Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.2 CrAccepted-AOC AH 73 2 5TH STREET 7TH MAIN ROAD SHANTHI COLONY ANNA NAGAR CHENNAI 600 040 | CHENNAI | TAMIL NADU | 600040 | ₹3.2 Cr | L1 | Accepted-AOC The lowest and negotiated tenderer |
| 2 | L2₹3.2 Cr+₹3.0 L (0.94%)Rejected-AOC | ₹3.2 Cr+₹3.0 L (0.94%) | L2 | Rejected-AOC Unsuccessful tenderer |
| 3 | L3₹3.2 Cr+₹6.9 L (2.17%)Rejected-AOC NO 2 15 SANTHIYUR ATTAYAMPATTI POST MALLUR VIA SALEM DISTRICT 636 203 | NAMAKKAL | TAMIL NADU | 636203 | ₹3.2 Cr+₹6.9 L (2.17%) | L3 | Rejected-AOC Unsuccessful tenderer |
| 4 | L4₹3.5 Cr+₹33.6 L (10.6%)Rejected-AOC 53 MIDDLE STREET ARUMALAI TIRUKOILUR VILLUPURAM DISTRICT | VILLUPURAM | TAMIL NADU | 604001 | ₹3.5 Cr+₹33.6 L (10.6%) | L4 | Rejected-AOC Unsuccessful tenderer |
Tender Value
Refer Docs
EMD Value
₹2.0 L
Closing Date
21 Mar 2025, 6:00 pmClosed
The Superintending Engineer/TNPHCL/NC/Salem
The Superintending Engineer/TNPHCL/North Circle, No.1 and 7, Inspectors quarters, PGR Line, Behind CPO Building, Annadhanapatty, Linemedu, Salem 636 006
Construction of Thozhi Working Womens Hostel building (50 beds G plus 2) with development works at Govt. Services home Campus, Cuddalore in Cuddalore District.
2025_TNPHC_531013_1
SE/NC/DB/614/2025
Open Tender
Civil Works
Lump-sum
240 days
Cuddalore
refer tender documents
7 documents required · 7 mandatory
₹0
₹2.0 L
17 Apr 2025
8 Mar 2025
24 Mar 2025
8 Mar 2025
21 Mar 2025
8 Mar 2025
Amount
1.1 : Earth work excavation in all soils (including refilling) a. 0 to 2 mt.
1.5 : Earth work excavation for Open foundation (excluding refilling) a. 0 to 2 mt.
b. 2 to 3 mt.
1.6 : Earth work excavation for Open foundation for drains (excluding refilling) width upto 1.25 m a. 0 to 2 mt.
13.1 : Filling with Excavated Earth
21.2 : Teak wood Wrought & Put up a. T.W. over 2 m & below 3 m
b. T.W. below 2 m length.
23.3 : S&F of Magnetic door catches
24 : Manufacturing & supply of steel windows (Weight basis)
25 : M.S.Holdfast
30 : Ellispattern
31 : Weathering course
37.1 : White washing 3 coats (slaked)
39 : M.s Grills
40 : Painting - New "wood work"
41 : Painting - New "iron work"
46 : S & F 20 mm dia Alu. Hanger Rod
47 : S & F Alu Towel rail 75 cm long
48 : S & F 5 pin Coat stand
49 : S & F chromium plated 8 guage Picture Hook
50.3 : Supply and planting avenue trees
50.4 : Providing Tree guard
51.2: Supply and erection of Rotational Moulded Polyethylene water storage tanks (HDPE Cylinderical vertical type) for outdoor use having capacity of 1000 litres
52.1 : Supplying and fixing of 20mm dia "B" Class GI pipe for Hot water line (Fully Concealed in walls)
53.3 : C.I. Steps ( 5 kg)
Electrical arrangements 72 : Box type Fibre Fan hook
74 : Charges for fixing of "Fan"
76 : 8 SWG wire
78 : Earthing Station IS3043 (Type I)
86 : Anti termite treatment
112 : S & F of Exhaust Fan 300 mm dia
238 : Anticorrosive treatment for steel grills
ANNEXURE-I 2.1.1 : Supplying and filling Gravel
2.1.3 : Filling crushed stone sand
3.1.1 : C.C.1:5:10 for Foundation & Basement (using crushed stone sand)
3.2.1 : P.C.C. 1:2:4 for Foundation & Basement and other similar works (using crushed stone sand)
3.3.1 : P.C.C. 1:8:16 using 20 mm broken brick jelly (using crushed stone sand)
6.2.1.1 : Brick work in C.M. 1:5 (F& B) with Admixture using Fly ash bricks of size 230x110x70mm having the compressive strength of not less than 100 Kg/CM²
8.3.1.1 : Standardised concrete Mix M30 Grade concrete. (using crushed stone sand) a) In Foundation and Basement.
b) In Stilt / Ground Floor
c) In First Floor.
d) In Second Floor.
e) In Third Floor.
9.2.1.1: Brick work in Cement Mortar 1:6 (One of cement and six of Crushed stone sand) with Admixture using Fly ash bricks of size 230x110x70mm having the compressive strength of not less than 100 Kg/CM² for superstructure in the following floors a. In Ground floor / Stilt floor
b. In First Floor
c. In Second Floor
d. In Third Floor
10.2.1.1 : Brick partition wall in Cement Mortar 1:4 (One of cement and four of Crushed stone sand with Admixture) 110mm thick for super structure in the following floors using Fly ash bricks of size 230x110x70mm having the compressive strength of not less than 100 Kg/CM² in the following floors a. In Foundation and basement
b. In Stilt / Ground Floor
c. In First Floor
d. In Second Floor
e. In Third Floor
11.2.1.1 : Brick partition wall in Cement Mortar 1:4 (One of cement and four of Crushed stone sand with Admixture) 70mm thick for super structure in the following floors using Fly ash bricks of size 230x110x70mm having the compressive strength of not less than 100 Kg/CM² for superstructure in the following floors a. In Stilt / Ground floor
b. In First Floor
c. In Second Floor
15.2.1: Cuddappa slab 40 mm tk.for C/B slab. (using crushed stone sand) a. In Ground Floor
b. In First Floor
c. In Second Floor
16.1.2 : Precast Jally Ventilator 50mm thick.Using standardised M30 grade concrete Mix. (using crushed stone sand) a. In Ground Floor
18.1 : Formwork using M.S.Sheet a. For Column footings, plinth beam, Grade beam, Raftbeam, Raft slab etc.,
b.Plain surfaces such as Roof slab,floorslab,Beams,lintels,lofts,sill slab,staircase,portico slab and other similar works
c.For Square and rectangular columns and small quantities
d.For Vertical wall
f. Curved surface
21.5.5.1: Supplying and fixing of solid core flush door shutter of thickness 35mm a) Door size 1000mm x 2100mm (Single Leaf)
22.3.3 : T.W. frame & T.W styles & rails with BWR double leaf shutters for Cup board/ward robes including two coat enamel paint & one coat primer.
23.2.1 : 4mm thick pin headed Glass panels with Aluminium beedings
26.1 : Flooring in C.C.1:5:10 (using crushed stone sand)
28.1 : Floor plastering in C.M. 1:4, 20 mm tk. (using crushed stone sand) with plasticizer
29.8.1 : Glazed tiles using Grout (Tile Joint Filler) (using crushed stone sand)
29.9.1 : Floor ceramic tiles using Grout (Tile Joint Filler) (antiskid) (using crushed stone sand)
32.1.1: Finishing top of roof with one course of Hydraulic Pressed Tiles of approved superior quality of size 23cmx 23cmx16 to 18mm thick laid over weathering course in cm 1:3 (One of cement and three of crushed stone sand) 12mm thick mixed with Water proofing compound at 2%
33.1 : Plastering in C.M. 1:5, 12 mm tk. (using crushed stone sand) with plasticizer
34.1 : Plastering in C.M. 1:4, 12 mm tk.(using crushed stone sand) with plasticizer
35.1.1 : Plastering 1:3, 12mm with WPC (using crushed stone sand)
35.1.2 : Spl. Ceiling plastering in C.M. 1:3, 10 mm tk. (using crushed stone sand) with plasticizer
36.1 : Cement mortar Border in C.M. 1:5, 12 mm tk. (using crushed stone sand) a. 150 mm wide
b. 75 mm wide
c. 50 mm wide
38.7 : Plastic Emulsion PAINT including primer for inner walls
38.7.1 : Plastic Exterior Emulsion PAINT including primer for outer walls
43.1.1 : Supply & Fabrication of Mild steel / RTS grills (without cement slurry) for all sizes of rods.(using PVC insulated binding wire)
44.2.1.1 : Rain water harvesting using defunct borewell and providing perforated cover slab a). Providing pit (M30)
b) Augering 30cm dia
44.6.1 : PVC SWR 110 mm dia with ISI mark type- A for Rain water down fall pipe (UPVC special clamp)
50.2.1 : Providing precast Kerb stone in C.C. 1:3:6, 450 x 300 x 150mm (using crushed stone sand)
50.5.1 : Supplying. Fabricating and erection of M.S Scheme Name board (using crushed stone sand)
50.6.1 : Precast slab 50 mm tk.in C.C. 1:3:6 with fibre (using crushed stone sand)
52.1.1 : PVC Water supply (ASTM) with UPVC Specials a. 32 mm dia
b. 25 mm dia
c. 50 mm dia
52.4.1 : 20mm dia PVC water supply ASTM pipe with UPVC Specials (fully consealed in walls)
53.4 : S&F of C.I Manhole cover 60 x 60 cm (50kg weight )
53.5.2 : Wash Hand Basin of size 550 x 400 mm (White without Pedestal)
54.1.1 : S & F of 15mm dia half turn CP long body tap
54.2.1 : S & F of 15mm dia half turn CP short body tap
56.3.1: S&F of Indian Water Closet white glazed (Oriya type) of size 580 x 440mm with PVC SWR grade P' or "S' trap - In G.F.(using crushed stone sand)
56.4.1 : S&F of Indian Water Closet white glazed (Oriya type) of size 580 x 440mm with PVC SWR grade P' or "S' trap - Other than G.F.(using crushed stone sand)
57.1.2 : S & F of E.W.C (White) 500mm with PVC SWR grade "P" or "S" Trap (using crushed stone sand)
58.3 : PVC SWR pipe (Soil line) with ISI mark - type 'B'. a. 110 mm dia.
b. 75 mm dia.
58.4: Supplying, Laying & Concealing the 50mm dia PVC ( SWR) pipe with ISI mark type - 'B' with relevant specials.
59.5.1 : Gully Trap using Kiln Burnt Country bricks of size 22 x 11 x 7 cm (8 3/4" x 4 1/4"x 2 3/4") (using crushed stone sand)
60.1 : PVC Nahani trap (4way/2way)
61.3 : UPVC Non Pressure pipe of SN8 SDR 34 (S 16.5) as per IS 15328/2003 a. 110 mm UPVC Non Pressure pipe
b. 160 mm UPVC Non Pressure pipe
c. 200 mm UPVC Non Pressure pipe
64.1.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990. (using PVC Box, Fire retardant Box) a. Light point with ceiling rose
b. Light point without ceiling rose
c. Calling bell point with Buzzer/Calling bell
65.1.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for Fan point. (using PVC Box, Fire retardant Box)
66.1.1: Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for Staircase Light Point. (using PVC Box, Fire retardant Box)
67.1.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point @ Switch Board Itself. (using PVC Box, Fire retardant Box)
68.2.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point @ Convenient Places. (using PVC Box, Fire retardant Box)
69.1.1: 15 Amp. Power plug (using PVC Box, Fire retardant Box)
71.2 : Supplying and fixing of 32 AMPS Triple pole main switch with fuse and neutral link
71.3: Supplying and fixing of 63Amps triple pole main switch with fuse and neutral link
75.1.2 : Supply and delivery of 48" (1200 mm) Fan with ISI mark with Eletronic Dimmer
77.5 : Run of 2 Wires of 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990.
77.6 : Run of 2 Wires of 4 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990.
77.7 : Run of 2 Wires of 2.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990.
77.8 : Run of 2 Wires of 6 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990.
79.2.1: 3 Nos. of 32 amps fuse unit
80.1: S & F of 450 x 375 x 20mm thick TW plank
87.1: Supplying and delivery of Three phase ELCB/RCCB
90.1: Providing additional strutting to centering of plain surface
98.5.4: TW Panelled door shutter with brass fittings (Double leaf) a. 1800mm x 2400mm.
344.2 : S&F of Bevelled edge mirror 500 x 400 x 5.5mm
361.1 : Concrete designer tiles flooring (using crushed stone sand)
361.5.1: Supplying and fixing of Stain Free Nano Polish colour Vitrified Tiles of size 60cmx60cmx8mm for flooring (using crushed stone sand)
379.4.2.1: Supply and fixing of superfine polished with machine cut edges (jet black) Granite slab of size 4'x2', 18 to 20mm thick for Kitchen arrangement (using crushed stone sand) a. In Ground floor
b. In First floor
c. In Second floor
379.4.2.2: Supplying and laying of Granite slab of size 4'x2', 18 to 20mm thick (Satharlic Grey/ Paradisc) for flooring (Super fine polished with machine cut edges) in C.M 1:3 (using crushed stone sand)
383.4: Providing double nosing to the edges of granite slab of 18 to 20 mm thick including labour, power consumption, tools and plants required, true to horizontal in all floors in the laboratory work table and as directed by the departmental officers.
384 : S&F of PVC flushing cistern 10 litres capacity
448.2: Supply and fixing 32mm dia PVC Tee with end cap
828.1 : Supply and laying of Hard core layer 300mm consolidated thickness (10 Sqm x 0.3m thick= 3.0 cum)
ANNEXURE-II: A1: Supply and fixing of fan rod of 0.60m height, including the cost of material and fixing charges etc all complete and as directed by the departmental officers.
A2: Providing Rain Water Harvesting well ring circular shape of 90cm dia, 60cm depth,50mm thick using M30 grade concrete including steel fabrication.
A3: Supply and Laying of Granite wall cladding (Ruby Red or Satharlic Grey or Jet Black) of 10mm thick in C.M 1:2 (using crushed stone sand) Including Cost of Materials, Labour charges etc., all complete and as directed by the departmental officers. (The colour and Quality should be got approved from the Executive Engineer before use)
A4: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free.
A5: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free.
A6: Supply and fixing of UPVC Sliding Window (Two track)
A7: Supplying, delivery and fixing of 83mm tk rubber moulded hydraulic pressed paver block including conveyance charges, laying of 83mm thick paver block
A8: Supplying and fixing of PVC trims / Corners beeding suitable colour in toilet wall cladding in all floors including cost of all materials, Labour charges for fixing in position, cutting the required size wherever necessary, finishing etc., all complete and as directed by the departmental officers. (The Material quality & brand should be got approved from the Executive Engineer before use).
A9: Providing Wallputty (One coat) for newly plastered surface
A10: Supplying and applying of two coats of putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothly with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing
A11: Providing water proofing treatment for the toilet sunken portion with epoxy coat including cost of materials and labour charges etc,. all complete and as directed by the Departmental Officers.
A12: Providing and applying Texture paint finish for exterior / interior surface as per Manufacturers specification and as directed. Application of primer by diluting the texture compound by mineral on the plastered surface and apply final two coats of exterior / interior emulsion on the primer. Rate including all brush, ladder, scrapping, washing, materials, labour charges, wastages , cleaning, necessary lead and lifts, scaffolding, stagging, before painting as complete with all respects complying with relevant standard specification and as directed by the departmental officers. (Internal surfaces)
A13: Supplying and fixing of special type mirror of size 1000x780mm of approved quality and variety etc the rate includes cost of all material and labour charges etc compete.
A14: Supplying and fixing of UPVC 200mm dia Exhaust fan fixing in the store and record of approved ISI quality etc, all complete and as directed by the departmental officers., (The quality and brand should be got approved from Executive Engineer before use).
A15: Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations.
A16: Supply and fixing of hydraulic door closer of various sizes of approved quality using Aluminium Extruded Section Body Tubular Type Universal Hydraulic Door Closer with Double Speed Adjustment like HARDWYN make) ‘GAZEL’ (or) Equivalent (with ISI Monogram)
A17: Supply & Fixing of WPC solid door frame extruded with size 75mm x 50mm. The inner core made of rigid WPC compound with minimum shore hardness of 55, and Bulk Density 800 Grms / Cub.Mt.. The frame shall be fixed onto the wall using 8 x 100mm long M.S fastener Screw fitted with polymeric nylon sleeve. A minimum of 4nos screws to be provided for each vertical member.Supply & Fixing of 25mm (+/- 1mm) thick WPC Decora Door which is extruded as a single core door with Lead-Free compound. The door is designed homogeneously by Smooth Routing and 3D embossed grains on one side. The other side of the door shutter shall be plain mat finish. The door must be completely made by machine, without any post-production fabrication. The Solid WPC board shall have minimum Bulk Density 650 KG/ Cub.Mt. The door is suggested to be hinged to the frame with minimum of 5 inch butt hinges of SS make. (Qute/Equivalent)
A18: Supplying and fixing in position of colour galvalume sheet of 0.47mm thick as ridge piece inclusive of overlap length labour charges and nuts, bolts etc., all complete and as directed by the departmental officers. (the quality and the brand of material should be got approved by the executive engineer before use)
A19: Providing Cornice Work for Gyp Board False Ceiling including cost of all materials and labour charges etc., all complete and as directed by the departmental officers.
A20: Supplying, fabricating, erecting and fixing of 12mm thick desiged GYP Board false ceiling arrangements with required aluminum chanel including labour charges, chanel, etc., all complete and as directed by the departmental officers.
A21: Supplying and fixing of CP Angle Cock Tap including cost of all materials and labour charges etc., all complete and as directed by the departmental officers.
A22: Supplying and fixing of CP Shower Arm 9" long with overhead shower rose including cost of all materials and labour charges etc., all complete and as directed by the departmental officers.
A23: Supplying and erecting in position of following liters capacity Industrial Model Reverse Osmosis Water-cum- Purifier to deliver Potable Water with World Health Organisation (WHO) Standards with following accessories. (a) MS Skid - 1 No. (b) Media 11054 No. Vessel with 20 nb Multiport Valve (with Media Pubble and Fine Sand and Activated Carbon Filling) set (c) Feed Pump 0.50 HP – 1 No. (d) Vertical Pump 2-9, 2.00 HP / Single Phase – 1 No. (e) Membrane 40 x 40 filmtech (or) equilaents / Osmonic (USA) - 1 No. and Membrane Pressure Vessel 40 x 40 -1 No. & Pressure Gauge - 2 Nos. (f) Flow Meter - 1 No. 20” Filter with Housing - 1 No., Low Pressure Switch - 1 No., Level Switch - 1 No. & Necessary CPVC Pipes and Fittings. The system shall be provide with Two Panel Control System with necessary Stainless Valves and Fittings and Float Control etc. The rate should be inclusive of all civil works, wherever necessary to install the System in position and intact. 50 Litres
A24: Supplying and Delivery of 2 T.R Split type AC unit 5 Star rated with all accessories etc., all complete and as directed by the departmental officers.
A25: Supplying and fixing of 5 KVA capacity Automatic Voltage Stablizer with time delay relay etc., all complete and as directed by the departmental officers.
A26: Supply and laying of 5/8" and 3/8" copper pipe (Extra beyond 3 metres supplied with AC unit) etc.,all complete and as directed by the departmental officers.
A27: Supplying and fixing of MS stand for fixing Outdoor Unit etc., all complete and as directed by the departmental officers.
A28: Design, Supply, Delivery, Installation,Testing and Commissioning of Passenger Lift (Brand: Johnson / Kone / OTIS or equivalent) of capacity 8 Persons with 3 Floors / 4 Stops / STAINLESS STEEL (1.5 mm) Car Cabin as per the following specifications Three phase EB power supply should be get from the TNEB for installation and testing etc for completion of work.
A29: Annual Maintance Charges for lift For First One Year (Free) For Second Year @ 5% of the Contract Value
A30: Vision Panel in Passenger Lift, Bed- Cum Passanger lift, Stretcher-cum-Passenger lift.
A31: Supply, installation, testing and commissioning of 25 KVA Diesel Generator set Erection, Testing and commissioning of 25 KVA Diesel generator set. Insulation for the residential silencer (supply of residential silencer to be included under item for DG Sets)
A32: Supplying and fixing of LED bulbs suitable for fixing it to pendent / bakelite battern holder of best approved variety a) 9 watts LED bulb
b) 12 watts LED bulb for bulk head fittings
A33: Supplying and fixing of 18W LED TUBE LIGHTS 4' long with necessary fittings and charges for assembling and fixing
A34: Supply and fixing of LED Bulk head fitting for 12W LED Bulb
A35: Supplying and fixing of 25W LED Street light with necessary fittings (Superior variety) Charges for fixing 25W LED lamp street light fittings
A36: Supplying and fixing of 6W Spot light, including cost of materials, labour charges for fixing and necessary connection etc., all complete and as directed by the departmental officers.
A37: Supplying and fixing of Sheraboard 12mm tk Closing with necessary Aluminium Channel Supports, MS Chanel, brackets and Screws including Scaffolding, Labours etc all Completed and as directed by the departmental officers.
A38: Structural Glazing: Providing and fixing structural glazing fabricated from roll formed sections made of galvanized steel colour coated (Base steel as per IS 513 of ‘D’ quality, galvanized as per IS 277 with Zinc of 120 grams / sqm.) with total coated thickness of 0.72mm. The glass holding section made of 304 grade SS of 0.6mm thick. Galvanized steel sections are to be used as stiffeners inside the colour coated steel / powder coated sections as per the design requirement. Design calculations are made to suit wind pressures as given in IS 875. Paint specifications: Primer coat with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer of 5-7 microns or powder coated with pure polyester powder upto 50-60 microns thick. Dimensions: of 37 x 53mm should be of 37 x 37mm for top and bottom grids in between should be of 37 x 18mm.
A39: Supplying and fixing of MS pipe with 3.6mm thick including cost of all materials and all labour charges etc., all complete and as directed by the departmental officers.
A40: Drilling the bore well 150mm dia and anywhere in Cuddalore district including transportion from one place to another with in Tamil nadu in alluvial soil sedimentary strata of sand stone shale pebble boulders etc by first taking a pilot bore of 140mm/150mm dia and then on laying to required dia direct or reverse rotary method circulation method using rotary rings and labour and drilling at site including all charges as per the direction by the departmental officers. a) From 0 mtr and upto 100mtrs depth below GL
b) From 101 mtrs and upto 210mtrs below GL
A41: Reaming 140/150 mm dia pilot bore to 300mm dia bore as directed by the departmental officers. i) From 0 m upto 60 m Depth ending from ground level
ii) From 60 m upto 90 m Depth ending from ground level
iii) From 90 m upto 120 m Depth ending from ground level
iv) From 120 m upto 150 m Depth ending from ground level
v) From 150 m upto 180 m Depth ending from ground level
vi) From 180 m upto 210m Depth ending from ground level
A42: Labour charges for inserting PVC casing pipes (With slotted/plain pipes) in the drilling holes including the jointing pipes with PVC couplerwith cement paste etc complete as per the direction by the officers.
A43: Supply and delivery of Nylon Rope for Bore-well including cost of materials and labour charges etc., complete as directed by the departmental officers.
A44: Supply and delivery of the following dia PVC heavy duty casing pipes of 15 kg/cm² and necessary special of best approved quality etc complete. a) 165 mm dia outer PVC Plain pipes
b) 165 mm dia outer PVC slotted pipes
c) 165 mm dia outer PVC bottom dummy
A45: Labour charges for developing the bore by air compressor of capacity 600 cfn. Using drill rods/holes with required size pipes for various capacity compressor including transportion, labour charges and fuel charges for air compressor as directed by the departmental officers.
A46: Supply and delivery of clear water vertical wet type 5 HP submersible pumpset without panel board suitable for 150mm dia borewell conforming to IS 8034/2002 as amended thereafter and BEE 3 Star Rated capable of discharging noted LPM against head of water column due to all causes.
A47: Supply and delivery of 3 HP Open well Submersible pump set without panel board conforming to IS 14220 /2002 and as amended thereafter and BEE 3 Star Rated capable of discharging the following duties due to all causes. Duty - 50 LPM X 50M
A48: THREE PHASE PANEL BOARD- D.O.L WITH TWO LEVEL GUARD AND AUTO START Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) For 3 HP
A49: THREE PHASE PANEL BOARD- D.O.L WITH TWO LEVEL GUARD AND AUTO START Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) For 5 HP
A50: Labour charges for the erection of submersible pumpset in borewell / openwell including fixing and jointing submersible cable with proper clamps upto the starter. Upto 5 HP
A51: Supply and delivery of 3 core 4 sqmm 1100V grade copper UG flat cable of best and approved quality having ISI mark etc., all complete
A52: Supplying and delivery of following dia "U" PVC column pipes with ISI mark a) 50mm dia UPVC column pipe
A53: Supplying, laying, fixing and jointing the following UPVC pipes as per ASTM-D-1785 of schedule (Below Ground level) a) 50 mm PVC pipe 10 Kg/cm2
A54: Supplying and delivery of following dia GI, GM, CI, PVC, UPVC and MS specials of best and approved quality having ISI mark etc., all complete and as directed by the departmenal officers. (The qualiy of the GI, GM & UPVC specials should be got approved by the Executive Engineer before use) a) 50mm dia UPVC Ball valve
b) 32mm dia UPVC Ball valve
c) 25mm dia UPVC Ball valve
d) 50mm dia UPVC Union
e) 50mm dia UPVC Bend
f) 50mm dia UPVC Elbow
g) 50mm x 40mm dia UPVC reducer
h) Supplying and fixing of 50mm dia adopter (SS) for connecting submersible pumpset with UPVC pipe etc., all complete
i) Supply & fixing of borewell MS Clamp sets suitable for 150mm dia borewell etc., all complete
j) 80mm dia GI Bend
k) 50mm dia GI Elbow
l) 50mm dia GI Hex Nipple
m) 50mm dia GI Union
n) 50mm dia GI Non Return valve
o) 50mm dia GI flange set
p) 50mmx32mm dia GI reducer
q) 50mm dia GI Bend
r) 50mm dia GI Tee
s) 50mm dia GI Coupling
A55: Supply and Laying of following LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good ,including cost of materials and transportation charges etc all complete and as directed by the departmental officers a) 3.5 core 95 sqmm LTUG cable
b) 3.5 core 25 sqmm LTUG cable
c) 4 core 16 sqmm LTUG cable
A56: Supplying and providing cable end termination of following sizes of XLPE armoured LTUG cable, including labour charges etc all complete and as directed by the departmental officers. a) 3.5 core 95 sqmm LTUG cable
b) 3.5 core 25 sqmm LTUG cable
c) 4 core 16 sqmm LTUG cable
A57: Supply & fixing of Cable gland suitable for following PVC armoured LTUG cable etc., all complete and as directed by the departmental officers. a) 3.5 core 95 sqmm LTUG cable
b) 3.5 core 25 sqmm LTUG cable
c) 4 core 16 sqmm LTUG cable
A58: Supplying and laying of GI pipe "B" class with ISI mark for above ground level including cost of clamping and labour charges, fixing GI pipes etc complete, all complete and as directed by the departmental officers. a) 80mm dia GI pipe "B" class
A59: Supplying and laying of GI pipe "B" class with ISI mark for Below ground level including cost of Eatrh work excavation and refilling ,labour charges, etc complete, all complete and as directed by the departmental officers a) 80 mm dia GI 'B' class pipe
A60: Supplying, laying, fixing and jointing the following ASTM pipes as per IS 4985 suitable UPVC/ GI specials like elbow, tee, reducers, plug, union, bend, coupler, nipple, GM gate valve, check and wheel valve etc a) 50mm dia UPVC pipe (Below G.L)
A61: Supplying and laying of 50mm dia GI pipe (Medium) as per IS 1239/PART I/2004 including cost of pipe and specials etc., all complete and as directed by the departmental officers.
A62: Supply and fixing of 200 A Three phase 500V 4 Pole Change over Switch on suitable angle iron frame work with MS cable entry boxes with PWD earthing.
A63: Supply & fixing of 63 Amps triple pole main switch for incoming control and 2 no of 16 A etc., complete and as directed by the departmental officers
A64: Supply and fixing of 150W LED street light fitting with LED(Lower end) with 40mmdia.GI pipe (class B) with 1no.40mm GI bend complete on the existing post /onwall with PVC unsheathed copper leads with MS clamps and with painting.
A65: supply and erection of 200Amps capacity floor mounting DB panel board (Cubical type) with bus bar chamber Incoming 1 No. 125A FPN on load Changeover switch-EB & DG (FTC HPL) with Manual Closing Mechanism, Short Circuit Rating with Thermal O/L and Magnetic S/C Protection. Bus Bar: 200 Amps 3 phase 4 wire system 25x6mm one run Copper Bus Bar Outgoing 5 Nos. of 63 A 4pole MCB 10KA and 9 Nos of 16A Single pole MCB 10KA Manual Closing Mechanism, Short Circuit Rating with Thermal O/L and Magnetic S/C Protection (for Main panel board) a) Main Panel
A66: Supply and erection of 200Amps capacity 440V 50Hz floor mounting LT panel board (Cubical type) with bus bar chamber provisions 2 Nos.of 5/16 seal bolt with 4mm thick glass with Manual Closing Mechanism, Short Circuit Raling with Thermal O/L and Magnetic S/C Protection Bus Bar: 200 Amps 3 phase 4 wire system 25x6mm one run Copper Bus Bar Outgoing S/C Protection. (for Power panel board) b) Lift Panel
A67: Supply and erection of 200Amps capacity 440V 50Hz floor mounting LT panel board (Cubical type) with bus bar chamber provisions 2 Nos.of 5/16 seal bolt with 4mm thick glass with Manual Closing Mechanism, Short Circuit Raling with Thermal O/L and Magnetic S/C Protection Bus Bar: 200 Amps 3 phase 4 wire system 25x6mm one run Copper Bus Bar Outgoing S/C Protection. (for Power panel board) c) For Genset
A68: Supplying and fixing of CP Wall Mixture Tap 3 in 1 system with Hand Showers including cost of all materials and all labour charges etc., all complete.
A69: Supplying and fixing of SFRC manhole Cover with frame of following size with locking arrangements including of all cost etc., all complete and as directed by the departmental officers. a) 600mm x 600mm
b) 300mm x 300mm
A70: Supply and fixing of 63A Three phase 500V 4 Pole Change over Switch on suitable angle iron frame work with MS cable entry boxes with PWD earthing
A71: Run off mains with 4 wires of 6 Sqmm copper PVC insulated unsheathed single core 1.1KV cable wire contuinuous earth by means of 4 Sqmm copper PVC insulated unsheathed single core 1.1 KV grade cable in fully concealed 19 mm / 20 mm dia rigid PVC conduit pipe heavy duty with ISI mark including cost of all materials, specials, etc., all complete.
A72: Run off mains with 4 wires of 10 Sqmm copper PVC insulated unsheathed single core 1.1KV cable wire contuinuous earth by means of 6 Sqmm copper PVC insulated unsheathed single core 1.1 KV grade cable in fully concealed 19 mm / 20 mm dia rigid PVC conduit pipe heavy duty with ISI mark including cost of all materials, specials, etc., all complete.
A73: Supply and fixing of Single Pole 6A to 32A, 10KA Miniature circuit breakers etc., all complete and as directed by the departmental officers.
A74: 3 Nos.of 100 Amps - Fuse Unit
A75: Supply and fixing of 25A Flush type Wall Socket 25A DP MCB complete set for AC Plug in flush with wall with earth connection (For AC Plug)
A76: Supply and fixing of 24W LED 4000K 2 x 2 Square Type Recessed light Fitting including cost of fixing charges, tools, connetions and etc., complete and as directed by the departmental officers.
A77: supply and fixing of 18W LED Round type Recessed fitting with LED (Lower end) on false Ceiling from ceiling with PVC unsheathed copper leads from terminals to the fitting.
A78: Supply and fixing of 1000W automaticel electric water heater of 25 litres capacity suitable for 230V 50c/s AC supply on suitable MS clamps with 3 core flex wire but without plumbing work etc., complete and as directed by the departmental officers.
A79: Supplying and fixing of 6 way Distribution board including 2 Nos of 16 amps MCB, 2 Nos 10 amps and 5 Nos 6 amps 40 amps ELCB four pole, rotary switch - 3 Nos, Indicator - 3 Nos, including all materials and labour charges etc, arth connection etc., all complete and as directed by the departmental officers.
A80: Supply and fixing of 6 way Horizontal Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 No. 63A 4P MCB switch as incoming and 18 Nos. of 6A to 32A SP MCB as outgoing on wall with earth connection only. (Lower End)
CCTV Camera arrangements: A81: S & F of HIKVISION DS-2CD33412GE- LIU 2.8MM 4MP IP CAMERA DOME Image Sensor 1/3" progressive scan CMOS Min. Illumination Color: 0.01 Lux @ (F1.2, AGC ON), 0.028Lux @ (F2.0, AGC ON) Shutter Speed 1/3 s to 1/100, 000 s Slow Shutter Yes, MIC Auto-Iris No Day & Night IR cut filter Digital Noise Reduction 3D DNR WDR 120 dB Angle Adjustment Pan: 0° to 360°, tilt: 0° to 75°, rotation: 0° to 360°
A82: S & F of HIKVISION DS-2CD 3041G2E-LIU 4MM 4MP IP CAMERA DOME Image Sensor 1/3" progressive scan CMOS Min. Illumination Color: 0.01 Lux @(F1.2, AGC ON), 0.028Lux @ (F2.0, AGC ON) Shutter Speed 1/3 s to 1/100, 000 s Slow Shutter Yes,MIC Auto-Iris No Day &Night IR cut filter Digital Noise Reduction 3D DNR WDR 120 dB Angle Adjustment Pan: 0° to 360°, tilt: 0° to 75°, rotation: 0° to 360°
A83: S & F of WD PURPLE 10TB 3.5 HDD SURVEILLANCE 7200RPM 256MB SATA3 WESTERN DIGITAL WD Purple Pro WD101PURP 10 TB Hard Drive - 3.5" Internal - SATA (SATA/600) - Server, Video Surveillance System, Storage System, Video Recorder Device Supported - 7200rpm - 550 TB TBW
A84: S & F of HIKVISION 64 CH NVR DS-9664NI-M8/R64-ch 2U 8K NVR Up to 16 channel IP cameras can be connected Up to 12 MP high-definition live view, storage and playback Up to 256 Mbps (or 200 Mbps when RAID is enabled) high incoming bandwidth ensures IP cameras can be connected 2 HDMI (different source) and 2 VGA (different source) interfaces 8 HDD can be used for continuous video recording Supports RAID 0, 1, 5, 6, 10 and N+1 hot spare for even more reliable data storage, effectively avoids data loss risks Up to 8-ch IP speakers can be connected
A85: S & F of 8PORT POE SWITCH CP PLUS WITH 2 UPLINK 8, 100Mbps, RJ45 ports, IEEE802.3u, IEEE802.3ab, IEEE802.3 af • Communication standard IEEE802.3 10Base-T, IEEE802.3u 100Base-TX, IEEE802.3ab 100Base-T • Surge protection 6KV commo mode, 4KV differential mode • PoE Power 96W • Easy and safe installation
A86: S & F of 4PORT POE SWITCH CP PLUS WITH 2 UPLINK 4, 100Mbps, RJ45 ports, IEEE802.3u, IEEE802.3ab, IEEE802.3 af • Communication standard IEEE802.3 10Base-T, IEEE802.3u 100Base-TX, IEEE802.3ab 100Base-T • Surge protection 6KV commo mode, 4KV differential mode • PoE Power 96W • Easy and safe installation
A87: Supplying and fixing of 2U RACK FOR POE SWITCH MOUNTING etc complete.
A88: Supplying and fixing of RACK MOUNT POWER SPIKE WITH 5 SOCKETS etc complete.
A89: Supplying and fixing Acer 139 cm (55 inches) Advanced I Series 4K Ultra HD Smart LED Google TV AR55GR2851UDFL (Black) Resolution: 4K Ultra HD (3840x2160) | Refresh Rate: 60 Hertz | 178 Degree wide viewing angle
A90: Supplying and fixing of ADJUSTABLE WALL MOUNTING KIT FOR TV etc complete.
A91: Supplying and fixing of CAMERA EXTENSION ROD ADJUSTABLE FROM CEILING 30 CM TO 60 CM etc complete.
A92: Supplying and fixing of IP65 CAMERA PVC BOX FOR OUT DOOR POE JUNICTION ENCLOUSER etc complete.
A93: Supplying and fixing of CAMERA POE JUNCTION BOX INDOOR etc complete.
A94: Supplying and fixing of CAT6E 4PAIR CABLE HONEYWELL /CP PLUS 1MTRS
A95: Supplying ans fixing of 2 CORE POWER CABLE ORBIT 1SQMM 1MTRS etc complete.
A96: Charges for INSTALLATION OF CAMERA
A97: Charges for INSTALLATION & CONFIGURATION OF NVR 64CH
A98: CAT6E CABLE LAYING CHARGES IN THE PROVIDED EXISTING PVC PIPE
A99: TP-Link AC1750 Wireless Dual Band Gigabit Ceiling Mount Access Point, EAP245Fast Dual-Band Wi-Fi: Simultaneous 450 Mbps on 2.4 GHz and 1300 Mbps on 5 GHz totals 1750 Mbps Wi-Fi speeds.Integrated into Airtime Fairness and Beamforming technologie
A100: CAT6E CABLE HONEYWELL/ CP PLUS IN MTRS
A101: S & F of 2U RACK
A102: S & F of SPIKEBUSTER WITH 3POWER SOCKET
A103: S & F of 4U RACK
A104: S & F of RACK MOUNT SPIKE
A105: CAT6E CABLE LAYING CHARGES
A106: INSTALLATION & CONFIGURATION OF WIFI AP DEVICES
A107: TP-Link JetStream 8 Port Gigabit L2 Plus Managed Switch with 2 SFP Slots, TL-SG3210
A108: Supply and Installation of Basic caller ID LAN Line Phone, Key Pad, Ringer Volume Control, Tone / Pulse Switchable, Redial, Flash, Pause, Mute etc., for Warden Room (BEETEL /equivalent) etc. all complete as per relevant standard specifications and as directed by the departmental officers.
FIRE SAFETY & PA SYSTEM A109: Supply, installation, testing and commissioning of Micro Processor based conventional 8 Zone Fire Alar Control Panel having the rating of 24 volt DC power supply, LCD display, consisting 230 / 24 volt SMPS unit, 2 Nos. of 12 volt 7 AH standby batteries, suitably mounted on wall using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the Departmental Officers
A110: Supply, installation, testing and commissioning of Electronic Hooter / Sounder, 24V, providing on Ceiling/Flush wall mount using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the Departmental Officers.
A111: Supply, installation, testing and commissioning of Manual Call Point (MCP) providing on wall using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the Departmental Officers.
A112: Supply and laying of FRLS PVC insulated 2 core 1.5 sq.mm. Armoured Copper Cable on ceiling / wall using fixing accessories like screws, plug, clamps, etc., as per standard methods and as directed by the Departmental Officers.
A113: Supplying, installing, testing and commissioning of approved make FRLS PVC conduits on ceiling / wall / floor etc. complete with accessories like, Junction boxes, Collars, Bends, clamps, saddles etc. (for MCP) 25mm dia
A114: GI Hot Dip / Powder Coated 16 SWG Cable Tray with 300mm width and 50mm height (Cable dressing inside the shaft )
PUBLIC ADDRESS SYSTEM A115: Supply, installation, testing and commissioning of 6 W Wall Mounted box Speakers with line matching transformers as specified as per specifications
A117: Supply, installation, testing and commissioning of Rack Mounted 240 W Power Amplifier
A118: Supply and laying of FRLS PVC insulated 2 core 1.5 sq.mm. Armoured Copper Cable on ceiling / wall using fixing accessories like screws, plug, clamps, etc., as per standard methods and as directed by the Departmental Officers.
A119: Supply, installation, testing and commissioning of Volume controller for one speaker (near call station)
A120: S & F of Rack Mounted DVD Player as per specifications
A121: Supply, installation, testing and commissioning OF Suitable size rack as per following specification, Conforms to DIN 41494 Or Equivalent EIA/ ISO/ EN/CEA Standard Finish - Powder coated finish with Seven tank pretreatment process meeting ASTM standard Color - Black/off white/grey Fan module on top of the rack Welded frame with vented top cover with fan, perforated Metal Door with lock & Key and Back vented / Perforated metal door with lock & key and partially vented side panels, free standing on floor with 4 No. casters wheels with 2 no with brakes & 2 No. without brakes, cable oraginesers, Levelers with required 16A/5A power strips including accessories. Number of racks shall be as per the design requirement. vendor to consider required number of racks as per their requirement
FIRE SIGNAGE SYSTEM A122: S & F of " FIRE EXIT " (AUTO GLOW TYPE) - SINGLE SIDE - FOR FIRE EXIT DOORS - 150*300mm with suspension chains (SS)
A123: S & F of " Emergency Exit Signages - (Autoglow) size 150 x 300mm - double side with suspension chains (SS)
A124: S & F of " EXTINGUISHER Signages - Autoglow, with suspension chains (Autoglo signages, size 150 x 300) - double side with suspension chains (SS)
A125: S & F of " MCP Signages - Autoglow, with suspension chains (Autoglo signages, size 150 x 300 - double side with suspension chains (SS)
A126: S & F of " Hydrant - Autoglow, with suspension chains (Autoglo signages, size 150 x 300 - double side with suspension chains (SS)
A127: Fire Evacuation Route Map as per following specification Preparation of drawing and providing, Autoglow Fire escape route map in clear acrylic glass and required glass studs supports etc. Indicating direction, Key plan, contact numbers etc. (The sample of the same need to be presented for approval before execution)…. (Maximum size of the board A3) Evacuation plan shall be glow in dark A3 size with 5mm thick rear & 3mm thick front acrylic cover including wall mount supports.
FIRE EXTINGUISHER SYSTEM A128: Supply and fixing of Carbon-di-Oxide Gas Type 2 kg. capacity Fire Extinguisher as per New IS15683, complete with control valve, discharge hose with horn, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition herever found neccessary etc., complete as per standard specification and as directed by the Departmental Officers.
A129: Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental Officers.
A130: Wet chemical stored pressure 6Ltr capacity including accessories, pressure guage and floor mounting accessories (kitchen - preparation area)
A131: Supply, erection, testing and commissioning of following MS ‘C’ Class Heavy Duty Pipe as per IS 1239 to withstand a developing pressure of 10 kg. / sq.cm including necessary fittings like MS flange of table ‘E’, elbows, reducers, gaskets, bolt, nuts with washers & joints as per standard method of arc welding, including one coat metal primer and two coat Post Office Red painting including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers a) 150mm dia
b) 100mm dia
c) 80mm dia
d) 25mm dia
A132: Supply, erection, testing and commissioning of fire fighting application monoblock motor pumpset of 900 LPM at 40 metres head to develop 3.5 kg/sq.cm at the heightest and farthest hydrant point to make 30 m water jet at the time of fire fighting emergency cicumstances, coupled with 11 KW / 15 HP rated three phase 414 volts, 50 Hz, 2880 rpm electrical motor the pump with cast ron body, bronze impeller, rope gland packaging, suction size of 80 mm dia. delivery size of 65 mm dia., including the cost of foundaton concrete anti vibration mounting, rain safety hood and etc.complete as directed by the Departmental Officers (Kirloskar make KDS 1555+ or Equivalent)
A134: Supply and laying of 4 core 10 sq.mm. armoured copper cable for power wiring to the Terrace Pump Motor with runs of 14 SWG TC wire for earthing, providing in wall with suitable size GI clamps, screws,wooden plug, end termination by using suitable size cable glands, copper sockets and etc., as directed by the Departmental Officers.
A135: Supply, erection, testing and commissioning of Pressure Gauge with 0 to 14 kg. range of reputed make with necessary valve, milling thread MS coupling fixed at delivery pipe line in pump house to read the developing pressure including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers.
A136: Supply, erection, testing and commissioning of suitable Pressure Switch of reputed make line Indfoss or Donfoss including necessary valves, couplings, etc., connected with electrical main control panel and setup at proper differential so as to auto start and auto stop the electrical motor, jockey motor including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., completed as per standard specification and as directed by the Departmental Officers.
A137: Supply, erection, testing and commissioning of cast iron body and bronze internal non-rising spindle sluice valve of sizes at required places to control the flow of water including necessary MS flange of table ‘E’, gaskets, bolts & nuts including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. a) 150 NB
A138: Supply, erection, testing and commissioning of Cast iron body and Gun metal or stainless steel internal Non-return valve of following sizes to control one way flow of water to be installed pump room at delivery line and near overhead tank at terrace level near to jockey pump and motor including necessary MS flange of table ‘E’, gaskets, bolts & nuts, etc. as per IS 5312 including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. 150 NB
A139: Supply and fixing of Fire fighting application oblique type stainless steel Hydrant Valve of size 63mm dia with oblique type instantaneous coupling with rotating wheel to open and close the valve including MS flange of table “E”, bolts & nuts with washer as per IS 5290 at ring main around the building and wet riser inside the building including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc complete as per standard specification and as directed by the Departmental Officers.
A140: Supply, and fixing in position of Fire Fighting Application Hose of 63mm dia of 15 metres length binded by copper wire with 63mm dia stainless steel male and female instantaneous fire fighting special coupling as per IS 901 as directed by the Departmental Officers. Near every hydrant points including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc complete as per standard specification and as directed by the Departmental Officers.
A141: Supply, and fixing in position of Fire Fighting Application 63mm dia stainless steel short length Branch Pipe with hexagonal type spray nozzle of 15mm (or) 20mm jet bore. Near every hydrant points including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers.
A142: Supply of Fire Fighting Application MS Hose Box to keep two number of hoses and 1 No. of branch pipe with nozzle having proper glass window type double door with universe open key, painted inside white and outside Post Office Red. Near every hydrant point including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers
A143: Supply, erection, testing and commissioning of Air Release Valve of 20mm dia, so as to release airlock in 100mm dia MS pipe at top most wet riser, including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers
A144: Supply, installation of Fire Fighting Application 180 degree swinging type, hose reel drum with 20mm dia braided thermoplastic hose of 30 metres long, so as to extend to necessary distance by self rolling spindle wheel including necessary 20mm dia ball valve and open and close spray nozzle, warm clip, etc., as per the standard pattern of any reputed make at every floor nearer to hydrant valve, including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary., etc., complete as per standard specification and as directed by the Departmental Officers.
A145: Supply and fixing in position of Fire Fighting Duct Window having proper glass window type double door with universe open key, painted inside white and outsid post office red for the sizes of 1300 x 900 x 500mm (L x B x D) fabricated using 25 x 3mm MS 'L' Angle and all sides covered with 2mm thick MS sheets, suitable arrangements to kept 2 Nos. of Fire Fighting Hoses and 1 No. Branch Pipe, mounted in fire duct using anchor fasteners, etc., as per standard specifications and as per directed by the Departmental Officers.
A146: Supply, erection, testing and commissioning of Fire Fighting 2 Way Fire Brigade Inlet with necessary gun metal 63mm dia non-return spring shutter arrangements so that to control one way flow at the time of emergency water supply by fire and rescue service fire engine entry including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary., etc., complete as per standard specification and as directed by the Departmental Officers.
A147: Supply and fixing of MS Angle Supports with related accessories etc. (37.5 x 37.5 x 6.24mm) etc., complete and as directed by the Departmental Officers.
A148: Supplying and installation of Y type Strainer as per specifications including making flanged joints by providing with necessary flanges, nut, bolts & washers, painting, etc. complete as required . 150 NB
A149: Supplying, installing, testing and commissioning of Gun metal chrome finished 25mm dia Ball valves with fittings of screwed end type.
A150: Supply and fixing of CP 2 way bib cock Health Faucet approved quality with ISI mark including cost of all materials and labour charges etc. all complete and as directed by the departmental officers.
chendur construction company (BID ID -1275999)
LGN CONSTRUCTION (BID ID -1275996)
ASR CONSTRUCTIONS (BID ID -1265900)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_632126.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .