| 1 | L1₹45.7 LAccepted-AOC BASEMENT PLOT NO 17 4657 21 ANSARI ROAD CENTRAL DELHI NEW DELHI 110002 | CENTRAL DELHI | DELHI | 110002 | L1 | Accepted-AOC AOC | |
| 2 | L2₹51.8 L+₹1.9 L (3.77%)Rejected-Finance BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | L2 | Rejected-Finance Due not L1 bidder | |
| 3 | L3₹52.8 L+₹2.8 L (5.67%)Rejected-Finance 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | L3 | Rejected-Finance Due not L1 bidder | |
| 4 | L4₹53.2 L+₹3.2 L (6.43%)Rejected-Finance G 58 KIRAN GARDEN UTTAM NAGAR NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L4 | Rejected-Finance Due not L1 bidder | |
| 5 | L5₹70.5 L+₹20.6 L (41.2%)Rejected-Finance A 303 VEENA CGHS LTD PLOT NO 5D SECTOR 22 DWARKA NEW DELHI 110077 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110077 | L5 | Rejected-Finance Due not L1 bidder |
| Sl No | Description | Qty | Unit | Sumit Enterprises L4 | Rahul Enterprises L2 | VINAY ENTERPRISES L1 | Ridhi engineers and builders L5 | M P TYAGI ENGINEERS AND CONTRACTORS L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Opening the electric induction motor of capacity 10-25 HP and taking out the burnt winding wire complete and cleaning the slots, rewinding the motor with super enamalled copper winding wire of existing size/gauge with and including all other insulating material complete all as specified and as directed.
Note : "Copper winding wire of appropriate gauge will be measured under item No. 22 as supply only here-in-after." | 6 | Each job | 1,500 ₹9,000 | 1,500 ₹9,000 | 1,200 ₹7,200 Lowest | 7,500 ₹45,000 | 1,999 ₹11,994 |
| 2.00 | Opening the electric induction motor of capacity 30-40HP and taking out the burnt winding wire complete and cleaning the slots, rewinding the motor with super enamalled copper winding wire of existing size/gauge with and including all other insulating material complete all as specified and as directed.
Note : "Copper winding wire of appropriate gauge will be measured under item No. 22 as supply only here-in-after." | 6 | Each job | 2,100 ₹12,600 | 2,000 ₹12,000 | 1,800 ₹10,800 Lowest | 9,000 ₹54,000 | 1,999 ₹11,994 |
| 3.00 | Opening the electric induction motor of capacity 50-75 HP and taking out the burnt winding wire complete and cleaning the slots, rewinding the motor with super enamalled copper winding wire of existing size/gauge with and including complete all as specified and as directed.
Note : "Copper winding wire of appropriate gauge will be measured under item No. 22 as supply only here-in-after." | 6 | Each job | 2,500 ₹15,000 | 3,450 ₹20,700 | 2,200 ₹13,200 Lowest | 15,000 ₹90,000 | 2,999 ₹17,994 |
| 4.00 | Opening the electric induction motor of capacity 75-200 HP and taking out the burnt winding wire complete and cleaning the slots, rewinding the motor with super enamalled copper winding wire of existing size/gauge with and including complete all as specified and as directed.
Note : "Copper winding wire of appropriate gauge will be measured under item No. 22 as supply only here-in-after." | 3 | Each Job | 4,500 ₹13,500 | 4,350 ₹13,050 | 4,100 ₹12,300 Lowest | 25,000 ₹75,000 | 4,999 ₹14,997 |
| 5.00 | Disconnecting of electrical connections from panel board and taking out electic motor of capacity 10-25 HP from base plate of pump set after opening the nuts, bolts and transporting the motor to workshop and back, reinstalled after repair and testing complete all as specified and as directed. | 6 | Each Job | 1,500 ₹9,000 | 1,500 ₹9,000 | 1,400 ₹8,400 | 900 ₹5,400 Lowest | 2,499 ₹14,994 |
| 6.00 | Disconnecting of electrical connections from panel board and taking out electic motor of capacity 30-40 HP from base plate of pump set after opening the nuts, bolts and transporting the motor to workshop and back, reinstalled after repair and testing complete all as specified and as directed. | 6 | Each Job | 2,100 ₹12,600 | 2,000 ₹12,000 | 1,900 ₹11,400 | 1,500 ₹9,000 Lowest | 2,999 ₹17,994 |
| 7.00 | Disconnecting of electrical connections from panel board and taking out electic motor of capacity 50-75 HP from base plate of pump set after opening the nuts, bolts and transporting the motor to workshop and back, reinstalled after repair and testing complete all as specified and as directed. | 6 | Each Job | 2,500 ₹15,000 | 2,500 ₹15,000 | 2,450 ₹14,700 Lowest | 4,500 ₹27,000 | 4,999 ₹29,994 |
| 8.00 | Disconnecting of electrical connections from panel board and taking out electic motor of capacity 75-200 HP from base plate of pump set after opening the nuts, bolts and transporting the motor to workshop and back, reinstalled after repair and testing complete all as specified and as directed. | 3 | Each Job | 4,500 ₹13,500 | 4,250 ₹12,750 Lowest | 4,400 ₹13,200 | 9,000 ₹27,000 | 8,999 ₹26,997 |
| 9.00 | Supply only terminal box for 10-25 HP Motor. | 6 | Each | 200 ₹1,200 | 200 ₹1,200 | 200 ₹1,200 | 450 ₹2,700 | 99 ₹594 Lowest |
| 10.00 | Supply only terminal box for 30-40 HP Motor. | 6 | Each | 250 ₹1,500 | 250 ₹1,500 | 230 ₹1,380 | 750 ₹4,500 | 99 ₹594 Lowest |
Tender Value
₹75.8 L
EMD Value
₹1.4 L
Closing Date
5 Dec 2025, 6:00 pmClosed
HQ CWE (U) Delhi Cantt-110010
HQ CWE (U) Delhi Cantt-110010
REPAIR/MAINT/DEVELOPMENT OF BOREWELLS AND RAIN WATER HARVESTING SYSTEM CENTRIFUGAL PUMPS SUBMERSIBLE PUMPS/MONOBLOCK PUMPS AND CONNECTED ITEMS IN WATER SUPPLY INSTALLATION AT NODAL POINT I DK-II SP MARG NICHOLSON RANGE AND SIGNAL AREA AND CONNECTED A
2025_MES_738963_1
CWE (U)/D-35/2025-26
Open Tender
Civil Works
Works
180 days
HQ CWE (U) Delhi Cantt
Please refer Tender Documents
9 documents required · 9 mandatory
₹1,000
GE (U) Water Supply
₹1.4 L
Yes
18 Feb 2026
8 Nov 2025
12 Dec 2025
8 Nov 2025
5 Dec 2025
29 Nov 2025
Amount
Opening the electric induction motor of capacity 10-25 HP and taking out the burnt winding wire complete and cleaning the slots, rewinding the motor with super enamalled copper winding wire of existing size/gauge with and including all other insulating material complete all as specified and as directed. Note : "Copper winding wire of appropriate gauge will be measured under item No. 22 as supply only here-in-after."
Opening the electric induction motor of capacity 30-40HP and taking out the burnt winding wire complete and cleaning the slots, rewinding the motor with super enamalled copper winding wire of existing size/gauge with and including all other insulating material complete all as specified and as directed. Note : "Copper winding wire of appropriate gauge will be measured under item No. 22 as supply only here-in-after."
Opening the electric induction motor of capacity 50-75 HP and taking out the burnt winding wire complete and cleaning the slots, rewinding the motor with super enamalled copper winding wire of existing size/gauge with and including complete all as specified and as directed. Note : "Copper winding wire of appropriate gauge will be measured under item No. 22 as supply only here-in-after."
Opening the electric induction motor of capacity 75-200 HP and taking out the burnt winding wire complete and cleaning the slots, rewinding the motor with super enamalled copper winding wire of existing size/gauge with and including complete all as specified and as directed. Note : "Copper winding wire of appropriate gauge will be measured under item No. 22 as supply only here-in-after."
Disconnecting of electrical connections from panel board and taking out electic motor of capacity 10-25 HP from base plate of pump set after opening the nuts, bolts and transporting the motor to workshop and back, reinstalled after repair and testing complete all as specified and as directed.
Disconnecting of electrical connections from panel board and taking out electic motor of capacity 30-40 HP from base plate of pump set after opening the nuts, bolts and transporting the motor to workshop and back, reinstalled after repair and testing complete all as specified and as directed.
Disconnecting of electrical connections from panel board and taking out electic motor of capacity 50-75 HP from base plate of pump set after opening the nuts, bolts and transporting the motor to workshop and back, reinstalled after repair and testing complete all as specified and as directed.
Disconnecting of electrical connections from panel board and taking out electic motor of capacity 75-200 HP from base plate of pump set after opening the nuts, bolts and transporting the motor to workshop and back, reinstalled after repair and testing complete all as specified and as directed.
Supply only terminal box for 10-25 HP Motor.
Supply only terminal box for 30-40 HP Motor.
Supply only terminal box for 50-75 HP Motor.
Supply only terminal box for 75-200 HP Motor.
Supply only terminal connection plate for 10-25 HP Motor.
Supply only terminal connection plate for 30-40 HP Motor.
Supply only terminal connection plate for 50-75 HP Motor.
Supply only terminal connection plate for 75-200 HP Motor.
Supply and Fixing in replacement of CI bearing plate for electric motor 10-25 HP complete all as specified and directed.
Supply and Fixing in replacement of CI bearing plate for electric motor 30-40 HP complete all as specified and directed.
Supply and Fixing in replacement of CI bearing plate for electric motor 50-75 HP complete all as specified and directed.
Supply and Fixing in replacement of CI bearing plate for electric motor 75-200 HP complete all as specified and directed.
Disconnecting of electrical connection from panel board and taking out monoblock pump of capacity upto 10 HP from foundation transporting the monoblock to workshop and back after repair, reinstall and testing complete all as specified and as directed
Supply only super enamelled copper winding wire of suitable gauge complete all as specified and directed.
Opening the monoblock pump set of capacity upto 10 HP and taking out the burnt winding wire complete and cleaning the slots rewinding the motor with super enamelled copper wire of existing gauge/size with and including insulating material, compete all as specified and as directed. Note : "Copper winding wire of appropriate gauge will be measured under item No.22 as supply only here-in-before."
Disconnecting and De-coupling the centrifugal pump of capacity 10-25 HP from foundation after cutting of rusted MS nuts, bolts and transported to workshop for repairing and back, re-installed in existing position complete including MS nuts, bolts and packing flange complete all as specified and as directed.
Disconnecting and De-coupling the centrifugal pump of capacity 30-40 HP from foundation after cutting of rusted MS nuts, bolts and transported to workshop for repairing and back, re-installed in existing position complete including MS nuts, bolts and packing flange complete all as specified and as directed.
Disconnecting and De-coupling the centrifugal pump of capacity 50-75 HP from foundation after cutting of rusted MS nuts, bolts and transported to workshop for repairing and back, re-installed in existing position complete including MS nuts, bolts and packing flange as directed by engr-in-charge
Disconnecting and De-coupling the centrifugal pump of capacity 75-200 HP from foundation after cutting of rusted MS nuts, bolts and transported to workshop for repairing and back, re-installed in existing position complete including MS nuts, bolts and packing flange as directed by engr-in-charge
Opening the centrifugal pump and repairing the same by replacing the unserviceable spare parts including machining work and re-assembling the same in original position of 10 to 25 HP. Note :- Spare Part will be measured & paid spaerately
Opening the centrifugal pump and repairing the same by replacing the unserviceable spare parts including machining work and re-assembling the same in original position of 30 to 40 HP. Note :- Spare Part will be measured & paid spaerately
Opening the centrifugal pump and repairing the same by replacing the unserviceable spare parts including machining work and re-assembling the same in original position of 50 to 75 HP. Note :- Spare Part will be measured & paid spaerately
Opening the centrifugal pump and repairing the same by replacing the unserviceable spare parts including machining work and re-assembling the same in original position of 75 to 200 HP. Note :- Spare Part will be measured & paid spaerately
Supply only following spare parts for centrifugal pump of capacity 10-25 HP
CI Impaller
CI Casing wear ring DE/NDE
CI Gland plate
Key for impeller
Impeller nut
Remetalling of pump shaft turning and balancing
CI Stuffing box bush
Pump shaft SS (AISI-410)
Gland packing champion
CI Bearing cartiage DE/NDE
CI Tyre coupling type TC/P/011
SS Eye bolt with nut
CI Shaft sleeve
Set Gasket packing.
MS Stud with nut
Supply only following spare parts for centrifugal pump of capacity 30-40 HP
CI Impaller
CI Casing wear ring DE/NDE
CI Gland plate
Key for impeller
Impeller nut
Remetalling of pump shaft turning and balancing
CI Stuffing box bush
Pump shaft SS (AISI-410)
Gland packing champion
CI Bearing cartiage DE/NDE
CI Tyre coupling type TC/Q/014
SS Eye bolt with nut
CI Shaft sleeve
Set Gasket packing.
MS Stud with nut
Supply only following spare parts for centrifugal pump of capacity 50-75 HP
CI Impaller
CI Casing wear ring DE/NDE
CI Gland plate
Key for impeller
Impeller nut
Remetalling of pump shaft turning and balancing
CI Stuffing box bush
Pump shaft SS (AISI-410)
Gland packing champion
CI Bearing cartiage DE/NDE
CI Tyre coupling type TC/Q/014
SS Eye bolt with nut
CI Shaft sleeve
Set Gasket packing.
MS Stud with nut
MS coupling key
Supply only following spare parts for centrifugal pump of capacity 75-200 HP
CI Impaller
CI Casing wear ring DE/NDE
CI Gland plate
Key for impeller
Impeller nut
Remetalling of pump shaft turning and balancing
CI Stuffing box bush
Pump shaft SS (AISI-410)
Gland packing champion
CI Bearing cartiage DE/NDE
CI Tyre coupling type TC/Q/014
SS Eye bolt with nut
CI Shaft sleeve
Set Gasket packing.
MS Stud with nut
MS coupling key
M&L for spray painting (two coat of synthetic enamel paint) on centrifugal pump & motor of any capacity rating 10-200 HP, scratching the rusted and suction/delivery pipe line including NRV and sluice valve, MS Base chanel complete all as specified and as directed.
S/F in replacement of MS base channel of existing size including cutting welding making hole and painting (two coat of synthetic enamel paint over a coat of red oxide) complete all as specified and as directed.
S/F in replacement of MS foundation bolts with nuts and washers of size 20 mm dia and 450 mm long
Supply and Fixing Ball bearing 6305 complete all as specified and directed.
Supply and Fixing Ball bearing 6306 complete all as specified and directed.
Supply and Fixing Ball bearing 6307 complete all as specified and directed.
Supply and Fixing Ball bearing 6308 complete all as specified and directed.
Supply and Fixing Ball bearing 6309 complete all as specified and directed.
Supply and Fixing Ball bearing 6310 complete all as specified and directed.
Supply and Fixing Ball bearing 6311 complete all as specified and directed.
Supply and Fixing Ball bearing 6312 complete all as specified and directed.
Supply and Fixing Ball bearing 6313 complete all as specified and directed.
Supply and Fixing Ball bearing 6314 complete all as specified and directed.
Supply and Fixing of double ball bearing 3307 complete all as specified and directed.
Supply and Fixing of double ball bearing 3309 complete all as specified and directed.
Supply and Fixing of double ball bearing 21309 complete all as specified and directed.
Supply and fixing of Rollar bearing No-313 complete all as specified and directed.
Supply and fixing of Rollar bearing No-314 complete all as specified and directed.
Supply and fixing in replacement of CI Foot Valve flanged 100 mm bore complete all as specified and as directed.
Supply and fixing in replacement of CI Foot Valve flanged 150 mm bore complete all as specified and as directed.
Supply and fixing of CI Non return valve of follolwing sizes complete all as specified and as directed.
300 mm bore dia.
250 mm bore dia.
150 mm bore dia.
100 mm bore dia.
80 mm bore dia.
Supplying & Fixing , jointing and testing of cast iron Sluice Valve ISI marked (PN-1.0) confirming to IS 14846-2000, flanged ends drilled having stainless steel spindle with cast iron wheel at top with nuts, bolts, washers and gaskets complete all as specified and as directed
200 mm bore dia
150 mm bore dia.
100 mm bore dia..
Supply and fixing in replacement of power contactor type ML-12 complete all as specified and directed.
Supply and fixing in replacement of power contactor type ML-6 complete all as specified and directed.
Supply and fixing in replacement of power contactor type ML-4 complete all as specified and directed.
M&L PVC insulated multistranded copper conductor wire 1100 volts in replacement single core of size 10.00 Sq mm complete all as specified and as directed.
M&L PVC insulated multistranded copper conductor wire 1100 volts in replacement single core of size 16.00 Sq mm complete all as specified and as directed.
M&L PVC insulated multistranded copper conductor wire 1100 volts in replacement single core of size 25.00 Sq mm complete all as specified and as directed.
M&L PVC insulated multistranded copper conductor wire 1100 volts in replacement single core of size 50.00 Sq mm complete all as specified and as directed.
M&L PVC insulated multistranded copper conductor wire 1100 volts in replacement single core of size 95.00 Sq mm complete all as specified and as directed.
S & F in replacement of biometallic thermal over load relay 415 volts 50 Hz, of range 9-14 amp complete all as specified and as directed.
S & F in replacement of biometallic thermal over load relay 415 volts 50 Hz, of range 13-21 amp complete all as specified and as directed.
S & F in replacement of biometallic thermal over load relay 415 volts 50 Hz, of range 20-32 amp complete all as specified and as directed.
S & F in replacement of biometallic thermal over load relay 415 volts 50 Hz, of range 28-42 amp complete all as specified and as directed.
S & F in replacement of amp meter 0 to 100 Amp of size 96 mm x 96 mm digital type complete all as specified and as directed.
S & F in replacement of volt meter 0 to 500 Volts of size 96 x 96 mm digital type complete all as specified and as directed.
S&F in replacement Timer analog type complete all as specified and directed.
Disconnecting Electric connections from LT Control pannel and starter of non clogging submerssible Sewage pump set of any size upto 10 HP capacity and removing the pipe line connections from discharge side and taking out submersible pump set along with, column pipe from sewage sump with the help of chain pully block including transportation to workshop and back for repair and lowering of same pump in sewage sump after repair including replacement of rusted nuts bolts, rubber gasket complete all as specified and as directed
Labour for opening the non-clogging submerssible Sewage pump set, repairing, rewinding and assembling the pump set including insulating material of any size 5HP to 10 HP capacity complete all as specified and as directed. (Copper winding wire and other spare parts required for repairing will be measured and paid under relevant item as supply only.
Supply and in replacement following spare parts for non-clogging sewage submersible pump set vertical type (KRTU type) of capacity upto 25 HP
SS rotor sleeve
SS rotor shaft ASS 410
Joint of submersible cable
Submersible cable flat/round 3 Core 10 Sqmm
Ball bearing 6312ZZ
Roller Bearing 3310
Roller Bearing NU 305
Bearing 6306 2RS1/C3
Bearing 6308 2RS1/C3
Bearing 6309 2 R S1/C3
Bearing 3212
Mechanical seal up to 10 HP
Supply and fixing in replacement of CI casing body of pump capacity 40/50/75 HP kirloskar make at site with and including Installation testing allignment and nut bolt washer etc complete all as specified and as directed.
M&L earthing complete with galvanised steel earth plate electrode 60x60 cmx 6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below nominal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to galvanised iron strip 32x6 mm as earthing lead by mean of bolts, nuts, check nuts and washer of galvanised iron or steel all as shown in Electrical plate No-3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed. (Note:- GI strip 32x6mm upto 7.5 RM shall be included in quoted unit rate and if extra required the same shall be measured and paid seperately under respective items.)
Supply and fixing LED street light fitting 70Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
M&L for replacing unserviceable gland packing champion of pump set of any capacity upto 200 HP at site complete all as specified and as directed.
S&F in replacement of pressure gauge (0-10 Kg/Sqcm) with connecting accessories of suitable size for pumps complete all as specified and as directed.
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr deep for pipe line/cable in any type of soil getting out and levelling of bottom surface to required level complete all as specified and as directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all as specified and directed.
Removing excavated material from site to a distance not exc 50mtr away and depositing where directed not exc 1.5mtr from the starting point complete all as specified and directed.
Surface dressing n.exc 30 cm deep averaging 15 cm deep for cleaning the area by cutting the unwanted bushes/vegitation growth in and arround the area of installations /around the valve pit chamber/along the pipe line routes if reqd etc and getting out soft/loose soil complete all as specified and directed.
Disconnecting electric connections from LT Control pannel and starter of submerssible pump set of any size 5HP to 20 HP and removing the pipe line connections from discharge side and taking out submerssible pump set along with, column pipe from bore well with the help of chain pully block including transportation to workshop for repair and lowering of same pump in bore well after repair including replacement of rusted nuts bolts, rubber gasket complete all as specifeid and as directed.
Devlopment of bore well with air compressor 210-310 CFM with pressure line at 4 to 6 Kg/Sqcm complete all as specified and directed.
Devlopment of bore well with air compressor 310 -450 CFM with pressure line at 8 to 10 Kg/Sqcm complete all as specified and directed.
Supply and fixing and water proof submersible cable 3 core copper conductor, PVC insulated 1100 volts grade 2.5 Sqmm protected by means of metal clip alongwith the pump body and connected to pump motor through water tight sealing joints including taking out old unserviceable submersible cable complete all as specified and as directed.
All as per item No.89 but of size 4 Sqmm
Supplying and lowering of MS Coloumn Pipe heavy duty class 'C' including welding both ends MS flange (Length of Pipe 3 mtr long) of size 80 mm bore complete all as specified and directed.
Supplying and lowering of MS Coloumn Pipe heavy duty class 'C' including welding both ends MS flange (Length of Pipe 3 mtr long) of size 50 mm bore complete all as specified and directed.
S&F in replacement moulded case circuit breakers 3 pole 200 Amps having breaking capcity 36 KA at 415 volts complete all as specified and as directed.
S&F in replacement moulded case circuit breakers 4 pole 160 Amps having breaking capcity 36 KA at 415 volts complete all as specified and as directed.
S&F in replacement moulded case circuit breakers 3 pole 100 Amps having breaking capcity 16 KA at 415 volts complete all as specified and as directed.
S&F in replacement moulded case circuit breakers 3 pole 63 Amps having breaking capcity 16 KA at 415 volts complete all as specified and as directed.
S&F in replacement 3 pole power contactor ML-2, 32 Amps 415 volts, 50 HZ, suitable for fixing in existing panel complete all as specified and directed.
S&F in replacement 3 pole power contactor ML-1.5, 25 Amps 415 volts, 50 HZ suitable for fixing in existing panel complete all as specified and directed.
S&F in replacement 3 pole power contactor MNX-32, 32 Amps 415 volts, 50 HZ suitable for fixing in existing panel complete all as specified and directed.
S&F in replacement of fully automatic star - delta straters in sheet enclosure type ML-1.5 FASD complete all as specified and directed.
S&F in replacement of fully automatic star - delta straters in sheet enclosure type ML-2.0 FASD complete all as specified and directed.
S&F Submersible pump controller MUG-6 (5 HP - 7.5 HP DOL) or 3 seat enclosure with over load, short circuit, under current, unbalance, phase reversal, phase loss,locked rotar, eath fault, stall ,CB failure with fault record with date and time, having feature of fail safe operation, and over load characterstic complete all as specified and directed.
Supply and fixing in replacement of mild steel nuts, bolts & washers etc of any size complete all as specified and as directed.
Supply and fixing well cap suitable for 200/250/300 mm bore pipe consisting of two parts complete with welding and machinery work having provision of cut out for passing of column pipe and fabricated out of mild steel sheet 3.15 mm thick complete all as specified and as directed .
Supply and laying new XLPE UG armoured , heavy duty electric power cable with aluminium conductor, 1100 volts grade, of cross siectional area of fowwing sizes including taking down the unserviceable one and deposited to MES store yard.
4 core x 16 Sqmm
3.5 core x 50 Sqmm
M&L for dry river Sand for cable cushioning for under and above the cable including punning complete all as specified and directed.
Supply and fixing of sub Class 'B' brick laid across the cable above the sand cushioning for protection of cable complete all as specified and directed.
M&L for Straight through joints for LT underground cable including joint kits and labour complete for making joints suitable for aluminium conductor cables of size upto 35 Sqmm, 3.5/4 core
All as per item No. 107 here-in-before but of size 3.5 core 50 Sq mm to 95 Sqmm
Material and labour for PCC (1:4:8) type D-2 (using 40 mm graded stone) aggregate as in foundation, flooring sub base complete all as specified and as directed.
Material and labour for PCC (1:2:4) type B-I (with 20 mm graded aggregate) as in coping, grouting, finished even and smooth without using extra cement complete all as specified and as directed.
Material and labour for PCC (1:3:6) type C-I (with 20 mm graded aggregate) as in drain, finished even and smooth without using extra cement complete all as specified and as directed.
Drilling not less than 250 mm bore hole by DTH (Down the hole) method to any depth below the ground level in any kind of rock/soil upto 100 mtr deep including disposal of surplus soil to a distance not exc 50 mtr away complete all as specified and directed. Note : 1) In case of encountering rock prior to 30 mtr depth from ground level, the decision of the Garrison Engineer for reboring shall be final and binding. Specific order in writing shall be issued by Garrison Engineer for reboring and the quantities shall vary accordingly. 2) Cost of transportation of DTH plant is deemed to be included in the unit rate.
Supplying, lowering & fixing 200 mm nominal bore MS casing pipe, heavy duty as per IS-3589, minimum 6.0 mm thick ERW duly welded both sides socketed ends complete all as specified & directed.
Supplying, lowering & fixing 200 mm nominal bore MS casing pipe, heavy duty as per IS -3589 minimum 6.00 mm thick ERW slotted tube having 1000 slots of size 1.58 x 75 mm per mtr length uniformly distributed on surface, duly welded both side socketed ends complete all as specified and directed.
M&L for 200 mm internal dia UPVC casing pipe conforming to IS-4985-2000 with minimum pressure rating 8.0 Kg/Sqcm in 6.00 mtr length with male and female end with all necessary fittings including joiting and jointing materials all as specified and directed.
M&L for 200 mm internal dia UPVC slotted pipe conforming to IS-4985-2000 with minimum pressure rating of 8.0 Kg/Sqcm having 3mm slots in 2.44 to 3.85 mtr length with male and female end with all necessary fittings including joiting and jointing materials all as specified and directed.
M&L for 75 mm internal dia UPVC pipe conforming to IS-4985-2000 having with male and female end with all necessary fittings including joiting and jointing materials complete all as specified and directed.
M&L for 50 mm internal dia UPVC pipe conforming to IS-4985-2000 having with male and female end with all necessary fittings including joiting and jointing materials complete all as specified and directed.
Supply & fixing housing clamp for 50 mm bore pipe made out of flat MS 100x10 mm thick (length 60 cm) with 4 Nos 20 mm dia of suitable size of bolt, nuts, washers etc including drilling holes of suitable sizes and painting 2 coats of synthetic enamel paints over a coat of red oxide primer complete all as specified and directed.
Supply and fixing in replacement, installation, testing and commissioning of feeder pillar box ,outdoor type cubical shape,three phase, 4 wire, Al bus bar for phases and neutral made out of CRCA sheet 3.15 mm thick ,factory fabricated , CPRI approved , powder coated ,dust and vermin proof , provn for ventilation , angle iron frame and four legs of 50x50x6mm thick angle iron ,2 ft long grouted on PCC foundation of height not less than 30 cm from the ground level , grouting properly and of suitable size to accommodate the items mentioned below and having separate compartment /chambers for cable gallery busbar ,switch gear etc all as specified and comprising of following including necessary cable connections to the MCCBs, voltmeter, Ammeter and cable lugs etc complete all as specified and directed.
M&L for pea gravels of size 3mm to 6mm around casing/ housing complete all as specified and directed.
Supply and filling coarse sand in bottom of recharge chamber 1.5 to 2mm size, all as per existing at site complete all as specified and directed.
Taking out old/existing coarse aggregate of any size, washing it high pressure water pressure at site and relaying to its original position for easy perculation of rain water pit into ground complete all as specified and directed.
Supply and filling/topping up coarse aggregate 63mm as screening material in rain water pit complete all as specified and direcetd.
Demolition of brickwork or stone/Boulder masonry built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and precast concrete articles etc complete all as specified and as directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6M mean radius built in cement mortar 1:4 complete all as specified and as directed.
M&L for brick work in CM 1:4 using old bricks obtained from dismantling from item No 125 here-in-before complete all as specified and as directed.
M&L for 10mm thick cement plaster on fair faces of brick work or concrete surfaces in cement plaster 1:4 complete all as specified and direceted.
M&L for 15mm thick cement plaster on other than fair faces of brick work or concrete surfaces in cement plaster 1:4 complete all as specified and direceted.
De-silting of existing drain of size exc 0.30x0.30 mtr but n.exc.0.75x0.75 mtr and removal of clag/mud, vegetation, garbage, dry leafs etc and removing the same from site to a distance exc. 250mtr but n.exc.500 mtr and depositing complete all as specified and directed.
Labour for cutting bushes, shrubs and tree of girth not exc. 30 cm and removing/depositing the same complete all as specified and directed.
Removing old/broken PCC/RCC covers of any size and M&L for SFRC perforated cover heavy duty 100mm thick set in CM 1:4 complete all as specified and directed. Note: Covers shall be measured in complete and no deduction shall be made for perforation.
M&L for pre cast RCC 1:2:4 type B-0 as in cover slab inclusive of form work and set in cement mortar 1:4 complete all as specified and direcetd.
Dismantlling old/broken PCC/RCC covers of any size and any type complete all as specified and as diirected.
M&L for Framed work such as in grills, grating, angle Iron, MS strip, MS Sheet upto 3 mm, etc with ends of bars, shoulder or revetted or forged into spike frame,guard bars barred iron door,railing frame or similar work and locking arrangement including cutting, drilling , welding and painting with two coat of synthetic enameled paint over a coat of redoxide primer after preparation of surface complete all as specified and directed.
M&L Preparation of new/old plastered surfaces of walls & applying two coats of APEX weather coat paint over a coat of white primer complete all as specified and directed.
M&L for sign board made out of 2mm thick in Radium Paint sheet steel of size 120x90 cms painted both side with over a coat of red oxide primer and writing both side "Rain water harvesting pit No/Bore well No, GE (U) water supply" with white paint over approved painted back ground and embedded in PCC 1:3:6 type C-2 of 30cmx30cm x 30 cm at 2 mtr height above ground level complete with angle Iron of size 50x50x5 mm including taking down old unsv sign board complete all as specified and directed.
Supply and filling/topping up broken boulders 5mm to 25mm as screening material complete all as specified and as directed.
Excavation in over areas not exc. 3 m wide and not exc. 3 m in depth including getting out in soft/loose/ Hard soil complete all as specified and directed.
Supply and filling/topping up coarse aggregate 40 mm as screening material complete all as specified and direcetd.
Supply and filling/topping up coarse aggregate 20 mm as screening material complete all as specified and direcetd.
M& L for servicing of existing water meter waltman type of size 600 mm bore including diconnecting and making connection with flanged ends, with rubber gasket sheet and nut and bolts , replacement of unserviceable parts with and including making way to site complete all as specified and direcetd. Note: All T & P (JCB/Hydra) required for completion of work will be provided by contractor.
M& L for servicing of high must light pole 15 mtr height suitable upto 8 nos lantern symmertrically fittings and including repair/ replacement of steel wire rope of 6mm dia, mounting arm, pully assembly, aviation light and all T&P (JCB/Hydra) required at site complete all as specified and directed.
NOTE :- If the contractor fails to repair the motor and pump within the seven days given to him the same will be got repaired through other agency by calling spot quotation at his risk and cost. This shall be in addition to penalty as mentioned in Particular Specification. The decision of accepting officer in this regard shall be final concluding and binding to the contractor.
Rahul Enterprises (BID ID -3490260)
M P TYAGI ENGINEERS AND CONTRACTORS (BID ID -3487266)
Sumit Enterprises (BID ID -3489457)
Ridhi engineers and builders (BID ID -3490586)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
BOQ_827434.xls
BOQ • 0.70 MB
D35TP.pdf
Tender Documents • 1.15 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .