 50 Mtr and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and as directed.
Cutting the tar macadam road / hard standings for laying cable and excavating not exceeding 1.5 wide and 1.5m in depth and getting out all as directed including filing back and finishing it with PCC 1:2:4 type B1 using 20mm graded stone aggregate, 200mm thick complete matching with the surroundings complete all as specified and as directed.
Supply and fix 40mm dia GI pipes light grade galvanised with all fitting and fixed complete to poles/route/drains etc and ceilings or laid in floors complete all as specified and as directed.
Supply and fix 50mm dia GI pipes light grade galvanised with all fitting and fixed complete to poles/route/drains etc and ceilings or laid in floors complete all as specified and as directed.
Supply and fix 80mm dia GI pipes light grade galvanised with all fitting and fixed complete to poles/route/drains etc and ceilings or laid in floors complete all as specified and as directed.
Rajan Traders
Phoenix Infra
K. VENKATESH NAIDU
C R R CONSTRUCTIONS
SOOD ASSOCIATES PVT LTD
INDGUARD ENGINEERS
M Mohan Babu
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .