Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.1 LAccepted-AOC | L1 | Accepted-AOC Technically and financially eligible L-1 bidder. | |
| 2 | L2₹6.6 L+₹45,510.24 (7.45%)Rejected-Finance | L2 | Rejected-Finance Not L1 Bidder | |
| 3 | L3₹6.8 L+₹72,791.84 (11.9%)Rejected-Finance | L3 | Rejected-Finance Not L1 Bidder | |
| 4 | L4₹10.5 L+₹4.4 L (71.6%)Rejected-Finance DOLA DISTRICT ANUPPUR M P | UMARIA | MADHYA PRADESH | 484001 | L4 | Rejected-Finance Not L1 Bidder |
Tender Value
₹12.5 L
EMD Value
₹15,700
Closing Date
11 Oct 2022, 5:00 pmClosed
STAFF OFFICER (CIVIL), KORBA AREA
Office of the General Manager, South Eastern Coalfields Limited, CIVIL DEPARTMENT, KORBA AREA KORBA- 495 677(CG), Mo-9425533108/ 7587390644
Roof seepage treatment with APP for Guest House at AHQ of Korba Area.
2022_SECL_258021_1
SECL/GM/KA/C/e-Tender/22-23/41 Dt. 29.09.2022
Open Tender
Civil Works - Others
Item Rate
60 days
Office of the General Manager Korba Area
As per NIT
3 documents required · 3 mandatory
₹15,700
3 Nov 2022
30 Sept 2022
13 Oct 2022
1 Oct 2022
11 Oct 2022
1 Oct 2022
1 Oct 2022 - 4 Oct 2022
Amount
Grading roof for water proofing treatment withCement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick
12 mm cement plaster of mix :1:4 (1 cement: 4 fine sand)
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter
Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in-charge.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall25 mm nominal outer dia Pipes
Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour.25mm nominal bore, weighing not less than 62 gms
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore
Brick work with clay flyash F.P.S. (non modular) brick of class designation 7.5 in superstructure above plinth level up to floor five level in :Cement mortar 1:6 (1 cement : 6 coarse sand)
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand)
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.With cement mortar 1:4 (1 cement : 4 fine sand)
Reconnecting and replacing of PVC water tanks of any size after APP/Tarfelting work on roof.
Total impact of GST for the purpose of CTC
Water Proofers
Dev Kumar Dewangan
YADAV CONSTRUCTION
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_266820.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .