Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹8.7 LAccepted-Finance | 1 | Accepted-Finance L1 | |
| 2 | 2₹9.5 L+₹76,616 (8.81%)Accepted-Finance | 2 | Accepted-Finance L2 |
Tender Value
₹10.5 L
EMD Value
₹20,943
Closing Date
24 Jun 2025, 3:00 pmClosed
Executive Engineer PRI, NMA, Mayabunder
Office of Executive Engineer PRI, NMA, Mayabunder
Construction of Electrification Ceiling and Water Tank of Community Hall at Chainpur ward No. 04 under Gram Panchayat, Chainpur.
2025_RDPRI_18900_1
140/EE/PRI/NMA/MB/24-2025
Open Tender
Electrical Works
Works
180 days
Chainpur
Refer Tender Document
5 documents required · 5 mandatory
₹500
The Executive Engineer PRI, NMA, Mayabunder
₹20,943
30 Jun 2025
14 Jun 2025
24 Jun 2025
14 Jun 2025
24 Jun 2025
14 Jun 2025
Amount
Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately).
Providing and fixing 6 mm dia. G.I. level adjusting hangers (upto 1200mm length), fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40x3mm size 60 mm long and stainless steel expandable dash fastener of 12.5 mm dia and 50 mm long, complete as per direction of Engineer-in-charge.
Providing and fixing flat pressed 3 layer medium density particle board or graded particle board (Grade I) IS: 3087 marked, in ceiling with necessary nails etc. complete (frame work to be paid separately):
12 mm thick
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:4:8 (1 Cement : 4 pulverised sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
1:3:6 (1 Cement : 3 pulverised sand (zone-III) derived from natural sources: 6 graded stone aggregate 40 mm nominal size derived from natural sources).
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, ifnishing and reinforcement- All work up to plinth level :
1:1.5:3 (1 cement: 1.5 pulverised sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement
1:1.5:3 (1 cement : 1.5 pulverised sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement: 1.5 pulverised sand (zone-III)derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Centering and shuttering including strutting, propping etc. and removal of form for
Foundations, footings, bases of columns, etc. for mass concrete
Columns, Pillars, Piers, Abutments, Posts and Struts
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Suspended floors, roofs, landings, balconies and access platform
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
12 mm cement plaster of mix :
1:4 (1 cement: 4 River sand)
12 mm cement plaster finished with a floating coat of neat cement of mix :
1:4 (1 cement: 4 River sand)
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work
15 mm dia nominal bore
25 mm dia nominal bore
Providing and fixing brass bib cock of approved quality :
15 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
25 mm nominal bore
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
Semi rigid pipe
32 mm dia
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) :
25 mm nominal bore
ELECTRICAL WORKS
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC Conduit, with piano type switch, suitable size PVC box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
Group C
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC Conduit, alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC Conduit as required
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing Suitable PVC box on surface or in recess, including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required.Make anchor/Polycab/Havells.
Supplying and fixing Suitable PVC box on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.Make anchor/Polycab/Havells.
Supplying of prewired LED tube light T5 20W /22W ( MAKE INTENSO LXS BATTEN 4 FEET 20 W))(Make Havells/Polycab/Crompton) or equivalent to ISI standard.
Installation, testing and commissioning of pre-wired, LED FITING of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Supplying and fixing stepped type electronic fan regulator (Shocket type)on the switch box including connections etc. as required.Make : anchor/polycab/havells etc or equvalent to ISI standard.
Supplying of A.C. Ceiling fan (1200mm sweep 1 Star Ratting)USHA ENERGIA 50W suitable for operation on 230 Volts, single Phase, 50Hz, A.C Supply including 300mm long rod and without regulator as required. (Make: Bajaj/ Usha/ Orient/Crompton or equivalent to ISI standard).
Installation, testing and commissioning of ceiling fan, including down road and wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ PVC block including connection etc as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB /RCCB /Isolator)
8 way Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single Pole MCB
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
40 Amps, 2 Pole Isolator
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Providing and laying earth connection from earth electrode with 6.00 sq mm FR Flexible Wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
Providing and fixing 6.00 sq mm FR Flexible Wire on surface or in recess for loop earthingas required.
Supplying and fixing of new generation energy saving enviroment friendly long life 25 W LED street light made up of pressure dia cast aluminium housing with high power LED as light source and embeded PC cover having top opening seprate driver compertment with IP65 PROTECTION AND ik07 IMPACET RESISTENCE (MAKE : Polycab CAT No.PUBO506109 ) along with its Mountning (GI PIPE 32mm) (Make: Bajaj /Havells /Orient/Crompton or equivalent to ISI standard).
Supplying ,Tesing and commissioning of clamp type Ceiling Fan hook in 40mm Dia Truss Pipe etc as required.
Radha Kumari (BID ID -55627)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .