Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.5 LAccepted-AOC 1128 SECTOR 22 B NEAR AROMA PETROL PUMP CHANDIGARH UT 160022 | CHANDIGARH | CHANDIGARH | 160022 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹17.7 L+₹3.2 L (21.8%)Rejected-Finance TAILOR MARKET MAIN BAZAAR MANDI ADAMPUR 125052 | HISAR | HARYANA | 125052 | L2 | Rejected-Finance Highest | |
| 3 | L3₹20.9 L+₹6.3 L (43.5%)Rejected-Finance | L3 | Rejected-Finance Highest | |
| 4 | Rejected-Technical 5 B 2 1ST FLOOR OPP METRO PILLOR 484 TILAK NAGAR DELHI 110018 | WEST | DELHI | 110018 | - | Rejected-Technical Rejected |
Tender Value
₹20.3 L
EMD Value
₹40,508
Closing Date
21 Sept 2022, 5:00 pmClosed
RITESH NANDAL
ED - Ambala
Fire Alarm System
2022_HRY_237958_1
202279A56E64 9438 427D AF7F AE4108130581663BAR
Open Tender
Civil Works
Works
150 days
NANAKPUR
2 documents required · 2 mandatory
₹1,000
Yes
₹40,508
Yes
20 Dec 2022
7 Sept 2022
22 Sept 2022
9 Sept 2022
21 Sept 2022
9 Sept 2022
Amount
HSR [23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. Through Rate
Supply and erection of ABC Dry Power Type fire Extinguishers of 6 Kg Capacity duly hang on wall with necessary hook complete in all respect (Make: Safex/ Minimax/ Ceasefire) NS
Supply and erection of Co2 type fire extinguishers of 4.5 Kg capacity duly hang on the wall with necessary hook complete in all respect (Make: Safex/ Minimax/ Ceasefire) NS
Supply Installation, Testing and Commissioning of Glow Type Exit Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink Sulphate as bare chemical class - I material PSPA fixed on 3 mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener including cost of labour and material required to complete the job in all respect up to entire satisfaction of Engineer-in- Charge of work. Make Pearl / Giolite / OMEX NS
Supply Installation, Testing and Commissioning of wall mounting addressable UL Listed and FM approved, type sounder including power supply and accessories. Make: Bosch FNM-420 / MTH-MC-R by Siemens Cerberus/ Morley WSO PR -N05 by Honeywell NS
Supply, installation, testing and commissioning of addressable UL Listed and FM approved,control module complete as per specification. Approved Makes : Bosch FLM-420-RLV1_E , XTRI-R by Siemens, Honeywell Morley MI/DCMO NS
Supply, installation, testing and commissioning of addressable UL Listed and FM approved,Monitor module complete as per specification. Approved Makes : Bosch FLM-420-O111-E, XTRI-M by Siemens, Honeywell Morley MI DMMI NS
Supply, installation, testing and commisioning of addressable multisensor detector with a combination of Optical and Thermal including mounting base, auto addressing feauture as required. Detetctor should have 2 as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m. Shall be EN54, VDs and FM/ UL and FM certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module after 20 devices) (Makes: Bosch FAP 400 B/ Siemens Cerberus Pro OH 921 plus DB 11 E / Honeywell Morely HM/PTSE/1 plus MI/B501AP/IV NS
Supply, installation, testing and commisioning of Analog Addressable type Active Repeater fire alarm panel with Backlit LCD Display, having controls for reset, mute, Accept, Silence alarms and self test conforming to BS5839 standards and Duly approved by EN54/UN54/VDS with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. Bosch FMR/ FT 2015 by Siemens Cerberus Pro / Morley ZXR-A by honeywell NS
Supply, installation, testing and commisioning of Micro processor based 2 wire fault tolerant, networkable type fire alarm / detection control panel ( having nos.2 of loops to suit minimum 20% extra over the nos. of fire detectors. The panel shall be able to give location of all fire / fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON/OFF respective control module when ever any alarm is triggered. The panel shall have rectifier, loop cards, minimum 160 character L C D unit/ 5.7’’TFT to indicate Fire / Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects. The Panel Shall be sheet Steel power coated, sealed to IP30. The Panel shall have 20 Zones with individual LED Indicators, expandable to 80LED Indicators. The Panel shall have 3 Serial Ports. The panel shall have a built in power supply and battery charger along with maintenance free 24 AH,2 x 12 volt SMF lead acid batteries capable of running for a minimum of 24 hours with battery charger complete as required. And conforming to BS5839 standards and Duly Approved by EN 54/UL/VDS/ as per specifications complete in all respect up to the entire satisfaction of Engineer-in – charge of work Makes :: Bosch AV 2000 Series ,Cerberus pro by Siemens, Honeywell Morley Zx5se Series) NS
Supply, installation, testing and commisioning of addressable Heat detector with fixed and rate of raise feature including mounting base with LED… etc. complete as required. Each Detector should have 2 as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG /F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m. Shall be EN 54/ VDs/ UL certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) (Makes: Bosch FAH-440 plus FAA-440 , Siemens Cerberus pro HI921 plus DB11 E, Honeywell Morley MI-RHSE plus B501AP NS
Supply, installation, testing and commissioning of battery backup for controllers Online 5 KVA UPS with 1 hours backup ) Make APC/ LIEBERT EMERSON/Microtek NS
Supply, installation, testing and commissioning of minimum 1000 Mtr.Range Siren of Make : National / Kheraj NS
Supply, Installation, Testing and Commissioning of FRLS PVC unarmoured Single Core 1.5 sq. mm copper conductor PVC unsheathed Cable ( ISI marked ) of 1100V grade in existing pipe, on surface of wall with clamping/on cable tray with clamping as required excluding cost and erection of pipe but including connection etc. with all labour and material required to complete the job of Make finolex/Polycab/Havells /Plaza NS
Supply, Installation,Testing and Commisioning of Addressable UL Listed and FM approved, 2 wire Dual Action Pull Station with built in short circuit isolator, 100% soft addressed from panel, Wall mounting, resettable key option, Corrosion resistant gold plated SPST contacts, option of Single action or Dual action, optional Whether proof back box. SG42Bk2 series. Approved Makes : Bosch FMC-210-DM-G-R / XMS-D by Siemens, Honeywell Morlley HM/MCP/Glass NS
Prime Computers
NB TECHNOLOGIES INDIA
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .