GEMC-511687779794388
Awarded to THE SERVICE POINT
₹4.0 L
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| BPL ECG MACHINE 9108 | 9108 | - | 4 NOS | ₹99,450 | 397,800 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹4.0 LQualified Make: BPL
Model: 9108 D 6 BDA DUPLEX NEAR RAILWAY TRACK ZONE 1 M P NAGAR BHOPAL MADHYA PRADESH 462011 | BHOPAL | MADHYA PRADESH | 462011 | Make: BPL
Model: 9108 | L1 | Qualified | |
| 2 | L2₹4.4 L+₹44,200 (11.1%)Qualified Make: BPL
Model: BPL(RAJ SHREE) NALGARIA PINKU DEBNATH NALGARIA RANIR BAZAR 700 WEST TRIPURA TRIPURA 799035 | WEST TRIPURA | TRIPURA | 799035 | Make: BPL
Model: BPL(RAJ SHREE) | L2 | Qualified | |
| 3 | Disqualified Make: Mindray
Model: BENEHEART R3 ARYA NAGAR HARIDWAR UTTARAKHAND 249407 INDIA | HARIDWAR | UTTARAKHAND | 249407 | Make: Mindray
Model: BENEHEART R3 | - | Disqualified | |
| 4 | Disqualified Make: Contec
Model: Contec ECG1200G A 38 1ST FLOOR NARAINA INDUSTRIAL AREA PHASE 1 NARAINA INDUSTRIAL AREA PHASE 1 SOUTH WEST DELHI DELHI 110028 | NEW DELHI | DELHI | 110028 | Make: Contec
Model: Contec ECG1200G | - | Disqualified | |
| 5 | Disqualified Make: LIFE PLUS
Model: LIFEPLUS , 1212i 18 18 GANESH CHANDRA AVENUE KOLKATA CALCUTTA CENTRAL DIVISION WEST BENGAL 700013 | KOLKATA | WEST BENGAL | 700013 | Make: LIFE PLUS
Model: LIFEPLUS , 1212i | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
15 Jun 2018, 7:00 pmClosed
electrocardiography ekg/ecg units Average Turn Over of Last 3 Years 100 Lakh (s) Experience with Gov. Required 3 Year (s) Electrocardiography Ekg/ecg Units ( 4 ) Technical Specifications Specification Specification Name Values Allowed Values FEATURES Mobility
portability Protective splashproof case for clean storage and safe transport - Heart rate measurement range to be at least 30 to 250 bpm
with accuracy better than ± 5 bpm yes - Heart rate trend display of at least previous 24 hours yes - In built Software and/or standard of communication yes - Heat Dissipiation: Should maitain nominal Temp and the heat should be disbursed through a exhaust cooling fan yes - User interface manual - Noise Lavel (dba) - - 1/4 Electrical protection provided by fuses in both live and neutral supply lines yes - Operating condition: Capable of operating continuously in ambient temperature of 0 to 50 deg C and relative humidity of 15 to 90% in ideal circumstances yes - Arrhythmia detection facility required; minimum gradation of 1 bpm yes - Functional requirements: electricity;AC-powered; bedside device designed to continuously detect
measure
and display a patient’s electrocardiogram through leads and sensors attached to the patient
it also typically display heart rate
the device is typically equipped with audible and/or visual alarms that are triggered when the patien's parameters drop below or exceed pre-set limits: Continuous display of patient ECG and heart rate on screen
Allows display of single
5 lead ECG or simultaneous display of at least 5 waves selected from up to 12 points Operator can set audiovisual alarm levels for low or high heart rate Operates from mains voltage or from internal rechargeable battery yes - Power consumption - - weight - - Power cable length 3 METER OR MORE - 2/4 (meter) Display must allow easy viewing in all ambient light levels yes - Audiovisual alarms required: high and low heart rate; operator variable settings
cardiac arrhythmia
sensor/wire disconnected
low battery yes - STANDARDS AND SAFETY
CERTIFICATIONS Certification(s) US FDA approved product
ISO 13485 Certificate For Quality Standard
Electrical Safety Conforms To Standards For Electrical Safety IEC-60601-1 Shall Meet IEC-60601-1-2 (General Requirements For Safety - Electromagnetic Compatibility) And IEC 60601-2-25 (Essential Performance Of Electrocardiographs)
C E Approved product - MISCLANEOUS Warranty (years) 3 3.0 power input and frequency 220 To 240V
50 Hz AC - Certificate of Calibration and Inspection to be provided YES - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sanjeev Kumar 801507
AIIMS
Phulwarisarif
PATNA PIN-851507 4 15 EMD Required No ePBG 3/4 Required No
170913
GEM/2018/B/24358
GeM Contract
electrocardiography ekg/ecg units
GeM Contract
15 days
Bihar; Patna
PRODUCT
Awarded to THE SERVICE POINT
₹4.0 L
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| BPL ECG MACHINE 9108 | 9108 | - | 4 NOS | ₹99,450 | 397,800 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| electrocardiography ekg/ecg units Average Turn Over of Last 3 Years 100 Lakh (s) Experience with Gov. Required 3 Year (s) Electrocardiography Ekg/ecg Units ( 4 ) Technical Specifications Specification Specification Name Values Allowed Values FEATURES Mobility | - | - | - |
| portability Protective splashproof case for clean storage and safe transport - Heart rate measurement range to be at least 30 to 250 bpm | - | - | - |
| with accuracy better than ± 5 bpm yes - Heart rate trend display of at least previous 24 hours yes - In built Software and/or standard of communication yes - Heat Dissipiation: Should maitain nominal Temp and the heat should be disbursed through a exhaust cooling fan yes - User interface manual - Noise Lavel (dba) - - 1/4 Electrical protection provided by fuses in both live and neutral supply lines yes - Operating condition: Capable of operating continuously in ambient temperature of 0 to 50 deg C and relative humidity of 15 to 90% in ideal circumstances yes - Arrhythmia detection facility required; minimum gradation of 1 bpm yes - Functional requirements: electricity;AC-powered; bedside device designed to continuously detect | - | - | - |
| measure | - | - | - |
| and display a patient’s electrocardiogram through leads and sensors attached to the patient | - | - | - |
| it also typically display heart rate | - | - | - |
| the device is typically equipped with audible and/or visual alarms that are triggered when the patien's parameters drop below or exceed pre-set limits: Continuous display of patient ECG and heart rate on screen | - | - | - |
| Allows display of single | - | - | - |
| 5 lead ECG or simultaneous display of at least 5 waves selected from up to 12 points Operator can set audiovisual alarm levels for low or high heart rate Operates from mains voltage or from internal rechargeable battery yes - Power consumption - - weight - - Power cable length 3 METER OR MORE - 2/4 (meter) Display must allow easy viewing in all ambient light levels yes - Audiovisual alarms required: high and low heart rate; operator variable settings | - | - | - |
| cardiac arrhythmia | - | - | - |
| sensor/wire disconnected | - | - | - |
| low battery yes - STANDARDS AND SAFETY | - | - | - |
| CERTIFICATIONS Certification(s) US FDA approved product | - | - | - |
| ISO 13485 Certificate For Quality Standard | - | - | - |
| Electrical Safety Conforms To Standards For Electrical Safety IEC-60601-1 Shall Meet IEC-60601-1-2 (General Requirements For Safety - Electromagnetic Compatibility) And IEC 60601-2-25 (Essential Performance Of Electrocardiographs) | - | - | - |
| C E Approved product - MISCLANEOUS Warranty (years) 3 3.0 power input and frequency 220 To 240V | - | - | - |
| 50 Hz AC - Certificate of Calibration and Inspection to be provided YES - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sanjeev Kumar 801507 | - | - | - |
| AIIMS | - | - | - |
| Phulwarisarif | - | - | - |
| PATNA PIN-851507 4 15 EMD Required No ePBG 3/4 Required No | - | - | - |
Exempted
21 Jul 2018
4 Jun 2018
contract_GEMC-511687779794388.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_170913.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .