Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.6 CrAccepted-AOC AT JASOIYA P O AURANGABAD P S AURANGABAD BIHAR | ₹2.6 Cr | L1 | Accepted-AOC CE South Bihar Letter No. 2950 Dt. 07.11.2022 |
| 2 | L2₹2.7 Cr+₹8.1 L (3.06%)Rejected-Finance | ₹2.7 Cr+₹8.1 L (3.06%) | L2 | Rejected-Finance CE, South, RCD Letter No. 2950, Dt. 07.11.2022 |
Tender Value
₹3.0 Cr
EMD Value
₹6.1 L
Closing Date
2 Jul 2022, 3:00 pmClosed
EXECUTIVE ENGINEER, RCD, ROAD DIV NO.1, AURANGABAD
O/O EXECUTIVE ENGINEER, RCD, ROAD DIVISION NO. 1, AURANGABAD
Construction of High Level RCC Bridge 2 x 16.50m at 3.65 km of Bishrampur to Murgadha to Narayanpur Road for the year 2022-23, Package No. BR02RC-324, Length of Bridge-36.00 M
2022_RCD_119064_12
RCD/AUR/RCPLWEA/01/22-23
Open Tender
Civil Works - Bridge Construction
Item Rate
270 days
AURANGABAD
Please refer tender documents
4 documents required · 4 mandatory
₹10,000
₹6.1 L
PATNA
22 Feb 2023
27 Jun 2022
6 Jul 2022
27 Jun 2022
2 Jul 2022
27 Jun 2022
27 Jun 2022
Amount
FOUNDATION Excavation for Structures : Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary Soil Upto 3m depth
Providing and laying of PCC M15 levelling course 100mm thick below the pile cap. PCC Grade M-15 (Levelling Course for Pile Cap)
R.C.C. grade M 30 in Pile Foundation complete as per Dwg & Tech Specification. Pile Cap in RCC M-30
Bored cast in situ M-35 grade RCC Pile excluding Reinforcement complete as per Drawing and Technical Specifications and removal of excavated earth with al lifts and lead upto 1000 m. 1200 mm Dia
Supplying, fitting and placing HYSD bar reinforcement in foundation complete as per drawings and technical specifications Clauses 1000 and 1202
Providing steel liner 10 mm thick for curbs and 6mm thick for steining of wells including fabricating and setting out as per detailed drawing
Providing and Constructing Temporary Earth Island (Assuming depth of water 1.0 m and height of island to be 1.25 m including Royality for earth @ Rs. 8289.60.00 for each Island.)
Providing and Constructing one span service road to reach island location from one pier location to antother pier location including Royalty from earth @ 495.00/m
SUBSTRUCTURE : R.C.C. grade M-30 in Substructure complete as per Dwg & Tech Specification, RCC M-30 i) Upto 5m height (Using Concrete Mixer)
R.C.C. grade M-30 in Substructure complete as per Dwg & Tech Specification, RCC M-30 ii) From 5m upto 10m height (Using Concrete Mixer)
R.C.C. grade M-35 in Substructure complete as per Dwg & Tech Specification, RCC M-35 ii) From 5m upto 10m height (Using Concrete Mixer)
Supplying, fitting and placing HYSD bar reinforcement (Fe 500) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Supplying, fitting and fixing in position true to line and level POT-PTFE bearing consisting of a metal piston supported by a disc or unreinforced elastomer confined within a metal cylinder, sealing rings, dust seals, PTFE surface sliding against stainless steel mating surface, completre assembly to be of cast steel/fabricated structural steel, metal and elastomer elements to be as per IRC: 83 part-I & II respectively and other parts conforming to BS: 5400, section 9.1 & 9.2 and clause 2006 of MoRTH Specifications complete asper drawing and approved technical specifications.
Supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to IRC: 83 (Part-II) section IX and clause 2005 of MoRTH specifications complete including all accessories as per drawing and Technical Specifications.
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 I) Sandy Material
Providing and laying filter media with granular crushed aggregates (Jhama Metal) as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8
SUPERSTRUCTURE : Providing and laying reinforced cement concrete in superstructure complete as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 II. RCC M-30 (Height 5m to 10m)
Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3
Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and technical specifications Clauses 800, 900 and 1208.3
Drainage Spouts complete as per drawing and technical specifications Clause 1209
P.C.C. M-15 ordinary grade (1:2.5:5) levelling course below approach slab complete as per drawing and technical specificatios Clauses 800 & 1211.
Reinforced Cement Concrete M-30 grade approach slab including reinforcement and formwork complete as per drawing and technical specifications Clauses 800 and 1211
Strip Seal Expansion Joint (Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instructions for installation.)
Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification.
PROTECTION WORK : Providing and laying boulder pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302
Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications Clause 1302
Providing and fixing of road stud 100 x 100 mm die cast in aluminium, resistant to corrosive effect of salt and grit, fitted with lense reflectors, installed in concrete or asphaltic surface by drilling holes 30 mm upto a depth of 600 mm and bedded in a suitable bituminous grout or epoxy mortar, all as per BS:873 (Part 4) 1973.
Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
Providing and erecting a "W" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground leve, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS: 1367 and IS: 1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810
Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade
Diversion Works : Laying Reinforced cement concrete pipe NP4/prestressed concrete pipe for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets. (1000mm Dia)
Earth work in road embankment with ordinary soil ( vide classification of soil item - A)obtained from borrow pits ( Maxm. 1 km. lead ) all complete job as per Technical Specification of MoSRTH.
Construction of granular sub-base by providing well graded material, spreading in uniform layers with tractor mounted grader arrangement on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401 Grading-I
Routine Maintenance amount for 1st year
Routine Maintenance amount for 2nd year
Routine Maintenance amount for 3rd year
Routine Maintenance amount for 4th year
Routine Maintenance amount for 5th year
12% GST Amount (Construction and Maintenance)
KALYANI CONSTRUCTION
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .