| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.3 LAccepted-AOC 10 11 PANDRI GOVIND NAGAR RAIPUR CHATTISHGARH 492001 | RAIPUR | CHHATTISGARH | 492001 | ₹49.3 L | L1 | Accepted-AOC Accept |
| 2 | L2₹50.8 L+₹1.6 L (3.19%)Rejected-Finance SAMBA LINE JUNGLIGHAT POST SRI VIJAYA PURAM 744103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | ₹50.8 L+₹1.6 L (3.19%) | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹51.7 L+₹2.4 L (4.97%)Rejected-Finance 290 NEW PLOT JAWAHAR NAGAR JAMMU JAMMU JAMMU KASHMIR 180005 | JAMMU | JAMMU AND KASHMIR | 180005 | ₹51.7 L+₹2.4 L (4.97%) | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹52.2 L+₹3.0 L (6.08%)Rejected-Finance | ₹52.2 L+₹3.0 L (6.08%) | L4 | Rejected-Finance Not being L1 |
| 5 | L5₹52.8 L+₹3.6 L (7.30%)Rejected-Finance | ₹52.8 L+₹3.6 L (7.30%) | L5 | Rejected-Finance Not being L1 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
24 Feb 2025, 6:55 pmClosed
GE, Minniebay, Sri Vijaya Puram
GE, Minniebay, Junglighat (PO), Sri Vijaya Puram -744103
8530- SPECIAL REPAIR TO TILING PLUMBING FALSE CEILING AND GALVALUME SHEET ROOFING BUILDING P-277/7 AND 8 AND BUILDING NO.P-279/7 AND 8 MD ACCN AT AJAY BAUGH UNDER GE MINNIE BAY, SRI VIJAYA PURAM
2025_MES_696304_1
8530/E8
Open Tender
Civil Works
Item Rate
180 days
GE, Minniebay, Sri Vijaya Puram
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
Yes
GE, Minniebay
₹98,000
Yes
19 Jul 2025
3 Feb 2025
25 Feb 2025
3 Feb 2025
24 Feb 2025
17 Feb 2025
Amount
Demoliton of cement concrete including tiles and mortar of any description and in any position not otherwise specifically provided for complete all as specified and as directed by Engineer in charge
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Engineer in charge
M&L for special treatment of sunken portion of WCs and Bath room as per following stages: Stage 1 :- Demolition of WC including lime concrete and cement concrete coba etc and preparing the surfaces of existing sunken portion of WCs or bath etc with wire brush to remove all loose dirt, oil grease etc . Stage 2:- Providing 10mm thick plaster in CM 1:4 with water proofing compound of approved make Stage 3:- Applying any water proofing compound of approved make(and allow to dry for 8 hours) under touch dry condition Stage 4:- Applying two coats of water proofing decorative elastomeric coating system of any water proofing compound of approved make(The surface after painting one coats shall be allowed to dry of 6 hours before next coats) all as per manufactutrer instruction Stage 5:-Again rendering 10mm thick in CM 1:4 mixed with any water proofing compound of approved make. Stage 6. All CI joints shall filled with mixture of cement fine sand and plaster seal any water proofing compound of approved make. Stage 7:- Making holes in wall and fixing 600mm long 20mm dia GI spout for draining the surplus water if any. Stage 8:- Making holes in wall and fixing 600mm long 20mm dia GI spout for draining the surplus water if any.
M & L for 25 mm thick, PCC 1:2:4, Type B-0, using 12.5mm graded aggregate as in sub base for flooring/levelling coarse etc complete all as specified and as directed by Engineer in charge
M&L for joint free Coloured 8 to 10mm thick vitrified tile, area of each tiles exc 0.18 Sqm but n exc 0.38 sqm in floors etc colour as approved set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM (1:4) complete all as specified and as directed by Engineer in charge
M&L for joint free Coloured 8 to 10mm thick vitrified tile, area of each tiles exc 0.18 Sqm but n exc 0.38 sqm in vertical surfaces etc colour as approved set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick backing plaster in CM (1:4) complete all as specified and as directed by Engineer in charge
M&L for Coloured Non-skid/matt finish Ceramic tiles edge to edge 7 to 8 mm thick of size exc. 0.11 sqm but n.exc 0.18 sqm area of each tiles in floor/ steps etc set and jointed in neat cement slurry and pointed in coloured cement to match as in floor over and including 15mm thick screed bed in CM (1:4) complete all as specified and as directed by Engineer in charge
M&L for Glazed Ceramic tiles 450x300x 8-10 mm thick in vertical surface set and jointed in neat cement slurry and pointed in white or colour cement to match over 10mm thick backing in cement mortar (1:3) complete all as specified and as directed by Engineer in charge
M & L for Chequered cement concrete tiles 30cm x 30cm x 8/10 mm thick, set, jointed and pointed in near cement slurry in floors/skirtings with grey cement and pigments and including screed bed 15mm thick CM 1:4 complete all as specified and as directed by Engineer in charge
Dismantling of stone slab of any description including cement mortar bedding but not backing, complete all as specified and as directed by Engineer-in-Charge.
M&L for granite (of any type) 16 to 20 mm thick machine cut fixed on slab,window cill etc , bedded & jointed with grey cement slurry & pointed with white cement with admixure of pigment to match the shade of granite stone including cutting, moulding & polishing over and including 20 mm thick screed in CM (1:4) complete all as specified and as directed by Engineer in charge
M & L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed by Engineer in charge
Demolition of precast concrete block walling built in Cement Mortar including all quoins arches pillars etc complete all as specified and as directed by Engineer in charge
M&L for precast cement concrete block masonry with solid block, exc 10cm in width in PCC type C-1, 1:3:6 (using 20mm graded stone aggregate) set in CM (1:6) complete all as specified and as directed by Engineer in charge
Taking down Cement Plaster of any description on brick or stone walls or concrete surfaces, ceiling including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed by Engineer in charge
M & L for rendering to concrete or block masonry surfaces or surfaces other than fair faces of brick surfaces, 10mm thick in Cement Mortar 1:6, surfaces finished even and smooth without using extra cement complete all as specified and as directed by Engineer in charge
M & L for rendering 5mm thick in CM (1:3) on ceiling surfaces finished even & smooth without using extra cement complete all as specified and as directed by Engineer in charge
M & L for rendering 5 mm thick in cement mortar 1:4 over a backing coat of 10mm thick in CM 1:6 (Total 15 mm thick) on concrete or brick masonry surfaces including mixing water proofing compound as per manufacurers instructions and finishing the top surface even and fair complete all as specified and as directed by Engineer in charge Note: Water proofing compound will be measured and paid separately.
M & L rendering 5mm thick in CM (1:3) on ceiling (external) surfaces finished even & smooth without using extra cement complete all as specified and as directed by Engineer in charge Note: Water proofing compound will be measured and paid separately.
Supply only Integral water proofing compound complete all as specified and as directed by Engineer in charge
M&L for complete removal and applying one coat of white cementitious putty on wall and making the surfaces smooth by rubbing with sand paper to achieve finished surface complete all as specified and as directed by Engineer in charge
M&L for preparing newly plastered surfaces of wall and applying two coats of oil emulsion distemper over a coat of primer complete all as specified and as directed by Engineer in charge
M&L for preparing newly plastered surfaces of ceiling and applying two coats of oil emulsion distemper over a coat of primer complete all as specified and as directed by Engineer in charge
M & L for complete removel of existing treatment on wall & finishing the surface & applying two coat of oil bound distemper along with primer complete all as specified and as directed by Engineer in charge
M & L for complete removel of existing treatment on ceiling and applying two coats of oil emulsion distemper over a coat of primer complete all as specified and as directed by Engineer in charge
M&L for preparation of old plastered or previously untreated wall surfaces including scraping, rubbing and washing etc and applying two coats of acrylic emulsion based premium quality matt finish exterior antifungal paint over a coat of primer all as directed and as per manufacturers instruction complete all as specified and as directed by Engineer in charge Make:- Apex Ultima or equivalent as approved by GE
Taking up or down 20 mm bore tubing and connections and removing off the site complete all as specified and as directed by Engineer in charge
Taking up or down 25 mm bore tubing and connections and removing off the site complete all as specified and as directed by Engineer in charge
Supply and laying of CPVC pipes 20 mm dia outer boreSDR 11 &plain CPVC SDR 11with all special fittings on walls /ceilings or laying in floors complete all as specified and as directed by Engineer in charge
Supply and laying of CPVC pipes 25mm dia outer boreSDR 11 &plain CPVC SDR 11 with all special fittings on walls /ceilings or laying in floors complete all as specified and as directed by Engineer in charge
Supply and fixing 20 mm outer dia CPVC Male Brass Threaded Adaptor (MTA/MBTA) complete all as specified and as directed by Engineer in charge
Supply and fixing 25 mm outer dia CPVC Male Brass Threaded Adaptor (MTA/MBTA) complete all as specified and as directed by Engineer in charge
Supply and fixing 20mm dia CPVC pipes brass Elbow (3/4 X1/2) complete all as specified and as directed by Engineer in charge
Supply and fixing 20mm outer dia CPVC female brass adaptor (FTA/FBTA) complete all as specified and as directed by Engineer in charge
Supply and fixing 25 mm outer dia CPVC female brass adaptor (FTA/FBTA) complete all as specified and as directed by Engineer in charge
Supply and fixing 20 mm outer dia CPVC Brass Tee complete all as specified and as directed by Engineer in charge
S&F in repair 25 mm cpvc ball valve / Gate valve screwed both ends for cpvc pipe complete all as specified and as directed by Engineer in charge
Dismantling of plain or corrugated steel sheeting, any gauge, thickness in roof covering,etc. including ridge complete all as specified and as directed by Engr-in-Charge.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and as directed by Engineer in charge
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as in ridges, hips, valley gutter, drip, and straight flashing complete all as specified and as directed by Engineer in charge
Dismantling wrought iron or mild steel work of any description not other wise provided for complete all as specified and as directed by Engineer in charge
M&L for roof trusses (framed), trusssed, purlings, crane gantries, rails and fasternings and heavy breacket frasming(Beam,tee,angle,Channel, hollow sec or flat sections) including distance pieces, cleates etc complete all as specified and as directed by Engineer in charge
S & F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment confirming to Fe-410 W (Grade E-250) quality A complete all as specified and as directed by Engineer in charge
M & L for providing cement concrete type B1 (1:2:4) using 20 mm graded aggregate as in copings,apex stones,bed plates etc complete all as specified and as directed by Engineer in charge
M&L for preparing new steel or iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engineer in charge
S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and as directed by Engineer in charge
S&F Aluminium flat as wind tie fixed with 50mm/75mm aluminium self tapping screws complete all as specified and as directed by Engineer in charge
Dismantling of ceiling boarding in description fixed in any position with nails complete all as specified and as directed by Engineer in charge
S&F Aluminium anodised snap grid false ceiling of standard aluminium section such as wall angle of size 38mm x 25mm x 2.4mm weighing 0.36 Kg/Rm main/cross tees of size 36.5mm x 25mm x 1.4mm weighing 0.24 Kg/Rm, suspended with 4mm dia GI wire at interval n.exc. 600mm centre to centre for main & cross tees fixed to roof slab roof truss fixed with suitable size MS hook and fastening bolts etc., including PVC sheet of 5 to 10mm thick of size n.exc. 610 x 610mm size fixed in ceiling with clips to aluminium snap grid complete all as specified and as directed by Engineer in charge
M&L for preparation of old wooden surfaces exc. 10cm width and girth and applying one coat of synthetic enamel paint complete all as specified and as directed by Engineer in charge
M&L for preparation of old steel surfaces exc. 10cm width and girth and applying one coat of synthetic enamel paint complete all as specified and as directed by Engineer in charge
Taking down chowkats or frames not exceeding 1.5 Sqm (with shutters & grill (if fixed) without taking off shutters from the frame) complete all as specified and as directed by Engineer in charge
Taking down chowkats or frames exc 1.5 Sqm and not exceeding 4 Sqm (with shutters and grill (if fixed) without taking off shutters from the frame) complete all as specified and as directed by Engineer in charge
S & F Solid PVC Door frame of size 50mm x 47mm made out of 5mm rudraksh colour PVC sheet reinforced with MS square tube, suppling & fixing in opening as per specification & drawing complete all as specified and as directed by Engineer in charge
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of rudraksh colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and as directed by Engineer in charge
S&F Powder coated aluminium frame for doors,windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and as directed by Engineer in charge
S & F Powder coated aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips,rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and as directed by Engineer in charge Note: Glass,wire cloth shall be measured and paid separately
Supply only 4 mm Plain sheet glass ordinary quality ,in square exc 0.5 sqm each complete all as specified and as directed by Engineer in charge
Supply only Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and as directed by Engineer in charge
Supply only Figured glass 4 mm,pin head type and glazing with oil putty in squares n exc 0.5 sqm in each pane complete all as specified and as directed by Engineer in charge
S & F Second class hard wood, plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints complete all as specified and as directed by Engineer in charge
S & F Second class hard wood factory made 40 mm thick plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS: 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and as directed by Engineer in charge
S & F Second class hard wood 35 mm thick glazed and skeleton shutters open rebated and prepared to receive glass, gauge etc divided in to squares with plain, chamfered or rounded, mitred and rebated sash bars fitted with cut and mitred beads for securing glass etc complete all as specified and as directed by Engineer in charge
M&L for preparation of new wood/wood based surfaces of exc. 10cm width or girth of any description and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed by Engineer in charge
S&F Aluminium anodised sliding door bolts 300mm long with hasp and staple complete all as specified and as directed by Engineer in charge
S&F Aluminium anodised barrel tower of extruded section 150mm long complete all as specified and as directed by Engineer in charge
S&F Extruded aluminium alloy handle fabricated type anodised 100mm long complete all as specified and as directed by Engineer in charge
S&F Extruded aluminium handle fabricated type anodised 150mm long complete all as specified and as directed by Engineer in charge
S & F Butt hinges of stainless steel 150 mm long ISI marked fixed with brass screws complete all as specified and as directed by Engineer in charge
S & F Butt hinges of stainless steel 100 mm long ISI marked fixed with brass screws complete all as specified and as directed by Engineer in charge
S & F 100mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring complete all as specified and as directed by Engineer in charge
M&L for factory made single extruded 18/19 mm thick WPC (Wood Polymer Composite) solid board one side white color and other side of board laminted with PVC foil of minimum 14 micron thickness of approved design pasted with not melt adhesive for cup boards, work stations and bathroom/kitchen cabinet etc or required sizes comprising of virgin polymer of K value 58-60 (suspension grade) calcium carbonate and natural fibre (wood powder/rice husk/wheel husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 Kg/Cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge) minimum compressive strength 50 N/mm2, modulus of elasticily 850 N/mm2 and resistance to spread of flame of class A category with property of being termite / borer proof, water / moisture proof and fire retardant and fixing with stainless steel piano hinges/soft close clip on concealed hinges of required size with necessary full body threaded star headed counter sunk S.S screws all as per direction of Engineer-in-Charge. Note: All joints should be filled with sealant.
S & F in repair curtain Rod, stainless steel,chromium plated 25 mm dia with stops, rollers etc complete all as specified and as directed by Engineer in charge
S & F in repair brass brackets chromium plated suitable for curtain Rod 25 mm dia complete all as specified and as directed by Engineer in charge
S & F in repair stainless steel plate rack of size 910 mm X 960 mm of super deluxe model, suitable for 12 plates made with 22 gauge sheet and weight not less than 5.5 Kg, complete all as specified and as directed by Engineer in charge
S&F in repair stainless steel sink made out of 1.00 mm thick sheet with plug, washers, Ms angle cantilever brackets for suitable size and connecting union to pipe of overall size 495 mm x 420 mm and bowl size 410mm x 330 mm x 160 mm complete all as specified and as directed by Engineer in charge
S&F in repair wash basins including brackets, Vitreous China (flat back or angle back type) any size, including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe complete all as specified and as directed by Engineer in charge
S & F in repair 32 mm Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc.with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and as directed by Engineer in charge
S & F in repair 40 mm Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc.with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and as directed by Engineer in charge
S & F in repair 32 mm (Dia of discharge pipe) Waste coupling of PTMT (half or full threaded) . (Minimum weight 32mm- 45gms/40mm-60 gms) complete all as specified and as directed by Engineer in charge
S & F in repair 40 mm (Dia of discharge pipe) Waste coupling of PTMT (half or full threaded) . (Minimum weight 32mm-45gms/40mm-60 gms) complete all as specified and as directed by Engineer in charge
S & F in repair Bib Taps with flange, cast copper alloy, 15 mm dia, Chromium Plated, Fancy Type with crutch or butterfly handle, screwed down for iron pipe and fixed etc complete all as specified and as directed by Engineer in charge
S&F in repairs stop valves cast copper alloy chromium plated with long shank and cup fancy type screwed down high pressure screwed both ends for pipe or union fixed for 15mm bore,including necessary cutting and making good wall or floor tiling to match existing(tiles to be paid supplied only rates) etc complete all as specified and as directed by Engineer in charge
S&F in repairs stop valves cast copper alloy chromium plated with long shank and cup fancy type concealed screwed down high pressure screwed both ends for pipe or union fixed for 15mm bore, including necessary cutting and making good wall or floor tiling to match existing etc complete all as specified and as directed by Engineer in charge
S & F in repair Two way Bib Taps, cast copper alloy, 15 mm dia, Chromium Plated, Fancy Type with crutch or butterfly handle, screwed down for iron pipe and fixed etc complete all as specified and as directed by Engineer in charge
S & F in repair Bib Taps, long boby with flange cast copper alloy, 15 mm dia, Chromium Plated, Fancy Type with crutch or butterfly handle, screwed down for iron pipe and fixed etc complete all as specified and as directed by Engineer in charge
S&F in repair brass chromium plated telescopic Hand shower(Health Faucet) (ABS Body) with 1 Meter long Easy Flex Tube in Chrome Finish& wall Hook complete all as specified and as directed by Engineer in charge
S&F in repair brass chromium plated shower rose with 150mm long CP shower arm 125 mm size revolving type suitable for 15 mm bore pipes complete all as specified and as directed by Engineer in charge
S & F in repair Soap Dish,brass chromium plated of approximate size 160 x 160 x 90 mm with screws complete all as specified and as directed by Engineer in charge
S & F in repair PVC Body Cabinet Box Mirror of size 350mm X 450mm X 100mm in PTMT alloy of approved design and pattern complete all as specified and as directed by Engineer in charge
S&F in repair Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long of approved quality complete all as specified and as directed by Engineer in charge
S & F in repairs Pillar Taps, cast copper alloy, Chromium Plated, Fancy Type, 15 mm dia, with capstan head, screwed down high pressure with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and as directed by Engineer in charge
S&F in repairs Vitreous China wash down watercloset pan (pedestal pattern), white including Plastic water closet seat, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed by Engineer in charge
S & F in repairs 10 Liters capacity, PVC Valve less, Syphonic action type, low level flushing cistern, white, with inlet ball valve, float, handle, flush pipe of polyethylene of low or high density of PVC, 32mm dia including brackets and connections to pipe of Make Slimline or Cera or equivalent make complete all as specified and as directed by Engineer in charge
S&F in repairs PVC flexible connection with PTMT nuts, of 15mm dia and 600mm long with brass unions and rubber washers on either side, for connecting water supply line to WHB, flushtank ,Geyser etc, complete all as specified and as directed by Engineer in charge
S & F in repairs Brass Chromium Plated Tubular Towel Rail, 20mm dia, D Type, 600 mm long between flanges complete all as specified and as directed by Engineer in charge
M & L for 75 mm thick PCC 1:3:6 type C-2 using 20 mm graded stone aggregate as in sub base, plinth protection etc complete all as specified and as directed by Engineer in charge
Cutting holes exc. half brick but not exc one brick in brick walls built in CM or cement lime mortar & stone walls built in lime mortar for inserting holdfasts & making good dismantled portion in CM (1:3) or PCC (1:2:4) Type B-1 complete all as specified and as directed by Engineer in charge
S & F of 8 feet (with four pipes) pulley operated clothes drying system consisting of anodized aluminium pipes , each of outer dia 22 mm and inner dia 19.80 mm pulleys made up odf derlin with rope guide mounted on channel pair of length 24'' (distance between two pipes is adjustable ) locking system to hide rope knot channel to be mounted or fixed with self tapping screws provided in kot . Rope will be polyster braided undryed of 3.5 +- 0.50mm dia complete all as specified and as directed by Engineer in charge Make: Easy Dry or equivalent as approved by GE.
Removing loose and broken concrete/ masonary surface by chiseling/ mechanically etc from the roof slab, coloumn, beam and similar structural members cutting edges, cleaning the dismantled portion with wire brush etc to make the reinforcement naked and remove dust, dirt and other foreign particle etc and removig to debries 50 Mtr from site complete all as specified and as directed by Engineer in charge
M&L for applying IPH RB -107 polymer based rust-remover (pH value –12 ) and applying IPH RB -167 Polymer based rust preventive (pH value-9) to all exposed reinforced bars complete all as specified and as directed by Engineer in charge
M&L for applying one coat of epoxy bonding coat as per manufacture's instruction to bind with old concrete / wall surfaces of soffit of slab, coloumn, beam and similar structural members for new cement surface complete all as specified and as directed by Engineer in charge
M&L for applying polymer modified cement mortar rendering 15mm average thick in CM 1:3 on concrete surface duly mixing polymer modifier of make complete finished even and smooth without using extra cement complete all as specified and as directed by Engineer in charge
Demolition and breaking up drain pipes of size 75/100 mm dia (Salt glazed ware, AC or Reinforced concrete, PVC (SWR)) set in cement mortar complete all as specified and as directed by Engineer in charge
S & F 75mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls including necessary brackets, clamps as in down pipes complete all as specified and as directed by Engineer in charge
S & F 75mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed by Engineer in charge
S & F in repairs 75 mm bore PVC [SWR] Bends of any radius including jointing with solvent cement complete all as specified and as directed by Engineer in charge
S & F in repairs 75 mm bore PVC [SWR] Junction Single [Single "T"] equal or unequal with access door including jointing with solvent cement complete all as specified and as directed by Engineer in charge
S&F in repair PVC (SWR) bends with access door 75mm dia complete all as specified and as directed by Engineer in charge
S&F in repair 75mm bore PVC [SWR] Vent Cowl including jointing with solvent cement complete all as specified and as directed by Engineer in charge
S & F in repairs 75mm dia out let, PVC (SWR) Floor Trap with SS grating including jointing to waste pipe fixed with solvent cement complete all as specified and as directed by Engineer in charge
S & F in repairs 110mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and as directed by Engineer in charge
S & F in repairs 110 mm bore PVC [SWR] Bends of any radius including jointing with solvent cement complete all as specified and as directed by Engineer in charge
S & F in repairs 110 mm bore PVC [SWR] Junction Single [Single "T"] equal or unequal with access door including jointing with solvent cement complete all as specified and as directed by Engineer in charge
M &L for Stack clamps for 75mm dia bore pipe out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts andsecuring ends of stays to wall or roof complete all as specified and as directed by Engineer in charge
M &L for Stack clamps for 100 mm dia bore pipe out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts andsecuring ends of stays to wall or roof complete all as specified and as directed by Engineer in charge
S&F in repair PVC (SWR) bends with access door 110mm dia complete all as specified and as directed by Engineer in charge
S&F in repair 110mm bore PVC [SWR] Vent Cowl including jointing with solvent cement complete all as specified and as directed by Engineer in charge
S&F in repairs chrome plated 2 in 1 wall mixer for provision of overhead shower complete all as specified and as directed by Engineer in charge
M&L for preparation of new plastered or previously untreated wall surfaces including scraping, rubbing and washing etc and applying two coats of acrylic emulsion based premium quality matt finish exterior antifungal paint over a coat of primer in all as directed and as per manufacturers instructions complete all as specified and as directed by Engineer in charge Make:- Apex Ultima or equivalent or equivalent as approved by GE
Taking down carefully existing aluminium point wiring (light, fan , socket or power) complete fittings fixture such as switches Ceiling roses, pendents,regulators, sockets etc to be measured separately)unscrewing from Board/outlet boxes, fittings & fixtures such as switches, sockets, ceiling rose lamp holder tube/ceiling fitting, bulk head fittings, tube lights & regulator etc and making good disturbed surfaces of walls, floors etc complete all as specified and as directed by Engineer in charge
M&L for taking down unserviceable submain wiring alongwith batten/PVC/steel conduits etc and making good disturbed surfaces of walls/ floors to match the existing surfaces complete all as specified and as directed by Engineer in charge
M&L for taking down carefully existing old DBs and making good disturbed surfaces of walls to match the existing surfaces complete all as specified and as directed by Engineer in charge
M&L for point wiring with two run of PVC insulated unsheathed multistranded copper conductor cable of 1.5 sqmm (FRLSH), PVC conduit medium duty/PVC casing caping and metal flush boxes (for mounting modular switches /modular sockets/ modular regulators etc) complete and including drawing one run of 1.5 sqmm PVC insulated unsheathed multistranded copper conductor cable (FRLSH) as earth continuity wire in green colour connected to common earth and each terminal box/fitting complete all as specified and as directed by Engineer in charge Note: The quoted rate inclusive for the following :- (a) GI metal flush box and Modular cover plate with frame of any module complete. (b) Proper colour coding is to be followed as per IS Specification. (c) wiring shall be concealed/ on surface with rigid PVC conduit medium grade/PVC casing caping as per site requirement.
One light point controlled by one one way switch.
One ceiling fan/exhaust fan point controlled by one switch.
One 3 pin socket outlet 5 Amps independent.
One 3 pin socket outlet 5 Amps on the same board with other switches
One bell/ buzzer point controlled by one push button independent
All as per item No 124 here in before but cable with 2.5 sqmm for socket outlet 15 amps independent complete all as specified and as directed by Engineer in charge
M & L for submain wiring with two single core PVC insulated unsheathed multistranded copper conductor cable of size 6 sqmm (FRLSH) and one single core PVC insulated unsheathed multistranded copper conductor cable green colour of size 6 Sqmm (FRLSH) as earth lead in and including concealed with PVC conduit medium grade of suitable size or surface wiring with PVC casing caping of suitable size and making good the disturbed wall surfaces to match with existing specification including takind down unserviceable submain wiring complete all as specified and as directed by Engineer in charge Note : (i) Three run of cable with one run of PVC conduit/PVC casing and caping will be measured as one length. (ii) Wiring shall be concealed/ on surface with rigid PVC conduit medium grade/PVC casing caping as per site requirement.
S&F modular switch one way 6 Amps, 1 module complete all as specified and as directed by Engineer in charge
S&F modular socket, 2/3 pin 6 amps, 2 module complete all as specified and as directed by Engineer in charge
S&F modular switch one way 16 Amps, 1 module complete all as specified and as directed by Engineer in charge
S&F modular socket, 2/3 pin 6/16 amps, 2 module complete all as specified and as directed by Engineer in charge
Supply & fixing modular bell push one way, 6 Amps, 1 module, 240 volts complete all as specified and as directed by Engineer in charge
Supply & fixing Bell, Ding Dong AC. 230 volts, single pole complete all as specified and as directed by Engineer in charge
Supply & fixing ceiling Rose, 3 terminal polycarbonate isolated body complete all as specified and as directed by Engineer in charge
Supply & fixing in repair LED lights fitting 20W, 2000lm, CDL, surge protection of 2 KV, 4 feet 220V AC with driver including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed by Engineer in charge
Supply & fixing in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt, 1000lm, CDL, 220 V AC with driver and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by Engineer in charge
Supply & fixing in repair exhaust fan made of steel body complete with louvers, voltage 230V, 50 HZ, RPM 900, Copper winding of sweep 300mm and exhaust fan shall be fixed with suitable size of buzzer bolt/hold fastner including making hole to the wall surface of any type/girth and at any height for fixing of exhaust fan complete all as specified and as directed by Engineer in charge Note :- Old unservicable exhaust fan will be deposited to MES store yard.
Supply & fixing in repair exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 HZ, RPM 1200, Copper winding of sweep 250mm and exhaust fan shall be fixed with suitable size of buzzer bolt/hold fastner including making hole to the wall surface of any type/girth and at any height for fixing of exhaust fan including making good disturbed surface with existing wall colour and provision of cable from ceiling rose/connector to fan complete all as specified and as directed by Engineer in charge Note :- Old unservicable exhaust fan will be deposited to MES store yard.
Supply & fixing in repair ceiling fan 1200mm sweep with blades, suitable BLDC electronic remote as per OEM design, down rods and connected accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM, 5 star rated, equipped with brushless direct current motor (BLDC) of wattage < 28W including provision of cable from ceiling rose/connector to fan complete all as specified and as directed by Engineer in charge Note :- Old unservicable Ceiling fan will be deposited to MES store yard.
Supply & fixing in repair electric water heater, storage type, shock resistant & rust proof engineering thermoplastic body, high grade SS inner tank, wattage 2 KW, capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, fastner bolts, 16A plug including stainless steel hose pipe complete all as specified and as directed by Engineer in charge
Supply & fixing single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 amp, 'C' curve, 10 KA complete all as specified and as directed by Engineer in charge
Supply & fixing MCB DB's SPN 12 way, IP-54, IK-09 double door, sheet metal enclosure, 240V, 100 amps rated busbar including suitable size of copper lugs for fixing of cable including taking down old unserviceable DB complete all as specified and as directed by Engineer in charge Note : The cost for flushing of Distribution box in any type of wall and making good disturbed surfaces with existing colour shall be deemed to be included in the quoted rate
S&F Surge Protection Device, breaking capacity 40KA/Pole, 4 Pole with sheet metal enclosure complete all as specified and as directed by Engineer in charge
S&F RCBO 32 Amps, double pole 240V, AC type, 30 mA complete all as specified and as directed by Engineer in charge
Supply and fixing MCB SP 6-32 Amps ,10 KA, C Curve, 230 Volts ,50 HZ complete all as specified and as directed by Engineer in charge
M&L for earthing complete with Galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised earth strip 25x4mm connected by means of bolts, nuts, check nuts and washer of galvanised iron or steel, provision of 40 mm dia GI pipe medium grade for protection of GI earth strip and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type C1 chamber, MS funnel, wire gauge, 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos, 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I. Note: (i) Cost of GI earth strip and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, PCC chamber pit and test point complete. (iii) Quoted rate deemed to be inclusive of connecting incomer DB of bldg with suitable size of single core aluminium conductor cable or copper cable and CPVC pipe complete.
AB ENTERPRISES (BID ID -3246567)
Allied Trading Company (BID ID -3247488)
bansal construction (BID ID -3246679)
M/s Pooja Enterprises (BID ID -3247497)
GAYATRI ENTERPRISES (BID ID -3247109)
Chandra Construction Enterprises (BID ID -3247421)
SK CONSTRUCTION (BID ID -3247289)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .