Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹50.5 LAdmitted-Finance MALIK SALES AGENCIES PEERWARI SHOPPING COMPLEX KHANYAR SRINAGAR JAMMU KASHMIR 190003 | SRINAGAR | JAMMU AND KASHMIR | 190003 | L1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S MALIK SALES AGENCIES L1 |
|---|---|---|---|---|
| 1.00 | Neuroendoscope for Intacranial Procedures. Neuroendoscope set for endoscopic ventricles surgeries for obstructive hydrocephalus, intraventricular tumors, cysts, arachnoid cysts and intraparenchymal cysts. Neuroendoscope set for procedures - Ventriculostomy, Aqueductoplasty, Aqueduct Stenting, Septostomy, Foraminoplasty, Tumor Biopsy and Tumor Resections as well as Cyst Evacuation and Resection of Cyst Membranes. | 1 | EACH | - |
| 2.00 | Ventriculoscope with Wide Angle Straight Forward Telescope 4-8°, angled eyepiece for better ergonomic working, outer diameter 6-6.2 2mm, length 18-20cm, main working channel diameter 2.7-3 mm, 2 irrigation/suction side channel diameter 1.4-1.6, Scope should be autoclavable with fiberoptic light transmission incorporated. | 1 | EACH | 8,68,857 ₹9,73,119.84 Lowest |
| 3.00 | Operating Sheath to be used with 4-to-8-degree operative scope, sheath should be graduated with rota ting mechanism to keep working channel of scope in 360 degrees. Outer diameter and working length of sheath should be in compatibility with operative scope with maximum outer diameter 6.8 mm and minimum working length 13 cm. | 1 | EACH | 68,074 ₹76,242.88 Lowest |
| 4.00 | Obturator to be used with sheath.Should be compatible with sheath. | 1 | EACH | 11,641 ₹13,037.92 Lowest |
| 5.00 | Optical Obturator to be used with optical scope and sheath for guided entry into ventricles. Optical Obturator should be compatible with sheath and optical Scope | 1 | EACH | 15,318 ₹17,156.16 Lowest |
| 6.00 | Optical Scope Forward Oblique Straight Telescope 0°, scope should be enlarged view with diameter 1.9-2.lmm, length 24-26 cm, scope should be autoclavable with fiber optic light transmission incorporated | 1 | EACH | 4,34,142 ₹4,86,239.04 Lowest |
| 7.00 | Telescope 45° with enlarged view, diameter 3.1-3.3 mm, length 24-26 cm, scope should be autoclavable with fiber optic light transmission incorporated. | 1 | EACH | 4,10,589 ₹4,59,859.68 Lowest |
| 8.00 | Biopsy Forceps, double jaws movement, diameter 1.1-1.3 mm, working length 28-30cm | 1 | EACH | 70,840 ₹79,340.8 Lowest |
| 9.00 | Grasping Forceps, double jaw movement, diameter 1.1-1.3 mm, working length 28-30 | 1 | EACH | 67,634 ₹75,750.08 Lowest |
| 10.00 | Scissors, single-action movement, diameter l.1-1.3 mm, working length 28-30 cm | 1 | EACH | 52,538 ₹58,842.66 Lowest |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
5 Jul 2024, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Managing Director JKMSCL
Office of JKMSCl Jammu/Srinager
URO-ENDOSCOPIC INSTRUMENTS Set
2024_HME_245415_5
NIT/JKMSCL/MnE/2024/614 Dat19 /02/2024(instroments )
Open Tender
Medical Equipments/Waste
Item Wise
730 days
JAMMU/ SRINAGER
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
Yes
As Per NIT
₹1 L
Yes
Office of JKMSCl Jammu/Srinager
18 Feb 2025
20 Feb 2024
8 Jul 2024
20 Feb 2024
5 Jul 2024
20 Feb 2024
20 Feb 2024 - 29 Feb 2024
29 Feb 2024
Neuroendoscope for Intacranial Procedures. Neuroendoscope set for endoscopic ventricles surgeries for obstructive hydrocephalus, intraventricular tumors, cysts, arachnoid cysts and intraparenchymal cysts. Neuroendoscope set for procedures - Ventriculostomy, Aqueductoplasty, Aqueduct Stenting, Septostomy, Foraminoplasty, Tumor Biopsy and Tumor Resections as well as Cyst Evacuation and Resection of Cyst Membranes.
Ventriculoscope with Wide Angle Straight Forward Telescope 4-8°, angled eyepiece for better ergonomic working, outer diameter 6-6.2 2mm, length 18-20cm, main working channel diameter 2.7-3 mm, 2 irrigation/suction side channel diameter 1.4-1.6, Scope should be autoclavable with fiberoptic light transmission incorporated.
Operating Sheath to be used with 4-to-8-degree operative scope, sheath should be graduated with rota ting mechanism to keep working channel of scope in 360 degrees. Outer diameter and working length of sheath should be in compatibility with operative scope with maximum outer diameter 6.8 mm and minimum working length 13 cm.
Obturator to be used with sheath.Should be compatible with sheath.
Optical Obturator to be used with optical scope and sheath for guided entry into ventricles. Optical Obturator should be compatible with sheath and optical Scope
Optical Scope Forward Oblique Straight Telescope 0°, scope should be enlarged view with diameter 1.9-2.lmm, length 24-26 cm, scope should be autoclavable with fiber optic light transmission incorporated
Telescope 45° with enlarged view, diameter 3.1-3.3 mm, length 24-26 cm, scope should be autoclavable with fiber optic light transmission incorporated.
Biopsy Forceps, double jaws movement, diameter 1.1-1.3 mm, working length 28-30cm
Grasping Forceps, double jaw movement, diameter 1.1-1.3 mm, working length 28-30
Scissors, single-action movement, diameter l.1-1.3 mm, working length 28-30 cm
Flexible Biopsy Forceps with double action jaws, diameter of forcep 2.9 to 3.1 Fr and length 28-30 cm
Bipolar Coagulation Electrode, diameter 1.1-1.3mm, working length 30-32cm
Bipolar Coagulation Electrode, diameter 1.5-1. 7mm, working length 30-32 cm
Bipolar High Frequency Cord length minimum 300 cm. Universal Cable compatible with standard bipolar machines.
Articulated holding arm, L-shaped arm with mechanical central clamp for all five joint functions, height 48-50cm, operating range 50-52cm with fastener.
Socket to clamp on the operating table for use with European and United States standard rails should also be suited rails from 25x10 up to 35x8 mm. should be with lateral clamping element for height adjustment of the articulated holding arm
Metal Clamping Jaw for use with instrument and telescope sheaths, clamping range 4.8 up to 12.5 mm, with fastener.
Adaptor autoclavable, to be used with scope and camera head. this should permit telescope1 changing under sterile conditions
Ventriculoscope with Wide Angle Straight Forward Telescope 25-30°, angled eyepiece for better ergonomic working, outer diameter 6-6.2mm, length 18-20cm, main working channel1 diameter 2.7-3 mm, 2 irrigation/suction side channel diameter 1.4-1.6, scope should be autoclavable with fiber optic light transmission incorporated
Operating Sheath to be used with 25 degree to 30 degree operative scope, sheath should be graduated with rotating mechanism to keep working channel of scope in 360 degree. Outer diameter and working length of sheath should be in compatibility with operative scope with maximum outer diameter 6.8 mm and minimum working length 13 cm.
Operating Sheath to be used with 25 degree to 30 degree operative scope, sheath should be graduated with rotating mechanism to keep working channel of scope in 360 degree. Outer diameter and working length of sheath should be in compatibility with operative scope with maximum outer diameter 6.8 mm and minimum working length 13 cm.
Tray for Scope. Plastic Container for Sterilizing and Storage, container should be perforatedwith transparent lid, container should be with protected inserts for storage of two angled rigid telescopes. External, minimum dimensions (wxdxh): 515 x 240x 84 mm
Instrument Tray. Plastic Container for Sterilizing and Storage, perforated, with lid, for two- level storage, for Use with 30 cm and 36 cm Click Line- instruments, external dimensions (wxdxh ): 600 mm x 145 mm x 260 mm
Instrument Tray. Plastic Container for Sterilization and Storage of Variable Instrument,container should be double level of storage, container should be perforated with transparent lid. Container should be with silicone mat and two-level storage External minimum dimensions (wxd x h): 545 x 260 x 115 mm. The plastic container should be suitable for steam, gas and hydrogen peroxide sterilization
Neuroendoscope for Intracranial Procedures. The set must be suitable for Ventriculostomies, Septostomy, Tumor Biopsy and Cyst Fenestration
Ventriculoscope Wide Angle Straight Forward Telescope 4-6°, with angled eyepiece for better ergonomic working, outer diameter 3.4-3.6 mm, working length 18-20, working channel diameter 1.5-1.6 mm, with suction and irrigation] 2 side channels diameter 0.8-1mm, should be autoclavable Fiber optic light transmission incorporated
Operating Sheath to be used with operative scope, sheath should be graduated with rotating mechanism to keep working channel of scope in 360-degree direction. Outer diameter and working length of sheath should be in compatibility with operative scope with maximum outer diameter 4.5mm and minimum working length 13 cm,
Obturator to be used with sheath. Should be compatible with sheath
Optical Obturator to be used with optical scope and sheath for guided entry into ventricles. Optical Obturator should be compatible with sheath and optical scope
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .