| 1 | L1₹33.4 LAccepted-AOC 131 SANGAM NAGAR OPP NATIONAL SCHOOL SANGHVI PUNE 411027 | PUNE | MAHARASHTRA | 411027 | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹37.6 L+₹2.9 L (8.29%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest tenderer | |
| 3 | L3₹40.9 L+₹6.2 L (17.7%)Rejected-Finance N NO 6 OLD NO 10 1ST STREET KASTHURI BAI NAGAR AVADI CHENNAI 600054 | CHENNAI | CHENNAI | TAMIL NADU | 600054 | L3 | Rejected-Finance Being other than lowest tenderer | |
| 4 | L4₹43.9 L+₹9.1 L (26.2%)Rejected-Finance 27 1ST STREET PERIYAR NAGAR 1ST STREET PERIYAR NAGAR ADAMBAKKAM KANCHIPURAM TAMIL NADU 600088 | CHENNAI | TAMIL NADU | 600088 | L4 | Rejected-Finance Being other than lowest tenderer | |
| 5 | L5₹49.4 L+₹14.6 L (42.0%)Rejected-Finance | L5 | Rejected-Finance Being other than lowest tenderer |
Tender Value
₹37.7 L
EMD Value
₹76,000
Closing Date
30 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri. Narinder Singh, IDSE, SE(SAG)
COMMANDER WORKS ENGINEERS CHENNAI PALLAVAN SALAI CHENNAI 600 002
86520E8 SPL REP TO EXT ELECT AND ALLIED WKS AT PO COLONY AND SURROUNDING UNDER GE STM CHENNAI
2022_MES_527837_1
86520E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
STM CHENNAI
AS PER NIT
9 documents required · 9 mandatory
₹500
GE STM CHENNAI
₹76,000
Yes
20 Aug 2022
1 Jun 2022
7 Jul 2022
1 Jun 2022
30 Jun 2022
18 Jun 2022
1 Jun 2022 - 8 Jun 2022
60 days
Amount
REVISED BOQ UPLOADED ON 14 JUN 2022, BOQ UPLOADED ON 31 MAY 2022 CANCELLED
SCH "A" PART-I (ELECTRIFICATION)
Earthwork in excavation by mechanical means (hydraulic excavator) in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50m in any type of soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and exceeding 1.5m but not exceeding 3.0m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified and as directed.
Earthwork is deemed to be carried out by manual method. However mechanised method may be adopted without any extra cost to the government.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm in any type of soil complete all as specified and as directed.
Steel tubing, galvanised, light grade, with all fittings such as bends, elbows, tees etc., and laid in trenches / under floor / under roads / crossings etc., of following bore of pipe for cable protection complete all as specified and as directed.
Earthwork as required shall be measured and paid separately.
(a) Bore of pipe 40mm
(b) Bore of pipe 50mm
(c) Bore of pipe 80mm
Steel tubing, galvanised, medium grade, with all fittings such as bends, elbows, tees etc., and laid in trenches / under floor / under roads / crossings etc., of bore of pipe 80mm for cable protection complete all as specified and as directed.
Earthwork as required shall be measured and paid separately.
Steel tubing, galvanised, light grade, with all fittings such as bends, elbows, tees etc., and fixed complete to walls and ceilings or laid in floors etc., of bore of pipe 40mm complete all as specified and as directed.
Fine sieved excavated dry soil laid to required width of trench at bottom and top for cable cushioning all as specified and as directed.
(a) Punned thickness only shall be measured.
(b) The soil used shall be free from sharp grains and deletrious materials like dry / decayed plants etc.,
Common burnt bricks sub class "B" of old size, designation 50, laid dry in trenches with width equal to length of bricks across the cable for cable protection all as specified and as directed.
Taking out existing LT cables of assorted sizes and taken on credit and provision of XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 650/1100 volts grade, in trenches / drawn through pipe / fixed on walls / bare in road crossings / paths / drains / ducts / floors / fixed on poles / equipments of the following sizes complete all as specified and as directed.
(a) Earthwork, cushioning, protection for cable etc., as required shall be measured and paid separately.
(b) Lugs and glands shall be used appropriately wherever required while connecting cables to the panel board and the quoted rates are deemed be include for the same.
(i) 4 core, cross sectional area 10 sqmm
(ii) 4 core, cross sectional area 16 sqmm
(iii) 4 core, cross sectional area 25 sqmm
(iv) 3.5 core, cross sectional area 35 sqmm
(v) 3.5 core, cross sectional area 50 sqmm
(vi) 3.5 core, cross sectional area 70 sqmm
(vii) 3.5 core, cross sectional area 95 sqmm
(viii) 3.5 core, cross sectional area 120 sqmm
Supply, laying, connecting and testing HT UG cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 11000 volts grade,(earthed), 3 core, cross sectional area 95 sqmm in trenches / drawn through pipe / fixed on walls / bare in road crossings / paths / drains / ducts / floors / fixed on poles / equipments including taking out existing cables and taken on credit complete all as specified and as directed.
(a) Lugs and glands shall be used appropriately wherever required while connecting cables to the panel board and the quoted rates are deemed be include for the same.
(b) Earthwork, sand cushioning, protection for cable etc., as required shall be measured and paid separately.
(c) Precommissioning test shall be carried out at factory premises before despatch.
Cable route indicator dully marked with HT or LT cable, working voltage, size of cable and route made out of GI plate 3mm thick, 150mm dia fixed on angle iron ISA 25mm x 25mm x 3mm, 500mm long, suitably embedded in PCC 1:2:4, type B1 using 20mm graded stone aggregate of size 300mm x 300mm x 300mm on ground and the mild steel surfaces shall be painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Cable jointing kit for 11 kV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and as directed.
Cable jointing kit for 11 kV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and as directed.
Precast concrete cable cover un-reinforced. class HV, Type 1, flat, size 300mmx l80mm x 40mm complete all as specified and as directed.
Plain cement concrete 1:4:8, type D2 using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed.
Plain cement concrete, type B1, 1:2:4, using 20mm graded granite stone aggregate as in coping of poles, stay assembly above ground level including weathering, slightly rounded or chamfered angles, including necessary formwork complete all as specified and as directed.
Taking down existing poles including bracket and taken on credit and provision of Steel tubular swaged poles complete with 6mm thick cast iron base plate, finial taper plug, bolts, nuts and screws as specified, type 410, SP-31 (9.00 metres long) and shall be coated with two coats of black bituminous paint throughout internally, and externally up to the planting depth and the remaining, portion of the exterior shall be painted with one coat of red oxide zinc chrome primer complete all as specified and as directed.
Earthwork, PCC foundation, coping etc as required for erection of pole shall be measured and paid separately.
Wiring with PVC insulated and PVC sheathed cable, copper round conductor of size 3 core, 1.5 sqmm, 1100 volts grade, drawn through and including suitable dia rigid PVC conduit, conduit fittings and conduit accessories and fixed with suitable clamps complete all as specified and as directed.
Sheet moulded compound (SMC) box, weather proof type, hinged door, off white colour of size 240mm x 130mm x 110mm comprising MCB SP 6 Amps, 10 kA - 01 No and Neutral link - 01 No fixed on pole with suitable clamps, bolts and nuts duly painted as in repairs complete all as specified and as directed.
Make shall be Sintex Cat No. GSJB-2817 or equivalent of makes as listed here-in-after.
Pole mounting bracket for street light fittings made out of GI pipe medium grade 40mm bore of pipe 2m long bent to shape with suitable mild steel clamps duly painted with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer and fixed on steel tubular pole complete all as specified and as directed.
Taking down existing light fitting and taken on credit and provision of LED street light fittings, with and including lamps, system wattage of 90 Watts, fixture housing with die cast aluminium and individual high power LED as light source and lens embedded PC cover with TOP opening separate driver compartment with IP-66 protection, and impact resistance of IK07 suitably mounting on existing brackets with suitable mild steel clamps duly painted with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer prewired with PVC sheathed 2.5 sqmm 3 core copper conductor flexible wire run through 20mm conduit from SMC box to light fitting and fixed with clamps complete all as specified and as directed.
(a) Make shall be Havells Cat No. ENDURAOMNIPLUSSL90WLED757SASYTOPC or equivalent of makes as listed here-in-after.
(b) For all other mandatory requirements of LED fittings, please refer Particular Specifications here-in-after.
Taking down existing light fitting and taken on credit and provision of LED street light fittings, with and including lamps, system wattage of 120 Watts, fixture housing with die cast aluminium and individual high power LED as light source and lens embedded PC cover with TOP opening separate driver compartment with IP-66 protection, and impact resistance of IK07 suitably mounting on existing brackets with suitable mild steel clamps duly painted with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer prewired with PVC sheathed 2.5 sqmm 3 core copper conductor flexible wire run through 20mm conduit from SMC box to light fitting and fixed with clamps complete all as specified and as directed.
(a) Make shall be Havells Cat No. ENDURAOMNIPLUSSL120WLED757SASYTOPC or equivalent of makes as listed here-in-after.
(b) For all other mandatory requirements of LED fittings, please refer Particular Specifications here-in-after.
Removing of old earthing materials and taken on credit and provision of new earthing complete with galvanised iron earth plate electrode 600mm X 600mm X 6mm thick, with and including earthing of 25mm x 4mm dia GI strip protected by 40mm dia GI pipe light grade upto a length of 7.5m. The plate shall be buried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of the earth plate at a depth not less than 1.5 metres below ground level, connected to earth lead as described here-in-before by means of bolts, nuts, washers and checknuts made out of galvanised iron or mild steel, earthing lead protected by as described here-in-before and connected to main switch board or main control board or electric pole all as shown on electrical plate No.3 of MES Sch Part-I including necessary earth work and excavation in any type of soil, plain cement concrete 1:3:6, type C1 chamber, reinforced cement concrete cover slab with locking arrangement and handle of 10mm dia MS round bars 450mm long, 1:2:4 type B1, 50mm thick with 8mm dia TMT bars at 140mm centre to centre both ways, GI pipe of bore 20mm medium grade for watering with funnel, wiremesh, salt, charcoal, lugs including testing complete all as specified and as directed.
Design, fabrication, supply, installation, testing and commissioning of LT feeder pillar panel board, outdoor type, made up of CRCA sheet minimum 3mm thick and pressed steel framework, top with sloping canopy, bottom with detachable plates, to accommodate the accessories as detailed below with hinged doors, front and back side openable with locking arrangement, weather, dust and vermin proof, epoxy powder coated, to minimum IP-54 protection class of IS-2147, pedestal mounted, LT 415 volts, 3 Phase, 4 wire, 50 cycles, including cable galleries, interconnecting bus-bar connection / linkage, suitable for housing and including provision of the following switch gears including all pre-wiring with PVC copper conductor cable of suitable size, nuts, bolts and washers and cable connection with suitable size aluminium lugs and glands in accordance with IS-13947 (Part-I) 1993 & IS-8623 including dismantling existing LT feeder pillar board including components all as specified and directed by Engineer-in-Charge.
(a) Aluminium bus bar with 400 Amps rating for 3 phase and neutral with heat shrinkable PVC coloured sleeves and aluminium earth bus of suitable size mounted on suitable insulators with terminal switch - 01 Set
(b) MCCB 250 Amps, 4 pole, 415 Volts, 50 Hz, 35 kA with adjustable thermal and adjustable magnetic setting with protection for overload and short circuit and conforming to IEC60947 / IS 13947 (Pt-II) 1993 (Latest version) and with Ics = 100% of Icu - 01 No.(incoming)
(c) MCCB 100 Amps, 4 pole, 415 Volts, 50 Hz, 16 kA with fixed thermal and fixed magnetic setting with protection for overload and short circuit and conforming to IEC60947 / IS 13947 (Pt-II) 1993 (Latest version) and with Ics = 75% of Icu - 04 Nos.(incoming)
(d) Multifunction meter digital type with CTs - 01 No
(e) LED type pilot indicator lamps RYB phases with backup fuse, Set of three - 01 No.
(f) The LT panel board shall be of kept on platform 450mm above ground level, mounted on base framework of angle iron 50mm x 50mm x 6mm planted into platform of PCC 1:2:4, type B1, using 20mm graded stone aggregate, over PCC foundation of 100mm thickness in PCC 1:4:8, type D2 using 40mm graded stone aggregate, the exposed concrete surfaces shall be rendered in CM 1:4, 10mm thick, finished fair and even and applied white wash three coats.
Design, fabrication, supply, installation, testing and commissioning of LT feeder pillar panel board, outdoor type, made up of CRCA sheet minimum 3mm thick and pressed steel framework, top with sloping canopy, bottom with detachable plates, to accommodate the accessories as detailed below with hinged doors, front and back side openable with locking arrangement, weather, dust and vermin proof, epoxy powder coated, to minimum IP-54 protection class of IS-2147, pedestal mounted, LT 415 volts, 3 Phase, 4 wire, 50 cycles, including cable galleries, interconnecting bus-bar connection / linkage, suitable for housing and including provision of the following switch gears including all pre-wiring with PVC copper conductor cable of suitable size, nuts, bolts and washers and cable connection with suitable size aluminium lugs and glands in accordance with IS-13947 (Part-I) 1993 & IS-8623 including dismantling existing LT feeder pillar board including components all as specified and directed by Engineer-in-Charge.
(a) Aluminium bus bar with 400 Amps rating for 3 phase and neutral with heat shrinkable PVC coloured sleeves and aluminium earth bus of suitable size mounted on suitable insulators with terminal switch - 01 Set
(b) MCCB 250 Amps, 4 pole, 415 Volts, 50 Hz, 35 kA with adjustable thermal and adjustable magnetic setting with protection for overload and short circuit and conforming to IEC60947 / IS 13947 (Pt-II) 1993 (Latest version) and with Ics = 100% of Icu - 01 No.(incoming)
(c) MCCB 100 Amps, 4 pole, 415 Volts, 50 Hz, 16 kA with fixed thermal and fixed magnetic setting with protection for overload and short circuit and conforming to IEC60947 / IS 13947 (Pt-II) 1993 (Latest version) and with Ics = 75% of Icu - 04 Nos.(incoming)
(d) Three phase contactor with digital timer for security light of capacity 63 Amps - 01Nos.
(e) Multifunction meter digital type with CTs - 01 No
(f) LED type pilot indicator lamps RYB phases with backup fuse, Set of three - 01 No.
(g) The LT panel board shall be of kept on platform 450mm above ground level, mounted on base framework of angle iron 50mm x 50mm x 6mm planted into platform of PCC 1:2:4, type B1, using 20mm graded stone aggregate, over PCC foundation of 100mm thickness in PCC 1:4:8, type D2 using 40mm graded stone aggregate, the exposed concrete surfaces shall be rendered in CM 1:4, 10mm thick, finished fair and even and applied white wash three coats.
Design, fabrication, supply, installation, testing and commissioning of LT feeder pillar panel board, outdoor type, made up of CRCA sheet minimum 3mm thick and pressed steel framework, top with sloping canopy, bottom with detachable plates, to accommodate the accessories as detailed below with hinged doors, front and back side openable with locking arrangement, weather, dust and vermin proof, epoxy powder coated, to minimum IP-54 protection class of IS-2147, pedestal mounted, LT 415 volts, 3 Phase, 4 wire, 50 cycles, including cable galleries, interconnecting bus-bar connection / linkage, suitable for housing and including provision of the following switch gears including all pre-wiring with PVC copper conductor cable of suitable size, nuts, bolts and washers and cable connection with suitable size aluminium lugs and glands in accordance with IS-13947 (Part-I) 1993 & IS-8623 including dismantling existing LT feeder pillar board including components all as specified and directed by Engineer-in-Charge.
(a) Aluminium bus bar with 300 Amps rating for 3 phase and neutral with heat shrinkable PVC coloured sleeves and aluminium earth bus of suitable size mounted on suitable insulators with terminal switch - 01 Set
(b) MCCB 200 Amps, 4 pole, 415 Volts, 50 Hz, 35 kA with adjustable thermal and adjustable magnetic setting with protection for overload and short circuit and conforming to IEC60947 / IS 13947 (Pt-II) 1993 (Latest version) and with Ics = 100% of Icu in panel mounted enclosures - 01 No.(incoming)
(c) MCCB 100 Amps, 4 pole, 415 Volts, 50 Hz, 16 kA with fixed thermal and fixed magnetic setting with protection for overload and short circuit and conforming to IEC60947 / IS 13947 (Pt-II) 1993 (Latest version) and with Ics = 75% of Icu in panel mounted enclosures - 04 Nos.(incoming)
(d) Three phase contactor with digital timer for security light of capacity 63 Amps - 01Nos.
(e) Multifunction meter digital type with CTs - 01 No
(f) LED type pilot indicator lamps RYB phases with backup fuse, Set of three - 01 No.
(g) The LT panel board shall be of kept on platform 450mm above ground level, mounted on base framework of angle iron 50mm x 50mm x 6mm planted into platform of PCC 1:2:4, type B1, using 20mm graded stone aggregate, over PCC foundation of 100mm thickness in PCC 1:4:8, type D2 using 40mm graded stone aggregate, the exposed concrete surfaces shall be rendered in CM 1:4, 10mm thick, finished fair and even and applied white wash three coats.
Design, fabrication, supply, installation, testing and commissioning of LT feeder pillar panel board, outdoor type, made up of CRCA sheet minimum 3mm thick and pressed steel framework, top with sloping canopy, bottom with detachable plates, to accommodate the accessories as detailed below with hinged doors, front and back side openable with locking arrangement, weather, dust and vermin proof, epoxy powder coated, to minimum IP-54 protection class of IS-2147, pedestal mounted, LT 415 volts, 3 Phase, 4 wire, 50 cycles, including cable galleries, interconnecting bus-bar connection / linkage, suitable for housing and including provision of the following switch gears including all pre-wiring with PVC copper conductor cable of suitable size, nuts, bolts and washers and cable connection with suitable size aluminium lugs and glands in accordance with IS-13947 (Part-I) 1993 & IS-8623 including dismantling existing LT feeder pillar board including components all as specified and directed by Engineer-in-Charge.
(a) Aluminium bus bar with 500 Amps rating for 3 phase and neutral with heat shrinkable PVC coloured sleeves and aluminium earth bus of suitable size mounted on suitable insulators with terminal switch - 01 Set
(b) MCCB 320 Amps, 4 pole, 415 Volts, 50 Hz, 35 kA with adjustable thermal and adjustable magnetic setting with protection for overload and short circuit and conforming to IEC60947 / IS 13947 (Pt-II) 1993 (Latest version) and with Ics = 100% of Icu - 01 No.(incoming)
(c) MCCB 200 Amps, 4 pole, 415 Volts, 50 Hz, 16 kA with adjustable thermal and adjustable magnetic setting with protection for overload and short circuit and conforming to IEC60947 / IS 13947 (Pt-II) 1993 (Latest version) and with Ics = 100% of Icu in panel mounted enclosures - 03 Nos.(incoming)
(d) MCCB 100 Amps, 4 pole, 415 Volts, 50 Hz, 16 kA with fixed thermal and fixed magnetic setting with protection for overload and short circuit and conforming to IEC60947 / IS 13947 (Pt-II) 1993 (Latest version) and with Ics = 75% of Icu in panel mounted enclosures - 01 No.(incoming)
(e) Multifunction meter digital type with CTs - 01 No
(f) LED type pilot indicator lamps RYB phases with backup fuse, Set of three - 01 No.
(g) The LT panel board shall be of kept on platform 450mm above ground level, mounted on base framework of angle iron 50mm x 50mm x 6mm planted into platform of PCC 1:2:4, type B1, using 20mm graded stone aggregate, over PCC foundation of 100mm thickness in PCC 1:4:8, type D2 using 40mm graded stone aggregate, the exposed concrete surfaces shall be rendered in CM 1:4, 10mm thick, finished fair and even and applied white wash three coats.
Design, fabrication, supply, installation, testing and commissioning of LT feeder pillar panel board, outdoor type, made up of CRCA sheet minimum 3mm thick and pressed steel framework, top with sloping canopy, bottom with detachable plates, to accommodate the accessories as detailed below with hinged doors, front and back side openable with locking arrangement, weather, dust and vermin proof, epoxy powder coated, to minimum IP-54 protection class of IS-2147, pedestal mounted, LT 415 volts, 3 Phase, 4 wire, 50 cycles, including cable galleries, interconnecting bus-bar connection / linkage, suitable for housing and including provision of the following switch gears including all pre-wiring with PVC copper conductor cable of suitable size, nuts, bolts and washers and cable connection with suitable size aluminium lugs and glands in accordance with IS-13947 (Part-I) 1993 & IS-8623 including dismantling existing LT feeder pillar board including components all as specified and directed by Engineer-in-Charge.
(a) Aluminium bus bar with 400 Amps rating for 3 phase and neutral with heat shrinkable PVC coloured sleeves and aluminium earth bus of suitable size mounted on suitable insulators with terminal switch - 01 Set
(b) MCCB 250 Amps, 4 pole, 415 Volts, 50 Hz, 35 kA with adjustable thermal and adjustable magnetic setting with protection for overload and short circuit and conforming to IEC60947 / IS 13947 (Pt-II) 1993 (Latest version) and with Ics = 100% of Icu - 01 No.(incoming)
(c) MCCB 100 Amps, 4 pole, 415 Volts, 50 Hz, 16 kA with fixed thermal and fixed magnetic setting with protection for overload and short circuit and conforming to IEC60947 / IS 13947 (Pt-II) 1993 (Latest version) and with Ics = 75% of Icu - 03 Nos.(incoming)
(d) MCCB 63 Amps, 4 pole, 415 Volts, 50 Hz, 16 kA with fixed thermal and fixed magnetic setting with protection for overload and short circuit and conforming to IEC60947 / IS 13947 (Pt-II) 1993 (Latest version) and with Ics = 75% of Icu - 01 No.(incoming)
(e) Three phase contactor with digital timer for security light of capacity 63 Amps - 01Nos.
(f) Multifunction meter digital type with CTs - 01 No
(g) LED type pilot indicator lamps RYB phases with backup fuse, Set of three - 01 No.
(h) The LT panel board shall be of kept on platform 450mm above ground level, mounted on base framework of angle iron 50mm x 50mm x 6mm planted into platform of PCC 1:2:4, type B1, using 20mm graded stone aggregate, over PCC foundation of 100mm thickness in PCC 1:4:8, type D2 using 40mm graded stone aggregate, the exposed concrete surfaces shall be rendered in CM 1:4, 10mm thick, finished fair and even and applied white wash three coats.
M/S.RANGA AND CO
Sri Lakshmi and Company
EVEREST ENGINEERING WORKS
M/s Jai Ganesh Engineering Solutions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .