Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹2.3 CrAdmitted-Finance | -37.23% | ₹2.3 Cr | L1 | Admitted-Finance |
| 2 | L2₹2.6 CrAdmitted-Finance | -29.94% | ₹2.6 Cr | L2 | Admitted-Finance |
| 3 | L3₹2.9 CrAdmitted-Finance | -21.33% | ₹2.9 Cr | L3 | Admitted-Finance |
Tender Value
₹3.7 Cr
EMD Value
₹7.5 L
Closing Date
27 Mar 2026, 6:00 pmClosed
Er ranjit singh
EXECUTIVE ENGINEER PWD RNB DIVISION RAMBAN
BOQ
2026_PWDJK_305402_1
E-NIT NO. 148 Of 2025-26 Dated 06-03-2026
Open Tender
Civil Works
720 days
Batote
NIT
2 documents required · 2 mandatory
₹6,000
Yes
S.E PWD RNB Udhumpur-Ramban Circle Udhampur
₹7.5 L
Yes
Office of SE PWD RNB Udhumpur-Ramban circle Udh.
16 Apr 2026
6 Mar 2026
28 Mar 2026
7 Mar 2026
27 Mar 2026
7 Mar 2026
11 Mar 2026
Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge.
All kinds of soil
Ordinary Rock
Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked material : All kinds of soil :
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers Eacht exceeding 20 cm in depth, consolidating Each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
Providing and laying damp-proof Course 50 mm thick with cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and curing complete
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size)
1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchors blocks, plain window sills, fillets etcupto floor V level, including curing but excluding the cost of centring, shuttering and finishing with.1:5:10 (1 cement : 5 coarse sand : 10 graded brick aggregate 40 mm nominal size
Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering,finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in arches, archribs, domes, vaults shells, folded plate and roofs having slope more than 15° upto floor five level level including curing but excluding the cost of centering, shuttering finishing and reinforcement with: 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto/above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form work for:
Foundations, footings, bases for columns
Columns, piers, abutments, pillars, posts and struts
Lintel, beams, plinth beams, girders, bressumers and cantilevers.
Suspended floors, roofs, landings, balconies and access platforms
Retaining walls, return walls, walls (any thickness) including attached pilasters buttresses, plinth and string course fillets, kerbs andsteps etc.
Edges of slabs and breaks in floors and walls. Under 20 cm wide
Stairs (excluding landings) except spiral staircases.
Providing, hoisting and fixing up to floor five level precast reinforced cement concrete in shelves including setting in cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering and finishing with neat cement punning on exposed surfaces and curing but excluding the cost of reinforcement with: 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in :Cement mortar 1:6 ( 1 cement : 6 coarse sand)
Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level
Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in : Cement mortar 1:3 ( 1 cement : 3 coarse sand)
Extra for half Brick masonry in superstructure above plinth level upto floor V level.
Extra for providing and placing in position 2 Each. 6mm dia. M.S. bars at every third course of half brick masonry.
Providing and laying autoclaved aerated cement blocks masonry with150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for separately).
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 Kg per Sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): Sal wood
Providing and fixing 35mm ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. With ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured)
Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete :25 mm dia
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
Providing and fixing bright finished brass door latch with necessary screws etc. complete. 300x16x5 mm
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete. : 200x10 mm
Providing and fixing bright finished brass handles with screws etc. complete : 125 mm
Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete
Providing and fixing aluminum die cast body tubular type universal hydraulic door closer (having brand logo with IS: 3564, embossed on the body, door weight upto 35 Kg and door width upto 700 mm), with necessary accessories and screws etc. complete
Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 Kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Eachte: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but Each extra payment on this account shall be made.
Three track three panels sliding window with fly proof SS wire mesh (Two Each. glazed & one Each wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto1.75 Sqm).
Three track three panels sliding window with fly proof S.S wire mesh (Two Each. glazed & one Each wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 Sqm).
Cost for 6 mm thick clear heat strengthened glass
Hermetically sealed double glazed unit made with 6 mm thick clear float glass both side having 12 mm air gap
Structural steel work in built up welded sections, trusses and framed work,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete.Fixed to openings / wooden frames with rawl plugs screws etc.
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc complete. On steel work
Dumping of stones in horizontal level including cost of stones
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using flats 30x6mm for diagonal braces and central cross piece.
Providing and fixing M.S. fan clamp of 16mm dia M.S. bar, bent to shape with hooked ends in R.C.C, slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge
Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Granite of any colour or shade
Wooden planking, tongued and grooved in flooring including fixing with iron screws complete: 12 mm thick Second class deodar wood
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching Pigments etc. complete.
Size of tile 600x600 mm
Size of tile 1000x1000 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shades, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints.
Size of tile 600x600 mm
Size of tile 1000x1000 mm
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per Sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 Mtr or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing precoated galvanised steel sheet roofing accessories0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per Sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :
Ridges plain (500 - 600mm)
Flashings/ Aprons.(Upto 600 mm)
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S sheets and galvanized with zinc coating of 120 gms/Sqm (both side inclusive) as per IS:277 and consisting of angle cleats of size 25 mm widex1.6mm thick with flanges of 27mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x40mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.5mm of required length with nuts & bolts of required size and other end of angle hanger fixed with G.I. channels 45x15x0.9 mm running at the spacing of 1200 centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm Each having clips of 10.5 mm at 450mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64mm diaX230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre to centre, with 25mm long drive-all screws @ 230 mm interval ,including fixing of gypsum board/calcium silicate board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25mm at 230mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the gypsum board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers’ specification and also including the cost of making openings for light fittings, grills diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer-in-Charge but excluding the cost of painting with: 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095-Part 1 : 2011 (Board with BIS certification marks)
Stone tile work for wall lining upto 10m height with special adhesive like araldite or equivalent over 12mm thick bed of cement mortar 1: 3 (1 cement : 3 coarse sand) including pointing in white cement with an admixture of pigment to match the stone shade.18mm thick (mirror polished and machine cut edges) Granite stone of any colour and shade
Providing edge moulding to 18 mm/16 mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite work
12mm Cement plaster of mix: 1:6 (1 cement : 6 fine sand)
15mm cement plaster on the rough side of single or half brick wall of mix in 1:6 (1 cement : 6 fine sand).
6MM CEMENT PLASTER 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand)
Finishing with Deluxe multi surface paint system for interiors and exteriors using primer as per manufacturers’ specifications: Painting wood work with deluxe multi surface paint of required shade. Two or more coats applied @ 0.90litre/10Sqm over an under coat of primer applied @ 0.75litre/10Sqm of approved brand and manufacture
Varnishing with varnish of approved brand and manufacture: Two or more coats of glue sizing with copal varnish over and under coat of flatting varnish.
French spirit polishing, Two or more coats on new works including a coat of wood filler
Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.2 mm thick
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content.With water thinnable cement primer on wall surface having VOC content less than 50 grams/liter
Wall Painting with acrylic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats on new work
Finishing wall with premium acrylic smooth exterior paint with silicone additives of required shade on New work (two or more coats applied @ 1.43 liter/10Sqm over and including priming coat of water exterior paint applied @ 2.20Kg/10Sqm)
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc complete On steel work
Providing and fixing pre-engineered wooden wall panelling, having tounge and grove joints. Made out of well seasoned wood of thickness 10 to 12 mm . Item is inculsive of framework of Budloo wood, cost of nails, adhesive used, conplete in all respects. labour for cutting holes/ patterns for switch boxes, etc are inclusive. Complete as per diresctions of Engineer in Charge (EIC). Sample shall be approved before installation by EIC.
Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge:1:3:6 or richer mix (i/c equivalent design mix)
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.
Providing and laying matt finished vitrified tile of specified size having water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in outdoor floors such as footpath, court yard multi models etc., laid on 20mm thick base of cement mortar 1:4 (1cement: 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as direction of Engineer-in-Charge .100x100x16 mm
Providing and laying matt finished vitrified tile of specified size having water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in outdoor floors such as footpath, court yard multi models etc., laid on 20mm thick base of cement mortar 1:4 (1cement: 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as direction of Engineer-in-Charge. 300x300x9.8 mm
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement: 3 coarse sand) including making joints with or without grooves (thickness of the joints except at sharp curve shall Eacht to be more than 5mm) including making drainage opening wherever required complete etc. as per direction of Engineer-in- charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
Supping,Installation,Testing and Commissioning of CO2 Type Fire Extinguisher 4.5 Kg. Capacity ISI Mark(IS:15683)suitable for 'B' and 'C' class fires - inflammable liquids, gaseous fires like L.P.G. and acetylene, and electrical fires
Supplying,Installation,Testing and Commissioning of MAP 90 ABC Type Fire Extinguisher 4.0 Kg. Capacity ISI Mark(IS:15683)suitable for Class A/B/C Type Fires .
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :100 mm dia
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.100mm dia
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
Providing, installation, testing and commissioning of Pressure Guages
Providing and fixing Weather proof hose cabinets for yard hydrant fabricated from 16 g MS sheet with full glass door and locking arrangement, suitable to accommodate one hydrant valve, 2 Each.15m long hose, 1 Each branch pipe and one fireman's axe. The cabinet shall be painted with one coat of primer and finished stove enamelled "Fire Red", "Fire Hose" written on front including suitably mounted on a raised masonry platform as required. (Approx 0.75mx0.6 mx 0.25 m).
Providing and fixing standard fireman's axe with heavy insulated rubber handle conforming to IS: 926 complete.
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges,tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
25 mm dia
80 mm dia
100 mm dia
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.
Supplying and stacking of good earth at site including royalty (earth measured in stacks will be reduced by 20% for payment)
Filling mixture of earth and sludge or manure in the desired proportion in trenches, flooding with water and leveling (cost of supplying earth and sludge or manure and mixing excluded)
Supplying and stacking of well decayed cow dung manure at site including royalty (cow dung manure measured in stacks will be reduced by 8% for payment)
Supply and fixing in position 3 seater benche, having legs and handle of cast iron, and seat with back rest in M.S. RHS. Duly painted with primer and then with Enamel paint. Approximate dimension of the bench be 6' x 2' x 2'-6". Inclusive of making pcc base for installtion / anchoring the bench. All inclusive as per direction of Engineer in Charge.
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30
Random Rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (1 Cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) upto plinth level and curing complete with: 7.1.1 Cement mortar 1:6 (1 Cement : 6 coarse sand)
Providing and fixing of SS plate of appropriate thickness engraved with all matter for inaugation / foundation plate as described by the department including colouring, carriages all complete job excluding cost of frame work.
Providing and laying integral cement based water proofing treatment including preparation of surfaces as required for treatment of roofs, balconies, terraces etc consisting of following operations. a) Applying a slurry coat of neat cement using 2.75Kg/Sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over the RCC Slab including adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/ Brick Bats 25mm to 115mm size with 50% of Cement mortar 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer in-charge to required slope and treating similarly the adjoining walls upto 300mm height including rounding of Junctions of walls and slabs) c) After two days of proper curing applying a second coat of cement slurry using 2.75Kg/Sqm of cement admixed with water proofingcompound conforming to IS 2645 and approved by Engineer-in-charge. d) finishing the surface with 20mm thick joint less cement mortar of mix 1:4(1 cement: 4 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300mm/sq 3mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by Engineer in-charge. With average thickness of 120mm and minimum thickness at khurra as 65 mm
Providing and fixing 25 mm thick shutters for cupboard etc, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws MDF board shutters including ISI marked nickel plated bright finished M.S. piaEach hinges IS: 3818 marked with necessary screws complete. Pre-laminated medium density fibre board exterior grade (Grade-I) IS:14587:1998 marked one side decorative and other side balancing lamination, edges to be sealed with PVC edge bending tape 2.00 mm thick of approved brand.
Providing and fixing magnetic catcher of approved quality in cupboard/ward robe shutters including fixing with necessary screws etc. complete.Double strip (Horizontal type)
Providing and fixing powder coated telescopic drawer channels 300mm long with necessary screws etc. complete as per directions of engineer-in-charge
Providing and fixing 15 cm high drawer of the cupboard with 12 mm thick base and side planks with wooden handles and 20x25 mm runner fixed with screws complete including painting and polishing.First class Teak Wood
Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws Second class deodar wood
Providing & laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen & the like consisting of: (i) Ist course of applying cement slurry @ 4.4 Kg/Sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 Kg. Per Sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to Each other with bitumen @ 1.7 Kg/Sqm).
Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge.
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid.
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040mm bowl depth 250mm
Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge.
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete: Semi rigid pipe - 40 MM DIA
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing Rectangular shape 1500x450 mm
Providing and fixing toilet paper holder with Flap made out of C.P Brass
Providing and fixing PTMT soap dish holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements,weighing Eacht less than 106gms. .
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 Mtr long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with a minimum distance of 37 mm from wall face with concealed fittings arrangements of approved quality and colour, weighing Eacht less than 88 gms.
Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931
Providing and fixing 15 mm nominal bore C.P. brass long body bib cock of approved quality conforming to IS standards and weighing Eacht less than 690 gms
Providing and fixing 15 mm nominal bore C.P. stop cock (concealed) of standard design and of approved make conforming to IS : 8931
Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931
Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. 15 mm nominal dia
Providing and fixing 15 mm nominal bore of standard back type C.P. brass close hole basin mixer pillar tap of approved quality and make, weighing Eacht less than 1.970 Kg.
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet 300 mm diameter
Providing and fixing on wall face and on ground un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring confirming to IS:5283 leaving 10 mm gap for thermal expansion. Single socketed pipes. 110 mm diameter
Providing and fixing on wall face and on ground un-plasticized - PVC moulded fittings / accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.
Coupler 110 mm
Bend 87.5° 110 mm bend
Shoe (plain) 110 mm shoe
Providing and Fixing of Floor Traps 110 mm with double chrome plated Cover one Grated and one closed and all other fittings required. Makes:- Astral/SFMC/FiEachlex
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarsesand (zone- III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floatingcoat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be Eacht less than 38 Kg (weight of cover 23 Kg and weight of frame 15 Kg) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra for depth for manholes Size 90x80 cm With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Supply, Installation of PVC Gully Trap of Size 110 mm
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge.Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc.
15mm nominal outer dia pipes
20mm nominal outer dia pipes
25mm nominal outer dia pipes
32mm nominal outer dia pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. Internal work-exposed on wall with clamps at 1.00 meter spacing
25mm nominal outer dia pipes.
32mm nominal outer dia pipes.
40mm nominal outer dia pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. External work including trenching and refilling etc.complete 40mm nominal outer dia pipes.
Providing and fixing unplasticised PVC connection pipe with brass unions: 45 cm length .15 mm nominal bore
Cutting holes upto 30x30 cm in walls including making good the same with common burnt clay F.P.S.(non modular) bricks
Supplying and Fixing of Elastomeric foam Insulation made from Nitrile Rubber with Density not less than 50 Kg/Cu.m,Thickness 10 mm for a Temp Range of -40 Deg C to 105 Deg C
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete
15 mm nominal bore
20 mm nominal bore
25 mm nominal bore
Making soak pit 2.5 m diameter 3.0 meter deep with 45x45 cm dry brick honey comb shaft with common burnt clay (non modular) bricks of class designation 7.5 bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Supply, Installation, Testing and Commissioning of mini moEach block electric water water Pump, 1.5 HP., discharge of 4700 L / hour at head of 15 m. Complete with all accessories including header Pipes, allied materials and automatic Control Panel.
Erection of HT AB Cable 50 sq mm on ST Poles 9 mtr long Rates inclusive of MATERIAL COST, Labour charges, overheads, safety equipments, handling, turnkey , GST , ETC.
9 Mtr. Long Pole( ST-410 SP33)
50 mm² AB (HT) Cable (3x50 + 1x70 mm²) XLPE(11 kV, 3C +Earth)
Heat Shrinkable Outdoor Cable Termination Kit
Suspension/Tension Clamp with eye hook
Galvanized Nuts and Bolts
Danger Plates
Anti-Climbing Device with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip
Red Oxide
Aluminium Paint
Cement bottoming 1:2:4 mix as per REC standards .45Cum /pole
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Each.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Each turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Creation of 100KVA Xmer Rates inclusive of MATERIAL COST, Labour charges, overheads, safety equipments, handling, turnkey , GST , ETC.
100 kVA (11/0.433-0.250KV;50Hz), Aluminium Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment with externally fitted MCCB with cable box and4x4 Mtrs. suitable cable of ratings.
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical
11 kV Horn Gap Fuse Set 3 Phase 200A
185 mm² (1ckt.) 1.1 kv Grade, PVC insulated stranded conductor FRLS type
9 Mtr. Long Pole( ST-410 SP33)
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of sizes including clamps
Galvinized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts, refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
11 KV polymeric composite Pin insulator, 12kv, 5 kn, lightening impulse 75 KV Positive and 80 KV Negative, creepage distance 320mm
Galvanized stay set with 50*8 mm stay clamp, guy insulator(2 Each), anchor plate (200*6mm), nuts-bolts, 2 Each turn buckets,1.8m long, 16 mm diameter solid GS stay rod & 7/15 mm dia GI strandard wire complete.
Wedge connctors/PG Clamps
Danger plates with clamps
GI Barbed wire for Anti Climbing
3-phase 4 wire Trivector meter with CT
Cement Bottoming 1:2:4 mix as per REC Strandards 0.5 Cum per pole
LT Distribution Box for 100 kVA DTR with MCCB for incomer & Switch Fuse Units for Outgoing Circuits
Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make)
Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make)
Sundry Item like aluminium lugs, jumpers, binding tape.
Laying of LT AB Cable 120 sq mm on ST Poles 8 mtr Rates inclusive of MATERIAL COST, Labour charges, overheads, safety equipments, handling, turnkey , GST , ETC.
8 Mtr. Long Pole(ST-410 SP15)
120 mm² AB (LT) Cable ( 3 x 120 + 1 x 16 + 1 x 70 mm²) XLPE (1.1kV, 3+1 C, Al)
Suspension/Tension Clamp with eye hook
Galvanized Nuts and Bolts
Danger Plates
Anti-Climbing Device with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip
Red Oxide
Aluminium Paint
Cement bottoming 1:2:4 mix as per REC standards .45Cum /pole
Insulating Piercing Connetors
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A
Wiring for Light /Power Plug with 2 x 4 sq.mm FRLS PVC Insulated Copper Conductor single core cable in surface/Recessed medium class PVC Conduit along with 1 Each 4 sq.mm FRLS PVC Insulated copper conductor single core cable for loop earthing as required.
Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in surface/Recessed medium class PVC conduit as required.
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2X 6 SQ.MM +1 X 6 sq.mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required. 1 x 15 sq. mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required
5/6 A switch
3 pin 5/6 A socket outlet
15/16 A switch
6 pin 15/16 A socket outlet
Supplying and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required
Supplying and Fixing suitable size G.I box with modular plate and cover in front on surface or in recess,including providing and fixing 6 pin 5/6 amps modular socket outlet and 15/16 amps modular switch,connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings)
Supplying & fixing suitable size Gl box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections etc. as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
1 or 2 Module (75mmX75mm)
4 Module (125mm x 75mm)
6 Module (200mm x 75mm)
8 Module (125mm x125mm)
Supplying and fixing following way, horizontal type three poleand neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
6 way (4 + 18), Double door (TPN type)
8 way (4 + 24), Double door
Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996)/conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum, energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. conductor line load reversibility, IP 20 contact protection and fitted in existing istribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc as required. OEM shall have submit NABL/CPRI/ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge.
Single pole 6/10/16/32 Amp
Single pole and neutral 63 Amp
TPN 63 Amp
Supplying & fixing of LED Batten Tube fitting 600mm size 10/11 watt Aluminium housing with 1000 Lumens and min lumens efficiency 100 lumens/watt F > 0.9
F >= 0.95 IP20, CRI >80, Flicker free, (flicker should be below 5%), life protection of 2.5 KV with Short & Open circuit protection, THD <10%, P. Supplying, installation, Testing & Commissioning of 18-22 watt LED surface mounted Batten light of following body material and construction as per IS: 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge time (LED, Driver & electrical circuitary), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends, CCT 3000 deg * K 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should Eacht more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/Name Engraved/Embossing/ Screen printing on housing complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc as required with Minimum 5 year OEM warranty. System lumen >= 105 < 120Im / W * i output. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement (Thermal management: heat sink of aluminum housing such that LED junction temperature shall Eacht rise above 90 deg * C ) Powder coated die cast / Extruded aluminium Body (Thickness mm) |>= 1.2
LED Down lighter (SMD Type) (System lumen efficacy ≥120-135lm/Watt) Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS: 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 OC to 40 OC centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD <10%, P. F20.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K/4000°K/5700°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should Eacht more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/Name Engraved/Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty, System lumen efficacy ≥120 <135 lm/Watt output LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management heat sink of aluminium housing such that LED junction temperature shall Eacht rise above 90°C). Powder coated die cast/Extruded aluminium. 18 Watt
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 Each, metal ( Aluminum alloy) blades, 30 cm long down rod, 2 Each. caEachpies, shackle kit, safety rope, copper winding, steel/Al body Power Factor Eacht less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS: 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise 75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
Exhaust fan 300 mm size (Metalic)
LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 OC to 50 OC, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%, THD < 10% as per IEC61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with70% of initial Lumen maintained till life endsas per LM80 extrapolation IES TM-21-11 report,CCT 3000°K/4000°K/5700°K /6500°K (As perANSI Bin), SDCM (Standard Deviation ColourMatching) <5, Maximum power consumption should Eacht more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall Eacht rise above 90°C). 100 Watt
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/coke and salt as required
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
SITC of wall/free standing floor mounted dust and vermin proof compartmentalized cubical panel for electrical Works, made out of CRCA sheet. Other parameters required as per point (a) Thickness of sheet shall Eacht be less than 1.6 mm up to 600 mm length/width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartment shaving bolted type doors with/without detachable extension type structure 24.00 (b) Panel shall be duly treated for derusting in 7 tank process with de phosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of Eacht less than 3mm thickness, required hardware, separate detachable gland plate M.S. base channel (min 75mm), hinged door with locking arrangement for equipment/switchgear c) Interconnection between bus bar and switch gears/cable shall be rigidly supported and made out by flexible copper wires (upto 125 amp) and by solid bus bar (>125) Lun (d) Only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator CPRI Test certificates to be submitted) All as per pre approved by Engineer in charge.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc as required. (Thermal Magnetic type, Adjustable type)
250 Amp. 36KA, FP MCCB ICU = 100% ICS
ON Load Change Over Switch FP 100 amp. (Front operated)
Aluminium Bus Bar 200 Amp set of 4 strips 18"
Aluminium Bus Bar 300 Amp set of 4 strips 18"
Supplying & laying of PVC insulated and PVC sheathed/XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable) 95 sq. mm 3.5 core
Supplying Installation Testing and Commissioning of 4MP IP IR Outdoor Bullet Camera having following specifications and features etc :- 1) Signal System: PAL/NTSC, Signal to Eachise Ratio: > 50 dB, Camera should display Camera title, Date & Time in live & recorded video 2)Image Sensor: 1/2.8" or better progressive Scan CMOS get color image even at night condition(Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better) True Day & Night High Performance Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)- Inbuilt IR LED's with effective distance upto 50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to 1/30000s electronic shutter support, Auto Gain Control White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking. 3) Compression (Minimum): Video:- H.265 or better, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.723 4) Wide Dynamic Range:- WDR (120dB or more) 5) Digital Eachise Reduction:- DNR (3D) On/Off 6) Video Streaming & Frame Rates - Triple streaming configurable Main stream: 4MP (2560×1440)25/30fps Sub streams minimum: 720P@25/30 fps 7) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser, Edge Analytics: Tripwire, Intrusion, Motion Detection 8) Cyber Security: AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, video encryption, IP/MAC filtering, HTTPS, trusted upgrade 9) Onboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card. 10) Recording Management: Format SD, overwrite. storage management, video to NAS device, 11) Alarm Trigger Motion/tampering detection, network disconnection detection; IP conflict detection. memory card state detection; memory space detection 12) Network Protocol: SFTP, IPv6, IPv4, DNS, RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPOE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast, 13) System Capability ONVIF, Camera shall support open source VMS 14) Ethernet: 1 RJ45 10/100 Ethernet port 15) Audio: It should support 1 x Built-In Mic and 1/1 Alarm In/Out for External Mic. and Speakers as per site requirement. 16) Power Input: The camera should support simultaneous dual power input-12 VDC (via power adapter) and PoE (802.3af) to ensure continuous operation in the event of a failure in one power source. 17) Power Requirement: 12VDC/24 VDC/PoE (802.3af)/ePoE 18) Housing/ Enclosure:- IP67 weather proof. IK10, Metallic body 19) Operating Condition:- Ambient Temperature:- (-)05°C to 50°C, humidity 95% (max) (non-condensing) 20) IR life: 40000 hours or higher 21) Video Bit rate: 32 KBPS-8 MBPS or better 22) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS 4MP @ 25/30fps@1440P (2560 x 1440) Outdoor Bullet Camera with 2.8/3.6/6/8/12 mm fixed lens (as per site requirement)
Supplying, installation, Testing and commissioning of following capacity 8 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under Minimum & X RJ-45 Gigabit Ethernet Ports and additional 2 X IG SFP Ports with non-blocking architecture by having Switching capacity of minimum 20Gbps and packet forwarding rate of 14Mpps or higher, 8K MAC table. Internal dual AC Power supply with operating temperature of-5 OC to +50 OC. Jumbo frame: 10KB or higher, IGMP SEachoping, IGMP sEachoping querier and support for IGMP SEachoping Fast Leave, Should create 250 or more ML.D groups, MLD SEachoping, Per VLAN MLD SEachoping C MLD SEachoping Fast Leave, STP, RSTP, MSTP, Loopback detection, Multicast filtering, VLAN Tagging. OOS & Que per port, WRR, IPv4/IPv6 Interface minimum 100 IPv4 static route entries and minimum 50 IPv6 static route entries, 700 Acess Control entries, SSH CSSL. for IPv4 and IPv6, 802.1x, ARP Spoofing, DHCP SEachoping and server screening. IP+MAC+Port Binding. Per Port Bandwidth Control, 802. IX Authentication (Supports local/RADIUS database, Port-based Access Control and EAP, OTP, TLS, TTLS, PEAP Support) Cable DiagEachtic feature, LLDP, LLDP-MED, SNTP/NTP, RMON, SNMP v1, v2c, v3 and SNMP Traps Certifications UL, CE, FCC ROHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required. 8 port PoE Layer 2 Network Switch with PoE Support of 130W or higher with Each copper port supporting 802 3at PoE+
Supplying, drawing, Testing and commissioning of Cat6A UTP 4 pair, 23 AWG solid copper cable in existing conduit/ on surface, U/FTP, LSZH, non-Plenum, Horizontal (solid) Cable suitable for high speed data networking application supporting upto 10Gbps over a 100 meter channel The 4 Unshielded Twisted Pairs (UTP) cabic with color coded insulation for easy indentification should have FLAME PROPERTIES Le. Flammability Test IEC 60332-1, Smoke Density IEC 61034, LSZH standards compliance: ANSI/TIA-568 C.2, ISO/IЕС 11801, ІЕЕЕ 802.3an, RoHS. Delay Skew should be <45NS The outer Cable Diameter should be 7.5+2 mm Cable should have been tested and verified by UL/ETL, etc complete as required. I Run of cable
RJ45 Connector for CAT 6/6A Cables RJ45 modular plug supports 4 twisted pairs, 8 positions, 8 connectors. Housing PC. UL94V-2, transparent color Use for 24-26 AWG stranded wires.
Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0 8mm CRCA Sheet, completely kEachcked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking. Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color-RAL-7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc complete as required. 6U Rack
Supplying, Installation, Testing and commissioning of following CAT6A Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required
Copper Patch Cords of length 1m (3ft)
Copper Patch Cords of length 3m (10ft)
Supplying of LED TV (Smart TV) UHD 4K
32" (Only HD)
Supplying of Refrigerator double door 315 Itr
Supplying, fixing & commissioning of vertical Storage Water Heater (Geyser) of following capacity along with PVC Pipes etc as required (5 Star with 8 Bar Pressure) 35Ltr
Supplying, Installation, Testing & Commissioning of inverter 2000 VA along-with 2 nos long tubular batteries 150 AH and trolley (Metallic) of suitable size.
Earthing with G1 carth pipe 4.5 Meter long. 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/coke and salt as required.
Providing and fixing 25 mm X 5 mm G1 strip on surface or in recess for connections etc. as required
Providing and fixing 6 SWG dia G.I wire on surface or in recess for loop earthing as required
Supply, Installation, Testing and Commissioning of IP 65 LED 50 Watt Post top with aluminium enclosure, powered with high power LEDs as light source and die casted heat sink exhibits classic Victorian Look with Symmetrical light distribution and excellent heat dissipation for long life. JUPITERMAXIPT50WLED8 30PSYMTOPC or Equivalent
Supplying, installation, testing and commissioning of 1.5 Ton Inverter type Split AC's (copper) Hot/ Cold (all weather) type of minimum capacity following Specification as detailed below 1. Should be of inverter type 2. Cooling capacity (in Tr): 15 3. BEE Star rating: 3 4. Maximum local temperature: 52 C 5. Rated cooling capacity (BTU/hr.) 19000 or above 6. Condensing coil. 100% Copper with grooved copper tubes 7 Electrical input, 220 V ± 30/50Hz/Single Phase 8. Eachise level (indoor unit) close to 35 dB 9. Compressor type: rotary or any other suitable techEachlogy 10 Refrigerant type: R-32 11. Anti-Corrosive Coating for the outdoor unit: Bule Fin/Gold Fin or equivalent 12. Compressor Warranty 10 years 13. PCB Warranty: 5 year 14. Total System Warranty: 1 year 15. Minimum Eachise level of the indoor unit should be around 28 dB (A) 16. Should have air filtering mechanism for removing dust 17 Supplier has to include brochure of the quoted model Each unit must provide cooling & dehumidification, be operatable via remote control, operate at 220-240 V AC supply with latest in vogue features. The job includes Repairs made to wall whereever as required
Supplying. Installation, Testing & Commissioning of following capacity automatic voltage stabilzer copper wound wall mounted, single phase with range of 135-240 V along with wall mounting brackets & fitting. The job includes repairing the walls where necessary Warrantee- 2 Years from the date of installation 4KVA
Supplying & fixing of M.S Wall/Floor Stand duly powder coated for outdoor unit of Split AC
Supplying & fixing of drain pipe for indoor unit 1"
Extra length of copper pipe for outdoor unit and suitable size copper cable of required size for 1.5 Ton AC
Induction Heater (Cooking)
Microwave oven Type Convection, Capacity 32 1. (1.1 Cu.ft), Power Consumption (Microwave) 1400 W, Outside (WxHxD) 52.3 cm x 30 9 cmx 50.6 cm, Colour (Door) Stainless Steel, Colour (Cabinet) Neo stamless silver, Control Method Tact+Dial, Door Type Drop Down, Cavity Material Ceramic Enamel, Turntable Size 34.5 cm, Display Type LED (Ice Blue), Convection Heater Quartz Grill Heater Sheath, Power Source 230V/50Hz, Output Power (Microwave) 900 W, Power Consumption (Microwave)1400 W, Power Consumption (Grill)1500 W, Power Consumption (Convection)2100 W, Power Consumption (Max)2900 W, Power Level 6.
Bread Toaster
Supplying, installation, testing and commissioning of following type of water purifiers alongwith PVC connecting pipes as required.(RO+ UV + UF mineral control with TDS control)
Supplying of Gas Stove 4 Burner Ultra Tuff Stainless Steel LPG Gas Stoves | Manual Ignition | Silver | Forged Brass Burner | Revolving Inlet Nozzle | 2 Years Warranty
Supplying and fixing of 90cm 1626m3/hr Slant Kitchen Chimney| Filterless Intelligent Autoclean| Built In Oil Collector| 5 Yrs Motor & 2 Yr Overall Warranty
Design, manufacture and Supplying, installation, testing and commissioning of indoor type of three phase 415 volt LT unbalanced 40 KVA servo controlled automatic voltage stabilizer copper wound oil cooled type designed for input voltage 240 V to 480 V phase to phase and output voltage 415 V ± 1% phase to phase and 230 volt ± 1% phase to neutral and frequency 50 HZ +/- 3%. The Each load current shall Eacht be more than 5% of the rated output current. The stabilizer shall be totally powder coated from outside to have aesthetic outlook and inside of tank should be zinc chromate painted. Panel should be screen-printed. The unit shall be housed in sheet steel of 14 gauge thickness having wheels with sturdy construction to withstand the rigorous shifting movement, repair works and handling. The unit shall be supplied with first filling of fresh filtered transformer oil having dielectric strength and shall be suitable for unbalanced input voltage and unbalanced output load . PROTECTIONS - Under voltage , over voltage , short circuit, overload and surge protection through suitable capacity MCCB BYPASS ARRANGEMENT - Bypass arrangement shall be provided through suitable capacity bypass switch and complete with cement concrete platform of required size as per instruction of Engineer in-charge and RiTES/CEIL (Tested) Certificate in this respect to be submitted. The job includes CAMC for 1 Years after DLP of 1 Year.
Carriage of Sand from Source to site of work by Mechanical transport including loading /Unloading complete for an avg. distance 105 km by MT
Carriage of Stone aggregate below 40mm from Source to site of work by Mechanical transport including loading /Unloading complete for an avg. distance of 35 km by MT
Carriage of Stone aggregate above 40mm from Source to site of work by Mechanical transport including loading /Unloading complete for an avg. distance of 35 km by MT
Carriage of Brick from Source to site of work by Mechanical transport including loading /Unloading complete for an avg. distance of 120 km by MT
Carriage of Stone from Source to site of work by Mechanical transport including loading /Unloading complete for an avg. distance of 35 km by MT
Carriage of AC Blocks from Source to site of work by Mechanical transport including loading /Unloading complete for an avg. distance of 95 km by MT
Carriage of Excavated Earth from Source to site of work by Mechanical transport including loading /Unloading complete for an avg. distance of 5 km by MT
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
technical_992053.pdf
techsummary_992053.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.22 MB
BOQ_992053.xls
BOQ • 0.51 MB
Download all tender documents and submit your bid