| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.0 LAccepted-AOC PR CDA SC PUNE 01 THROUGH AO GE DEHU ROAD | L1 | Accepted-AOC REASONABLE | |
| 2 | L2₹18.7 L+₹12,880 (0.69%)Rejected-Finance | L2 | Rejected-Finance HIGH RATE | |
| 3 | L3₹20.2 L+₹1.6 L (8.45%)Rejected-Finance | L3 | Rejected-Finance HIGH RATE | |
| 4 | L4₹45.6 L+₹27.0 L (145.1%)Rejected-Finance | L4 | Rejected-Finance HIGH RATE | |
| 5 | Rejected-Technical | - | Rejected-Technical REJECTED DUE TO REMARKS NO AVAIBALE IN WEL QE SEP 2023 CIRCULATED BY HE CEPZ PUNE |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
25 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI PRAVEEN KUMAR, IDSE
GE KHADAKWASLA, NDA KHADAKWASLA, PUNE-23
REPAIR / MAINT AND CLEANING OF SEWAGE LINES AT NCOS JCOS MD ACCN AND CERTAIN PUBLIC BLDGS AT ZONE C AREA AT NDA KHADAKWASLA
2023_MES_634599_1
8786/E8
Open Tender
Civil Works
Item Rate
270 days
GE KHADAKWASLA
AS PER TENDER DOCUMENT
9 documents required · 9 mandatory
₹500
GE KHADAKWASLA
₹70,000
Yes
27 Feb 2024
27 Dec 2023
30 Jan 2024
27 Dec 2023
25 Jan 2024
11 Jan 2024
27 Dec 2023 - 10 Jan 2024
Amount
Excavation in trenches, n.exc 1.5M wide and not exceeding 1.5M depth for foundation etc or for shaft, wells, cesspits, manhole, pier holes etc n.exc 10 Sqm on plan and n.exc 1.5M in depth and getting out in soft/loose soil complete all as specified & directed.
Excavation in trenches, n.exc 1.5M wide but depth exceeding 1.5M and n.exc 3.00M for foundation etc or for shaft, wells, cesspits, manhole, pier holes etc n.exc 10 Sqm on plan and n.exc 3.00M in depth and getting out in soft/loose soil complete all as specified & directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm complete all as specified & directed.
Removing excavated material to a distance exc 50M but n.exc 150M and depositing where directed at a level n.exc 1.5M above the starting point complete all as specified & directed.
Demolition & breaking up drain pipes (salt glazed stone ware, AC or reinforced concrete) set in cement mortar including bed concrete internal dia of pipe 150mm and removal of demolished materail out of MoD land complete all as specified & directed.
Ditto all as per item No 5 above but internal dia 200mm.
Ditto all as per item No 5 above but internal dia 250mm.
Cleaning of manhole chamber of depth not exceeding 1.00 metre each, mechanically, removing muck/sludge/silt/mud, liquid etc under any position including foul condition and cleaning the inlets and outlets etc washing and well flushing of the manhole with water, placing the cover back in position and disposing off the sludge /debris out of MD land complete all as specified & directed. Note: The sludge to be disposed off in sealed tins or sludge removal tankers and the same is deemed to include in the rate quoted.
Ditto all as per item No 8 above but depth of manhole exc 1 Mtr and n exc 3 Mtr etc complete all as specified & directed.
Cleaning of floor trap (of any type/size), by taking out accumulated silt, mud etc and removing the same at a distance not exceeding 50 metre (where directed), washing and well flushing of the floor trap with water complete all as specified & directed.
Cleaning of blocked water closet (of any type/pattern) including connected CI pipe line (of any bore) upto 1st manhole complete all as specified & directed.
Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator,supervising engineer etc. for cleaning and partial desilting of manholes and dechocking of sewer lines. Dechocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 150mm dia upto 300mm dia for all depth. Note for item srl No.8 to 12 :(i) The rates quoted in the below from Ser item No. 08 to 12 includes cost of T&P etc complete and the work will be carried out on complaint basic, day to day maintainance. (ii) Minimum two persons shall be deployed by contractor and they shall be present on all working days for attending the complaints of Sewage. (iii) The contractor/ rep of the contractor will collect the complaint slips from B&R-I Zone C complaint cell in GE Khadakwasla office by 9.00AM and submit the complaints reports of the same each day by 1730hrs after rectification, failing which penal recovery @ Rs. 100.00 per complaint will be recovered from contractor's dues. (iv) Urgent manpower for removal of blockage of any type, may be required to be provided by the contractor in day or night (on sunday or holiday) on a short notice. If the contractor fails to provide manpower for the specific work, manpower for the same work will be hired from any other source for that urgent job by the deparment & shall be paid in full by the contractor without any extra cost to the deparment complete all as specified & directed.
Material and labour for lowering and laying 150mm bore Reinforced Cement Concrete pipes, class NP3,spigot and socket ended pipes (IS : 458-2003 marked) with and including rollon rubber ring gasket (Conforming to IS : 5382-1967 Type -I) as specified in particular specification clause No.12.14 alinging and jointed complete all as specified & directed.
Material and labour for lowering and laying 200mm bore Reinforced Cement Concrete pipes, class NP3,spigot and socket ended pipes (IS : 458-2003 marked) with and including rollon rubber ring gasket (Conforming to IS : 5382-1967 Type -I) as specified in particular specification clause No.12.14 aligning and jointed complete all as specified & directed.
Material and labour for lowiering and laying 250mm bore Reinforced Cement Concrete pipes, class NP3,spigot and socket ended pipes (IS : 458-2003 marked) with and including rollon rubber ring gasket (Conforming to IS : 5382-1967 Type -I) as specified in particular specification clause No.12.14 aligning and jointed complete all as specified & directed.
Material and labour for supplying,Jointing & Laying 150mm bore of sewer line Double wall corrugated HDPE pipe (DWC HDPE) of stiffness class designation SN 8(conforming to I. S. 16098 (Part 2) :2013) ( Spigot and Socket ended pipe) at site with base of 150mm thick PCC 1:3:6, type C-2, using 40mm graded stone aggregate including jointing with rubber gasket,by jointing jack method and making connection to old or new manholes (including dismantling and making good the manhole wall) filling and compaction of trenches with appropriate materials etc and duly tested the pipe line as per manufacturer instruction after laying of pipe line complete all as specified & directed. Note : (i) PCC shall be measured and paid separately. (ii) Contractor shall submit manufacturer test certificate of DWC pipe
Material and labour for supplying,Jointing & Laying 200mm bore of sewer line Double wall corrugated HDPE pipe (DWC HDPE) of stiffness class designation SN 8(conforming to I. S. 16098 (Part 2) :2013) ( Spigot and Socket ended pipe) at site with base of 150mm thick PCC 1:3:6, type C-2, using 40mm graded stone aggregate including jointing with rubber gasket,by jointing jack method and making connection to old or new manholes (including dismantling and making good the manhole wall) filling and compaction of trenches with appropriate materials etc and duly tested the pipe line as per manufacturer instruction after laying of pipe line complete all as specified & directed. Note : (i) PCC shall be measured and paid separately. (ii) Contractor shall submit manufacturer test certificate of DWC pipe
Material and labour for supplying,Jointing & Laying 250mm bore of sewer line Double wall corrugated HDPE pipe (DWC HDPE) of stiffness class designation SN 8(conforming to I. S. 16098 (Part 2) :2013) ( Spigot and Socket ended pipe) at site with base of 150mm thick PCC 1:3:6, type C-2, using 40mm graded stone aggregate including jointing with rubber gasket,by jointing jack method and making connection to old or new manholes (including dismantling and making good the manhole wall) filling and compaction of trenches with appropriate materials etc and duly tested the pipe line as per manufacturer instruction after laying of pipe line complete all as specified & directed. Note : (i) PCC shall be measured and paid separately. (ii) Contractor shall submit manufacturer test certificate of DWC pipe
M&L for PCC 1:3:6, type C-2, using 40mm size graded stone aggregate as concrete bed to drain pipes of 150mm bore including packing under and haunching against the sides of pipes, after they are laid and tested complete all as specified & directed.
M&L for PCC 1:3:6, type C-2, using 40mm size graded stone aggregate as concrete bed to drain pipes of 200mm bore including packing under and haunching against the sides of pipes, after they are laid and tested complete all as specified & directed.
M&L for PCC 1:3:6, type C-2, using 40mm size graded stone aggregate as concrete bed to drain pipes of 250mm bore including packing under and haunching against the sides of pipes, after they are laid and tested complete all as specified & directed.
Material and labour for providing, fixing, Jointing, testing and commissioning pre-fabricated PP/PE Manholes of approved Make,complying to relevant IS (in absence BS/ASTM/equivalen)EN 13598-2 standards,depth upto 1000mm and dia 1000mm including manhole cover,over 150mm thick base of cement concrete 1:3:6 using 40mm grading stone aggregate ,PCC shall have 150mm extra width all around the base of manhole with 150mm thick top ring of cast -in-situ cement concrete 1:3:6 consisting of chamber base ,risers,shafts necessary arrangement to take the frame and cover including all required accessories like blanking/socket pluges eccentric reducers,jointing with rings/sealant,telescopic adapter (if required) to raise the height above ground making necessary inlet/outlet connections to base ,in situ adapters for providing necessary inlets as per requirement all complete as per specifications and manufacturers instructions and specifications complete all as specified & directed. Note : (i) PCC shall be measured and paid separately. (ii) Contractor shall submit manufacturer test certificate of PE Manhole
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified & directed.
M&L for plain cement concrete 1:3:6 type C-2, using 40mm size graded stone aggregate as in foundation and bed concretes, mass concrete etc complete all as specified & directed.
Demolition of brick work or stone buillder built in cement mortar of any description complete all as specified & directed.
M&L for precast cement concrete block walling exc. 10 cm width with solid block C-1 grade design mix and setting in cement mortar (1:6) complete all as specified & directed.
Taking down cement plaster on brick or concrete wall surfaces etc including raking out joints, hacking for key , scrubbing down with water etc. complete all as specified & directed.
M&L for rendering 15mm thick in CM 1:4 on brick/ concrete surfaces of walls including floating coat using water proofing compound as per Manufacturer's Instructions complete all as specified & directed. Note : WPC shall be measured and paid separately.
Supply only water proofing compound as per relevant IS complete all as specified & directed.
M&L PCC 1:2:4 type B1 using 20mm graded aggregate as in coping and benching in manholes including necessary form work and finishing the exposed surface concrete even and smooth using extra cement complete all as specified & directed.
M&L for Extra for forming for finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms moulds mitred stopped etc complete all as specified & directed.
M&L for Cutting into existing manholes for connecting new drains of dia 150 mm, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified & directed.
Supply and Fixing in repairs, SFRC (Steel Fibre Reinforced Concrete) Manhole cover slabs of size 450mm x 900mm x 100mm thick with frame set in cement mortar 1:4 complete all as specified & directed. Note: Contractor will provide manufacturer test certificate of SFRC cover & frame
Supply and Fixing in repairs, SFRC (Steel Fibre Reinforced Concrete) Manhole cover slabs of size 600mm x 900mm x 100mm thick with frame set in cement mortar 1:4complete all as specified & directed. Note: Contractor will provide manufacturer test certificate of SFRC cover & frame
Supply and Fixing in repairs, SFRC (Steel Fibre Reinforced Concrete) Manhole cover slabs of size 600mm x 600mm x 100mm thick with frame set in cement mortar 1:4 complete all as specified & directed. Note: Contractor will provide manufacturer test certificate of SFRC cover & frame
Supply and Fixing in repairs, SFRC (Steel Fibre Reinforced Concrete) Manhole cover slabs of size 300mm x 300mm x 100mm thick with frame set in cement mortar 1:4 complete all as specified & directed. Note: Contractor will provide manufacturer test certificate of SFRC cover & frame
Taking down rain water pipes (any size or pattern) including all fitting heads, shoes, bends swan necks,etc complete all as specified & directed.
S&F for 75mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints fixed to wall or floor etc using synthetic rubber adhesive cement solvent complete all as specified & directed.
S&F for 110mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints fixed to wall or floor etc using synthetic rubber adhesive cement solvent complete all as specified & directed.
S&F for 75mm dia PVC (SWR) bends any radius complete all as specified & directed.
S&F for 75mm dia PVC (SWR) junction single(single T) complete all as specified & directed.
S&F for 75mm dia PVC (SWR) branch piece single(single Y) equal or unequal complete all as specified & directed.
S&F for 75mm dia PVC (SWR) vent cowl complete all as specified & directed.
S&F for 110mm dia PVC (SWR) bends any radius complete all as specified & directed.
S&F for 110mm dia PVC (SWR) junction single (single T) complete all as specified & directed.
S&F for 110mm dia PVC (SWR) vent cowl complete complete all as specified & directed.
M&L for 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified & directed.
S&F in repair vitreous China squatting pan, ‘Orissa’ pattern, size 630 x 450 mm white, with integral foot rests (excluding flushing cistern and flush pipe) connection to trap and squatting pan including P' trap set in and including concrete etc. complete including making good to floor complete all as specified & directed.
S&F in repair PVC flushing cistern of 10 ltrs capacity valveless, syphonic action type, low level, white with inlet, ball valve, float and handle including brackets and PVC flush pipe of 32 mm bore and connection to pipes etc complete all as specified & directed.
S&F in repairs PVC connections 15mm size with PTMT nuts of length 600 mm complete all as specified & directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premices complete all as specified & directed.
Material and Labour for Joint free non-skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tiles t exceeding 0.11 Sqm but n exc 0.18 Sqm, (400x400x7 to mm thick), in flooring etc set and and incl 15mm thick screed bed or bedding layer in CM (1:4) complete all as specified & directed.
Material and Labour for coloured Glazed ceramic tiles as in vertical surface of Size 350x 250 x7mm /450x350x7 mm set and jointed in neat cement slurry laid over 10 mm thick cement rendering in cement mortar 1:6 and pointed in white or colour cement to match the tile complete all as specified & directed.
S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including P-trap or S-trap, seat cover, (Standard) with PVC bolts, nuts, PVC bend complete all as specified & directed.
DARSHAN ENTERPRISES
ELIEYAS TRADERS
M/s. Shige Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .