Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹89.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹91.5 L+₹2.4 L (2.74%)Rejected-Finance 7G CORNFIELD ROAD KOLKATA 700019 | KOLKATA | KOLKATA | WEST BENGAL | 700019 | L2 | Rejected-Finance L2 | |
| 3 | L3₹95.0 L+₹5.9 L (6.60%)Rejected-Finance 159 KAILASH GHOSHI ROAD KOLKATA WEST BENGAL 700008 | KOLKATA | KOLKATA | WEST BENGAL | 700008 | L3 | Rejected-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
31 Oct 2020, 6:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE(E/M)-I, KMDA
OFFICE OF THE SUPERINTENDING ENGINEER (E/M)-I, E-M SECTOR, K.M.D.A. UNNAYAN BHAVAN, 6th FLOOR, SALT LAKE CITY, KOLKATA 700 091.
Design, Engineering, Supply, Storage, Installation, Commissioning, Trial Run Six Months Operation And Maintenance Of Raw Water Pumping Station Of Capacity 600 M3 Hr And Power Distribution System.
2020_KMDA_298471_1
SE (E/M)-I/3T-01/2017/451
Open Tender
Electrical Work/ Equipment
Item Rate
210 days
Uttarpara Municipality
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹1 L
OFFICE OF THE SUPERINTENDING ENGINEER (E/M)-I
9 Oct 2025
29 Sept 2020
2 Nov 2020
29 Sept 2020
31 Oct 2020
30 Sept 2020
9 Oct 2020
120 days
Amount
PART – A ( SUPPLY PART )
Supply ,Delivery at site and Storage of HSC Pump having a head discharge characteristic of 600m³/hr at a Head of 20 m with shaft, sleeves, guide , along spiders, discharge head, motor stool, pressure gauge, air release valve etc. total complete as per the specification & as required as per site condition.
Supply ,Delivery at site and Storage of 45KW,0.415KV,50Hz,TFEC,SCIM,class F insulation, temp rise restricted ,to Class-B, pump duty motor, all complete as per the specification .
Supply ,Delivery at site and Storage of all necessary accessories like MCCBs, starters, SFUs, APFC along with all meters, instruments, termination as required all complete to provide all the power requirements of the Raw Water Pump House for augmentation of the existing M.V. Panel at WTP/ Pump House with & as per the specification.
Supply, Delivery at site and Storage of Electrically operated Sluice Valve 350 mm diameter at Pump individual suction as per the specification.
Supply ,Delivery at site and Storage of the Butterfly valves of 300mm size at Pump individual delivery as required as per the specification
Supply , Delivery at site and Storage of the NRV 300 mm at Pump individual delivery as per the specification.
Supply , Delivery at site and Storage of the Electrically operated Butterfly Valve 400 mm at Pump common suction manifold inlet as per the specification
Supply ,Delivery at site and Storage of the Electrically operated Butterfly Valve 350 mm at Pump common delivery manifold as per the specification
Supply ,Delivery at site and Storage of DJ 400 mm at Pump common suction manifold inlet as per the specification
Supply , Delivery at site and Storage of DJ 350 mm at Pump common delivery manifold as per the specification.
Supply , Delivery at site and Storage of DJ 350 mm diameter at Pump individual suction as per the specification.
Supply , Delivery at site and Storage of DJ 300 mm diameter at Pump individual delivery as per the specification.
Supply ,Delivery at site and Storage of 164m3/hr at 8.5 meter ,24.8 inch of mercury, vacuum capacity vacuum pump with 10 HP motor with pipe line network, foundation, fabrication and other allied work, all complete as per the specification .
Supply, Delivery at site and Storage of double flanged MS pipes of 300 mm , 350 mm & 400 mm size to complete the pump individual delivery, suction piping and common delivery & suction manifolds as required including MS reducer, enlarger, specials of suitable size including vacuum/ combined/pressure gauges at individual suction side, delivery side, Common manifold and pressure transmitters at individual delivery & common delivery manifold for all the Pumps as per the specification.
Supply ,Delivery at site and Storage of RCC chair thrust blocks of suitable size as required to complete the pump supports, valve supports, piping layout etc including M.S. Cable tray, rack, angle, channel etc all complete as per the specification.
Supply ,Delivery at site and Storage of all LT, Control & Signal cables as required to complete the entire pumping station along with termination kits, and pipe protections, as required etc. as per the specification
Supply, Delivery at site and Storage of internal and external illumination system complete with switch boards, switches, MCBs, DB, light fittings, fans, exhaust fans, plug points, power plugs, poles etc. as required for proper illumination as per the specification.
Supply & delivery at site and storage of earthing equipment as per specification and all the other equipments required to comply with latest I.E. Rules & Lightning arrestor along with earth strip and earth electrodes all complete as per specification and all other equipment required to comply with latest I.E. Rules.
Supply , Delivery at site and Storage of fire extinguishers along with sand buckets as required as per the specification.
Supply , Delivery at site and Storage of rubber mat, hand gloves, shock treatment chart etc as per the specification.
Supply , Delivery at site and Storage of 3 MT capacity Chain pulley Block with monorail & accessories as per the specification.
Supply ,Delivery at site and Storage of Ultrasonic level indicator with allied system as per the specification
Supply ,Delivery at site and Storage of SCADA System, M340 High Power Standard PS, Mod Bus TCPIP communication & IO System for Raw Water Pump House with PAC PLC IO MODULE- for CCR PLC PANEL--1set & Centralized Supervisory Control and Data Acquisition Software for up gradation of the existing SCADA System and integration of the new system with the existing one, as per the specification.
Supply ,Delivery at site and Storage of Turbidity Analyzer consists of 1) CUS51D - Sensor with cable2) CM442 - Transmitter3) CYA112 - Dip Stick Assembly as per the specification
Supply ,Delivery at site and Storage of ring ventilation system as per the specification
Supply ,Delivery at site and Storage of full bore electromagnetic type flow meter & indicator with allied system as per the specification
PART-B (INSTALLATION PART)
Installation at site of HSC Pump having a head discharge characteristic of 600m³/hr at a Head of 20 m with shaft, sleeves, guide , along spiders, discharge head, motor stool, pressure gauge, air release valve etc. total complete as per the specification & as required as per site condition.
Installation at site of 45 KW,0.415KV,50Hz,TFEC,SCIM,class F insulation, temp rise restricted ,to Class-B, pump duty motor, all complete as per the specification & direction of the E.I.C.
Installation at site of all necessary accessories like MCCBs, starters, SFUs, APFC along with all meters, instruments, termination as required all complete to provide all the power requirements of the Raw Water Pump House for augmentation of the existing M.V. Panel at WTP/ Pump House with & as per the specification & direction of the E.I.C.
Installation at site of Electrically operated Sluice Valve 350 mm diameter at Pump individual suction as per the specification & direction of the E.I.C.
Installation at site of the Butterfly valves of 300mm size as required at Pump individual delivery as per the specification & direction of the E.I.C.
Installation at site of the NRV 300 mm at Pump individual delivery as per the specification & direction of the E.I.C.
Installation at site of the Electrically operated Butterfly Valve 400 mm at Pump common suction manifold inlet as per the specification & direction of the E.I.C.
Installation at site of the Electrically operated Butterfly Valve 350 mm at Pump common delivery manifold as per the specification & direction of the E.I.C.
Installation at site of DJ 400 mm at Pump common suction manifold inlet as per the specification & direction of the E.I.C.
Installation at site of DJ 350 mm at Pump common delivery manifold as per the specification & direction of the E.I.C.
Installation at site of DJ 350 mm diameter at Pump individual suction as per the specification & direction of the E.I.C.
Installation at site of DJ 300 mm diameter at Pump individual delivery as per the specification & direction of the E.I.C.
Installation at site of 164m3/hr at 8.5 meter ,24.8 inch of mercury, vacuum capacity vacuum pump with 10 HP motor with pipe line network, foundation, fabrication and other allied work, all complete as per the specification & direction of the E.I.C.
Installation at site of double flanged MS pipes of 300 mm , 350 mm & 400 mm size to complete the pump individual delivery, suction piping and common delivery & suction manifolds as required including MS reducer, enlarger, specials of suitable size including vacuum/ combined/pressure gauges at individual suction side, delivery side, Common manifold and pressure transmitters at individual delivery & common delivery manifold for all the Pumps as per the specification.
Installation at site of RCC chair thrust blocks of suitable size as required to complete the pump supports, valve supports, piping layout etc including M.S. Cable tray, rack, angle, channel etc all complete as per the specification & direction of the E.I.C.
Installation/ Laying at site of all LT, Control & Signal cables as required to complete the entire pumping station along with termination kits, and pipe protections, as required etc. as per the specification
Installation at site of internal and external illumination system complete with switch boards, switches, MCBs, DB, light fittings, fans, exhaust fans, plug points, power plugs, poles etc. as required for proper illumination as per the specification.
Installation at site of earthing equipment as per specification and all the other equipments required to comply with latest I.E. Rules & Lightning arrestor along with earth strip and earth electrodes all complete as per specification and all other equipment required to comply with latest I.E. Rules.
Installation at site of fire extinguishers along with sand buckets as required as per the specification & direction of the E.I.C.
Installation at site of rubber mat, hand gloves, shock treatment chart etc as per the specification & direction of the E.I.C.
Installation at site of 3 MT capacity Chain pulley Block with monorail & accessories as per the specification & direction of the E.I.C.
Installation at site of Ultrasonic level indicator with allied system as per the specification & direction of the E.I.C.
Installation at site of SCADA System, M340 High Power Standard PS, Mod Bus TCPIP communication & IO System for Raw Water Pump House with PAC PLC IO MODULE- for CCR PLC PANEL--1set & Centralized Supervisory Control and Data Acquisition Software for up gradation of the existing SCADA System and integration of the new system with the existing one, as per the specification.
Installation at site of Turbidity Analyzer consists of 1) CUS51D - Sensor with cable2) CM442 - Transmitter3) CYA112 - Dip Stick Assembly as per the specification & direction of the E.I.C.
Installation at site of ring ventilation system as per the specification & direction of the E.I.C.
Installation at site of full bore electromagnetic type flow meter & indicator with allied system as per the specification & direction of the E.I.C.
Testing & Commissioning of the whole installation including Trial Run of Pumps for one month with 8 hrs. at a stretch operation as per specification & direction of E.I.C.
Operation & Maintenance of the whole installation for a period six months ( after trial run ) deploying adequate number of working personnel for round the clock operation as per requirement, specification & direction of E.I.C.
CONCORD ENGINEERING
POWER INDIA
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .