Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹15.4 LAccepted-AOC 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | 1 | Accepted-AOC Being L1 | |
| 2 | 2₹18.7 L+₹2.9 L (18.7%)Rejected-Finance | 2 | Rejected-Finance Being not lowest | |
| 3 | 3₹20.3 L+₹4.5 L (28.4%)Rejected-Finance 274 A 5TH LANE NISHATGANJ LUCKNOW UP PIN 226007 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226007 | 3 | Rejected-Finance Being not lowest | |
| 4 | 4₹22.2 L+₹6.5 L (40.9%)Rejected-Finance 301 TULSI TOWER KHADAKPADA KALYAN THANE MAHARASHTRA 421301 | THANE | MAHARASHTRA | 421301 | 4 | Rejected-Finance Being not lowest | |
| 5 | 5₹22.3 L+₹6.6 L (41.6%)Rejected-Finance | 5 | Rejected-Finance Being not lowest |
Tender Value
₹24.5 L
EMD Value
₹49,000
Closing Date
9 Sept 2021, 6:00 pmClosed
CWE Lucknow
229 MG ROAD CWE LUCKNOW
SPL REPAIR TO OLD UNSERVICEABLE LT OVER HEAD LINE INTO UNDERGROUND CABLE AT MGSF UNDER GE E/M LUCKNOW
2021_MES_467602_1
CWE/LKO/EM/T-25 OF 2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Lucknow
As per NIT
8 documents required · 8 mandatory
₹500
GE EM LUCKNOW
₹49,000
Yes
22 Sept 2021
12 Aug 2021
11 Sept 2021
12 Aug 2021
9 Sept 2021
26 Aug 2021
Amount
M & L for Laying, jointing and testing LT under ground electric power cable crossed linked polyethylene ( XLPE) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded, heavy duty 1100 Volts grade of size 16 sqmm cross sectional area, 4 core laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. with and including MS Clamps, nuts , bolts, washers complete all as specified and directed. Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles/ block and pipe shall be measured and paid separately under respective items.
All as item No 01 above but of size 35 Sqmm 3.5 core
All as item No 01 above but of size 50 Sqmm 3.5 core
All as item No 01 above but of size 70 Sqmm 3.5 core
All as item No 01 above but of size 95 Sqmm 3.5 core
All as item No 01 above but of size 120 Sqmm 3.5 core
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, pipes etc. and getting out including trimming the sides and forming bottom surfaces to required levels in soft/loose soil complete all as specified & directed.
Returning, filling in, including spreading, levelling, and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified & directed.
Removing excavated material (soils) to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified & directed.
Material and labour for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete all as specified & directed.
M&L laying well burnt old size bricks, sub class "B" bricks, straight or curved on plan, laid flat with width equal to length of brick, laid dry over electric cable for protection complete all as specified & directed.
Supplying and fixing Galvanised mild steel pipe /tubing, of size 40 mm bore dia, light grade complete with all fittings, laid in trenches / under roads, drain, paths, fixed to poles/ walls with Mild steel clamps, bolts, nuts and washers complete all as specified and directed. Note:- Excavation & Earth work, Mild steel clamps, bolts , nuts and washers shall be measured and paid separately.
All as item No 12 above but 50 mm bore size
All as item No 12 above but 80 mm bore size
Boring/Drilling (horizontally) manually under existing road (maximum 10 M in width) suitable for passing GI tubing of 40 to 100 mm bore complete all as specified & directed.
Disconnecting the cable from Panel / Pole, preparing the end for jointing including all earth work and Supply and fixing Cable end termination heat shrinkable joint including sleeves suitable for LT XLPE cable of size 3.5 core 16 to 50 sq mm complete all as specified & directed.
All as item No 16 above but size 70 to 120 sqmm
Disconnecting the cable from Panel / Pole, preparing the end for jointing including all earth work and Supply and fixing straight through heat shrinkable joint suitable for LT XLPE cable of size 3.5 core 16 to 50 sq mm complete all as specified & directed.
All as per item No 16 above beforebut size 70 to 120 sq mm
Supply & Fixing 6 Sqmm x3 core nominal cross sectional area multistranded aluminium conductor cable, over all PVC sheathed, 1100 Volts grade heavy duty cable PVC insulated and PVC sheathed complete all as specified & directed.
Preparation of old painted surfaces and painting of LT steel tubular pole 9 mtrs long from bottom to top with aluminium paint and painting to bottom up to 1.5 mtr height from top of PCC coping with synthetic enamel paint 2 coats in black and Yellow/white alternate strip including numbering in 8 cm height of number with white paint both paint aluminium /synthetic duly approved by engineer –in-Charge and complete all as specified and directed. .
Dismantling of existing old damage pole PCC & Plain cement concrete 1:3:6 type D-2 using 40 mm graded stone aggregates, as in copping of poles complete all as specified and directed.
M & L for plain cement concrete 1:2:4 type B-2 (using 40 mm graded stone aggregate) 150 mm thick complete all as specified & directed.
M&L for submain wiring alongwith earth wire with the FRLS PVC insulated multistranded copper conductor cable 2x6 sqmm & 1x4 sqmm as earth wire with and including surface PVC casing caping of size not less than 20 mm complete all as specified and directed.
Disconnecting,dismantling and taking down carefully ACSR conductor from poles of any size and setting a side complete all as specified and directed.
Dismantling taking down old cross arms, clamps, braces etc of any section from pole including nuts, bolts, washers complete all as specified and as directed.
Dismantling of insulators any type and any size complete all as specified and as directed.
Dismantling of GI wire any type and any size complete all as specified and as directed.
Dismantling of stay assembly any type and any size complete all as specified and as directed.
Supply, installation, testing and commissioning out door type cubical panel board outer shell made out of 3.15 mm thick MS sheet and inner shell made out of 2 mm thick MS sheet and MS angle section 50x50x6 mm on PCC 1:2:4 type B-1 platform 40 cm above the ground level and 45 cm below the ground level, frame factory fabricated with front and back openable double door system lockable/openable by Keys having chromium plated 19 mm dia fancy lock, louvers and air vent gasket for natural flow of air “U” type gasket shall be used to make the outer shell completely vermin proof .suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at CPRI for 35 MVA rupturing capacity at 415 Volts factory fabricated having modern fabrication and testing process which includes seven tank pre treatment process comprising of degreasing, rinsing, de-rusting, rinsing, phosphatising, rinsing and passivation followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93. Cont..../-
The TPN busbar shall be insulated with colour coaded heat shrinkable sleeve and shall be mounted on suitable size "F" class insulator at an interval not more than 250 mm through out the length of the TPN busbar.TPN aluminium busbar of rating not less than 1.5 times rated capacity of individual outgoing feeders & should be insulated with heat shrinkable PVC sleeves.comprising of the following: a) The TPN 400 Amp busbar duly plated copper busbar fitted in cascaded moulding. b) Incoming MCCB 250 Amps 36 KA, 415 volts, FP - 01 Nos c) Otgoing MCCB 100 Amps 25 KA, 415 volts, FP - 02 Nos d) Otgoing MCCB 160 Amps 25 KA, 415 volts, FP - 02 Nos e) Voltage/Ampere/Frequency meter multi functional meter - 01 No f) LED indicator lamp RYB - 01 Set of three
All as per item No 30 above but with following a) The TPN busbar duly plated copper busbar fitted in cascaded moulding. b) Incoming MCCB 250 Amps 36 KA, 415 volts, FP - 01 Nos c) Otgoing MCCB 63 Amps 25 KA, 415 volts, FP - 05 Nos d Voltage/Ampere/Frequency meter multi functional meter - 01 No e) LED indicator lamp RYB - 01 Set of three
Supply, installation, testing and commissioning out door type busbar panel board made out of 3.15 mm thick MS sheet and MS angle section 40x40x5 mm on PCC 1:2:4 type B-1 platform 40 cm above the ground level and 45 cm below the ground level, frame factory fabricated with front and back openable double door system lockable/openable by Keys having chromium plated 19 mm dia fancy lock, louvers and air vent gasket for natural flow of air “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at CPRI for 35 MVA rupturing capacity at 415 Volts factory fabricated having modern fabrication and testing process which includes seven tank pretreatment process comprising of degreasing, rinsing, de-rusting, rinsing, phosphatising and passivation followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93. Cont.../-
a) TPN, Aluminium bus bar 400 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. b) Incoming MCCB 250 Amps 36 KA, 415 Vots, 50 Hz, FP. – 1 No c) LED Indicator lamp RYB - 01 set of three. d) Necessary excavation, earth work, PCC lean type D2 and PCC type C2 platform complete all as required.
M&L Earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI strip 32 x 6 mm as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS TMT bars 8mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion.Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Supply & fixing of automatic street light switch using Infrared Sensor based for automatic switching of street lights based on LUX level of natural light. Required illuminance for switching ON is < 30 Lux and for switching OFF > 10 Lux level. The sensor (nature switch) alongwith suitable power contactors, Input (supply) MCB and output (load) MCB(s), support terminals should be enclosed in pole/ wall mountable enclosure made of rust proof, electric shock proof, termite proof and FR graded SMC junction box conforming to IP-54 degree of ingress three phase 12 KW lightening load capacity Complete all as specified & directed.
S&F MS Junction Box made of 1.6 mm thick MS sheet of size 300mmx200mmx150mm complete with front openable hinged cover and locking arrangements with 4 Nos aluminium bus bar 100 Amps, mounted on porcelain insulator including M&L for MCB SP 25A-1No, fixed on box in Din rail complete with electrical connection fixed to pole with suitable size FI clamp nut bolts and washer including duly painted with powder coated paint complete all as specified and directed.
Supply and fixing in repairs wall mounted bus -bar three ph, 4 way , 415 Volts with 4 nos Aluminium Bus bar 200 Amp in sheet metal enclosere of 1.6 mm thick MS sheet with powder coat painted including connecting with existing system and cabling network including making good disturbed surfaces complete all as specified and directed.
Prime power system
M/S S.B. Singh and Sons
Diamond Electric Co.
Sanjai sales and services
ASHU ENTERPRISES
NEXT POWER ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .