Executive Engineer (Elect)
T.E. Building Kidwai Bhawan MTNL, New Delhi
Mending and Restoration of faulty addressable Fire detection, fire alarm system and provision of Vesda system and associated works at TE bldg Old Minto Road, New Delhi.
2023_MTNL_747167_1
EE(E)KBN/2022-23/31-03-23/135
Open Tender
Electrical Works
Item Rate
7 days
Kidwai Bhawan
Please refer Tender documents.
9 documents required · 9 mandatory
₹590
MTNL Delhi
₹31,144
18 Apr 2023
31 Mar 2023
6 Apr 2023
31 Mar 2023
5 Apr 2023
31 Mar 2023
Amount
Mending & restortaion of Siemens (Firefinder)make addressable Fire panel 10 loop wall mounted type control panel , the job include tracing the fault and troubles in each loop and removing the fault bythe Siemens trained engineer / technician. The job inlcdue only work manship , the cost of material to rectify the fault shall be paid extra. etc., and making the panel fully functional complete as reqd.
Mending & restoration of Siemens (Mxl) make addressable Fire panel 04 loop wall mounted type control panel , the job include tracing the fault and troubles in each loop and removing the fault by the Siemens trained engineer / technician. The job include only work man ship , the cost of material to rectify the fault shall be paid extra. etc., and making the panel fully functional complete as reqd.
Mending & restoration of Faulty Honeywell Morley make addressable 2 loop panel the job include tracing the fault and troubles in each loop and removing the fault bythe Siemens trained engineer / technician. The job include only work man ship , the cost of material to rectify the fault shall be paid extra. etc., and making the panel fully functional complete as reqd.
Replacement of following Siemens make faulty equipment , by removing the faulty equipment and programming the new device with the Siemens programmer and install the same and configuring the same in Fire panel to make the Addressable fire alarm panel fully functional a) Addressable Smoke cum heat detector
b) Addressable Smoke detector
c) Addressable Heat Detector
d) Manual call box
e) Sounder
f) Control Module
g) Monitor Module
h) Response Indicator
i) Loop card
j) 2x12V 26 ah SMF battery
Replacement of following Honeywell Morley make faulty equipment , by removing the faulty equipment and programming the new device with the Siemens programmer and install the same and configuring the same in Fire panel to make the Addressable fire alarm panel fully functional ( TRAI section) a) Addressable Smoke cum heat detector
b) Addressable Smoke detector
c) Addressable Heat Detector
d) Manual call box
e) Sounder
f) Control Module
g) Response Indicator
b) Repairing of PA ampliFire
c) Replacement of faulty wall mount speakers
d) Replacement of faulty ceiling mount speakers
Providing, testing and commissioning of Laser-Based Absolute Smoke Detection VESDA system Coverage up to 250 m2 , Single pipe inlet, Maximum pipe lengths: 1 x 25 m (Max. 12 holes , 2 x 21 m (Max. 06 holes per branch), Adjustable Wide sensitivity Range - 0.025 to 20% obs/m, 4 alarm levels ; High efficiency aspirator; Clean air barrier optics protection for the maintenance free sealed autocleaning laser based detection chamber, Easy to replace dual stage filter; 3Nos of inbuilt potential free relay outputs (Pre Alarm, Alarm & fault) Ultrasonic Airflow Sensing, Dual Stage Air Filtration, Instant Recognition Display, Event log up to 10000 events, Multiple Event Logging in separate logs etc. complete as required. (UL listed/ FM/LPCB/VdS/EN 54 approved). (Make: M/S Xtralis VEDSA VLF 250 )
Supply, installation, testing and commissioning of Power Supply Input voltage of 230V AC, output voltage of 24 V DC (nominal), 1.5 Amp DC (minimum) in a suitable size enclosure along with 2 nos. 12 V, 07 AH sealed maintenance free battery etc. complete as required .
Supply & installation of Trunk Adaptor for capillary points suitable for VESDA system etc. complete as required.
Supply & installation of Capillary Sampling Connector for Capillary tubes suitable for VESDA system etc. complete as required.
Supply and installation of Capillary tube for sample points (5.2mm ID 8mm OD per metre) suitable for VESDA system etc. complete as required.
Supplying and installation of sampling point for capillary tube end suitable for VESDA system etc. complete as required.
Supply & installation of sampling point label (RED) suitable for VESDA system etc. complete as required.
Supplying & Laying of U-PVC/C-PVC smooth bore aspiration tube of size (21mm Internal Dia and 25mm external dia) suitable for VESDA system with all accessories such as bends, tees, junction fittings including cutting, threading, drilling holes on surface, special jointing, fixing with clamps/clips etc. complete as required. (Astral , Supreme or Similar Superior make)
Replacement of Faulty LED lit laser etched exit signage’s made out of acrylic sheet ,with battery backup complete as required a) Single sided
b) Double sided
Replacement of following size MS C class pipe by cutting the wear out rusted pipe and fixing the new pipe with accessories complete as required a) MS pipe C class 150 mm dia
b) MS pipe C class 100 mm dia
c) MS pipe C class 80 mm dia
d) MS Pipe 50 mm dia
e) MS pipe 25 mm dia
Checking the existing MS pipe line riser in the building for any leakage and repairing the leaked pipe and testing the same complete as required
Servicing of existing main 2280LPM fire/spinkler pump, dismantling and cleaning of impellor, refixing the impellor, refixing the pump at site, greasing the existing bearings, refixing the pump with the base frame and shaft along with coupling, making coneection with the suction and delivery line, testing etc. complete as reqd.
Servicing of existing 100/150GS1 pump of 88 Mtr Head, diesel fire pump of Mather & Platt Make, dismantling and cleaning of impellor, refixing the impellor, refixing the pump at site, greasing the existing bearings, refixing the pump with the base frame and shaft along with coupling, making coneection with the suction and delivery line, testing etc. complete as reqd.
Dismantling of existing jockey fire pump, removing the pump from the rubber coupling and steel shaft, removing the motor from the pump, providing suitaable size new rubber coupling, refixing the shaft, motor and pump, tightening all nuts and bolts, making alignment, testing etc. as reqd.
Replacement of following size faulty valves and accessories complete with nut bolts etc a) Butterfly valve 150 mm dia
b) Non return valve 150 mm dia
c) Butterfly valve 100 mm dia
d) Non return valve 100 mm dia
e) Ball valve 40 mm Dia
Replacement of following FF accessories etc. complete as required. A) Stainless steel Hydrant valve coupling for double headed & single headed hydrant valve
b) Nozzle for Hose reel
c) Coupling pipe of Hose reel
d) 100m size pressure gauge with accessories
e) Pressure switch
S/F of RRL hose pipe 63mm dia 15 mtr long with SS male and female couplings, with GI binding, ISI MARKED etc. as reqd..(Make- Life guard/Agni/OMEX/Safex)
Replacement of wear out hose box with new hose box made out of 18 swg MS sheet suitable for 2nos 15 mtr RRL hose pipe & branch pipe
Repairing of rusted air vessel & repainting of the same as required
Providing and Fixing the SS Branch pipe i/c connection etc. complete as required.
Repairing the Internal Hose box and refixing the same
Essential overhauling and retrieve of Existing Fire fighting electrical panel, including, replacement of faulty parts like lamps/relays/contactors/ internal wiring (if required), checking connections and testing of Auto/manual operation of pupms as per fire guide lines including inter locking of jockey and main pump etc. as reqd.
Replacement of 2 x12 V, 150 ah battery for diesel pump i/c connection testing etc. complete as required.
Replacement of rusted out flange of size from 100 mm to 150 mm size i/c cutting welding connection complete with and nut bolts etc complete as required.
Providing Base/ support for existing Fire ring main pipe line fixed along the wall ,supporting base should be masonry structure of size 250x250 mm and of suitable height made out of brick & mortar complete as required
Painting of existing Fire ring main pipe line with a coat of PO red colour paint complete with cleaning the rust / dust etc and painting the same a) 100-150 mm dia pipe
b) 50--80 mm dia pipe
c) 25- 50 mm dia pipe
Removing the empty of following capacity dry chemical ( DCP )powder based Fire extinguishers from the site and taking it to the refilling plant and Refilling the same with DCP powder and required gas include checking the nozzle, valve testing & refixing the same at site complete as required a) 5 KG DCP type
b) 10 KG DCP type
Removing the empty of following capacity ABC type Fire extinguishers from the site and taking it to the refilling plant and Refilling the same with Mono Amonium phosphate powder and required gas include checking the nozzle, valve testing & refixiing the same at site complete as required a) 2 KG ABC type
b) 5 KG ABC type
Removing the empty following capacity Foam type Fire extinguishers from the site and taking it to the refilling plant and Refilling the same with foam concentrate and required GAS include checking the nozzle, valve & hydraulic testing & refixing the same complete as required a) 9 ltr capacity Foam type
b) 50 ltr capacity foam type trolley
Removing the empty following capacity water CO2 type Fire extinguishers from the site and taking it to the refilling plant and Refilling the same with required CO2 GAS include checking the nozzle, valve testing & refixing the same complete as required a) 9 ltr capacity WCO2 type
Removing the empty following capacity CO2 type Fire extinguishers from the site and taking it to the refilling plant and Refilling the same with required CO2 GAS include checking the nozzle, valve and hydrolic testing & refixing the same complete as required a) 4.5 Kg capacity CO2 type
b) 6/6.8 Kg capacity CO2 type
c) 9/10 Kg capacity CO2 type
Replacement of the following faulty component of the Fire extinguishers with new component / accessories complete as required a) Discharge Hose pipe with horn for CO2 type Fire extinguishers
b) Discharge Hose pipe for ABC/DCP type Fire extinguishers
c) Valve for CO2 type Fire extinguishers
d) Valve for ABC/ DCP/ Foam type Fire extinguishers
e) Pressure Gauge for ABC/DCP type fire extinguishers
Repainting the rusted portable type fire extinguishers with two coats PO red color complete as required.
Removing the empty Fire extinguishers from the site and taking it to the refilling plant and getting the cylinder hydraulic tested for high pressure as per Gas cylinder Rule 1981 and returning the rejected cylinder back to site in charge complete as required
Supply & fixing the stickers on painted Fire extinguishers of required type giving details of type of fire extinguishers and the method to use the Fire extinguishers complete as required
Less credit for dismantled material
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .