Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹29.5 LAccepted-AOC | L-1 | Accepted-AOC Lowest and Reasonable | |
| 2 | L-2₹34.1 L+₹2.1 L (6.64%)Rejected-Finance WARD NO 1 HOUSE NO 04 SUBASH NAGAR UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L-2 | Rejected-Finance Other than Lowest | |
| 3 | L-3₹39.2 L+₹7.2 L (22.4%)Rejected-Finance B 56 LANE NO 4A SECTOR 7 VASHNAVI ENCLAVE CHANNI HIMAT JAMMU 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L-3 | Rejected-Finance Other than Lowest | |
| 4 | L-4₹44.3 L+₹12.3 L (38.3%)Rejected-Finance | L-4 | Rejected-Finance Other than Lowest | |
| 5 | L-5₹45.3 L+₹13.3 L (41.4%)Rejected-Finance 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | L-5 | Rejected-Finance Other than Lowest |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
22 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) Jammu
CWE (AF) Jammu C/O 256 SU AF PIN 937256 C/O 56 APO
REPAIR / REPLACEMENT OF HT UG CABLES, GODs AND CONNECTED WORKS AT AF STN UDHAMPUR
2022_MES_525755_1
CWEAFJ-02/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Udhampur
Please refer NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE (AF) Udhampur
₹86,000
Yes
21 Jul 2022
23 May 2022
24 Jun 2022
23 May 2022
22 Jun 2022
8 Jun 2022
60 days
Amount
Excavating in trenches, not exceeding 1.5metre wide and not exceeding 1.5metre depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick any type of soil, complete all as specified and directed.
Removing excavated soils to a distance exceeding 50m but not exceeding 100m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Cement concrete type B-1 1:2:4 (using 20mm graded crushed stone aggregate) as in coping of poles, complete all as specified and directed.
Cement concrete type C-2 1:3:6 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed.
Clearing away all grass vegetation, saplings, shrubs, brushwood, undergrowth, roots, and trees not exceeding 15cm girth and height not excceding 1.5 metres and Loose filling with 40 to 63 mm graded stone aggrgate around Distribution Transformer Yard, MRS Transformer and GOD including removing rubbish to a distance exceeding 250 metres but not exceeding 500 metres, complete all as specified and directed.
Cleaning the Inside and Outside of Sub Station Building / Fencing of Transformer / Two / Four Structure upto and including 2.0 m radius all round the Building / Fencing including taking down unwanted material / grass / vegetable roots / small trees / trimming of branches of trees inside and outside the fencing etc. complete all as specified and directed.
10mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:6, finish surfaces even and smooth without using extra cement, complete all as specified and as directed.
Preparation of surfaces by scrubbing /cleaning the floor /wall and writing letters or figures (Block. Roman, Italic or Indian) not exceeding 30 cm high as per required dimensions with two coats of synthetic enamel paint complete all as specified and as directed.
Preperation of old painted surface and painting Chain Link fencing, Angle Iron and Mild Steel Flat Iron of Sub Station with one coat of synthetic enamel paint complete all as specified and as directed.
Chain link fencing of galvanised steel wire of dia and size of mesh as required at site, conforming to IS : 2721-2003 including line wires, straining bolts, binding wire etc., complete all as specified and directed.
Frame work as in Doors or Gates of angle or other section with gusset plates, rails, braces etc complete, drilled for fixing of steel sheeting or other covering doors etc. to be prepared for hanging or sliding with and including either hook and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete Fe-290 (Gde E-165) complete all as specified and directed.
50mm thick PCC 1:3:6, type C-1 (using 20mm graded crushed stone aggregate) as in sub base of flooring, finished even and fair to receive floor finishes, complete all as specified & directed.
Precast cement concrete coloured glazed interlocking tiles 60mm thick, rubber moulded, conforming to IS-15658, any shade, colour and pattern laid over and including 30 to 40mm thick stone dust / sand cushioning laid dry to the profile including vibrating with surface vibrator after laying of tiles including budding and filleting joints etc. complete including locking the tiles on all four sides with PCC complete all as specified and directed.
Dismantling damaged / perished Locking arrangement of GOD and making new Locking Arrangement with provision of 65 mm Godrej lock with 2 keys complete as directed.
Supply and fixing in replacement Male and Female Blade for GOD including servicing of GOD mounted on pole by cleaning the old grease and greasing of the GOD with new grease including tighting of nuts, bolts and washers of GOD as directed.
Lightining Arrester, expulsion type, (as per existing make / model / capacity to be fixed on existing structure) complete with all fittings, transmission class, discharge capacity 65 Kilo Amps and high current with stand 100 KA outdoor type suitable for 33000 volts including clamps, nuts and bolts, washers and connection to earth with 32 mm x 6 mm GI strip including taking down old unserviceable LA complete as specified and directed
Taking down and refixing after minor repairs Lightning Arresters expulsion type complete (Each Set -03 Nos ) with all fittings, transmission class, discharge capacity 65 Kilo Amp and hight current with stand 100 KA outdoor type for 11000 Volts, including clamps, nuts and bolts, washers and connection to earth with 32mm x 6 mm GI strip/4mm wire complete all as specified and directed.
Preparation of old painted surface and painting with 4 Pole / 2 Pole structure of Steel Tubular HT poles 11 metre long from bottom to top including all iron structure in Zebra pattern 30 cm wide, with synthentic enamel paint in black and yellow colour up to 1.2 metre height from pedestal, including painting of steel structure, cross arms, bracings, supports, clamps and back plates (all metalic parts) of Steel Tubular Pole complete, with two coats of aluminium paint including preparation of old painted steel surfaces including writing in 80mm wide letters / numbers on both side of pole MES, LT / HT and Pole No. complete all as specified and directed.
Disconnecting all existig electrical connection from Four Pole Structure and taking out unserviceable / burnout HT Jumper Cable / conductor with nut, bolt, washer and Supply & fixing PVC insulated sheathed unarmoured stranded aluminium single core cable for HT Jumper of length not less than 2.5 m long in repair / replacement on existing OH circuit / Two Pole / Four Pole Structure etc. including ACSR Conductor (Weasel) using PG Clamps / Lugs, Fastners, Aluminium Lugs, GI Nuts, Bolts, Washer etc. complete as per site requirment all as specified and directed.
Guarding cradles, rectangular, fabricated with galvanised steel wire 3.15mm or 4mm dia including taking down old unserviceable steel wire complete all as specified and directed.
Pin type porcelain vitreous white, brown or green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 150mm height, 150mm dia for 11000 volt complete including taking down old unserviceable insulator complete all as specified and directed.
Disc type porcelain vitreous white, brown or green insulator of 145 mm high and 255 mm dia ball and socket type,including one galvanized spindle two GI washer and one GI nut 150mm height, 150mm dia for 11000 Volts grade including taking down old unserviceable insulator any type complete all as specified and directed.
Disc type porcelain vitreous white, brown or green insulator one galvanized spindle two GI washer and one GI nut 150 mm height, 150 mm dia for 33000 Volts grade including taking down old unserviceable insulator any type complete all as specified and directed.
Danger notice plate of size 25cm x 20cm x 1.6mm thick mild steel sheet, vitreous enameled, white with letters, figures and conventional Skull & Bones in signal red colour and fixed with MS clamps, bolts and nuts of appropriate size, all as specified and as directed.
MS plate made of 1.6 mm thick of size 30 cm x 30 cm fixed with suitable size ms flat iron clamp with nuts, bolts & washers and painted with red colour synthetic enamelled paint and writing of Feeder Name in 8.0cm high letters in white colour as directed.
Disconnecting and taking down old unserviceable cable of any description and Supply and Fixing, Arial Bunched Cable (ABC) 11 KV grade, stranded and compact aluinium phase conductor of size 95 Sqmm 3 Core and 70 Sqmm x 1 Core bare messenger conductor with alumnium alloy. The phase conductor should be insulated with XLPE sioplas compound as per IS:14255-1995 Part-II complete, including all as specified and as directed.
Disconnecting and taking down old unserviceable cable of any description and Supply and Fixing, Arial Bunched Cable (ABC) 11 KV grade, stranded and compact aluinium phase conductor of size 120 Sqmm 3 Core and 95 Sqmm x 1 Core bare messenger conductor with alumnium alloy. The phase conductor should be insulated with XLPE sioplas compound as per IS:14255-1995 Part-II complete, including all as specified and as directed.
Restringing / Restretching / Tightening of existing ACSR conductor of any size and make on HT Poles by disconnecting and removing from insulators including providing necessary binding wire and jumpering after proper stringing all as directed. Note : Three runs of ACSR Conductor i.e. one for each Phase shall be considered as one unit length.
Restringing / Restretching / Tightening of existing Aerial Bunch Cable of any size and make on HT Poles complete all as directed. Note : The contractor shall also repalce any broken / unserviceable fittings viz. Anchor Clamps, Suspension Clamps, On-line Connectors, Dead End Clamps, Mid Span Joints, HT Eye Hooks, Service Clamps, Insulation Piercing Connector etc. all as directed at site. The Quoted Rate shall be deemed to be inclusive of this provision.
Taking Shut down as per IE SOP / guidelines and carrying out repairs to Off Load Rotating Type 33KV / 200 Amps, Air Break Gang Operated Switch and alignment of isolators, blades, arcing horns moving mechanism oiling greasing to Isolators Gear Box assembly tightening renewal / replacement of unserviceable spare / components, nut and bolts complete Air Break Switch unit after carrying out fresh lubrication using Lithium base grease / petroleum jelly and re-fixing the spare parts / components complete all as directed. Note : New spares / components shall be measured and paid separately under respective items.
(a) Supply only metallic (Brass alloy) Fixed Contact Set, single pole including fixing screwed nuts and washers suitable for Air Break Gang Operated Switch of capacity 200 Amps, Three Pole, 33000 Volts grade.
(b) Supply only Post Insulator with GI Post for holding fixed / moving contact assembly including fixing arrangements suitable for Air Break Gang Operated Switch 200 Amps, 33000 volts grade.
(c) Supply only GOD Operating Rod as per existing with cover 33000 Volts grade insulation including locking arrangements with 65mm pad lock (Godrej) with two keys complete.
11KV Fuse of capacity 30 to 200 Amps complete all as specified and as directed.
Disconnecting the HT / LT connections of VCB from inside sub station/plinth and taking out the VCB from inside the Sub Station and shifting the same as directed with the help of Hydraulic Crane and making the connection of the cables as directed at any location in the Cantt area or Lower Camp to Upper Camp in AF Station Udhampur including testing complete as directed.
M&L for tracing the HT / UG Cable fault with HT cable Fault Locator of 33 KV / 11KV system in any situation / position complete as directed. Notes : One Single Cable of any length from end to end termination with any number / type of faults will be considered to consitute one unit of tracing for payment purpose.
Taking down and Re-laying of HT cable of any size after rectifying the fault including jointing and testing, laying in trenches / ducts / pipe or on poles complete all as specified and directed.
Taking down and Re-laying of LT cable of any size after rectifying the fault including jointing and testing, laying in trenches / ducts / pipe or on poles complete all as specified and directed.
Notes for Serial Item No '35' & '36' : 1. If the XLPE Cable is found faulty the same will be replaced with new cable that will be measured and paid under the respective item. 2. Quoted rates shall be inclusive of cutting of cable, provision of thimbles, lugs, stainless steel cable gland for connecting cable IN / OUT from Panels and Feeder Piller Boxes as per Site requirement. 3. The crimping shall be done only by Hand Operated / Hydraulically Operated Crimping Tool after applying conducting jelly and no other method will be allowed.
Supplying laying jointing and testing XLPE insulated, PVC bedded, galvanised steel strips armoured heavy duty electric power cable with stranded aluminium conductor suitable for rated voltage of 11000 Volt grade, 3 Core x 120 Sqmm conforming to IS 7098 Part-2) 2011 with upto date amendments and laid in trenches / ducts / pipe or on poles complete, including taking down old existing unserviceable cable all as specified and directed.
Supplying laying jointing and testing XLPE insulated, PVC bedded, galvanised steel strips armoured heavy duty electric power cable with stranded aluminium conductor suitable for rated voltage of 11000 Volt grade, 3 Core x 95 Sqmm conforming to IS 7098 Part-2) 2011 with upto date amendments and laid in trenches / ducts / pipe or on poles complete, including taking down old existing unserviceable cable all as specified and directed.
Disconnecting and taking down unserviceable Single Core Cable from existing gantary / 33 KV yard and Supply, Fixing and Testing 33 KV grade round PVC insulated stranded aluminium conductor Single Core cable of size 120 Sqmm core earth cable suitable for 33 KV including new lugs, nuts, bolts and washers etc. complete as specified and as directed.
Sand cushioning to underground cables using new dry river sand laid in trenches 8cm thick below the cable and 15cm thick above the cable after laying and stretching the cable complete, punned to 18cm, complete all as specified and directed Note : Punned thickness of 18cms shall be measured for payment.
Supplying and laying un-reinforced precast concrete cable cover, Class HVP, type 1 with peak, size 300mm x 180mm x 40mm, complete all as specified and as directed.
Supply and laying brick covering with width equal to length of bricks as mechanical protection to underground cable using old size sub class 'B' bricks, laid flat of size 230mm x 115mm x 75 mm, all as specified and as directed.
Steel pipe galvanised light grade, 100 mm bore laid in trenches or under ground/floor or road of fixed with pole for protection of cable including GI clamps with bolts nuts and washers complete including taking down old unserviceable Pipe any descriptionall as specified and directed.
Steel pipe galvanised light grade, 80 mm bore laid in trenches or under ground/floor or road of fixed with pole for protection of cable including GI clamps with bolts nuts and washers complete including taking down old unserviceable Pipe any descriptionall as specified and directed.
Cable Jointing Kit for 11 KV (earthed) grade cable for Outdoor Termination Heat Shrink type joint complete with jointing material and accessories suitable for 3 Core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm including taking down old unserviceable kits any description complete all as specified and as directed.
Cable Jointing Kit for 11 KV (earthed) grade cable for Outdoor Termination Heat Shrink type joint complete with jointing material and accessories suitable for 3 Core XLPE armoured aluminium conductor cable of size 50 to 95 Sqmm including taking down old unserviceable kits any description complete all as specified and as directed.
Cable Jointing Kit for 11 KV (earthed) grade cable for Outdoor Termination Heat Shrink type joint complete with jointing material and accessories suitable for 1 Core XLPE armoured aluminium conductor cable of size 95 to 120 Sqmm complete all as specified and as directed.
Cable Jointing Kit for 11 KV (earthed) grade cable for Outdoor Termination Heat Shrink type joint complete with jointing material and accessories suitable for 1 Core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm including taking down old unserviceable kits any description complete all as specified and as directed.
Cable Jointing Kit for 11 KV (earthed) grade cable for Straight Through Heat Shrink type joint complete with jointing material and accessories suitable for 1 Core XLPE armoured aluminium conductor cable of size 50 to 95 Sqmm including taking down old unserviceable kits any description complete all as specified and as directed.
Cable Jointing Kit for 11 KV (earthed) grade cable for Straight Through Heat Shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm including taking down old unserviceable kits any description complete all as specified and as directed.
Cable duct cover, size as per existing ducts of MS sheet of 8mm thick for protection of HT cable line in MRS or from outdoor Transformer / GOD to Indoor VCBs as specified and as directed.
Plate type Cable Route Indicator made out of 100mm x 5mm GI plate welded / bolted on 35 mm x 35 mm x 6 mm Angle Iron 60 cm long duly inscribed "HT CABLE" on the plate. This plate type marker shall be mounted along the cable trench at intervals not exceeding 30 meters. angle iron shall be fixed on PCC foundation and base of the foundation prepared by aggregate of 20mm dia size of ratio 1:2:4 type B-1 and size of the base 150mm x 150mm x 160mm thick all as specified and directed. Note : The Quoted Rate shall include excavating in any type of soil including returning filling in and removal of surplus spoil complete all as directed at site.
Taking up proper shut down as per IE SOP / guidelines and disconnecting up the LT and HT electric mains from Transformer of capacity 3.15 MVA removing the Lid / Cover, Bush / Stud, Gasket, rectifying Oil leakage of Transformer and Oil Seal of Bushing for inspection at site and to facilitate minor repairs after draining out the Transformer Oil, re-assembling the Transformer, refilling the transformer oil (new or old) installing, commissioning and testing at site complete all as specified and directed. Note : All the parts required to be replaced during maintenance shall be measured and paid separately.
Supply and fix in replacement LV Bushing (11 KV side) complete with Brass / Tinned copper rod including nuts, gasket, check nuts and washers complete matching with existing make and type both end threaded of transformer Outdoor rating to 3.15 MVA in replacement, complete all as specified and directed.
Supply and fix in replacement HV Bushing (33 KV side) complete with brass/tinned copper rod including nuts, gasket, check nuts and washers complete matching with existing make and type both end threaded of transformer outdoor rating to 3.15 MVA in replacement, complete all as specified and directed.
Silica Gel (deep sky blue colour) for replacement in breathers of outdoor transformer of rating to 3.15 MVA in replacement, complete all as specified and directed.
Supply, filling and top up with new Transformer Oil of dielectric strength more than 60 KV at 2.5mm gap confirming to IS : 335-1993 complete all as specified and as directed.
Dehydration of transformer oil by using filtration plant of suitable capacity and removing the moisture / dust till obtaining the oil dielectric strength 60 KV at 2.5mm gap and above for various transformer / voltage stabilizer of any size located at different substations, complete all as specified and as directed.
Gasket Set of synthetic rubberized cork sheet with suitable holes for transformer of rating 3.15 MVA complete all as specified and directed.
Copper bus bar any rating including cutting / drilling of suitable size holes as per site requirement including copper nuts, bolts, washers etc. complete including taking down old unserviceable bus bar any type as specified and directed.
Aluminium bus bar any rating including cutting / drilling of suitable size holes as per site requirement including GI nuts, bolts, washers etc. complete including taking down old unserviceable bus bar any type as specified and directed.
Disconnecting the HT / LT connections of the Transformer from Pole / inside Sub Station / Plinth and taking out the Transformer from Poles / Plinth / inside the Sub Station and shifting the same with the help of Hydra / Crane and making the connections of the HT & LT side as directed at any location inside the Cantonment Area including testing complete as directed.
Platform for Transformer of size 3.0m x 3.0m x 1.0m high from Ground Level including excavation in trenches in any type of soil, returning filling in and removal of surplus spoil to a distance not exceeding 50metres, PCC 1:5:10 type E-2 for foundation, brick work in cement mortar 1:6, PCC 1:2:4 type B-1 as in coping, 10mm thick plaster in cement mortar 1:6 on brick surface complete with 75 mm thick PCC 1:4:8 type D-2 as in sub base of floor with topping of PCC 1:2:4 type B-1 100 mm thick in floor and finished fair (without using extra cement), Chain Link Fencing for the Transformer Plinth of 1.8 m height made out of 4.0 mm dia GI wire 150mm x 100 mm mesh with MS Angle Iron 50 x 50 x 6mm as in Fencing Post and embeded in PCC 1:2:4 type B-1 30cm x 23cm x 30cm block at 2 mtr interval each side as approved with one No Steel Gate (3.5 metre clear span)
with locking arrangement made out of 15 mm dia MS Rod 50 x 50 x 6mm Angle Iron Frame and painting the Steel surface with two coats of aluminium paint over a coat of red oxide primer and three coats of white washing on cement work including ISMB 100 mm channel 2 Nos for fixing transformer complete all as specified, and as directed.
Spray Painting of complete Transformer 3.15 MVA capacity with one coat of weather proof synthetic enamel paint after cleaning / removing dust, rust or carbon etc. including writing MES No / SM No complete all as specified and as directed.
Electric Shock Chart, dust proof, water proof with precautions to be taken for protection from electric shock and its treatment written in English and Hindi for Sub Stations complete fixed on good quality wooden frame with glass of size 50cm x 75 cm all as specified and directed.
Electric Line Diagram of each Sub Station on the chart, dust proof, water proof showing electric diagram of a particular Sub Station with name written in English and Hindi for Sub Stations complete fixed on good quality wooden frame with glass of size 50cm x 75 cm all as specified and directed.
Rubber Matting, chequered type, suitable for upto 11 KV rating as per IS 15652-2006, (superseding IS 5424) of size 2.0 m x 1.0 m x 2.5mm thick all as specified and as directed.
Maintenance and complete overhauling of 11 KV VCB of Make Crompton / Kirloskar / Alstom including disassembling of operating mechanism parts, well greasing of springs / repair of mechanical parts, spring charge assembly and reassembling of parts including well cleaning the complete panel board, main bus bar, de-carbonising all joints Bus Bar, CTs, PTs, spouts metal parts and making VCB perfect operating in manual and electric mode including all routine and preventive maintenance complete and replacing unserviceable parts, rewiring the control circuit / LT circuit and components etc. complete all as specified and directed.
Notes : 1. The above job to be carried out by engineer of authorised dealer / service centre of concerned OEM. 2. Replacement of new items shall be measured and paid separately as supply only. The labour charges for fixing shall be included in this item. 3. Minor items such as nuts, bolts / pins and internal control wiring are deemed to be included in the quoted rate. 4. The contractor shall arrange for the standby supply for testing of relays.
(a) Closing Coil, indoor type, for 11 KV VCB in replacement as per existing Make / Model / Capacity complete all as specified and directed.
(b) Triping Coil, indoor type, for 11 KV VCB in replacement as per existing Make / Model / Capacity complete all as specified and directed.
(c) Spring Charging Motor suitable for fixing with 11 KV indoor type VCB panel as per existing Make / Model / Capacity complete all as specified and directed.
(d) Insulator of VCB as per exising Make / Model / Capacity complete all as specified and directed.
(e) Digital Voltmeter / Ammeter as per existing Make / Model / Capacity complete all as specified and directed.
(f) Indicator Lamp as per existing Make / Model / Capacity complete all as specified and directed.
(g) Cast Rezin wound CT of ratio 400 / 200 / 5 / 5A as per existing Ratio / Make / Model / Capacity complete all as specified and directed.
(h) Cast rezin wound PT as per existing Ratio / Make / Model / Capacity complete all as specified and directed.
(j) Isolating Contact, flat type as per existing Make / Model / Capacity / Size complete all as specified and directed.
(k) TNC Switch (Tripping Neutral & Closing) as per existing Make / Model / Capacity complete all as specified and directed.
(l) Power Pack Units with maintenance free batteries in sheet metal enclosure as per existing Make / Model / Capacity complete all as specified and directed.
(m) High Voltage Fuse as per existing Make / Model / Capacity complete all as specified and directed.
(n) VCB Panel Spout as per existing Make / Model / Capacity complete all as specified and directed.
(o) Trip Fork Lingage Assembly as per existing Make / Model / Capacity complete all as specified and directed.
(p) Insulating Gear Charging Handle as per existing Make / Model / Capacity complete all as specified and directed.
(q) Ratchet wheel as per existing Make / Model / Size etc. all as specified and directed.
(r) Pin for ratchet as per existing Make / Model / Size etc all as specified and directed.
(s) Relay assembly as per existing Make / Model / Capacity / Size complete all as specified and directed.
Maintenance and servicing, tunning, caliberation and testing of RMU/SF6 gas filled Circuit Breaker / Isolator / Remote Panel of make : Schnieder-Electric including checking of all electrical wiring, disassembling of operating mechanism parts, well cleaning, replacing unserviceable parts and accessories, oiling/greasing of moving parts including reassembling, fine setting of mechanism, and making SF6 Breaker in perfect operational in manual and electrical mode including well cleaning the complete panel board, main bus bar coupler, decarbonizing all joints, bus bars coupler, CTs, PTs, spouts metal parts and replacing unserviceable parts and components complete, all as specified and directed.
Notes : 1. The above job to be carried out by engineer of authorised dealer / service centre of concerned OEM. 2. Replacement of new items shall be measured and paid separately as supply only. The labour charges for fixing shall be included in this item. 3. Minor items such as nuts, bolts / pins and internal control wiring are deemed to be included in the quoted rate. 4. The contractor shall arrange for the standby supply for testing of relays.
(a) RMU Protection Relay DPX-V5 as per existing Make / Model / Capacity / Size complete all as specified and directed.
(b) Spring Charging Motor (230 Volt AC) as per existing Make / Model / Capacity / Size complete all as specified and directed.
(c) Spout for Breaker as per exising Make / Model / Capacity / Size complete all as specified and directed.
(d) Digital Multifunction Meter as per existing Make / Model / Capacity / Size complete all as specified and directed.
(e) Interlocking Bush between A & K mechanism as per existing Make / Model / Capacity / Size complete all as specified and directed.
(f) Digital Indicator Lamp for breaker ON/OFF/Trip/Breaker spring charged/R-Y-B etc in 11 KV HT panel including associated wiring, if required complete all as per existing Make / Model / Capacity / Size complete all as specified and directed.
(g) Cast Rezin Wound CT of ratio 100-50/1 as per existing Ratio / Make / Model / Capacity / Size complete all as specified and directed.
(h) Cast Rezin Wound PT as per existing Ratio / Make / Model / Capacity / Size complete all as specified and directed.
(j) Battery of RMU (24 Volt) as per existing Make / Capacity
(k) 2PA machanism w/o hex rod as per existing Make / Model
(l) Linkage between K and A as per existing Make / Model
(m) PKE mechanism w/o Hex rod as per existing Make / Model
(n) Locking Arrangement Handle for RMU as per existing Make / Model
(o) Terminal Protector Silca for 11 KV as per existing Make / Model
(p) Voltage Presence Indicator as per existing Make / Model
(q) Battery 12 VDC, 12 AH of relay as per existing Make / Model
Prediodical serving CR Panel of 11 KV rating in such as checking of all wiring connection of differential relay and auxilliary relays & blowing out dust, caliberation of relay & repair and replacement of defective components as per existing make/model/capacity of 33 KV CR panel incl connecting the all electrical connection and testing complete all as specified and directed. Make : ABB CR Panel or equivalent
Notes : 1. The above job to be carried out by engineer of authorised dealer / service centre of concerned OEM. 2. Replacement of new items shall be measured and paid separately as supply only. The labour charges for fixing shall be included in this item. 3. Minor items such as nuts, bolts / pins and internal control wiring are deemed to be included in the quoted rate. 4. The contractor shall arrange for the standby supply for testing of relays,
(a) Test Terminal Block as per existing Make / Model / Capacity
(b) DC Supervision Relay as per existing Make / Model / Capacity
(c) AC Super Vision Relay as per existing Make / Model / Capacity
(d) Kit Kat Fuse as per existing Make / Model / Capacity
(e) Temp Winding / Winding Temp Alarm Relay as per existing Make / Model / Capacity
(f) Supervision Relay for trip circuit as per exising existing Make / Model / Capacity
(g) Master Trip Relay as per existing make/ model/capcity
(h) Buch Trip / Buch Alarm Relay as per existing Make / Model / Capacity
(j) PRV Trip / PRV Alarm Relay as per existing Make / Model / Capacity
(k) Annaunciators as per existing existing Make / Model / Capacity / size
(l) RET-Trafo Differential Protection (RET 615) Relay as per existing Make / Model / Capacity
(m) Indicator of Red / White / Green / Blue / Yellow colour as per Make / Model / Capacity
(n) MFM - Multifunction Meter AE - 900 as per Make / Model / Capacity
(o) Push Button of Green / Yellow / Red colour as per existing Make / Model / Capacity
Transporting the defective Transformer 3.15 MVA capacity for repair from MRS of GE (AF) Udhampur to civil workshop and vice versa including loading / unloading with the help of hydraulic crane of capacity not less than 10 Tonnes for carrying out the repairs / replacements works mentioned here-in-after, complete all as specified and as directed.
Material & Labour for re-winding with existing size of copper wire suitable for 3.15 MVA, 33/11 KV, 50 Hz Power Transformer alongwith HT Paper insulating, varnishing and furnace drying complete all as specified and directed.
Reassembling, Installation, commissioning and testing Power Transformer of capacity 3.15 MVA Step Down, Outdoor type, Floor Mounted, double copper wound Three Phase, 50 cycles, AC Oil immersed, natural air cooled (ON type) having no load voltage ratio 33000/11000 volts (corresponding to principle tapping), winding delta connected to primary side (HV side) and star connected to secondary side (LV side) in accordance with vector symbol DY-11 (Vector group-4) with neutral brought out to separate insulated terminal for earthing, and mainly comprising of the following accessories and fittings complete all as specified and directed. Note : HT Paper insulation, varnishing, furnace drying, gasket etc shall be deemed to be included in the quoted rate.
Earthing complete with Galvanised steel earth plate electrode 600 mm x 600 mm x 6mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50 mtr below ground level connected to GI Strip of size 32 x 6mm as earth lead by means of bolts, nuts and washers of GI up to test point, GI tubing 40 mm bore light grade protection pipe, GI watering pipe 20mm bore medium grade with funnel and wire mesh, alternate layer of charcoal and salt, 40mm thick including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m) and connecting, testing on completion, all as shown on Electric Plate No. 03 of SSR-2009 Part-I, complete all as directed.
Earthing complete with copper earth plate electrode 600mm x 600mm x 3.15 mm buried directly in ground not less than 2.25 metre deep below normal ground level with top edge of earth plate not less than 1.25 metre below the normal ground level connected to the copper strip 20 x 3 mm size by means of bolts, nuts, check nuts and washers of galvanised iron and 20 x 3 mm copper strip protected by provision of GI light grade pipe 40 mm bore including provision of concrete pit in PCC 1:2:4 type B-1, using 20 mm graded stone aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPM weight
not less than 4 Kg/Sqm and 6mm dia bar handle, excavation and earth work in any type of soil, charcoal dust and salt light grade GI watering pipe 20mm bore with funnel and wire mesh and medium grade GI protection pipe 15mm bore 5.0 metre long and GI strip upto main earthing of pole complete all as shown in Electrical Plate No 5 of MES Schedule 1991 Part-I all as specified and directed.
DAVINDER SINGH
ANIKET TRADERS
proach associates
MOHAN LAL AND SONS
LUXMI ELECTRONIC WORKS
Bidder Name
proach associates
MOHAN LAL AND SONS
ANIKET TRADERS
LUXMI ELECTRONIC WORKS
DAVINDER SINGH
shivom builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .