Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.5 LAccepted-AOC 51 212D 3E K V NAGAR NEAR ADARSH NAGAR KHERIA MOD AGRA UP 282001 | AGRA | UTTAR PRADESH | 282001 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹29.2 L+₹2.2 L (8.24%)Rejected-Finance 59 100 AJIT NAGAR GATE KHERIA AGRA 282008 | AGRA | AGRA | UTTAR PRADESH | 282008 | L2 | Rejected-Finance Being Higher Bidder | |
| 3 | L3₹32.9 L+₹5.9 L (21.9%)Rejected-Finance H O 325 JAIPUR HOUSE AGRA 282010 | AGRA | UTTAR PRADESH | 282010 | L3 | Rejected-Finance Being Higher Bidder |
Tender Value
Refer Docs
EMD Value
₹71,500
Closing Date
4 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF Agra
HQ CWE AF Agra
Addn / Altn to EQPT Room-I at AFNET at AF Stn Agra
2020_MES_384458_1
80020-18/E8
Open Tender
Civil Works
Item Rate
180 days
GE AF Tech Area
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE AF Tech Area Agra
₹71,500
Yes
4 Dec 2020
7 Oct 2020
10 Nov 2020
7 Oct 2020
4 Nov 2020
21 Oct 2020
9 Oct 2020 - 11 Oct 2020
60 days
Amount
Taking down carefully Aluminium/copper/flame proof point wiring (Light/ Fan/Socket or power) complete incl fitting fixture such as switches, sockets, ceiling rose, brackets, holders, bulk head fitting etc and making good disturbed surface of wall/ceiling etc., complete all as specified and directed..
Taking down old U/S sub main wiring 4 Sqmm/6 Sqmm/10 Sqmm aluminium/copper including batten/conduit and making good disturbed surface to match the existing surface complete all as specified and directed..
Taking down main switch/MCB DB/AC enclosure/Three phase enclosure by disconnecting the electric supply and connection of all wire , cable complete all as specified and directed.
M&L for point wiring complete with standard FRLS copper conductor 2.5 sqmm size (Nominal area) 1100 volts grade PVC insulated unsheathed FRLS multi stranded copper conductor cable in and including concealed PVC conduit ISI marked not less than 20mm dia or high medium grade with concealed sunk in pressed steel terminal boxes of reqd size of thickness 1.2mm factory made and painted with stove enameled black paint with top cover 3mm thick plastic laminated sheet of required colour fixed with brass screws and cup washer including 2.5sqmm standard copper conductor PVC insulated unsheathed cable of green colour as earth continuity connected to common earth dolly and all sunk/terminal boxes and each fitting/fixture, complete with all acessories and including cutting and chasing one socket out let point 6 pin 15 Amp on independent board making good the distrubed /surfaces ceiling etc surfeces complete all as directed.
M&L for point wiring complete with standard FRLS copper conductor 1.5 sqmm size (Nominal area) 1100 volts grade PVC insulated unsheathed FRLS multi stranded copper conductor cable in and including concealed PVC conduit ISI marked not less than 20mm dia with concealed sunk in pressed steel terminal boxes of reqd size of thickness 1.2mm factory made and painted with stove enameled black paint with top cover 3mm thick plastic laminated sheet of required colour fixed with brass screws and cup washer including 1.5sqmm standard copper conductor PVC insulated unsheathed cable of green green colour as earth continuity connected to common earth dolly and all sunk/terminal boxes and each fitting/fixture, complete with all acessories and including cutting and chasing complete all as specified directed.
One Socket point/light/ceilling fan/ exhaust fan point controlled by one way switch
S&F switch piano, flush type 15 Amp single pole one way 240 volts complete all as specified directed
S&F socket outlet 2 in 1, 3 pin, 5 and 15 Amp flush type complete all as specified directed
S&F switch piano, flush type 5 Amp single pole one way. 240 volts complete all as specified directed
S&F Socket outlet 2 in 1, 3 pin, 5Amp flush type complete all as specified and directed
S&F MCB single pole and neutral 40 to 63 Amp 240 volts 'B' Series 16KA. complete all as specified and directed
S&F sheet metal enclosure factory made double door for DB 240 volts with 200 Amps rated bus bar SPN 8 Way complete all as specified and directed.
S&F MCB SP 6-32 Amps, 240V 'B' Series 10 KA. (Cat No 408595) MAKE : LEGRAND/Havells or equivalent complete all as specified and directed
S & F MCB DP 40 to 63 Amp 240 Volts 'C' series 10 KA. Make Legrand or equivalent complete all as specified and directed
S & Fixing MCCB DPX 160 thermal magnetic of 160 Amps 4 pole 36 KA, 415 Volts 50 Hz complete including connecting all incoming and outgoing connection by means of suitable size of lugs/thimbles all as specified and directed Make : Legrand Cat No 420093 or equivalent
S&F MCB TPN DB,4 way Vertical type,440V,3 phase with rated busbar 250 Amps, double door type suitable for MCCB as a incomer and MCBs as out going ,IP 54-IK 09 with metal door double door type ,grouted in walls with PCC 1:2:4 type B1 using 20mm graded stone aggregate. Make-Legrand cat No-5077 50 or equivalent in C&S,Havells
Supply and fix LED Building security light 70 W IP 65 Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP65 flood light, suitable for highlighting architectural facade and general purpose lighting all as specified and directed. Make - Havells Model no:-JETANEOFL 70WLED757LTG or equivalent in philips/bajaj
S&F (Lumiline) 20 W Surface and wall mount LED Batten housing & integraded electronic driver complete all as specified and directed. Make:- Havells or equivalent
S&F in ceiling recessed mounting Endura slim pro Plus 2x2 LED panel square type, slim, compact, LED edge lit panel fitting with opal diffuser and electronic driver complete of size 36 watt LED840MODe. Make- Havells odering code ENDURASLIMPROPLUS2x2PLR28/36WLED840MODor CG/Bajaj
S&F for ceiling rose, 3 phase/PVC/polycarbonate, Isolated complete all as specified and directed
Supply and fixing sheet metal enclosure single pole and neutral with a two pin & earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and directed
M&L for point wiring complete with stranded copper conductor 4 Sqmm size (Nominal area) PVC insulated unsheathed cable FR in and including steel conduit ISI marked not less than 25mm dia with concealed sunk in pressed steel terminal boxes of reqd size of thickness 1.6 mm factory made and painted with stove enameled black paint with top cover 3mm thick plastic laminated sheet of required colour fixed with brass screws and cup washer including 4 sqmm stranded copper conductor PVC insulated cable of green colour as earth continuity connected to common earth dolly and all sunk/terminal boxes and each fitting/fixture, complete with all accessories all as specified and directed.
M&L for sub main wiring drawing in and including PVC conduit not less than 20mm dia medium grade with PVC cable 6 Sqmm nominal area 2 single core PVC insulated unsheathed cable with stranded copper conductor incl 6 Sqmm size PVC cable stranded copper conducter as earth continuity wire and connected to earth dolly complete all as specified and directed
M&L for sub main wiring drawing in and including PVC conduit not less than 20mm dia medium grade with PVC cable 10.00 Sqmm nominal area 4 single core PVC insulated unsheathed cable with stranded copper conductor incl 10.00 Sqmm size PVC cable stranded copper conducter 2 core as earth continuity wire and connected to earth dolly complete all as specified and directed
M&L for earthing complete with galvanised steel plate electrode 600mmx600mmx3.15 mm thick buried directly in ground (earth pit not less than 3.75 Mts deep below ground level with top edge of the plate not less than 3.00 Mtrs below ground level connected to galvanised earth lead wire 4.0mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl excavation and earth work and disposal of surplus soil incl 40 mm GI tubing light grade and necessary fitting for protection of copper strip incl laying of charcoal dust and common salt PCC (1:2:3) type C-1 using 20mm graded stone aggregate earth pit with 40x40x6mm MS angle iron frame, RCC cover 40mm thick (1:2:4) type B-0 using 12.5mm graded stone aggregate reinforced with 6 mm dia round bar @ 75mm C/C both ways with MS handle 12mm dia, plastering 15mm thick CM (1:6) internally and upto 150mm below ground level externally, PGI funnel with 20mm dia GI pipe for watering and wire mesh complete all as specified and shown on electrical plate No 3 of SSR Part (2009) and connected to earth test incl testing complete. Note:- On testing after completion if desired earth resistance is not obtained, the earthing will be redone at no extra cost.
Supply of material and labour for making 'Tercel' high conductive, non corrosive maintenance free yet repairable chemrod electro steel chemical gel earth pit using earth enhancing compound ISOGEL of 20 kg kit ISOROD of 3 inch dia 8 ft long and 0.12 inch thick made of K type elkectrolytic copper with top removal gel filling cap seepage holes stainless steel fasteners HDP lockable earth pit cover um inspection chamber and all required accessories including design modifications to achieve the required earth termination rod resistance value as per the OEM/international standard recommendation all as specified and directed.
S&F Copper strip 32 x 6 mm with saddles/insulators and fixing screws or buried in ground etc. for continous earthing strip.
Supply, laying commessioning, testing of XLPE , armoured heavy duty electric under ground LT cable 1100 volts grade of size 120 sq mm 3½ core with aluminium conductor to IS 1554, ISI laid in tranchies, fixing on wall, under road crossing, etc complete all as specified and directed by Engr-in-Charge.
M&L for Bus Bar Panel of capacity 320 Amps with 04 Nos copper bus bar fixed on insulator and panel fixed on pole/wall with bracket made out of FI of size 25x3mm-02 Nos including providing new nut, bolt & washers complete all as specified and directed.
S&F Offload change over switch with sheet metal enclosure & side handle of capacity 320 Amps, 415 Volts,4 pole including fixing on wall/panel,connecting with existing cable etc complete all as specified and directed. Make- C&S/Havells/ABB
Taking down XLPE cabel of size upto 70 Sqmm as per specified and directed
Supply, install, test and commissioning of factory made floor mounted LT Panel Out door type CPRI approved (double door) made out of 3.15mm thick CRCA sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front and rear opening and locking arrangement 415Volts, 3 phase, 50 Hz having copper bus bar of capacity 200 Amps and full neutral duly colour coded and for neutral supported with DMC/SMC insulators colour coded with heat shrinkable sleeve hearing short circuit current with stand minimum 85 KA for one second complete connection from bus bar to breakers with suitable copper cable , panel board shall be grouted in the ground with suitable size of foundation in PCC 1:2:4 type B1, MS channels for base frame 50x50x6 mm and supports, GI nut, bolts, washers etc. The panel board shall be powder coated and red oxided primed.with following accessories:-
MCCB 250 Amps, 36 KA , 4 pole,Thermal magnetic. Make Legrand (Incommer)-01 No
MCCB 160 Amps, 25 KA , 4 pole Make Legrand (O/G)-02 No
Cable Glands-05 Nos
Indicator Lamp RYB-1set
LT Panel with busbar & inter connection-1 Job
S&F aluminium/copper Lugs of suitable size for operating cable 120 sqmm x 3.5 core complete all as specified and directed.
S&F cable root indicator made out of MS sheet of size 30cmx20cm of 4mm thick with writing HT/LT cable with MS angle iron frame and two Nos legs of 1.2 m long of size 25x25x5mm fixed in ground in PCC 15cmx15cmx15cm including painting of specified colour over one coat of red oxide primer complete all as specified and directed
Excavation in trenches in soft/loose of soil not exceeding 1.5 metre deep and not exceeding 2.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes/pole foundation etc. all as specified and directed by Engineer-in-Charge.
Returning, filling in including spreading, leveling, watering and well ramming in layers n. exc 25 cm thick after the cables etc. are laid, jointed and tested complete all as specified and directed by Engineer-in-Charge.
Removal of surplus excavated soil not exceeding 50 Mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Supply and laying sand cushioning for cable protection in trenches 8cm before laying cable and 15cm thick over the cable all as specified and directed.
Supply & lay brick well burnt bricks sub-class 'B' locally available old size laid flat acres the length of trench for protection of cable complete all as specified and directed
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality of capacity 2.0 TR with minimum 3 star rating complete all as specified and directed
(a) Fixing only cooling unit with grouting nuts, bolts , cutting groove to wall for gas pipe and water drainage pipe complete all as specified and directed at site.
(b) Fixing cutting, bent to shape copper pipe of appropriate size from out door unit to indoor unit by cutting hole to wall including brazing the copper pipe of appropriate size all as required at site.
(c) Insulation of both the copper pipe with insulating material and covering the complete pipes with PVC casing and capping of size 75x75 mm for mechanical protection of copper pipe complete.
(d) S&F MS Bracket and fasterner suitable for out door unit of split type AC.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and directed.
M&L for shifting of air conditioner window ACs of any capacity and model from one room to another room situated within the same building including gas charging with required quantity of refrigerant gas R-22/M-22 or suitable gas and all fixing arrangement, complete all as specified and directed.
M&L for shifting of air conditioner split type ACs of any capacity and model from one room to another room situated within the same building including gas charging with required quantity of refrigerant gas R-22/M-22 or suitable gas and all fixing arrangement, complete all as specified and directed.
M&L for cutting openings, through brick walls built in cement mortar or cement lime mortar for door, window and other openings or enlarging existing openings, converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc., to store and rubbish not exc. 50m complete all as specified and directed.
Taking down chowkhats or frames shutters without taking off shutter and builders hardware fitting from the frames n. exc 1.5 sqm each and removing complete all as specified and directed..
All as per ser itme No 51 here in before exc. 1.5 sqm but n. exc 4 sqm
S&F aluminium powder coated section for door, partition , window with one or more rebates including joint cleat, rubber beads for fixing etc, complete all as specified and directed
S&F 5.5mm thick sheet glass ordinary quality for Aluminium frames fixed with aluminium cleat and rubber beading in each pane n.exc 0.50 sqm each complete all as specified and directed.
S&F powder coated aluminium grills size cx. 4mmx4mm, 8mm thick and aperture n.exc. 80 mm width and including fixing with aluminium channel, 1 mm thick with steel screw and tint match with existing complete all as specified and as directed.
S&F Stainless steel butt hinges of 100 mm medium duty and fixed size complete all as specified and directed.
S&F aluminum alloy handles cast type anodised of 150mm complete all as specified
S&F extruded aluminium anodised barrel tower bolts of extruded section 150mm long complete all as specified.
S&F brass 4 levers mortice lock, vertical type, size 100mm including fittings/fixtures complete all as specified.
S&F aluminium (die cast) body door closer hydraulically regulated, designations No 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete complete all as specified.
S&F floor door stopper 140mm long of aluminium alloy body and tongue, anodised, with ard drawn steel spring fixed in floor complete all as specified and as directed.
Excavation in trenches in any type of soil n exc. 1.5m wide and n exc 1.5m deep;for foundation,etc.or for shafts, wells cesspits, manholes, pier holes,etc.n exc.10 sq m on plan and n exc. 1.5 m in depth and getting out in hard/dense soil.
Removal of surplus soil to a distance n exc 50m and depositing where directed at level n exc 1.5m above the starting point complete
Returning, filling in trenches with excavated soil, including, spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
M&L hard core of broken stone agg in gauge not exc 63 mm spreading levelling in layers n.exc 15 cm thick watered and rammed to true surfaces complete all as specified and directed
M&L PCC 1:2:4 type B2 (Using 40mm graded stone aggregate) as in surface channels and drains and the likes including necessary form work complete all as specified and as directed.
M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed .
S&F plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe 410 -W (GdeE- 250) quality A. complete all as specified and directed.
Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified. Note :- Contractor to fabricate plywood partition on wooden framework to protect sofisticated equipments from dust and damage during demolition. Approx dimension of partition will be 4.50 mtr x 4.50 mtr. Plywood partition will be removed and taken back by the contractor after demolition and connected works are over. Contractor to quote his unit rates keeping in mind plywood fabrication and dismantling of the same. Nothing extra shall be payable on this account.
M&L for brick work in CM 1:6 using sub class B old size bricks, straight or curved in plan n exc.6m mean radius complete all as specified and directed .
Taking down of cement plaster on brick walls etc incl raking out joints hacking for key, scrubbing down with water etc including removal of debaris and rubbish from the site complete all as specified and directed.
M&L for 20mm thick rendering in cement mortar (1:4) in two layers (10mm thick each) with water proofing compound in top layer as per manufacturer's instructions finished even and smooth without using extra cement complete all as specified and as directed. Note : Integral water proofing compund shall be measured and paid separtely.
M&L for preparation of newly plastered surfaces and applying two coats of cement base paint complete all as specified and directed.
M&L for 15 mm thick rendering in CM 1:6 on fair faces of brick work & concrete, finished even and fair on internal wall suface with out using extra cement complete all as specified & directed.
M&L for distempering on new plastered surfaces of walls with two coat of acrylic distemper white or tinted over a thin layer of Birla wall care putty complete all as spd and directed
Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc 15 cm thick below or above ground level and removing the demolished material to a distance nexc 50 m and depositing where directed, complete all as specified and directed.
M&L 75mm thick PCC 1:3:6 type C2 (using 40 mm mm graded stone aggregate) as in sub base of floors complete all as specified and directed
M&L 25mm thick PCC 1:2:4 type BO (using 12.5 mm graded stone aggregate) as in leveling course of floors complete all as spd and directed
M&L screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and directed.
M&L for light shade vitrified ceramic tiles, joint free (edge cut) coloured , 10mm thick (sqare/ rectangular) polished, area of each tiles n.exe 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed with coloured cement to match the tiles complete all as specified and directed.
M&L rendering 10mm thick in cement mortar 1: 4 on faces of brick work or concrete surfaces as in back of tiles etc complete all as specified and directed .
M&L for light shade vitrified ceramic tiles, joint free (edge cut) coloured , 10mm thich (sqare/ rectangular) polished, area of each tiles n.exe 0.36 sqm, in skirting etc set and jointed in neat cement slurry and pointed with coloured cement to match the tiles complete all as specified and directed.
M&L 4mm thick PVC tiles/ sheets, homogenous, laminated plain coloured, marbled mosaic or mottled finish, laid with approved rubber based adhesive in floors complete all as specified and directed.
M&L PCC 1:3:6 type C1, 75 mm thick finished even and smooth without using extra cement including making joints 10mm width to the full depth of PCC at every 3m and change of direction and joint filled with sand and bitumen in ratio 1:1 by weight as in plinth protection complete all as specified and directed .
M&L PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed complete all as specified and directed.
M&L RCC 1:2:4 Type B1 (using 20mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
M&L RCC 1:2:4 Type B1 (using 20mm graded stone aggregate) as in columns, pillars, piers, posts and struts complete all as specified and as directed.
M&L RCC 1:2:4 Type B1 (using 20mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels complete all as specified and as directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, rough finished surfaces of concrete complete all as specified and as directed by Engineer-in-Charge.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions, rough finished surfaces of concrete complete all as specified and as directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. , rough finished surfaces of concrete complete all as specified and as directed.
S&F TMT mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
S&F TMT mild steel bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Dismantling wall and ceiling boardings, any description, fixed with nails, any thickness and in any position including cover fillets complete all as specified and as directed.
M&L for solid PVC wall lining consisting of 5.00mm thick single site prelam PVC sheet inclusive of insolvent cement and fixing at site on PVC frame all as specified and directed.
S&F 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on to wall to make PVC frame all as specified and directed complete all as specified and directed.
S&F PVC decorative beading fix with adhesive paste/nails all as per manufacturer's instructions complete all as specified and directed.
S & F suspended false ceiling grid system 600 x 600 mm with main runner 39 x 29 x 0.8 mm , cross tee 39 x 27 .7 x 0.80mm and wall angle 22.2 x 22.2 x 0.65 mm in ceiling suspended with 4 mm dia GI wire hangar fixed with steel dash fasteners or from purlin of roof with butterfly clips hold down etc, complete ,( main runner / cross tee /wall angle of MS galvanised powder coated ) all as specified and directed.
S & F 6mm thick HPSC pre-prime non asbestos fibre cement building board (E-classic ) decorative finish fixed to aluminim or MS galvanised snap grid frame work with hold down clips in ceiling complete all as specified and directed. Make : EVEREST/ RAMCO/ CHARMINAR
Taking down existing tarfelt or other roof treatment from roof and rubbish off the premises including removing debries at a place as directed complete all as specified and directed
M&L PCC 1:2:4 type B1 using 20mm graded stone agg as in levelling course / padding over roof complete all as spd and directed.
M&L15mm thick screed in cement mortar 1:4 on concrete surfaces with WPC, finished even and fair W/O using extra cement complete as in roof. (WPC shall be measured & paid seperately complete all as specified and directed .
Supply only water proofing compound complete all as specified and directed.
M&L water proofing treatment to RCC Roof slab including parapet comprising with the following course of treatement/specified from bottom to top :- (a) Applying Bituminous primer @ 0.40 Ltr per Sqm over plastered surfaces of Roof including parapet surfaces. NOTE : Bituminious primer shall be 'MASTIC' manufactured by M/S STP LTD or 'TEXSA' (b) Over the priming coat laying one layer APP based polymeric membranes of approved manufacturer, 3mm thick weight not less 3.60 Kgs/Sqm reinforced with non woven polyester fabric weight not less than 150 gms per Sqm. Polymeric membrane shall be taken to a height of 60cm (minimum) and then inserted inside the groove of parapet wall and shall be finished by a membrane flushing in a coat of aluminium paint over roof surfaces. (i) Laying APP based polymeric membranes shall be done by torch on method as per manufacturer's instructions. (ii) A minimum overlap of 100mm shall be made and at the end 75mm shall be made at the sides of the polymeric membranes respectively and sealed all overlaps and joints as per Manufacturer's instructions. (c) Applying two coats of bituminous aluminium paint over top of APP membrane.
deva engineers
Rakesh kumar
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .