| 1 | L1₹29.6 LAccepted-AOC NOT AVAILABLE | ₹29.6 L Quoted ₹30.8 L | L1 | Accepted-AOC BEING LOWEST |
| 2 | L2₹30.8 L+₹4,044 (0.13%)Rejected-Finance | ₹30.8 L+₹4,044 (0.13%) | L2 | Rejected-Finance BEING OTHER THAN LOWEST |
| 3 | L3₹32.5 L+₹1.7 L (5.47%)Rejected-Finance ROOM NO A 46 GALI NO 11 GANESH MURTHY NAGAR PART NO 3 CAPT PRAKASH PETHE MARG CUFFE PARADE COLABA MUMBAI 400005 | MUMBAI | MUMBAI | MAHARASHTRA | 400005 | ₹32.5 L+₹1.7 L (5.47%) | L3 | Rejected-Finance BEING OTHER THAN LOWEST |
| 4 | L4₹34.5 L+₹3.7 L (12.0%)Rejected-Finance F 402 AMBIKA APARTMENT PLOT A 9 SECTOR 20 NERUL W NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | ₹34.5 L+₹3.7 L (12.0%) | L4 | Rejected-Finance BEING OTHER THAN LOWEST |
| 5 | L5₹35.1 L+₹4.3 L (14.0%)Rejected-Finance B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | ₹35.1 L+₹4.3 L (14.0%) | L5 | Rejected-Finance BEING OTHER THAN LOWEST |
| Sl No | Description | Qty | Unit | Unity Enterprises L7 | jkconstruction L3 | SHRI SAI ENTERPRISES L5 | Advait Enterprises L4 | P LAXMI AND CO. L6 | NATH CONSTRUCTION L2 | Shetty Construction Co L8 | SHREE JAGDISH FURNITURE CO. L1 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply & fix in replacement of PVC(LLDPE) rectangular loft tank of net capacity 275 Ltr with gross capacity of tank at least 5% in excess of minimum net capacity including 03 Nos adopter with washer for inlet/outlet overflow pipe as per manufacturere s instruction and overall dimension as 995-1200mm length , 620-820mm with 285-485mm height , 300mm internal dia of hand hole,minimum wall thickness 2.75mm( weight of tank 11 Kgs) with lid cover complete all as specified and directed by Engineer-in- Charge. | 240 | Each | 2,500 ₹6,00,000 | 4,000 ₹9,60,000 | 3,000 ₹7,20,000 | 4,500 ₹10,80,000 | 2,100 ₹5,04,000 | 1,900 ₹4,56,000 | 3,200 ₹7,68,000 | 1,787 ₹4,28,880 Lowest |
| 2.00 | Supply and fix in replacement PVC profile suitable for 275 ltr loft tank including fixing of aluminium channel around the profile complete all as specified and directed. | 183 | Each | 1,500 ₹2,74,500 | 850 ₹1,55,550 | 1,000 ₹1,83,000 | 850 ₹1,55,550 | 500 ₹91,500 | 400 ₹73,200 Lowest | 900 ₹1,64,700 | 555 ₹1,01,565 |
| 3.00 | Supply, fixing and laying in repair/ replacement of CPVC pipes 15 mm nominal bore SDR 11 & Plain CPVC SDR 11 fittings such as nipple, union, socket, elbow, bends, tee, adopter e.t.c fixed to wall/floors/ceiling including work to be done up to 15 th floor in high rise buildings and low rise buildings in short piece/length all as specified and directed by Engineer-in-charge. | 100 | RM | 180 ₹18,000 | 150 ₹15,000 | 150 ₹15,000 | 150 ₹15,000 | 300 ₹30,000 | 250 ₹25,000 | 160 ₹16,000 | 115 ₹11,500 Lowest |
| 4.00 | Supply, fixing and laying in repair/ replacement of CPVC pipes 20 mm nominal bore SDR 11 & Plain CPVC SDR 11 fittings such as nipple, union, socket, elbow, bends, tee, adopter e.t.c fixed to wall/floors/ceiling including work to be done up to 15 th floor in high rise buildings and low rise buildings in short piece/length all as specified and directed by Engineer-in-charge. | 800 | RM | 200 ₹1,60,000 | 190 ₹1,52,000 | 200 ₹1,60,000 | 200 ₹1,60,000 | 350 ₹2,80,000 | 280 ₹2,24,000 | 280 ₹2,24,000 | 125 ₹1,00,000 Lowest |
| 5.00 | Supply and fixing in repair/ replacement of 15 mm bore internal steel water tubing, galvanised, Medium grade with all fittings such as nipple, union, socket, elbow, bends, fixed to wall including work to be done up to 15 th floor in high rise buildings in short piece/length, including breaking the existing brick wall for replacement of corroded GI pipe in/ on wall or concealed pipe and making good the disturbed surfaces to match previous structure with complete all as specified and directed by Engineer-in-charge | 120 | RM | 200 ₹24,000 | 138 ₹16,560 Lowest | 150 ₹18,000 | 138 ₹16,560 Lowest | 220 ₹26,400 | 200 ₹24,000 | 250 ₹30,000 | 145 ₹17,400 |
| 6.00 | Supply and fixing in repair/ replacement of 20 mm bore internal steel water tubing, galvanised, Medium grade with all fittings such as nipple, union, socket, elbow, bends, fixed to wall including work to be done up to 15 th floor in high rise buildings in short piece/length, including breaking the existing brick wall for replacement of corroded GI pipe in/ on wall or concealed pipe and making good the disturbed surfaces to match previous structure with complete all as specified and directed by Engineer-in-charge | 80 | RM | 230 ₹18,400 | 160 ₹12,800 Lowest | 200 ₹16,000 | 160 ₹12,800 Lowest | 250 ₹20,000 | 220 ₹17,600 | 350 ₹28,000 | 175 ₹14,000 |
| 7.00 | Supply and fixing in repair/ replacement of 25 mm bore internal steel water tubing, galvanised, Medium grade with all fittings such as nipple, union, socket, elbow, bends, fixed to wall including work to be done up to 15 th floor in high rise buildings in short piece/length, including breaking the existing brick wall for replacement of corroded GI pipe in/ on wall and making good the disturbed surfaces to match previous structure with complete all as specified and directed by Engineer-in-charge | 100 | RM | 260 ₹26,000 | 185 ₹18,500 Lowest | 250 ₹25,000 | 200 ₹20,000 | 280 ₹28,000 | 250 ₹25,000 | 450 ₹45,000 | 222 ₹22,200 |
| 8.00 | Supply and fixing in repair/ replacement of 40 mm bore internal steel water tubing, galvanised, Medium grade with all fittings such as nipple, union, socket, elbow, bends, fixed to wall including work to be done up to 15 th floor in high rise buildings in short piece/length, including breaking the existing brick wall for replacement of corroded GI pipe in/ on wall and making good the disturbed surfaces to match previous structure with complete all as specified and directed by Engineer-in-charge | 90 | RM | 350 ₹31,500 Lowest | 395 ₹35,550 | 400 ₹36,000 | 395 ₹35,550 | 400 ₹36,000 | 400 ₹36,000 | 620 ₹55,800 | 365 ₹32,850 |
| 9.00 | Supply and fixing in repair/ replacement of 50 mm bore internal steel water tubing, galvanised, Medium grade with all fittings such as nipple, union, socket, elbow, bends, fixed to wall including work to be done up to 15 th floor in high rise buildings in short piece/length, including breaking the existing brick wall for replacement of corroded GI pipe in/ on wall and making good the disturbed surfaces to match previous structure with complete all as specified and directed by Engineer-in-charge | 60 | RM | 460 ₹27,600 | 410 ₹24,600 Lowest | 500 ₹30,000 | 450 ₹27,000 | 500 ₹30,000 | 420 ₹25,200 | 700 ₹42,000 | 425 ₹25,500 |
| 10.00 | Supply and fix in replacement bronze pressure reducing valve suitable for 25 mm bore GI pipe with diaphram cover, spring clamps, cast iron body scatting and adjustable screws and stop valve of chromium plated carbon steel strainer, screw of stain less steel for domestic water supply, suitable for inlet pressure as per IS-7939, including GI pipe connection as required, the work to be carried out from G+14 floor on plain wall with necessary bamboo scaffolding complete all as specified and directed by Engineer-in-Charge. | 5 | Each | 2,500 ₹12,500 | 3,900 ₹19,500 | 1,000 ₹5,000 Lowest | 3,900 ₹19,500 | 1,500 ₹7,500 | 1,500 ₹7,500 | 2,500 ₹12,500 | 1,765 ₹8,825 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
12 Aug 2026, 6:50 pmClosed
GE (NW) NAVY NAGAR
GE NW NAVY NAGAR COLABA MUMBAI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI
WELCOME MAINTENANCE OF INTERNAL WATER SUPPLY PLUMBING AND ALLIED WORKS FOR OLD NAVY NAGAR AND NEW NAVY NAGAR AND RASHI AREA UNDER GE (NW) NAVY NAGAR, COLABA, MUMBAI
2026_MES_778854_1
8658/E8
Open Tender
Civil Works - Water Works
Item Rate
270 days
GE (NW) NAVY NAGAR, COLABA
Class D and Category a(ii)
8 documents required · 8 mandatory
₹500
GE (NW) NAVY NAGAR
₹70,000
12 Sept 2026
15 Jul 2026
14 Aug 2026
15 Jul 2026
12 Aug 2026
29 Jul 2026
15 Jul 2026 - 5 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply & fix in replacement of PVC(LLDPE) rectangular loft tank of net capacity 275 Ltr with gross capacity of tank at least 5% in excess of minimum net capacity including 03 Nos adopter with washer for inlet/outlet overflow pipe as per manufacturere s instruction and overall dimension as 995-1200mm length , 620-820mm with 285-485mm height , 300mm internal dia of hand hole,minimum wall thickness 2.75mm( weight of tank 11 Kgs) with lid cover complete all as specified and directed by Engineer-in- Charge. | 240 | Each | - | - |
| 2 | Supply and fix in replacement PVC profile suitable for 275 ltr loft tank including fixing of aluminium channel around the profile complete all as specified and directed. | 183 | Each | - | - |
| 3 | Supply, fixing and laying in repair/ replacement of CPVC pipes 15 mm nominal bore SDR 11 & Plain CPVC SDR 11 fittings such as nipple, union, socket, elbow, bends, tee, adopter e.t.c fixed to wall/floors/ceiling including work to be done up to 15 th floor in high rise buildings and low rise buildings in short piece/length all as specified and directed by Engineer-in-charge. | 100 | RM | - | - |
| 4 | Supply, fixing and laying in repair/ replacement of CPVC pipes 20 mm nominal bore SDR 11 & Plain CPVC SDR 11 fittings such as nipple, union, socket, elbow, bends, tee, adopter e.t.c fixed to wall/floors/ceiling including work to be done up to 15 th floor in high rise buildings and low rise buildings in short piece/length all as specified and directed by Engineer-in-charge. | 800 | RM | - | - |
| 5 | Supply and fixing in repair/ replacement of 15 mm bore internal steel water tubing, galvanised, Medium grade with all fittings such as nipple, union, socket, elbow, bends, fixed to wall including work to be done up to 15 th floor in high rise buildings in short piece/length, including breaking the existing brick wall for replacement of corroded GI pipe in/ on wall or concealed pipe and making good the disturbed surfaces to match previous structure with complete all as specified and directed by Engineer-in-charge | 120 | RM | - | - |
| 6 | Supply and fixing in repair/ replacement of 20 mm bore internal steel water tubing, galvanised, Medium grade with all fittings such as nipple, union, socket, elbow, bends, fixed to wall including work to be done up to 15 th floor in high rise buildings in short piece/length, including breaking the existing brick wall for replacement of corroded GI pipe in/ on wall or concealed pipe and making good the disturbed surfaces to match previous structure with complete all as specified and directed by Engineer-in-charge | 80 | RM | - | - |
| 7 | Supply and fixing in repair/ replacement of 25 mm bore internal steel water tubing, galvanised, Medium grade with all fittings such as nipple, union, socket, elbow, bends, fixed to wall including work to be done up to 15 th floor in high rise buildings in short piece/length, including breaking the existing brick wall for replacement of corroded GI pipe in/ on wall and making good the disturbed surfaces to match previous structure with complete all as specified and directed by Engineer-in-charge | 100 | RM | - | - |
| 8 | Supply and fixing in repair/ replacement of 40 mm bore internal steel water tubing, galvanised, Medium grade with all fittings such as nipple, union, socket, elbow, bends, fixed to wall including work to be done up to 15 th floor in high rise buildings in short piece/length, including breaking the existing brick wall for replacement of corroded GI pipe in/ on wall and making good the disturbed surfaces to match previous structure with complete all as specified and directed by Engineer-in-charge | 90 | RM | - | - |
| 9 | Supply and fixing in repair/ replacement of 50 mm bore internal steel water tubing, galvanised, Medium grade with all fittings such as nipple, union, socket, elbow, bends, fixed to wall including work to be done up to 15 th floor in high rise buildings in short piece/length, including breaking the existing brick wall for replacement of corroded GI pipe in/ on wall and making good the disturbed surfaces to match previous structure with complete all as specified and directed by Engineer-in-charge | 60 | RM | - | - |
| 10 | Supply and fix in replacement bronze pressure reducing valve suitable for 25 mm bore GI pipe with diaphram cover, spring clamps, cast iron body scatting and adjustable screws and stop valve of chromium plated carbon steel strainer, screw of stain less steel for domestic water supply, suitable for inlet pressure as per IS-7939, including GI pipe connection as required, the work to be carried out from G+14 floor on plain wall with necessary bamboo scaffolding complete all as specified and directed by Engineer-in-Charge. | 5 | Each | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
TENDERDOCUMENT.pdf
Tender Documents • 0.99 MB
BOQ_872348.xls
BOQ • 2.80 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .