| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.6 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹18.4 L+₹1.1 L (6.50%)Rejected-Finance SHATYAM APPARTMENT 35 BALAI DAS CHATTERJEE ROAD HAKIMPARA SILIGURI 1 | JALPAIGURI | WEST BENGAL | 734001 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹19.5 L+₹2.3 L (13.1%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹19.8 L+₹2.6 L (14.8%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST |
Tender Value
₹21 L
EMD Value
₹42,000
Closing Date
6 Jun 2020, 6:00 pmClosed
GE SEVOKE ROAD
GE SEVOKE ROAD POST SALUGARA DIST JALPAIGURI WEST BENGAL
SPL REPAIR TO SEWAGE LINE IN OTM ACCN OF INF BN-I AND II BLDG NO P-83 HRDC AND LT PANEL AND UG CABLE OF BLDG NO P 213 GERN ROOM OF 659 AA SQN AT SEVOKE MIL STN UNDER GE SEVOKE ROAD
2020_MES_339286_2
GE/SEV/54 OF 2019-20
Open Tender
Civil Works
Item Rate
120 days
GE SEVOKE ROAD
Class E Category a(i)
7 documents required · 7 mandatory
₹500
Yes
GE SEVOKE ROAD
₹42,000
Yes
15 Jul 2020
22 May 2020
9 Jun 2020
22 May 2020
6 Jun 2020
23 May 2020
22 May 2020 - 22 May 2020
Amount
Cleaning of AC/CI pipes vertical or horizental from first floor to ground floor to inspection chamber by rodding throughly and removal of blockage by opening inspection chamber and flushing with water after cleaning all as specified and directed. (Cleaning of inspection chamber shall be measured and paid separately)
De-sludging / cleaning completely of soild/liquid sludge by pumping and or manually from inside the septic tank and removal of sludge to a distance not exceeding 50 mtrs and depositing in excavated earth pit of appropriate size duly filled up with earth in layors of 30 cm thick including spreading of bleaching powder and taking out RCC manhole cover slab for cleaning and re-setting in cm 1:6 after clearing complete as specified and directed by Engineer-in-Charge.
Note for item No 2 :- (i) Earth to be filled over the pit shall be filled after sufficient absorption of liquid and size of pit shall be made accordingly. (ii) To avoid any health hazard or spreading of any foul gas bleaching powder shall be spread as dirceted by the Enigineer-in-Charge. Cost of spreading of bleaching powder and excavating the earth pit and filing earth etc shall be included in the rate quoted under serial No 2 but supplying of bleaching powder shall be measured and paid separately.
De-sludging / cleaning completely of soild sludge by pumping and or manually from inside the septic tank and removal of sludge to a distance exc 50 mtrs and not exceeding 100 mtrs and depositing in a excavated pit of appropriate size as directed by Engineer-in-charge duly filled up with earth in layers of 30 cm thick including spreading of bleaching powder and taking out RCC manhole cover slab for cleaning and resetting in CM 1:6 after cleaning complete as specified and directed.
Note for item No 3 :- (i) Earth to be filled over the pit shall be filled after sufficient absorption of liquid and size of pit shall be made accordingly. (ii) To avoid any health hazard or spreading of any foul gas beaching powder shall be spread as dirceted by the Enigineer-in-Charge. Cost of spreading of bleaching powder and excavating the earth pit and filing earth etc shall be included in the rate quoted under serial No 3 but supplying of bleaching powder shall be measured and paid separately.
Cleaning of sewage drain pipe, RCC hume pipe, cast iron pipe of 75 mm bore by rodding with sectional sewer rod/flexible sewer rod/ bucket etc throughly from inspection chamber to man hole or from one manhole to another manhole of any depth and size and well flushing with water after cleaning and including removal of sludge and other materials obtained from cleaning the drain pipe and manhole garbage in excavated pit made for this purpose and filling up the earth complete all as directed by engineer-in-charge.
Note:- (i) Lenght of manhole also to be measured in this item. (ii) Cleaning of sewage line to be started from down stream side in this operation some pipe line gots cleaned automatically which needs to be cleaned by rodding and paid to hence the same shall not be measured and paid. (iii) The unit rate of the items shall be deemed to included for removel of sludge/ waste water accumulated in manhole/ inspection chamber due to cleaning fo drain by rodding etc. (iv) The sludge obtained shall be deposited in the pit and filled up with earth in each layer 30 cm thick as directed by Engineer-in-Charge. (v) Supply only beaching powder shall be measured and paid seperately. (vi) Cost of spreading of bleaching powder and excavating the earth pit and filling earth etc shall be included in quoted rate.
All as per item No 4 above but bore of pipe 100mm
All as per item No 4 above but bore of pipe 150mm
All as per item No 4 above but bore of pipe 200mm
Cleaning of inspection chamber/ gully trap including flushing with water or pumping air all as directed.
Cleaning of manhole any size and any depth complete including flushing with water or pumping air complete all as specified and directed.
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in soft/ loose soil and getting out complete all as specified and directed.
Demolition and breaking up drain pipes 200 mm (Salt glazed stone ware, AC or reinforced concrete) set in cement mortar and removing from site of work to a distacne n.exc 60 mtr complete all as specified and directed by Engineer-in-charge.
All as per item No 11 above but 150 mm bore
All as per item No 11 above but 100 mm bore
Demolition of cement concrete of any description and position not otherwise specifically provided for.
M&L for PCC (1:3:6) type C2 (Using 40mm gradded stone aggregate) bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested for 200 mm bore pipe complete all as specified and directed.
All as per item No 15 above but for 150 mm bore
All as per item No 15 above but for 100 mm bore
M&L for salt glazed stone ware drain pipes 200 mm bore grade 'A' laid in trenches and jointed in cement mortar 1:1 and tested complete all as specified and as directed (Any ISI marked makes).
All as per item No 18 above but 150 mm bore
All as per item No 18 above but 100 mm bore
Demolition of brick work built in cement mortar including all quoins arches, pillars etc but excluding ashlar facing, dressed stone work & precast concrete articles complete all as specified and directed by engineer-in-charge.
Material and labour for brick work with sub class 'B' bricks straight or curved on plan exceeding 6 mtr mean radius built in CM (1:4) as in brick walling using old size bricks all as specified and directed.
M&L for PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete etc complete all as specified and directed
M&L for rendering 15 mm thick in cement mortar (1:6) on other than fair face of brick wall fair finished without using extra cement including mixing with WPC of ISI marked complete all as specified and directed. (WPC shall be measured seperately) Note: WPC shall be measured seperately.
M&L for rendering 15 mm thick in cement mortar 1:6 on fair face of brick wall and finishing the surfaces even and smooth without using extra cemnet complete all as specified and directed
Removal of surplus soil to a distance n.exc 50 mtr and deposited where directed at a level n.exc 1.5mtr above the starting point complete all as specified and directed.
Returning, filling in, including spreading levelling,watering and well ramming in layers n.exc 25cm thick Complete all as specified and directed by engineer-in-charge.
Demolition of cement concretes (reinforced) as in cover slabs of any description and in any position not other wise specifically provided for Complete all as specified and directed by engineer-in-charge.
M&L for precast RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) as in cover slabs and set in cement mortar 1:6 including necessary form work and moulds complete all as specified and directed.
Supply only bleaching powder all as specified and directed.
M&L for mild steel TMT bars 8 mm dia cut to length bent to shape etc as required and binding with MS wire (annealed not less than 0.9 mm dia) as in reinforcement complete all as specified.
Supply only water proofing compound
M&L 75 mm thick cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in sub base, finished even and fair to achieve to topping layer of tiles, complete all as specified and directed.
M&L for chequered cement concrete tiles 25 cm x 25 cm x 22 mm thick (with grey cement and pigments), set, jointed and pointed in neat cement slurry with grey cement mixed with pigments to match with the colour of tiles, laid over and including 20 mm thick screed bed in CM 1:6, as in floor complete all as specified and directed.
Taking down cement or cement or lime plaster on walls / ceiling of nay description from concrete or brick wall etc including raking out joints, hacking for key, scrubbing down with water and disposing off the retreived debris out side MD land including necessary scaffoldings etc complete all as specified and directed.
Taking down chowkats or frames, exc 1.5 sqm but not exc 4 sqm each with shutters (without taking off shutters from the frame) including taking down of hold-fasts by cutting/ chasing and making good existing surfaces complete all as specified and directed.
Taking down chowkats or frames, not exc 1.5 sqm each with shutters (without taking off shutters from the frame) including taking down of hold-fasts by cutting/ chasing and making good existing surfaces, complete all as specified and directed.
M&L for rendering 20mm thick in cement mortar 1:4 in two coats (15+5mm) both coats mixed with water proofing compound @ 2% by weight of cement, surfaces of top layer finished even and smooth (without using extra cement) including necessary scaffolding etc complete al as specified and directed. Note:- WPC will be measured and paid separately as supply only.
S&F Second class Hard Wood (SAL/ Hollock/ Kalasiris) plain, solid, straigth chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue, pinned at joints, etc complete all as specified and directed.
S&F factory made, 35mm thick plain, framed panelled shutter (two panels) with lock rail and panel of 9 mm thick BWP commercial ply or 12 mm veneered particle board with commerical veneering on both faces. The size of rais and stiles shall be as per IS:1003 (Part-I), kiln seasoned and chemically pressure treated of 2nd class hard wood (Hollock / Sal/ Kalasiris), complete all as specified and directed.
S&F hold fasts etc and similar small articles made out of mild steel Flat etc of grade Fe-290 Gde-E-165 etc complete all as specified and directed.
M&L PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in bed blocks etc for hold fastes etc including provision fo necesary form work, complete all as specified and directed.
M&L for preparing surfaces of wood and wood based materials, steel and iron work, new or old, of any description and girth, not otherwise described and treated with tar or coal tar black paint, complete all as specified and directed.
S&F standard aluminum section powder coated in partition/ frame and door shutter, sliding windows/ ventilators and places otherwise not specified cut to size, jointed with cadmium plated steel screws, including rubber beading or gaskets for fixing glass or wire cloth or Bakelite sheet and all necessary fittings , hinges, screws, plugs, locking arrangements, Nylon ball bearing etc complete all as specified and directed (Aluminum section shal be of make Jindal / Hindalco / Indalco).
Note:- Weight of Aluminum sections for frames and shutters shall be only considered for paymet. Cost of other consumbles required for the item shall be deemed to be included in the quoted rate. However glass panes/ Bakelite sheet/ wire cloth/ mortice lock / locking stay/ floor spring/ floor door stopper only will be measured and paid separatley under respective items and supply only. Fixing element of these items shal be deemed to be included in quoted rate.
S&F mild steel framed work such as grills, gratings etc, with ends of bars shouldered or rebated or forged into spikes, framed guard bars, barred iron doors, railings, frame work or water tanks and similar work conforming to Fe-290 Grade E-165, complete all as specified and directed.
S&F stainless steel butt hinges, medium weight, 100mm long, complete all as specified and directed
S&F aluminium anodised barrel tower bolts of extruded section, 150mm long, complete all as specified and directed
S&F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clip of sheet, cast or extruded section and fixing bolt of extruded section or cast alumiium alloy complete all as specified and directed.
S&F aluminium anodised bow handles of 150mm size, fabricated type of extruded section fixed with screws to shutters, complete all as specified and directed.
M&L for preparation of new steel surfaces of any description over 10cm width or girth and applying two coat of synthetic enamel painting over a coat of red oxide primer, complete all as specified and directed.
M&L for 1-2mm thick wall care putty on internal surface of wall new/ old surfaces complete al as specified and as directed
M&L for applying two coats of oill bound distemper with roller over one coat of primer, after preparation of new surfaces of walls etc complete all as specified and directed.
M&L for preparation of new wooden surfaces of any description over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
M&L for preparation of old wooden surfaces of any description or not other wise described over 10cm width or girth and applying two coats of synthetic enamel paint all as specified and directed
M&L for preparation of new plastered surface of walls and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
M&L for preparation of old plastered surfaces of wall and applying two coats of white wash, complete all as specified and directed.
M&L precast reinforced cement concrete 1:11/2:3 type A-1 (using 20mm graded stone aggregates) as in cover slabs, shelves and the like including weathering, slightly rounded or chamfered angles and throating, also including use and waste of form work, complete all as specified and directed. Note:- Reinforcement shall be measured and paid separately.
S&F Anodised aluminium alloy curtain rails 20mm dia, with and including fixing brackets, stops, rollers etc, complete all as specified and directed
Dismantling floor, hearth or wall tiling and stone slabs including cement mortar bedding (but not backing), removing rubbish off the premises outside MD Land complete all as specified and directed.
M&L for coloured Non-skid cermic tiles 7 to 8 mm thick (square/ rectangular) of approved size, area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floors etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match, over and including 15mm thick cement mortar screed bed in CM 1:6 etc, complete all as specified and diected.
Dismantling asbestos cement/ galvalume aluminium zinc (corrugated or semi corrugated etc) sheets in roof coverings etc complete all as specified and directed.
M&L for 6mm thick asbestos cement, corrugated or semi-corrugated sheets in roofs, walls fixed with L type or J type or cranked hook bolts etc complete all as specified and directed
S&F pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 mpa as in roof covering/ clading to wall, fixed with self taping screws as specified
Dismantling boarding / ceiling of any description fixed in any position with nails, complete all as specified and directed.
S&F anodised alluminium snap grid frame work size 605x605 mm for false ceiling all as specified and directed
M&L for 12 mm thick perforated particle board / tiles for insulation and acoustic purposes, 60 x 60 cm in size, fixed with screws to timber frame work or with staples on snap grid in ceilings, flat or sloping complete all as specified and directed.
Re-writing letters or figures (Block, Roman, Italic or Indian) n.exc 30 cm height with synthetic enamel paint complete all as specified.
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 Mtr deep hard dense soil/ road/ PCC and getting out and levelling of bottom surface to required level for poles/ stay assembly/ cable all as specified and directed
Supply and laying in trenches/ wall LT UG XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 50 sq mm 3.5 core including making necessary connections all as specified and as directed.
Supply and fixing GI pipe 50mm medium grade for cable protection complete all as specified and dierected
S&L in trenches clear sand for cushioning under cable 8 cm below and 15 cm above complete in level all as specified and diirected by Engreer-in-Charge. Note : Punned thickness shall be measured.
M&L precast concrete cable covers class LV, type I flat, size 250x150x40mm perpendicular to the axis for the cable in trenches for protection to cable complete.
M&L for PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) for grounting, finished even and smooth without using extra cement complete all as specified and directed.
Taking down carefully old unserviceable copper/ aluminium point wiring (light, Exchaust fan, socket or power) complete incl fittings such as switches, ceiling roses, pendents, regulators, bells, sockets, tube light fittings etc, and making good disturbed surface of walls & floors etc complete all as specified and as directed.
Taking down old unserviceable main switch, DB's consisting of MCBs wooden/ GI/ MS sheet board etc all as directed
Taking down carefully unserviceable sub main wiring of any size/ core/ type including making good the disturbed surfaces all as directed
M&L for concealed point wiring with two single core PVC insulated, unsheathed, multistranded copper conductor FRLS of size 1.5 sqmm and one single core PVC insulated unsheated stranded copper conductor of size 1.50 sqmm green in colour as earth lead in and including PVC rigid conduit (medium grade) with all fittings & accessories including provn of MS sunk terminal box of appropriate size suitable for switch fixed flush to wall for mounting switch, sockets, fan regulators etc with 3mm thick hylum sheet to cover with screws & cup washers for one light/ fan point / call bell complete . Note: Cost of making good the disturbed surfaces (if any) matching with the existing surface is deemed to be included in the unit quoted rates.
All as per Item No 78 here in before but with two single core PVC insulated, unsheated, multistranded copper conductor of size 2.5 sqmm and one single core PVC insulated unsheated stranded copper conductor of size 2.5 sqmm green in colour as earth lead for 5/6 amp switch-socket point on independent board complete
All as per Item No 78 here in before but with two single core PVC insulated, unsheated, multistranded copper conductor of size 4.0 sqmm and one single core PVC insulated unsheated stranded copper conductor of size 4.0 sqmm green in colour as earth lead for 15/16 amp switch-socket point on independent board complete
All as per Item No 78 here in before but with two single core PVC insulated, unsheated, multistranded copper conductor of size 1.5 sqmm and one single core PVC insulated unsheated stranded copper conductor of size 1.5 sqmm green in colour as earth lead for 5/6 amp switch-socket point on same board complete
M&L for Switch Socket combination 3 Pin, 5 Amp flush type universal, 240 volts, complete as directed.
M&L for Socket outlet 3 Pin, 5 Amp flush type universal, 240 volts, complete all as directed.
M&L for Switch Socket Combination 5 in 1, 3 pin, 5 and 15 Amp flush type universal, 240 volts, complete as directed
S&F piano switch single pole 5 Amp 230 Volt all as specified and directed
S&F ceiling rose, surface bakelite 65mm x 50 mm size with three terminals all specified and directed
Taking down existing unserviceable FTL light fitting and S&F in repair decorative box type fitting with LED retrofit tube 21 watt with AI extruded batten luminaire for 230 volt AC, including LED tube 21 Watt complete all as directed by Engineer-in-Charge. Make:- Philips Cat Ref-BN021CLED20SPSUCWGRS2. or equivalent from list of makes.
Taking down ceiling fans of any size, sealing cable end, dismantling blades and removing fan and blades to store for refixing or as directed
S&F electronic step regulator (speed regulation in 5 steps) suitable for celing fan 1200 sweep/ 1400 mm, 120 watt complete.
S&F in repair energy efficient, 5 star rated ceiling fan 230V, 1200 mm sweep with all accesories and connecting up with the ceiling rose with required flexible wire of suitable size with ceiling fan complete all as specified and as directed, Make:- Havells/ Usha/Crompton/Khaitan.
S&F in repair wall mounted fan AC, single phase, 230/240V, of size 300 mm sweep steel/ aluminium metal body & making good the distrubed surfaces with all connecting arrangements complete. Maxx Air Dew White of make usha or equivalent of Havells/ Khaitan/ Crompton.
Taking down existing unserviceable light fitting and S&F in repair decorative full glow squre PATTENS type fitting 2'x2' with LED 60 watt with high transmittenance luminaire for 230 volt AC, complete all as directed by Engineer-in-Charge Make:- Philips. Part No-RC380B LED30S- 6500 G4 L60 W60 PSU OD OC or equivalent from list of makes.
S&F DB with sheet metal enclouser 240 volts, 12 way with 200 Amp rated bus bar single pole & neutral double door for MCB, including cutting chases for DB of reqd size and making good distrubed surface area complete all as specified and as directed.
S&F MCB double pole (DP) 240 volts of capacity 32 Amp, C curve, complete all as specified and as directed.
S&F MCB, SP, 10KA, 415V, "C" curve, 06-32Amp, ISI marked complete alll as specified and directed.
M&L for concealed sub main wiring surface type with two Nos single core PVC insulated unsheathed multi stranded copper conductor FRLS cable of size 6 sqmm and one no single core PVC insulated unsheathed multi stranded copper conductor FRLS cable of size 6 sqmm as in continuous earth wire drawn into and including surface rigid non-metallic ISI marked PVC conduit (medium grade) with all fittings and fixings accessories complete all as specified and as directed.
M&L for earthing complete with galvanized steel earth plate electorde 600x600x6mm burried directly in ground (in vertical position) earth pit not less then 2.25 mtr below narmal ground level with the top edge of the earth plate not less than 1.5 mtr (B.G.L) and connected to galvanized iron earth strip 25 x 4 mm with GI protection pipe upto pole junction box by means of bolts, nuts, check nuts, and washer of galvanized iron including PCC (1:2:4) type B1 precast RCC cover slab with suitable handle made of 6 mm round bar, including necessary excavation and earth work in any type of soil, 20 mm dia (med grade) galvanized steel tupe for watering with one end fixed with cast iron funnel and wire mess, 40 bore (light grade) galvanized steel tubing upto 7.5 mtr length for drawing earth strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion incl taking down old unserviceable earthing complete.
Supply installation testing commissioning in repair including taking down existing unserviceable panel of indooor type feeder pillar box enclosed in a modular combination polycarbonate insulated enclosure, shock proof, safe IP 54 according to Engineer-in-Charge 60529 (EN 60529), weather proof, rust proof, UV resistant, halogen free, silica free, corrosion proof internaly embeded gasket with provision of cable entry glands and / or gromments, flame retardent, self extinguisheing with glow wire test at 960 dgree C according to IEC 60695-2-11 emc complaint. Busbar system impact strength IK 08 (5 Joul) in accordance with DINEN 50102 with base frame working on 440V 3 phase 50 Hz AC supply with extendable AI busbar at both ends fully compartmentilished including excavation and PCC foundation complete all as specified (incl making necessery electrical connections) and directed with following accessories:-
M/S SUBRATA JOARDAR
M/S ASOKE KUMAR MAJUMDER
BIJAN KUMAR DHAR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .