| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.2 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹4.4 L+₹17,597 (4.19%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹4.4 L+₹24,865 (5.92%)Admitted-Finance | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | WEATHER CONTROLS L3 | COOLMAN L2 | WEATHER CONTROL CORPORATION L1 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, Installation, Testing and Commissioning of (Non Inverter) 4.0 Tr Tower Air conditioner comprising single out door and single stand indoor machine complete with factory-charged Rotary/Scroll compressors (R-32/R-410A eco friendly refrigerent). The system shall operate on 440 V, 50Hz (±tolerance as per applicable standard), star rating the capacity of >10,465watt( > 9000 kcal/hour), three-phase AC supply, providing cooling, dehumidification, and air circulation functions conforming to IS-1391 (Part-II ) with all amendments, and shall be capable of efficient performance at outdoor ambient temperatures up to 50°C, with a minimum 5- year OEM warranty on both the compressor and PCB. The system shall be installed with S&F appropriate fixing arrangements as per OEM recommendations, including wall openings, mending well the damages and making necessary connections including T&P & labour etc as required complet in all respect as per the direction of EIC.Cooling Capacity- 14 kW (Minimum) , Air Flow Rate:600 CFM (Minimum)
(Make- Mitsubishi / Daikin / Voltas/ Blue Star) | 2 | Nos | 1,62,000 ₹3,24,000 | 1,60,000 ₹3,20,000 | 1,53,000 ₹3,06,000 Lowest |
| 2.00Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for Tower AC system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 25 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : | ||||||
| 2.10 | 5/8 inch or 15.8 mm dia (OD) (Soft drawn) as per standard BS864 & ANSIB 16.22 ( for suction line) | 32 | Mtr | 1,230 ₹39,360 | 1,150 ₹36,800 | 1,147 ₹36,704 Lowest |
| 2.20 | 3/8 inch 9.5 mm dia (OD) (Soft drawn) Soft drawn) as per standard BS864 & ANSIB 16.22 ( for discharge line) | 32 | Mtr | 630 ₹20,160 | 600 ₹19,200 | 595 ₹19,040 Lowest |
| 3.00 | Supply & laying hard Drawn PVC Drain Pipe 25 mm dia with proper supports & brackets as per direction EIC. | 15 | Mtr | 155 ₹2,325 Lowest | 178 ₹2,670 | 157 ₹2,355 |
| 4.00 | S&F of 4.0 core 4.0 sq mm unarmoured copper cable for controlling indoor to outdoor units (FRLS type) (Make: Polycab/ Finolex/ KEI/ Gloster/ RR Kabel) | 32 | RM | 377 ₹12,064 | 382 ₹12,224 | 375 ₹12,000 Lowest |
| 5.00 | Supplying, fabrication and fixing of MS u- channel of 6mm thick of size (75mm X 40 mm X 40 for installation of outdoor unit of ACs including drilling 2 nos holes in each channel inclu the same with cement concrete (1 :1 1/2:3) etc. fabbdcated with horizontal agle of 25mmx 25 mm x 6 mm supporting angle of 50mm x50mm x6 mm in each platform. The platform should be baricaded and set for ODU machine in outer angle transmitting the load centraly through 2 nos (50 mm x 50 mm x6 mm )angle increated in to the wall incl fiber sheet shade as per direction of EIC . The area of the platform is of suitable size as per machine configuration and load with addiquiet service acces & safe to cary out the maintenance of ODU as per direction of EIC. The design of platform structure to be approved by EIC, including painting the entire structure. | 143 | kg | 155 ₹22,165 | 174 ₹24,882 | 150 ₹21,450 Lowest |
| 6.00Providing and fixing thermal insulation of ceiling (underdeck insulation) with Resin Bonded Rockwool conforming to IS:8183, density 48kg/m3,50mm thick, wrapped in 200G Virgin Polythene bags fixed to ceiling with metallic cleats (50x50x3mm)@60 cm and wire mesh of 12.5mm x 24gauge wire mesh for top most ceiling of building. | ||||||
| 6.10 | Ceiling of top floor | 18 | sq mtrs | 1,380 ₹24,840 | 1,215 ₹21,870 Lowest | 1,250 ₹22,500 |
Tender Value
Refer Docs
EMD Value
₹6,876
Closing Date
11 Sept 2026, 2:00 pmClosed
AE/LBESD/PWD
81/2/2, Phears Lane, Civil Defence Building Kolkata-12
Supply and Installation of 4.0 Tr. Tower AC machines to be installed at server room of Traffic Building, Lalbazar, Kolkata Police Head Quarters under Lalbazar Electrical Section ,PWD
2026_WBPWD_5021368_1
WBPWD/AE/LBESD/eNIQ-12Q of 26-27
Open Tender
ELECTRICAL WORKS ORG
Item Rate
15 days
Lalbazar Police Headquarter
Please refer Tender documents.
6 documents required · 6 mandatory
₹6,876
AE/LBESD
5 Oct 2026
1 Sept 2026
14 Sept 2026
1 Sept 2026
11 Sept 2026
2 Sept 2026
2 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, Installation, Testing and Commissioning of (Non Inverter) 4.0 Tr Tower Air conditioner comprising single out door and single stand indoor machine complete with factory-charged Rotary/Scroll compressors (R-32/R-410A eco friendly refrigerent). The system shall operate on 440 V, 50Hz (±tolerance as per applicable standard), star rating the capacity of >10,465watt( > 9000 kcal/hour), three-phase AC supply, providing cooling, dehumidification, and air circulation functions conforming to IS-1391 (Part-II ) with all amendments, and shall be capable of efficient performance at outdoor ambient temperatures up to 50°C, with a minimum 5- year OEM warranty on both the compressor and PCB. The system shall be installed with S&F appropriate fixing arrangements as per OEM recommendations, including wall openings, mending well the damages and making necessary connections including T&P & labour etc as required complet in all respect as per the direction of EIC.Cooling Capacity- 14 kW (Minimum) , Air Flow Rate:600 CFM (Minimum)
(Make- Mitsubishi / Daikin / Voltas/ Blue Star) | 2 | Nos | 397 | ₹794 |
| 2Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for Tower AC system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 25 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : | |||||
| 2.1 | 5/8 inch or 15.8 mm dia (OD) (Soft drawn) as per standard BS864 & ANSIB 16.22 ( for suction line) | 32 | Mtr | 10 | ₹320 |
| 2.2 | 3/8 inch 9.5 mm dia (OD) (Soft drawn) Soft drawn) as per standard BS864 & ANSIB 16.22 ( for discharge line) | 32 | Mtr | 10 | ₹320 |
| 3 | Supply & laying hard Drawn PVC Drain Pipe 25 mm dia with proper supports & brackets as per direction EIC. | 15 | Mtr | 10 | ₹150 |
| 4 | S&F of 4.0 core 4.0 sq mm unarmoured copper cable for controlling indoor to outdoor units (FRLS type) (Make: Polycab/ Finolex/ KEI/ Gloster/ RR Kabel) | 32 | RM | 10 | ₹320 |
| 5 | Supplying, fabrication and fixing of MS u- channel of 6mm thick of size (75mm X 40 mm X 40 for installation of outdoor unit of ACs including drilling 2 nos holes in each channel inclu the same with cement concrete (1 :1 1/2:3) etc. fabbdcated with horizontal agle of 25mmx 25 mm x 6 mm supporting angle of 50mm x50mm x6 mm in each platform. The platform should be baricaded and set for ODU machine in outer angle transmitting the load centraly through 2 nos (50 mm x 50 mm x6 mm )angle increated in to the wall incl fiber sheet shade as per direction of EIC . The area of the platform is of suitable size as per machine configuration and load with addiquiet service acces & safe to cary out the maintenance of ODU as per direction of EIC. The design of platform structure to be approved by EIC, including painting the entire structure. | 143 | kg | 10 | ₹1,430 |
| 6Providing and fixing thermal insulation of ceiling (underdeck insulation) with Resin Bonded Rockwool conforming to IS:8183, density 48kg/m3,50mm thick, wrapped in 200G Virgin Polythene bags fixed to ceiling with metallic cleats (50x50x3mm)@60 cm and wire mesh of 12.5mm x 24gauge wire mesh for top most ceiling of building. | |||||
| 6.1 | Ceiling of top floor | 18 | sq mtrs | 10 | ₹180 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.52 MB
Tendernotice_2.pdf
PDF • 1.11 MB
2911.pdf
Tender Documents • 0.51 MB
Notice12.pdf
Tender Documents • 1.10 MB
BOQ_5099442.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .