Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance BAMNA HATHRAS | HATHRAS | HATHRAS | UTTAR PRADESH | Admitted-Finance |
| 2 | Admitted-Finance NAGLA SADAK HATHRAS | HATHRAS | HATHRAS | UTTAR PRADESH | Admitted-Finance |
| 3 | Admitted-Finance NAJARPUR SASNI HATHRAS UTTAR PRADESH 204101 | HATHRAS | HATHRAS | UTTAR PRADESH | 204101 | Admitted-Finance |
| 4 | Not Admitted-Fee/PreQual/Technical MAHESHWARI COLONY IGLAS ADDA HATHRAS | HATHRAS | HATHRAS | UTTAR PRADESH | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
20 Sept 2023, 12:00 pmClosed
se
edc hathras
Semi Turnkey
2023_DVVNL_837633_1
EDCH-65/2023-24
Open Tender
Electrical Works
Item Rate
180 days
Hathras
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
DVVNL WEBSITE
₹20,000
10 Oct 2023
13 Sept 2023
20 Sept 2023
13 Sept 2023
20 Sept 2023
13 Sept 2023
Amount
Supply of Following Matarial as per relevent ISS
Barbed wire
Danger Board With Clamp
MS Channel 125*65*1300 MM
Stone pad
Tee Off Channal
Top Channal
Nut Bolt With Washer
Holding Clamp for Top & Dropper, TPMO etc
Lt Piller Box
T/F Base Angle 75*75*6*2028 mm with Clamp Nut & Bolt
33 kv Bus Isolator
33 kv Post Isolator
5 MVA Transformer Bus Complete
33 Kv Lightening arrestor
90 lbs rail Pieces (44.64 kh/m)
Dropper Channal
LT Incoming Pannel with meter equipments
11 KV Fuse Set
AL LUG 400 sqmm
Scope of work
Safe Carriage of following material from Electricty store center Hts to Pit site of work through the Kacha and Pakka road including loading and unloading at the respective ends including the cost of arrangement of labour, T&P, etc. which required for proper completion of work.(Distance 00-50 Kms.)
8.5 /9 Mtr. long PCC Poles.
9/11/13 Mtr Long STP Poles.
11 KV X-Arms, weasal conductor, G.I wire,Disc Insulators, Pin insulators, clamps Abc Bunch and other required line material, if any.
Incoming VCB 600/300/5 AMP 350 MVA
Outgoing VCB 200/100/5 AMP 350 MVA
11 kv XLPE Cable (3*300+3*120sqmm)
Safe Carriage of following from Electricty Store center Hathras to Pit Site of Work through the Kacha and Pakka road loading and unloading at the respective ends including the cost of arrangement of labour, T&P, etc. which required for proper completion of work.(Distance 00-70 Kms.)
16 KVA T/F
25/63/100 KVA T/F
Errection of following Poles with grouting including Cutting of kharanja/mettalic road/concrete portion while digging pit & complete H.T./L.T. fittings as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.
PCC poles 8.5/9 Mtr.
Double pole complet fitting
Fixing/ Errection of LT Incoming Pannel with meter equipments with Grouting as per respoo manual all cost of labor, material and T&P which required for completion of work
Fixing/ Errection of VCB Pannel with Grouting as per respoo manual all cost of labor, material and T&P which required for completion of work
Errection and grouting of stays as per RESPO Norms and as per direction of supervising engineer. Grouting material i.e. cement, sand, brick ballast/stone ballast etc. shall be arranged by the contractor at his own cost.
Fixing of earthing rod as per RESPO Norms and as per direction of supervising engineer.
Laying, sagging and stringing and jumpering / binding etc. of new & old ACSR Weasal conductor / GI in 11 KV / LT lines as per RESPO manual and as per direction of supervising engineer.
ACSR Weasal conductor
Safe Dismenteling of old and used following T/F from Double Pole with opening of all HT/LT Jumpers, all works which required for dismentling of T/F and carriage it up to Store Hathras/ J.E Store all cost of labour and T&P which required for completion of work
10/16 KVA T/F
25/63/100 KVA T/F
Resagging of Existing line by stringing and jumpering / binding etc. of new & old ACSR Weasal conductor / GI in 11 KV / LT lines as per RESPO manual and as per direction of supervising engineer.
ACSR Weasal/Dog conductor
Dismentalling of old and used VCB from switchyard and carriage it up to Store Center Hathras/ J.E Store Including all Cost of Labour and T&P Which required for completion of work distance range 0-50 Km
Installation of 250/400 KVA T/F on newly/Old constructed Plinth in proper alignment direction & making HT/LT connection all Cost of labour and T&P which required for completion of work
Installation of following T/F on newly constructed double pole in proper alignment direction & making HT/LT connection.
16 KVA T/F
25/63/100 KVA T/F
Fixing of Following Accessirious
11 KV TPMO
11 Kv Fuse Set
Danger Board/Plate
Construction of plinth of size 5' * 5 * 4' above ground level one ft below the ground level of 9" After Exavation of 4 "earth brick ballast shall be provided and rammering will be done properly After ballast shall be provided and rammering will be done properly After that a retaining wall 9"width by fist class brick in ratio 1:4 of cement & sand shall be made . The earth shall be filled up to one ft.below the top of the plinth After this brick ballast shall be provided upto 6"from the earth level and proper rammering shall be done one No. jall of 12 mm MS tor shall be fixed in the hollow of plinth and one ft. thick RCC in ratio of cement sand & stone ballast shall be laid on the top of the plinth. The 12 mm thick plastering shall be done all round the plinth in 1:4 ratio of cement and sand.
Pipe earthing of 250/400 KVA medium Power Transformers
Net Fencing Shall be 1150*1200 mm made of 35*35 mm MS Angle covered by expended netal 14 SWG up to full Height 1200 mm duly steftened by MS flat by an 8 SWG dia bolt & nut
Re Guarding / Guarding of 11 KV line by laying, stringing, sagging and binding of 2 Nos. parallel GI wire 6 SWG after providing, fabrication and fixing of guarding angle and fabrication and fixing of X-guards (Tillis) of GI wire at distance of 3 Mtr.
Installation of extra ''T'' on the erected poles wherever required alongwith all fitting as per direction of supervising engineer including the cost of labour, T&P etc, required for proper completion of work. The "T" pole shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 including the cost of material.
Cutting, chopping, triming of tree branches to clear the line route to give 2 mtr. horizontal and vertical clearance to the line coming in the route of different feeders as per direction of supervising engineer
Structure for 33 KV Bus Isolator
Structure for 33 KV Post Isolator
Structure for 5 MVA T/F Bus Complete
Structure for 33 Kv Lightening arrestor
Fixing of 90 lbs rail pieces
Construction of Plinth and foundation Suitable for 5 MVA T/F above ground level one ft below the ground level of 9" After Exavation of 4 "earth brick ballast shall be provided and remaining will be done properly After ballast shall be provided a retaining wall 9"width by fist class brick in ratio 1:4 of cement & sand shall be made . The earth shall be filled up to one ft.below the top of the plinth After this brick ballast shall be provided upto 6"from the earth level and proper rammering shall be done one No. jall of 12 mm MS tor shall be fixed in the hollow of plinth and one ft. thick RCC in ratio of cement sand & stone ballast shall be laid on the top of the plinth. The 12 mm thick plastering shall be done all round the plinth in 1:4 ratio of cement and sand.
Making all H/T/ jumpers of installed New/Repaired 5 MVA T/f after Completion of Work
Earthing of 5 MVA power T/F (Body & Neutral)
Fixing of 33 KV VCB with Double T/F Control Pannel and CT 200/100/1A with Structure
Construction of plinth and foundation of VCB Pannel
Fixing and Installation of incoming and outgoing VCB pannel
Laying of 190 mtr XLPE Cable with making of cable box mounted with switch gare and T/F (Kit)
Fixing of cable jointing kit 120 sqmm
Laying of 4*2.5 sqmm and 2*2.5 sqmm control cable app 200 mtr
Earthing of Indoor equipments
Painting of indoor equipments with all cost of labour and material paint which required for completion of work
Back Cartage of Following Matarial
Acsr weasal Conductor scrap
R.N. ELECTRICAL WORKS
Bobby Electricals
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .