Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹50.4 CrAccepted-AOC CHINAR COMMERCIAL COMPLEX THE BUND RESIDENCY ROAD SRINAGAR 190 001 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190001 | ₹50.4 Cr Quoted ₹50.5 Cr | L1 | Accepted-AOC LOWEST TENDERER. |
| 2 | L2₹61.8 CrRejected-AOC L 87 STREET NO 7C MAHIPALPUR EXTENSION NEW DELHI 110037 | NEW DELHI | NEW DELHI | DELHI | 110037 | ₹61.8 Cr | L2 | Rejected-AOC NOT LOWEST TENDERER. |
| 3 | L3₹61.9 CrRejected-AOC F 18 ANSAL COMPLEX OPP JWALA HARI MARKET PASCHIM VIHAR NEW DELHI 110063 | NEW DELHI | WEST DELHI | DELHI | 110063 | ₹61.9 Cr | L3 | Rejected-AOC NOT LOWEST TENDERER. |
| 4 | L4₹68.6 CrRejected-AOC | ₹68.6 Cr | L4 | Rejected-AOC NOT LOWEST TENDERER. |
Tender Value
₹62.8 Cr
EMD Value
₹15 L
Closing Date
16 Dec 2019, 6:00 pmClosed
CHIEF ENGINEER AF NAGPUR
HQ CHIEF ENGINEER AF, VAYUSENA NAGAR, NAGPUR 440007
WORK SERVICES FOR CONSTRUCTION OF INFRASTRUCTURE FOR MLH UPGRADE AT AF STATION CHANDIGARH
2019_MES_287009_2
CA NO. CE(AF)/NGP/CHD/ OF 2019-20 800147/E8
Open Tender
Civil Works
790 days
GE AF MC CHANDIGARH
as per NIT
8 documents required · 8 mandatory
₹3,000
GE AF MC CHANDIGARH
₹15 L
11 Feb 2020
27 Nov 2019
18 Dec 2019
27 Nov 2019
16 Dec 2019
2 Dec 2019
Amount
Lumpsum price worked out by the contractor for “BUILDING AND STRUCTURES (PEB hangar fand Annexe)” as listed in Sch ‘A” part IA on srl page No 39
Lumpsum price worked out by the contractor for “BUILDING WORK” as listed in Sch ‘A” part I(B) representing above / below the lumpsum price as inserted by MES for Sch ‘A’ Part I(B) on srl page No 46
Lumpsum price worked out by the contractor for “DEMOLITION” as listed in Sch ‘A” part II representing above / below the lumpsum price as inserted by MES for Sch ‘A’ Part II on srl page No. 48
Lumpsum price worked out by the contractor for “SITE CLEARANCE AND EARTH WORK” as listed in Sch ‘A” part III representing above / below the lumpsum price as inserted by MES for Sch ‘A’ Part III on srl page No. 49
Lumpsum price worked out by the contractor for “PROVISION OF STORAGE SHED” as listed in Sch ‘A” part IV(A) representing above / below the lumpsum price as inserted by MES for Sch ‘A’ Part IV(A) on srl page No.52
Lumpsum price worked out by the contractor for “INTERNAL WATER SUPPLY” as listed in Sch ‘A” part IV(B) representing above / below the lumpsum price as inserted by MES for Sch ‘A’ Part IV(B) on srl page No.53
Lumpsum price worked out by the contractor for “INTERNAL ELECTRIFICATION” as listed in Sch ‘A” part V above/below the lumpsum price as inserted by MES for Sch ‘A’ part V on srl page No. 54
Lumpsum price worked out by the contractor for “EXTERNAL WATER SUPPLY” as listed in Sch ‘A” part VI representing above / below the lumpsum price as inserted by MES for Sch ‘A’ Part VI on srl page No. 55
Lumpsum price worked out by the contractor for “EXTERNAL ELECTRIFICATION" as listed in Sch ‘A” part VII representing above/below the lumpsum price inserted by MES for Sch ‘A’ Part VII on srl page No. 58
Lumpsum price worked out by the contractor for “FLAME PROOF LIGHT FITTING” as listed in Sch ‘A” part VIII representing above / below the lumpsum price as inserted by MES for Sch ‘A’ Part VIII on srl page No. 59
Lumpsum price worked out by the contractor for “CONDUITS FOR TELEPHONE AND AF NET CABLING” as listed in Sch ‘A” part IX representing above / below the lumpsum price as inserted by MES for Sch ‘A’ Part IX on srl page No.60
Lumpsum price worked out by the contractor for “ADDITIONAL E/M ITEMS " as listed in Sch ‘A” part X representing above/below the lumpsum price as inserted by MES for Sch ‘A’ Part X on srl page No. 61
Lumpsum price worked out by the contractor for “ROAD/ PATH/ HARDSTANDING " as listed in Sch ‘A” part XI representing above/below the lumpsum price as inserted by MES for Sch ‘A’ Part XI on srl page No. 63
Lumpsum price worked out by the contractor for “SEWAGE DISPOSAL " as listed in Sch ‘A” part XII representing above/below the lumpsum price as inserted by MES for Sch ‘A’ Part XII on srl page No.65
Lumpsum price worked out by the contractor for “AREA DRAINAGE” as listed in Sch ‘A” part XIII representing above / below the lumpsum price as inserted by MES for Sch ‘A’ Part XIII on srl page No.67
Lumpsum price worked out by the contractor for “Hangar floor/ Tarmac/ Taxi track” as listed in Sch ‘A” part XIV representing above / below the lumpsum price as inserted by MES for Sch ‘A’ Part XIV on srl page No.68
Lumpsum price worked out by the contractor for “LIGHTENING PROTECTION” as listed in Sch ‘A” part XV representing above / below the lumpsum price as inserted by MES for Sch ‘A’ Part XV on srl page No.69
Lumpsum price worked out by the contractor for “PNEUMATIC SUPPLY” as listed in Sch ‘A” part XVI representing above / below the lumpsum price as inserted by MES for Sch ‘A’ Part XVI on srl page No.70
SCH 'A' PART XVII (MISC B/R & E/M ITEMS) Note:- Excavation and earthwork to the extent required for execution of relevant item under this schedule unless otherwise specified shall be measured and paid under relevant items of Sch 'A' Part-III.
DEMOLITION
Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15 cm thickness below or above ground level and removing the demolished materials outside the defence land complete all as specified.
Demolition of cement concrete (reinforced) in roofs, floors (other than ground floors) beams, beams, staircases, landing, chajjas and similar suspended work and removing the demolished materials outside the defence land complete all as specified and directed.
Taking up PTMT bib taps, pillar taps, any dia complete all as directed
Taking up PTMT stop valve/ angle valve, any dia complete all as directed
Taking down old LT cable of size 10 Sqmm 2 core complete all as directed
Taking down old DB any type and any size complete all as directed.
SITE CLEARANCE AND EARTHWORK
Removing suprplus soil outside the defence land complete all as directed.
INTERNAL WATER SUPPLY
Supply and fix 15mm (Concealed) stop cock of cast copper alloy chromium plated fancy type screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
INTERNAL ELECTRIFICATION
Material and labour for point wiring (surface) in and including rigid non-metallic PVC heavy duty conduit, 20 mm dia/suitable size as per site requirement including cutting chases for conduits sinking for boxes for concealed conduit wiring with 1.5 sqmm PVC insulated unsheathed FRLS multi standed copper conductor cable with flush type metal boxes modular type suitable for fixing modular switches sockets fan regulator etc with white or any colour cover plate with brass screw cap washer and including PVC insulated unsheathed multi standed copper conductor cable of 1.5 sqmm as an earth wire connnected to common earth and earth dolly as per IS specification & as specified for One light point controlled by one switch. :- (Rates deemed to be including mounting concealed boxes and modular cover plates of suitable module) (a) One light/fan controlled by one switch.
All as per Item No. 22 here in above but for One 3 pin 5 Amps switch socket outlet point on same board
All as per Item No. 22 here in above but for One 3 pin 5 Amp switch socket outlet point on independent board
All as per Item No. 22 here in above but for socket outlet 3 pin 15/16 Amps on independent board with cable size of 2.5 sqmm and earth continuity conductor cable of size 2.5 sqmm.
Supply and fix T-8 4ft tube light fitting with LED tube rod 4ft 20watt having lumen output > 2000 lumens, efficiency 110lm/watt, CRI>80, THD<30% and PF >.90, colour temperature 6500 ± 500K, having life > 50000 burning hours with PC diffuser including making connection complete all as specified and directed.
Supply, installation, testing & commissioning of LED recess troffer luminaire with a normal system lumen output of 3500 lumen and minimum system efficiency of 90lm/w. The luminaire shall have a rated system life time of 50000 burning hours at L70. The luminaire colour temp. shall not exceed 5700K and CRI >80. The luminaire shall meet IP 20 rating with THD<10% and PF>.90. The luminaire housing should made of powder coated metallic CRCA with light efficiency OPAL diffuser. The total power consumption shall not exceed 36W (including driver) complete all as specified and directed.
Supply and fixing surface & wall mounted decorative ultra slim linear LED lightining fixture with co extruded polycarbonate body environmental friendly energy efficient 9 W,with electronic driver suitable for 240 volts AC input. with copper wire to be connected with the ceiling rose complete with all accessories all as specified and directed, Make ; HAVELLS LUMILNEBS 9WLED830 SPCWH-9405 / CG ; LCTL-9-CDL or equivalent to specified makes.
Supply and fixing building security light LED aesthetically designed IP 65 protection complied to IEC 60598 and IS 10322 high power LED cool white, with integral driver, 25 Watt power consumption pressure die cast aluminium body including reduced glare inpact resistant polycarbonate cover prewire complete with light bracket made out of GI pipe light grade 32 mm OD 1.2 mtrs long bent to shape fixed with two set of clamps nut bolts washer etc all as specified and as directed. Make ;Havells :ENDURACITYLITEPLATSL 25WLED757SASYBOPC / BAJAJ : 169826BRLEP25WLEDWH/ CROMPTON : LSTS-25-CDL.
Supply and fix ceiling fan 1200 mm sweep single phase 230 V 50 Hz copper wound including condensor, connector, canopy, down rod, clamps, etc complete with all acessories internally pre wired and including connecting up with three core 0.5 sqmm flexible copper conductor cable complete as per BEE standard 5 star rating ISI marked, white color all as specified and directed by Engg-in-charge, Make : CG Empower 50 series/USHA Technix flair/Orient /Smart.
Supply & Fix exhaust fan 300 mm sweep with louvers complete with connection including making hole, plastering etc, making good with the existing wall for fixing of exhaust fan and all as specified and as directed.
M & L for sub main wiring (concealed) complete with Two single core 4.0 Sqmm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through in and including 20 mm dia rigid non-metallic PVC conduit and conduit accessories including one single run of 4.0 Sqmm FRLS PVC insulated unsheated stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface all as specified and directed. Note:- Three runs of 4 sqmm cable and one run of PVC conduit shall be measured as one unit.
M & L for sub main wiring (concealed) complete with four single core 6.0 Sqmm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through in and including 20 mm dia rigid non-metallic PVC conduit and conduit accessories including two run of 6.0 Sqmm FRLS PVC insulated unsheated stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface all as specified and directed Note:- Six runs of 6 sqmm cable and one run of PVC conduit shall be measured as one unit.
M & L for sub main wiring (concealed) complete for security light fittings with Two single core 1.5 Sqmm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through in and including 20 mm dia rigid non-metallic PVC conduit and conduit accessories including one single run of 1.5 Sqmm FRLS PVC insulated unsheated stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface all as specified and directed. Note:- Three runs of 1.5 sqmm cable and one run of PVC conduit shall be measured as one unit.
S&F Vertical Loadline DBs TPN 8 Ways with provision for MCCB as incomer and MCB SP/SPN 6-32 Amps as outgoing fitted with Bus Bas, Nutral Links Blanking Plate, door earthing without MCCB as percomplete double door concealed in wall and making good distrubed surface area IP 43 protection including connection etc. with proper size copper cable lugs, connector etc complete all as specified and directed. Make ; L&T Cat Part No LTPCD04NS, Legrand Ekinox DPX3 160 Series cat part No. 507745/Havells Cat Part No DHDLVDRWAOFO04 or equivalent in Siemens.
S & F MCCB 4 pole 63 Amps Á'frame , breaking capacity 25 KA confirming to IES 60947-2 including making connection complete all as specified and directed. Make : Legrand.Cat No. 027029/ C & S ; CSE1M125ATM4P63 /L & T ; CM97933OOH2/ or equvellant to Havells.
S & F MCB SPN 16 to 32 Amps breaking capacity 10 KA C series single phase 240 volts including making connection complete all as specified and directed. Make ; Leagrand cat no. 408614 to 408617 /Havells cat No. ; DHMGCSNF006 / or equivalnt in L&T/Seimens.
S & F MCB SP 6 TO 32 Amps breaking capacity 10 KA C series single phase 240 volts including making connection complete all as specified and directed. Make : Legrand cat no 408587 to 408595 / L & T cat No. BB10200C / Havells ; DHMGCSPF006 or equivalent in Siemens.
S & F MCB TP 63 Amps breaking capacity 10 kA three phase 415 volts including making connection complete all as specified and directed. Make : Legrand cat part no 408683 / Havells ; DHMGCTNF063 or equivalent in Siemens.
S & F Sheet metal enclosure for DB when MCBs to be used SP&N double door IP 43 protection 240 volts with 200 Amps rated busbar 4 way complete all as specified and directed. Make : Leagrand Ekinox-cat no. 507610 / Honeywell ; 85371000-S4WSPNDD / L&T/Seimens.
S & F Sheet metal enclosure for DB when MCBs to be used SP&N double door IP 43 protection 240 volts with 200 Amps rated busbar 8 way complete all as specified and directed. Make : Leagrand Ekinox-cat no. 507610 / Honeywell ; 85371000-S6WSPNDD / L&T/Seimens.
BLANK
FLAME PROOF LIGHT FITTINGS
Material and labour for flame proof point wiring complete with 1.5 Sqmm PVC insulated FRLS copper conductor including ERW steel conduits surface including all accessories like bends, tees and including 1.5 Sqmm PVC insulated FRLS copper conductor used as earth wire including making good to the disturbed surface to existing with surfaced solor complete all as specified and directed.
Material and labour for flame proof/ weather proof exhaust fan 450mm dia with single phase complete all as specified and directed.
Material and labour for flame proof/ weather proof rotary switches/ isolator 10 Amps 220 Volt single phase complete all as specified and directed.
Supply and fix flame proof weather proof factory made sheet metal enclosures DB, SPN 08 ways, 240 volts (protection class IP 42) with following MCBs:- (a) SPN 20 Amps 240 Volt- 01 No. (b) SP 6 to 16 Amps 240 Volts- 06 Nos
Material and labour for Earthing complete with galavanized steel earth electrode, 600x600x6.00 mm thick, buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level,
connected to galvanized earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No-3 connected to earthing test point all as specified or indicated including testing on completion including PCC pit type C-1 (M-10) in cement concrete & 40 mm thick precast RCC cover in (M-15) type B-1 reinforced with 8 mm dia MS round bar @ 75 c/c both ways with 02 Nos lifting handles of 12 mm dia MS plain bar, GI pipe 20 mm dia medium grade with funnels & wire mesh for watering and 15 mm dia light grade GI pipe for earth lead protection etc including necessary earth work and excavation complete all as specified and directed. Note:- Quantity of GI earth lead & protection pipe beyond 7.5mtrs length will be measured separtely.
Supply and fix tube light fitting LED flameproof fittings 1x20watt, IP 65 protection made of aluminium alloy LM6, with electronic driver connector block etc. complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
ADDITIONAL E/M ITEMS
M&L for chemical earthing with copper strip as per details specified below :- (a) The earthpit shall be of size 1.2m x 1.2m and of depth (minimum) 3.6m. (b) Copper plate 90cm x 60cm x 5mm. (c) Copper strip 50mm x 6mm (cross section) (d) Chemicals of quantity (i) Charcoal-250kg (ii) Salt crystal 200 kg (iii) Magnesium sulphate -100 kg. (e) 25mm dia GI watering pipe medium grade above copper plate filled with funnel wire alongwith cap. (f) Copper strip shall be provided with GI protection pipe of 40mm dia light grade upto test block.
Material and labour for MCB DB SPN 8 way IP-43 double door concealed in wall with MCB SPN 32 Amps 01 No I/C and MCB SP 'C' curve type 6 to 16 Amps 06 Nos O/G including necessary connection lugging with copper lugs pin/ Ring type making good disturbed surfaces to match with existing surface/ wall complete all as specified and directed.
Material and labour for MCB DB TPN 4 way IP-43 double door concealed in wall with MCB TPN 63 Amps 01 No I/C and MCB SP 'C' curve type 6 to 16 Amps 12 Nos O/G including necessary connection lugging with copper lugs pin/ Ring type making good disturbed surfaces to match with existing surface/ wall complete all as specified and directed.
Material and labour for MCB DB TPN 8 way IP-43 double door concealed in wall with MCCB TP 125 Amps 01 No I/C and MCB TPN 'C' curve type 63 Amps 03 Nos and MCB SP 6 to 16 Amps 12 Nos O/G including necessary connection lugging with copper lugs pin/ Ring type making good disturbed surfaces to match with existing surface/ wall complete all as specified and directed.
Supply and fix sheathed copper cable flexible type 25 Sqmm 4 core unarmoured 1100 Volt grade from panel to DB TPN 8 way complete all as specified and directed.
Supply and fix sheathed copper cable flexible type 16 Sqmm 4 core unarmoured 1100 Volt grade from panel to DB TPN 4 way complete all as specified and directed.
Supply and fix metra plug and socket DBs 4 modules with 32 amps MCB complete with electric connection complete all as specified and directed. Make: Cat Part No. 507862 of Legrand or equivalent to specified makes.
Supply and fix tempra plug and socket DBs 4 modules with 63 amps MCB complete with electric connection complete all as specified and directed. Make: Cat Part No. 507864 of Legrand or equivalent to specified makes.
Supply and install pedestal fans of 400mm sweep complete all as specified and directed. Make: CG/ Havells
Supply and fix wind driven turbo ventilator outer dia 30'' effective throatal 24'' air changes 15/hr and fan diameter 600mm speed 4m/s, air volume 600mm complete all as specified and directed. Make: Mercury enterprises or equivalent make
Supply, install, testing and commissioning clean cabinet of size 7 feet x 4 feet x 3 feet of class 100000 (as per federal standard) including with PVC sheet and all standard fittings complete all as specified and directed.
Supply, install & testing of air curtain SP, 230 Volts, electric driven, 3m wide to install above the entrance on top of the door of 5 feet width complete all as specified and directed.
Supply, installation, testing and commissioning of LED high bay luminare complete with mounting arrangement such as chain/flat iron/angled iron or any other suitable arrangement as per site requirement duly fixed in roof/girder/ channel with minimum system lumen output 20000 lumens and minimum system efficiency of 105 lumens/Watt. The luminaire shall have a rated system lifetime of 50,000 burning hours the luminaire should have a colour temperature of 6500k and CRI>70. The luminaire shall meet IP-65 rating with THD<20% and P.F.>0.95. The luminaire housing should be made of high pressure die cast aluminum with sealed toughened glass. The total power consumption including driver should not exceed 210 Watt complete all as specified and directed
Material and labour for Aviation obstruction light 240 Volt complete all as directed. Make: Cat Part No. XGP 400I X LED-K2/RD of Phillips or equivalent to the specified makes.
Supply and fix submain wiring alongwith earth wire with the cable of size 4 X 16 Sqmm + 2X16 Sqmm earth wire, FRLS, PVC insulated copper conductor, single core, including PVC conduit of size 40mm dia complete all as specified and directed. Note:- 4 runs of 16 sqmm cable, 1 run of PVC conduit and 2 run of earth cable 16 sqmm shall be measured as 1 unit.
All as per item No. 62.10 herein before but cable of size 4x10 Sqmm + 2x10 Sqmm earth wire including PVC conduit of size 40mm dia Note:- 4 runs of 10 sqmm cable, 1 run of PVC conduit and 2 run of earth cable 10 sqmm shall be measured as 1 unit.
All as per item No. 62.10 herein before but cable of size 4x6 Sqmm + 2x6 Sqmm earth wire including PVC conduit of size 25mm dia Note:- 4 runs of 6 sqmm cable, 1 run of PVC conduit and 2 run of earth cable 6 sqmm shall be measured as 1 unit.
All as per item No. 62.10 herein before but cable of size 2x4 Sqmm + 1x4 Sqmm earth wire including PVC conduit of size 25mm dia Note:- 2 runs of 4 sqmm cable, 1 run of PVC conduit and 1 run of earth cable 4 sqmm shall be measured as 1 unit .
AREA DRAINAGE
Material and labour for RCC M-30 (Design mix) as in cover slabs including necessary formwork complete all as specified and directed.
Material and labour for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in surface channels and drains including rounding to any radius inside manholes and copings etc and necessary use and waste of formwork with smooth finish and required slope complete all as specified and directed.
SEWAGE DISPOSAL
Material and labour for LLDPE septic tank for 25 users designed to carry sewage and sludge water, excavation in any type of soil, PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) below foundation, vent shaft, connection etc complete all as specified and directed.
Material and labour for Soakage well 1.2m X 3m effective depth, excavation in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonary with top ring of M-25 concrete including intercepting chamber and screen chamber made of brick masonary in CM, RCC cover slab in M-25/ SFRC cover, interconnecting pipe of RCC/ DWC complete filled with brick bats complete all as specified and directed.
LIGHTENING PROTECTION
Supply and fix aluminium strip 25x3mm as roof/ down earth continuity conductor including fixing arrangement with epoxy insulator at a distance of 450mm complete all as specified and directed.
Material and labour for test point terminal block made of gun metal or phosphorous bronze size 75x75x25mm drilled and screw and connected to existing aluminium/ GI strips complete including 3Nos,, 8mm dia, 25mm long hexagonal head screw complete and including fixing of test point with sheet metal enclosure on insulators to isolate from the walls, fixing of insulators on wall using suitable size of screws, washers, gutti/ rawal plugs etc., including making good disturbed surfaces complete all as specified and directed.
FLOOR MOUNTED AC (PACKAGE TYPE)
Supply, installation, testing and commissioning of air cooled package type floor mounted A/C capacity not less than 11TR suitable for operation 415V, 3Ph 50 C/s A/C housing double scroll compressor in body of indoor unit safety devices microprocessor controlled panel and flexible air supply hose type ducting heavy duty, air flow not less than 50 feet complete set as directed machine having minimum CMH- 11220 indoor air flow eco friendly refrigerant i.e R 407 C, minimum 3 HP indoor blower motor to maintain air flow, 3 row deep indoor coil and 220 watt operation i.e cool, dry, fan & energy save made self having full body SS diagnosis function auto start mode, motor protection device anti recycle timer in built temperature sensor complete all as specified and directed Make: Voltas/ Blue Star/ LG.
WATER COOLER
Supply, installing, testing and commissioning of water coolers electric driven (single phase) having approx storage capacity 120 litres and nominal cooling capacity of 60 litres per hour complete all as specified and directed. Make: Voltas/ Blue star/ Sidhwal
Supply and fix 1.0 KVA voltage stabilizers for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170V to 250Volt with output voltage stabilised at 230 volts with accuracy of ±2.5% complete all as specified and directed. Make: V-Guard/ LG/ Voltas
Supply and install water heater vertical type having inner shell made of copper & outer shell made of SS including apparatus, thermostat, Glass wool etc of storage capacity 25 litres electric driven complete all as specified and directed.
VRF SYSTEM
SITC. The A/C VRF type outdoor unit with fully DC inverter scroll compressor (Heat pump). The specification are as follows :- The unit shall be suitable cooling or heating mode operation. The unit must have fully DC inverter scroll compressors in each individual module comprising of one/ two variable output DC inverter scroll compressors. Air cooled condensor coil must have anticorrosive treatment.
Air cooled VRF outdoor unit. The unit shall be suitable cooling or heating mode operation. The unit must have fully DC inverter scroll compressors in each individual module comprising of one/ two variable output DC inverter scroll compressor. Air cooled condenser coil must have anticorrosive treatment Outdoor units should be including of following :- MS fabricated stand duly painted, Anti vibration pad, Foundation bolts, anchor fastner and other standard accessories to complete the job. Refrigerant R-410A with first charge of ref. gas. Outdoor unit shall be suitable for 415V + 15% 50C/S, 3 phase AC supply. Make: LG Electronics India Ltd/ Blue star/ Samsung/ Daikin GROUND FLOOR Area-1 (FMIS, Tool crib, looming bay & Kit Marshal Room) 28 HP (Heat Pump) - 01 Nos. Area-2 (Mechanical section) 38HP (Heat pump) - 01 Nos. Area-3 (Electrical & Electronics section)- 38HP (Heat pump) -01 Nos. FIRST FLOOR Area-1 (PE, SPE, Bay-1 & Bay-2) 28HP (Heat pump)- 01Nos. Area-2 (Bay-3 to Bay-5) 24HP (Heat pump)- 01Nos. Area-3 (Bay-6, Bay-7, Ultrasonic Bay & Bay-8) 32HP (Heat pump) - 01 Nos. SECOND FLOOR Area-1 (Tech library & Progress room) 28HP (Heat pump)- 01 Nos. Area-2 (Training room) 28HP (Heat pump)- 01 Nos. Area-3 (EDP room, Material testing and Cafetaria room) 40 HP (Heat pump)- 01Nos. Treated fresh air unit (TFA) 12HP (Heat pump)- 01 Nos. Treated fresh air unit (TFA) 10HP (Heat pump)- 02 Nos.
Ceiling mounted 4 way Cassette Unit (Heating & Cooling) :- SITC of ceiling mounted casette type unit complete of following:- Ground floor (FMIS, Tool crib room, Looming bay & Kit marshal) Cooling capacity 1.5 TR Heating capacity 1.6 TR- 18 Nos. FIRST FLOOR (Bay-3, Bay-4 & Bay-5) Cooling capacity 1.6TR, Heating capacity 1.8TR- 15Nos. Make: LG/ Blue star/ Samsung/ Daikin
All as per item No.74 herein before but in FIRST FLOOR (PE Room, SPE oom, Bay-1 & Bay-2) Cooling Capacity 1.90TR, Heating capacity 2.2 TR - 15 Nos. FIRST FLOOR (Bay-6, Bay-7, Ultrasonic Bay & Bay-8) Cooling capacity 1.8TR, Heating Capacity 2.0 TR- 18Nos. SECOND FLOOR (Training room) Cooling capacity 1.90 TR, Heating capacity 2.2 TR- 15Nos.
All as per item No.74 herein before but in SECOND FLOOR (Tech library & Progress room) cooling capacity 2.0 TR, Heating capacity 2.2TR - 15 Nos.
All as per item No.74 herein before but in Ground floor (Mechanical section) Cooling capacity 2.53 TR, Heating capacity 2.84 TR - 15 Nos. Ground floor (Electrical & Electronics section) Cooling capacity 2.53 TR,Heating capacity 2.84 TR- 15Nos. SECOND FLOOR (EDP, Material testing Cateteria room) Cooling capacity 2.53TR, Heating Capacity 2.84TR, 283 CFM- 18 Nos
Wire remote control :- SITC of wired remote control panels for above mentioned indoor units complete Ground and first floor (All bays) Total 86 Nos. IDU - 17 Nos. Second floor and first floor (All bays and TFA of first floor) Total 48 Nos. IDU- 09 Nos.
Treated fresh air unit : 1700 CFM (Outdoor Application) :- SITC of floor mounted, Side Horizontal discharge, two stage filter treated fresh air unit with rain water protection canopy and Electrical panel of following specification:- Inner and outer skin: 0.8mm thick, Pre plasticised Pre coated Frame :- Extruded aluminium hollow profile. Panel insulation with fibre glass wool of density 48Kg/ Cum and 50mm thick etc and DX cooling coil of 8 RD with filters of 10 micron at 90% efficiency complete to connect with 10 HP ODU cap.- 7.12 TR/ 25.03KW, total coil face area : 3.65 Sqft, Ref R-410A complete Make: Edgetech/ Zeco/ Waves and SA Fan- Kruger/ Nicotra
Treated fresh air unit : 1900 CFM (Outdoor Application) :- SITC of floor mounted, Side Horizontal discharge, two stage filter treated fresh air unit with rain water protection canopy and PLC base Electrical panel of following specification:- Inner and outer skin: 0.8mm thick, Pre plasticised Pre coated Frame :- Extruded aluminium hollow profile. Panel insulation with fibre glass wool of density 48Kg/ Cum and 50mm thick etc and DX cooling coil of 8 RD with filters of 10 micron at 90% efficiency complete to connect with 10 HP ODU cap.- 8.29 TR/ 29.14KW, total coil face area : 4.25 Sqft, Ref R-410A complete - 02 Nos. Make: Edgetech/ Zeco/ Waves and SA Fan- Kruger/ Nicotra AHU KIT, Communication control kit and controller for TFA unit (12HP-1700 CFM- 01 Nos & 12 HP-1900 CFM=02 Nos) Make: LG/ Blue star/ Samsung/ Daikin
SITC of AHU KIT, Communication control kit and controller for TFA unit (12HP-1700 CFM- 01 Nos & 12 HP-1900 CFM=02 Nos) Make: LG/ Blue star/ Samsung/ Daikin
Refrigerant piping :- SITC of Refrigerant piping suitable for R-410A ref. Refrigerant copper piping and tube should be as per JIS H 3300/ ASTM B 280 and inclusive of bends, elbows, reducers, Refnuts, U-bends, oil return and expansion loops, flair nuts/ adopter/ any brass fitting, tee connection with insulation of 19mm thick EPDM rubber tubing complete with pressure testing and supports etc.
Refnuts and accessories for all floors
Additional Ref Gas R-410A
Condensate drain piping :- SITC of condensate drain piping in Unplasticized polyvinyl chloride (UPVC) pipe suitable for UPVC solvent cement jointing with EPDM insulation 9mm thick complete of 40mm dia complete all as directed.
Condensate drain piping :- SITC of condensate drain piping in Unplasticized polyvinyl chloride (UPVC) pipe suitable for UPVC solvent cement jointing with EPDM insulation 9mm thick complete of 32mm dia complete all as directed.
Fresh air duct / pipe :- SITC of fresh air duct/ pipe in UPVC pipe with EPDM insulation of 19mm thick of 300mm dia complete all as directed.
Fresh air duct / pipe :- SITC of fresh air duct/ pipe in UPVC pipe with EPDM insulation of 19mm thick of 250mm dia complete all as directed.
Fresh air duct / pipe :- SITC of fresh air duct/ pipe in UPVC pipe with EPDM insulation of 19mm thick of 200mm dia complete all as directed.
Fresh air duct / pipe :- SITC of fresh air duct/ pipe in UPVC pipe with EPDM insulation of 19mm thick of 150mm dia complete all as directed.
SITC of GSS metal ducts as per IS-277 of 0.80mm thick complete all as specified and directed.
Circular adjustable cone ceiling diffusers should have external cone and adjustable done centre cone and shall have factory fabricated supply air plenium in aluminium construction with inlet and outlet spigot connection complete of 160mm dia for all floor complete all as specified and directed.
Flexible duct connector :- Supply & fix flexible duct connector to fresh air unit with neoprene coated fabric as per NFPA 701 & Class-I of size 500mm x 400mm complete all as specified and directed.
Under deck insulation :- Exposed roof :- SITC Under deck insulation of exposed metallic roofwith 30mm thick aluminium foil face on both side closed cell rigid phenolic foam material of density 65 ± 5Kg/cum complete all as specified and directed. Make: Kingspan
Supply and fix Cable tray (Perforated type) Galvanized for refrigerant piping made of 2.0mm thick, supporting hanger, ties & other standard accessories og size 600mm wide x 50mm ht complete all as specified and directed.
All as per item No.94 herein before but of size 450mm wide x 50mm ht
All as per item No.94 herein before but of size 200mm wide x 50mm ht
Supply, install, testing Electrical MCC panel for VRF air conditioning system with 800 amp copper bus bar, main incoming MCCB 630 Amp TP 36KA & outgoing MCCB of 63/50 Amps - 20 Nos. complete all as specified and directed. Make: Power system & controls/ National/ Universal
SITC isolator for ODU : (Left and right side ODU):- Wall mounted isolator panel having IP-65 protection for outdoor application for 9Nos. Isolator feeders using 63 Amps 4 pole isolator complete all as specified and directed.
Distribution board :- SITC of MCB DB double door type with copper bus bar of following capacity. Ground floor: 6 way TPN DB Incomer-50A/ 4P/MCB/10KA-1No. Outgoing- 25A/30 ma/DP/ELCB-3 Nos. All ELCB in LDB and PDB shall be rated for 100 ma and 300 ma leakage current. All MCB for power DB shall be Curve C
All as per Item No.99 herein before but in First floor: 6 way TPN DB. Incomer:- 20A/4P/MCB/10KA- 1No. Outgoing:- 12A/ 30ma/ DP/ELCB- 3Nos.
All as per Item No.99 herein before but in Second floor: 6 way TPN DB. Incomer:- 16A/4P/MCB/10KA- 1No. Outgoing:- 12A/ 30ma/ DP/ELCB- 3Nos.
All as per Item No.99 herein before but in Ground, first and second floor: 10 way SPN DB, DB-1. Incomer:- 10A/DP/MCB/10KA- 1No. Outgoing:- 4A/ SP/MCB- 10Nos.
Supply and laying of XLPE copper armoured power cable 1100 Volts with suitable dressing material of size 6 Sqmm x 4 Core for main panel to ODU units complete all as specified and directed.
All as per item No.103 herein before but of size 4 Sqmm x 4 Core for main panel to TPN DBs
All as per item No.103 herein before but of size 2.5 Sqmm x 4 Core for TPN DBs to SPN DBs
Supply and laying of flexible copper control cable 1100 Volts with suitable dressing material of size 1.5 Sqmm x 3 core for SPN DBs to indoor cassette units complete all as specified and directed.
Supply and laying of PVC annealed tinned copper shielded cable in PVC conduit pipe with suitable dressing material of sizes 3C x 1.5Sqmm from cassette to cassette looping and connected to ODU and remoted control to IDU & AHU kit to remote control & communication kit etc complete all as specified and directed. Make: ASIAN cable/ CCI/ Polycab
Supply and fix glanding and termination of above said cable with single compression type long head cable gland of brass alongwith solderless crimping type tinned AL/CU lugs for cable of size 3 Core x 10 Sqmm Cu. Complete all as specified and directed.
All as per item No.108 herein before but 3 Core x 6 Sqmm Cu.
All as per item No.108 herein before but 4 Core x 4 Sqmm Cu.
All as per item No.108 herein before but 3 Core x 2.5 Sqmm Cu.
Earthing :- Supply and fix earthing to VRF ODU, TFA etc from nearest earthing source with 12 SWG Cu wire for TFA complete all as specified and directed.
Earthing :- Supply and fix earthing to VRF ODU, TFA etc from nearest earthing source with 25mm x 3mm Cu strip for VRF ODU complete all as specified and directed.
M&L for Earthing complete with copper earth plate electrode of 60 cm x 60 cm x 3 mm thick 2.25m deep below in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of plate not less than 1.5 m below ground level to copper strips of size 20 x 3 mm thick by means of nuts bolt (4 Nos) check nut, riveting washer including welding/brazing of copper strip, all as shown in electrical plate No. 3 connected to test point all as specified or indicated & testing on completion as directed including excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40MM thick reinforced with 6mm dia bar, 3 Nos, 40mm dia light grade GI pipe for protection of strip, and 15mm dia medium grade GI Pipe for water with wire mesh funel and earth work of any strata refilling earth pit with black cotton soil PCC chamber water pipe PCC cover earthing lead from earth test point to panel complete all as specified and directed.
Supply and fix Cable tray (Perforated type) Galvanized for cable fixing made of 1.25mm thick for cable with supporting hanger, ties & other standard accessories of size 300mm wide x 100mm ht complete all as specified and directed.
All as per item No.115 herein before but 200mm wide x 100mm ht
Material and labour for MS fabrication with angles, channels and other accessories to complete the job complete all as directed.
Material and labour for glass reinforced gypsum (GRG) 12mm thick ceiling tiles of 595 x 595mm of having tengular edge fixed with powder coated GI grid in grid of 600 x 600mm complete all as specified and directed. Make: Diamond (brand TM)/ Dexune
EXTERNAL WATER SUPPLY
Cutting the existing GI pipe of size 100mm dia and insert tee 100x100x80mm including making connection as required etc complete all as specified and directed.
Material and labour for construction of brick masonry valve pit/chamber of size, 900 x 900 x 900mm (internal) suitable for 80mm dia sluice valve including necessary excavation and earth work, plain cement concrete 1:4:8, type D-2, using 40mm graded stone aggregates, 150mm thick with 150 mm alround offset from external face of wall, brick work in cement motor 1:6 in walls, rendering 15mm thick in cement motor 1:4, inside complete and outside 150 mm below ground level, coping with plain cement concrete 1:2:4, using 20mm graded stone aggregates, type B-1, 50 mm thick, frame for covers with MS angle iron 50 x 50 x 6 mm sheet cover with 3 mm thick MS sheet brazed with MS flats of size 40 x 6 mm, painting steel surfaces with bituminous paint and covers provided with hinges and handles as required including locking arrangement all as specified and directed.
Material and labour for construction of brick masonry valve pit size 60x60x60cm (internal size of chamber) for gate valve upto 50mm dia, depth of chamber to be reckoned from the top of PCC in foundation to the top of MS cover with and including 3mm thick MS sheet and frame of angle iron 40mmx40mmx 6mm with fixing arrangement, hinges and locking arrangement and two coat of synthetic enamel paint over a coat of red oxide primer on MS cover and frame including necessary excavation and earth work in any type of soil returning filling in approved soil, deposited surplus soil to a distance not exceeding 50 Mtrs, 150mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation, brick work in cement mortar 1:6 and 15mm thick plastering in CM 1:4, 150 mm thick PCC 1:2:4 type B-1 as in copping complete all as specified and directed
EXTERNAL ELECTRIC SUPPLY
Supply, installation, testing and commissioning of indoor type step down transformer of capacity 11000/433 volts (at no load), AC, 3 phase 50Hz capacity 250 KVA core type copper wound, oil immersed, naturally cooled, oil nature, air nature (ONAN) with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector symbol DYN-11 (vector group) with neutral bought out on secondary side (LV side) and having tapping at ±5% HV side to be changed by means of hand operated off load tap changer gear as per IS 1180:2014
The maximum temperature rise should not exceed 45 degree celsius in oil and 55 degree celsius in HV/LV winding when measured by resistance method (Necessary test certificate carried out at factory site to be produced) after continous full load run on an ambient temperature of 40 degree celsius. The transformer shall be IS 2026 marked and shall comprise of the following:- (a) 3 Nos. porcelain bushing with arcing horn on HV side suitable for 11 KV complete with bushing, copper rods, nut and washers (b) One cable box both side on HT/LT side (Primary & Secondary side) consisting of 03Nos & 04 Nos of porcelain insulator simultaneously bushing with copper rods complete with nuts and washers with two Nos cable glands suitable for reception / taking out of XLPE insulated heavy duty armoured cable including glands, jint and jointing material complete (c) Oil conservator with filter type drain valve and oil level gauge (d) De-hydrating breather with first fills dehydrating agent (silica gel) (e) Explosive vent (f) Thermometer pocket on tank cover (g) One No. 100mm dia, dial type thermometer, vapour pressure type having range 0-120 degree celsius with metal guard having maximum perimeter reading temperature indicator with resisting device for transformer (h) Two earthing terminal on tank cover to facilitate fixing of 32x6mm galvanised iron strip for earthing of neutral and body. (j) Including first fill of new and unused transformer oil of dielectric strength 52KV
(k) Shut off valve between the conservator and bucholz relay (l) Ratting and diagram plate (m) Lifting hooks Note: The oil temperature and winding temperature gauges shall be housed on a MS box made out of 16 gauge MS sheet. The MS box made hinged door and having glass 3mm thick front of the box provision for entry of cables and compression glands.
Supply, installation, testing and commissioning of indoor type step down transformer of capacity 11000/433 volts (at no load), AC, 3 phase 50Hz capacity 500 KVA core type copper wound, oil immersed, naturally cooled, oil nature, air nature (ONAN) with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector symbol DYN-11 (vector group) with neutral bought out on secondary side (LV side) and having tapping at ±5% HV side to be changed by means of hand operated off load tap changer gear as per IS 1180:2014
The maximum temperature rise should not exceed 45 degree celsius in oil and 55 degree celsius in HV/LV winding when measured by resistance method (Necessary test certificate carried out at factory site to be produced) after continous full load run on an ambient temperature of 40 degree celsius. The transformer shall be IS 2026 marked and shall comprise of the following:- (a) 3 Nos. porcelain bushing with arcing horn on HV side suitable for 11 KV complete with bushing, copper rods, nut and washers (b) One cable box both side on HT/LT side (Primary & Secondary side) consisting of 03Nos & 04 Nos of porcelain insulator simultaneously bushing with copper rods complete with nuts and washers with two Nos cable glands suitable for reception / taking out of XLPE insulated heavy duty armoured cable including glands, jint and jointing material complete (c) Oil conservator with filter type drain valve and oil level gauge (d) De-hydrating breather with first fills dehydrating agent (silica gel) (e) Explosive vent (f) Thermometer pocket on tank cover (g) One No. 100mm dia, dial type thermometer, vapour pressure type having range 0-120 degree celsius with metal guard having maximum perimeter reading temperature indicator with resisting device for transformer (h) Two earthing terminal on tank cover to facilitate fixing of 32x6mm galvanised iron strip for earthing of neutral and body. (j) Including first fill of new and unused transformer oil of dielectric strength 52KV
(k) Shut off valve between the conservator and bucholz relay (l) Ratting and diagram plate (m) Lifting hooks Note: The oil temperature and winding temperature gauges shall be housed on a MS box made out of 16 gauge MS sheet. The MS box made hinged door and having glass 3mm thick front of the box provision for entry of cables and compression glands.
Supply, installation, testing and commissioning of indoor type step down transformer of capacity 11000/433 volts (at no load), AC, 3 phase 50Hz capacity 630 KVA core type copper wound, oil immersed, naturally cooled, oil nature, air nature (ONAN) with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector symbol DYN-11 (vector group) with neutral bought out on secondary side (LV side) and having tapping at ±5% HV side to be changed by means of hand operated off load tap changer gear as per IS 1180:2014
The maximum temperature rise should not exceed 45 degree celsius in oil and 55 degree celsius in HV/LV winding when measured by resistance method (Necessary test certificate carried out at factory site to be produced) after continous full load run on an ambient temperature of 40 degree celsius. The transformer shall be IS 2026 marked and shall comprise of the following:- (a) 3 Nos. porcelain bushing with arcing horn on HV side suitable for 11 KV complete with bushing, copper rods, nut and washers (b) One cable box both side on HT/LT side (Primary & Secondary side) consisting of 03Nos & 04 Nos of porcelain insulator simultaneously bushing with copper rods complete with nuts and washers with two Nos cable glands suitable for reception / taking out of XLPE insulated heavy duty armoured cable including glands, jint and jointing material complete (c) Oil conservator with filter type drain valve and oil level gauge (d) De-hydrating breather with first fills dehydrating agent (silica gel) (e) Explosive vent (f) Thermometer pocket on tank cover (g) One No. 100mm dia, dial type thermometer, vapour pressure type having range 0-120 degree celsius with metal guard having maximum perimeter reading temperature indicator with resisting device for transformer (h) Two earthing terminal on tank cover to facilitate fixing of 32x6mm galvanised iron strip for earthing of neutral and body. (j) Including first fill of new and unused transformer oil of dielectric strength 52KV
(k) Shut off valve between the conservator and bucholz relay (l) Ratting and diagram plate (m) Lifting hooks Note: The oil temperature and winding temperature gauges shall be housed on a MS box made out of 16 gauge MS sheet. The MS box made hinged door and having glass 3mm thick front of the box provision for entry of cables and compression glands.
Material and labour for Servo Voltage stabilizer copper wound for AUTOMATIC operation three phase unbalanced type naturally oil cooled (ONAM) indoor type & designed for input variation between 300V to 480V with output voltage stabilized for automatic operation three phase naturally oil cooled (ONAM) indoor type and deigned for input variationbetween 300V to 480V with output voltage stabilised at 415V with accuracy of ±1% and speed correction shall not be less than 8 Volts per second and capacity of 250KVA as per IS 9815/ IS 2026.
Material and labour for Servo Voltage stabilizer copper wound for AUTOMATIC operation three phase unbalanced type naturally oil cooled (ONAM) indoor type & designed for input variation between 300V to 480V with output voltage stabilized for automatic operation three phase naturally oil cooled (ONAM) indoor type and deigned for input variationbetween 300V to 480V with output voltage stabilised at 415V with accuracy of ±1% and speed correction shall not be less than 8 Volts per second and capacity of 500KVA as per IS 9815/ IS 2026.
Material and labour for Servo Voltage stabilizer copper wound for AUTOMATIC operation three phase unbalanced type naturally oil cooled (ONAM) indoor type & designed for input variation between 300V to 480V with output voltage stabilized for automatic operation three phase naturally oil cooled (ONAM) indoor type and deigned for input variationbetween 300V to 480V with output voltage stabilised at 415V with accuracy of ±1% and speed correction shall not be less than 8 Volts per second and capacity of 1000KVA as per IS 9815/ IS 2026.
Supply & installation of 11KV indoor extensible 04 way ring main unit floor mounted with copper bus bars having raychem sleeved, consisting of 01 No. incoming 630A fixed vacuum circuit breakers & 03 Nos. outgoing motorised and manually operated vacuum circuit breaker & 01 No. air insulated BUS PT panel coupled with RMU. All live parts, bus bars, VCBs connections of RMU should be enclosed in one tank to avoid multiple interconnections & sealed for life robotically welded stainless steel tank 3mm thick having IP 67 degree of protection filled with gas as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200. RMU should complete with all accessories such as ring core CTs, self powered microprocessor based numerical protection relay for O/C, S/C and E/F, cable supports, all front cable terminations, mechanical indications for breaker ON/OFF/ Trip/ Spring charges, Manometer as per with
IEC standards 62271-200, 60056, 60129, 60298, 60420, 60529 and 60694. Altitude of Installation up to 1000m as per IEC 60120. Bushings bolted type top mounted outside the tank for connection of external busbar: Each vacuum circuit breaker module should consist of following accessories:- 630A Vacuum circuit breaker module for making and breaking of fault current alongwith off-load isolator in series for isolation purpose & integral series earth switch of full making capacity Short time current- 21KA/3sec Making capacity- 52.5KA Auxiliary contact - 1No + 1NC Maximum width - 340mm for compact design Maximum depth - 900mm for compact design Power frequency withstand voltage - 28KV Impulse withstand voltage - 95KV Nominal operating gas pressure - 1.4 Bar abs. Front cover mechanism - IP2X Cable cover - 4X Internal arc type tested 24V DC motorised spring charging mechanism for breaker operation Push buttons for breaker ON/OFF Cable box for front termination of the cable suitable upto 3 core 300Sqmm, 11KV XLPE Cable Right angle boots(push on type) battery 12Volt 180AH- 02Nos Make: Schneider/ Siemens/ ABB
Self powered microprocessor based relay 3O/C + 1E/F with low and high set for over current and earth fault. Relay should have facility to display the maximum loaded phase current also. Relay should be flush mounted having facility to trip the breaker from remote commands without shunt trip coil alongwith HMI screen interface Panel mounted 11KV Ring core CTs 5P10 for protection as per IEC 60185 Panel mounted 11KV ring core CTs Class 1.0 for metering as per IEC 60185 LV compartment mounted on top consisting of Digital multifunction meter (A, V, KW, KVA, F, PF) type Rishabh RISH 3430/ Conserve EM6400 Indicating lamps Suitable cable bushings for front only cable terminations Arc proof cable covers with self interlocking mechanism with earth switch Capacitive voltage indication fixed type system as per IEC 61243 Mechanical Indications for breaker ON, OFF, EARTH, TRIP, Spring charged- Discharged Air insulated Bus PT module 3 Nos Potential transformer of the ratio 11KV/√3/110V/√3 Class 1.0 with HT fuses on primary side and MCB on secondary side CFL for illumination Bushings bolted type top mounted outside the module for connection of external busbar
Supply & Installation of 11KV outdoor extensible 03 way ring main unit floor mounted with copper bus bars having raychem sleeved, consisting of 01 No incoming 630A motorised and manually operated vacuum circuit breakers & 02 Nos outgoing fixed vacuum circuit breaker & 01No. Air insulated BUS PT panel coupled with RMU. All live parts, bus bars, VCBs connections of RMU should be enclosed in one tank to avoid multiple interconnections & sealed for life robotically welded stainless steel tank 3mm thick having IP67 degree of protection filled with gas as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200.
RMU should complete with all accessories such as ring core CTs, self powered micro processor based numerical protection relay for O/C, S/C and E/F, cable supports, all front cable terminations, mechanical indications for breaker ON/OFF/Trip/Spring charged, Manometer as per IEC standards 62271-200, 60056, 60129, 60265, 60298, 60420, 60529 and 60694. Altitude of installation upto 1000m as per IEC 60120. Bushings bolted type top mounted outside the tank for connection of external busbar. Each Vacuum circuit breaker module should consist of following accessories: 630A Vacuum circuit breaker module for making and breaking of fault current alongwith off-load isolator in series for isolation purpose & integral series earth switch of full making capacity Short time current- 21KA/ 3sec Making capacity - 52.5KA Auxiliary contacts - 1No + 1NC Maximum width - 340mm for compact design Maximum depth - 900mm for compact design Power frequency withstand voltage - 28KV Impulse withstand voltage - 95KV Nominal operating gas pressure - 1.4 Bar abs. Front cover mechanism - IP2X
Cable covers - 4X Internal arc type tested 24V DC motorised spring charging mechanism for breaker operation Push buttons for breaker ON/OFF Cable box for front termination of the cable suitable upto 3 core 300 Sqmm 11KV XLPE Cable Right angle boots(push on type) Make: Schneider/ Siemens/ ABB Self powered microprocessor based relay 3O/C + 1E/F with low and high set for over current and earth fault. Relay should have facility to display the maximum loaded phase current also. Relay should be flush mounted having facility to trip the breaker from remote commands without shunt trip coil alongwith HMI screen interface Panel mounted 11KV Ring core CTs 5P10 for protection as per IEC 60185 Panel mounted 11KV ring core CTs Class 1.0 for metering as per IEC 60185 LV compartment mounted on top consisting of Digital multifunction meter (A, V, KW, KVA, F, PF) type Rishabh RISH 3430/ Conserve EM6400 Indicating lamps Suitable cable bushings for front only cable terminations Arc proof cable covers with self interlocking mechanism with earth switch Capacitive voltage indication fixed type system as per IEC 61243 Mechanical Indications for breaker ON, OFF, EARTH, TRIP, Spring charged- Discharged Air insulated Bus PT module
Supplying, installation, testing & commissioning of HT 12 KV, 3 Phase 50 Hz totally metal clad withdraw able type Vacuum Circuit Breaker panel indoor type with aluminum bus bar of suitable rating, horizontal isolation type VCB of capacity minimum 630 Amps rated current as per latest IEC 62271-200. Switch gear panel shall be of sheet steel construction with Aluminum zinc not less than 2.5 mm thickness for load bearing section and not less than 2mm thick for non load bearing shall be totally dust and vermin proof. The offered panels shall be tested for IAC level of 25 KA, No of operation of Vacuum Interrupter Bottles (ABB/Siemens/Schneider only) for better performance : (i) Mechanical life 30,000 operations, (ii) Rated current 10,000A & (iii) Rated short circuit current 100A.
(A) All the main components like VI/VCB/Relays/Meters shall be of same make. Approved makes : ABB (ZNS2)/Siemens (NX-Air)/Schneider (PIX). Panel and VCB parameters are as below. (i) Rated voltage level/PF withstand voltage/Impulse level: 12KV/28KV/75KVp. (ii) Continous current rating : minimum 400A. (iii) Short circuit withstand current : minimum 25 KZ for 3 Sec. (iv) One No. minimum 400 Apms horizontal draw out type vacuum circuit breaker in 12KV metal clad floor mounting panel complete with following :- (a) Manually and motor operated (230V,AC,50Hz) spring charged type, manually and electrically open (electrical-110 VDC) Operation type, incorporating mechanical as well as electrical ON/OFF indication "OFF" push button, test/service position limit switches, with minimum 6No+6NC breaker auxiliary contacts in service position. (b) Epoxy cast wound current tranformer (CT), 12KV of ratio 100-50/1+1A, 5P10/1.0, 15 VA burden with metering and protection core including necessary control wiring. (B) Protection arrangement for the breaker shall comprise of the following :- (i) E/F, O/C TCS with IEC 103 protocal for communication & draw out type-numerical type Siemens (7SJ62)/ARB (REF 615)/Schneider (P-122). (ii) Complete with master trip/Anti pumping relay. All the relay shall belong to common platform and shall be of single make with electromechanical relays in draw out casing.
Supply, Install, test and commissioning of HT 11KV 3 Phase 50 Hz, totally metal clad withdrawable type Vacuum circuit breaker panel Indoor type with aluminium busbar of suitable rating, horizontal isolation type VCB of capacity 350MVA, horizontal isolation type VCB of capacity minimum 630 Amps rated current as per latest IEC 62271-200 Make: ABB (ZNS2)/ Siemens (NX-Air)/ Schneider (Pix)
Switch gear panel shall be of sheet steel construction with Aluminium zinc not less than 2.5mm thickness for load bearing section and not less than 2mm thick for non load bearing shall be totally dust and vermin proof. The offered panels shall be tested for IAC level of 25KA, No. of operation of Vacuum interrupter bottles (ABB/ Siemens/ Schneider) for better performance : (i) Mechanical life - 30000 operations (ii) Rated current - 10,000A & (iii) Rated shot circuit current - 100A (A) All the main components like VI/ VCB/ Relays/ Meters shall be of same make. Panel and VCB Parameter are as below:- (i) Rated voltage level/ PF withstand voltage/ Impulse level: 12KV/ 28KV/75KVp
(ii) Continous current rating : Minimum 400A (iii) Short circuit withstand current : minimum 25KA for 1 sec. (iv) One No. minimum 400 Amps horizontal drawout type vacuum circuit breaker in 12KV metal clad floor mounting panel complete with following:- (a) Manually and motor operated (230V, AC, 50Hz) spring charged type, manually and electrically operated (electrical-110 VDC) operation type, incorporated mechanical as well as electrical ON/OFF indication 'OFF' push button, test/ service position limit switches, with minimum 6No. + 6NC breaker auxiliary contacts in service position. (b) Epoxy cast wound current transformer (CT), 12KV of ratio 100-50/1+1A, 5P10/1.0, 15 VA burden with metering and protection core including necessary control wiring.
BLANK
BLANK
Supply & Laying bricks using sub class ‘B’ bricks (old size) for cable protection laid flat and dry in trenches over cable perpendicular to direction of cable complete all as specified and directed
Supply, install, testing and commissioning of factory made feeder pillar box 3mm thick outer CRCA sheet LT distribution switch gear and control gear, floor mounted, totally enclosed, cubicle type modular compartment, dust and vermin proof with neoprene gasket, inner sheet fabricated out of CRCA sheet of thickness not less than 2mm complete with two bus bar chamber having openable front and rear shutters with suitable locking arrangement of shutters, duly powder coated shade No RAL 7032 after washing with RR-10 chemical for rust proofing including PCC 1:2:4 type B-1 using 20mm graded stone aggregate foundation raised base complete all as specified and directed including the following component :-
Supply, install, testing and commissioning of factory made feeder pillar box 3mm thick outer CRCA sheet indoor type LT distribution switch gear and control gear, floor mounted, totally enclosed, cubicle type modular compartment, dust and vermin proof with neoprene gasket, inner sheet fabricated out of CRCA sheet of thickness not less than 2mm complete with two bus bar chamber having openable front and rear shutters with suitable locking arrangement of shutters, duly powder coated shade No RAL 7032 after washing with RR-10 chemical for rust proofing including PCC 1:2:4 type B-1 using 20mm graded stone aggregate foundation raised base complete all as specified and directed including the following component :-
Supply, install, testing and commissioning of factory made LT panel board indoor type LT distribution switch gear and control gear, floor mounted, totally enclosed, cubicle type modular compartment, dust and vermin proof with neoprene gasket, fabricated out of CRCA sheet of thickness not less than 2mm complete with two bus bar chamber having openable front and rear shutters with suitable locking arrangement of shutters, duly powder coated shade No RAL 7032 after washing with RR-10 chemical for rust proofing including PCC 1:2:4 type B-1 using 20mm graded stone aggregate foundation raised base complete all as specified and directed including the following component :-
Outgoing (i) MCCB 3 pole with adjustable thermal and adjustable magnetic setting of rating 160Amps 36KA -02 Nos. (ii) MCCB 3 pole with adjustable thermal and adjustable magnetic setting of rating 250Amps 36KA -02 Nos. (iii) MCCB 3 pole with adjustable thermal and adjustable magnetic setting of rating 63Amps 25KA -04 Nos. (iv) Spare for housing MCCB - 01 No (v) Cable alleys (vi) Cable glands to adopt incoming and outgoing cables
Supply, install, testing and commissioning of 175Kvar Automatic power factor improvement system of 3 phase 415V, 50Hz, floor mounted, modular design structure, Non- compartmentalized, dust and vermin proof, made out of 3.15mm M.S sheet and M.S angle iron 40x40x6mm frame, duly powder coated, front & back openable with locking arrangement to facilitate easy maintenance, heavy cable entry gland provision, hooks on top for mounting panel in platform complete capacitor and reactor filter assembly should be mounted on the rack through nut & bolts so that it can be taken out from the panel during the maintenance/ replacement. Necessary internal connection with proper copper wire rating & lugs. Proper control wiring with protection to relay, fans and Thyristor module comprises of following :-
AXIAL FLOW FAN with thermostat on the top with MCB protection BUS-BARS - 400 Amps TP copper bus bars SMPS POWER SUPPLY : 24V, 9A SMPS power supply for TSM firing with protection on incoming and outgoing INCOMER : 400 Amps TP, MCCB, Thermal magnetic, adjustable with O/L & S/C protection, 100% Ics=Icu, 36KA Make: L&T/ GE/ Legrand/ ABB OUTGOING (BANK PROTECTION) HRC fuse link with fuse base : Bank - I- 3Nos of 12A HRC fuse link in 32A fuse base Bank - II- 3Nos of 25A HRC fuse link in 32A fuse base Bank - III- 3Nos of 25A HRC fuse link in 32A fuse base Bank - IV- 3Nos of 40A HRC fuse link in 63A fuse base Bank - V- 3Nos of 50A HRC fuse link in 63A fuse base Bank - VI- 3Nos of 50A HRC fuse link in 63A fuse base Bank - VII- 3Nos of 50A HRC fuse link in 63A fuse base Bank - VIII- 3Nos of 100A HRC fuse link in 125A fuse base Make: L&T/ GE/ SIEMENS/ ABB
Glass fuse links 2A, with base for Thyristor module protection Make: Connect well/ FTC/ Pheonix THYRISTOR MODULE - Electronic thyristor switching module (Not SSR- solid state relay) should be capable of Voltage peak withstand capacity of upto 2200 V PIV. They should be installed in separate enclosure with heat sink, firing card and axial fan for its cooling operation Bank - I - 1No. of 15 Kvar Bank - II - 1No. of 15 Kvar Bank - III - 1No. of 20 Kvar Bank - IV - 1No. of 25 Kvar Bank - V - 1No. of 25 Kvar Bank - VI - 1No. of 25 Kvar Bank - VII - 1No. of 25 Kvar Bank - VIII - 1No. of 25 Kvar Make: L&T/ GE/ Neptune/ Epcos CAPACITORS : Capacitor should be super heavy duty (MDXL) with 525V, 50Hz capable of withstanding current upto 4xln and temperature withstanding upto 70 deg C temperature on its surface without any detoriation in its lifespan
Bank - I - 1No. of 15 Kvar Bank - II - 1No. of 15 Kvar Bank - III - 1No. of 20 Kvar Bank - IV - 1No. of 25 Kvar Bank - V - 1No. of 25 Kvar Bank - VI - 1No. of 25 Kvar Bank - VII - 1No. of 25 Kvar Bank - VIII - 1No. of 25 Kvar Make: L&T/ GE/ Neptune- Ducati
Supply, install, testing and commissioning of 225Kvar Automatic power factor improvement system of 3 phase 415V, 50Hz, floor mounted, modular design structure, Non- compartmentalized, dust and vermin proof, made out of 3.15mm M.S sheet and M.S angle iron 40x40x6mm frame, duly powder coated, front & back openable with locking arrangement to facilitate easy maintenance, heavy cable entry gland provision, hooks on top for mounting panel in platform complete capacitor and reactor filter assembly should be mounted on the rack through nut & bolts so that it can be taken out from the panel during the maintenance/ replacement. Necessary internal connection with proper copper wire rating & lugs. Proper control wiring with protection to relay, fans and Thyristor module comprises of following :-
AXIAL FLOW FAN with thermostat on the top with MCB protection BUS-BARS - 400 Amps TP copper bus bars SMPS POWER SUPPLY : 24V, 9A SMPS power supply for TSM firing with protection on incoming and outgoing INCOMER : 400 Amps TP, MCCB, Thermal magnetic, adjustable with O/L & S/C protection, 100% Ics=Icu, 36KA Make: L&T/ GE/ Legrand/ ABB OUTGOING (BANK PROTECTION) HRC fuse link with fuse base : Bank - I- 3Nos of 12A HRC fuse link in 32A fuse base Bank - II- 3Nos of 25A HRC fuse link in 32A fuse base Bank - III- 3Nos of 25A HRC fuse link in 32A fuse base Bank - IV- 3Nos of 40A HRC fuse link in 63A fuse base Bank - V- 3Nos of 50A HRC fuse link in 63A fuse base Bank - VI- 3Nos of 50A HRC fuse link in 63A fuse base Bank - VII- 3Nos of 50A HRC fuse link in 63A fuse base Bank - VIII- 3Nos of 100A HRC fuse link in 125A fuse base Make: L&T/ GE/ SIEMENS/ ABB
Glass fuse links 2A, with base for Thyristor module protection Make: Connect well/ FTC/ Pheonix THYRISTOR MODULE - Electronic thyristor switching module (Not SSR- solid state relay) should be capable of Voltage peak withstand capacity of upto 2200 V PIV. They should be installed in separate enclosure with heat sink, firing card and axial fan for its cooling operation Bank - I - 2No. of 15 Kvar Bank - II - 2No. of 15 Kvar Bank - III - 2No. of 20 Kvar Bank - IV - 1No. of 25 Kvar Bank - V - 1No. of 25 Kvar Bank - VI - 1No. of 25 Kvar Bank - VII - 1No. of 25 Kvar Bank - VIII - 1No. of 25 Kvar Make: L&T/ GE/ Neptune/ Epcos CAPACITORS : Capacitor should be super heavy duty (MDXL) with 525V, 50Hz capable of withstanding current upto 4xln and temperature withstanding upto 70 deg C temperature on its surface without any detoriation in its lifespan
Bank - I - 2No. of 15 Kvar Bank - II - 2No. of 15 Kvar Bank - III - 2No. of 20 Kvar Bank - IV - 1No. of 25 Kvar Bank - V - 1No. of 25 Kvar Bank - VI - 1No. of 25 Kvar Bank - VII - 1No. of 25 Kvar Bank - VIII - 1No. of 25 Kvar Make: L&T/ GE/ Neptune- Ducati
Supply, install, testing and commissioning of 100Kvar Automatic power factor improvement system of 3 phase 415V, 50Hz, floor mounted, modular design structure, Non- compartmentalized, dust and vermin proof, made out of 3.15mm M.S sheet and M.S angle iron 40x40x6mm frame, duly powder coated, front & back openable with locking arrangement to facilitate easy maintenance, heavy cable entry gland provision, hooks on top for mounting panel in platform complete capacitor and reactor filter assembly should be mounted on the rack through nut & bolts so that it can be taken out from the panel during the maintenance/ replacement. Necessary internal connection with proper copper wire rating & lugs. Proper control wiring with protection to relay, fans and Thyristor module comprises of following :-
AXIAL FLOW FAN with thermostat on the top with MCB protection BUS-BARS - 400 Amps TP copper bus bars SMPS POWER SUPPLY : 24V, 9A SMPS power supply for TSM firing with protection on incoming and outgoing INCOMER : 400 Amps TP, MCCB, Thermal magnetic, adjustable with O/L & S/C protection, 100% Ics=Icu, 36KA Make: L&T/ GE/ Legrand/ ABB OUTGOING (BANK PROTECTION) HRC fuse link with fuse base : Bank - I- 3Nos of 12A HRC fuse link in 32A fuse base Bank - II- 3Nos of 25A HRC fuse link in 32A fuse base Bank - III- 3Nos of 25A HRC fuse link in 32A fuse base Bank - IV- 3Nos of 40A HRC fuse link in 63A fuse base Bank - V- 3Nos of 50A HRC fuse link in 63A fuse base Make: L&T/ GE/ SIEMENS/ ABB
Glass fuse links 2A, with base for Thyristor module protection Make: Connect well/ FTC/ Pheonix THYRISTOR MODULE - Electronic thyristor switching module (Not SSR- solid state relay) should be capable of Voltage peak withstand capacity of upto 2200 V PIV. They should be installed in separate enclosure with heat sink, firing card and axial fan for its cooling operation Bank - I - 1No. of 15 Kvar Bank - II - 1No. of 15 Kvar Bank - III - 1No. of 20 Kvar Bank - IV - 1No. of 25 Kvar Bank - V - 1No. of 25 Kvar Make: L&T/ GE/ Neptune/ Epcos CAPACITORS : Capacitor should be super heavy duty (MDXL) with 525V, 50Hz capable of withstanding current upto 4xln and temperature withstanding upto 70 deg C temperature on its surface without any detoriation in its lifespan
Bank - I - 1No. of 15 Kvar Bank - II - 1No. of 15 Kvar Bank - III - 1No. of 20 Kvar Bank - IV - 1No. of 25 Kvar Bank - V - 1No. of 25 Kvar Make: L&T/ GE/ Neptune- Ducati
Supply, install, testing and commissioning of factory made LT panel board indoor type LT distribution switch gear and control gear, floor mounted, totally enclosed, cubicle type modular compartment, dust and vermin proof with neoprene gasket, fabricated out of CRCA sheet of thickness not less than 2mm complete with two bus bar chamber having openable front and rear shutters with suitable locking arrangement of shutters, duly powder coated shade No RAL 7032 after washing with RR-10 chemical for rust proofing including PCC 1:2:4 type B-1 using 20mm graded stone aggregate foundation raised base complete all as specified and directed including the following component :-
Outgoing (i) MCCB 4 pole with adjustable thermal and adjustable magnetic setting of rating 250Amps 36KA -03 Nos. (ii) MCCB 3 pole with adjustable thermal and adjustable magnetic setting of rating 160Amps 25KA -04 Nos. (iii) Spare for housing MCCB (iv) Cable alleys (v) Cable glands to adopt incoming and outgoing cables
Supply, install, testing and commissioning of factory made LT panel board indoor type LT distribution switch gear and control gear, floor mounted, totally enclosed, cubicle type modular compartment, dust and vermin proof with neoprene gasket, fabricated out of CRCA sheet of thickness not less than 2mm complete with two bus bar chamber having openable front and rear shutters with suitable locking arrangement of shutters, duly powder coated shade No RAL 7032 after washing with RR-10 chemical for rust proofing including PCC 1:2:4 type B-1 using 20mm graded stone aggregate foundation raised base complete all as specified and directed including the following component :-
Outgoing (i) MCCB 3 pole with adjustable thermal and adjustable magnetic setting of rating 160Amps 25KA -02 Nos. (ii) MCCB 3 pole with adjustable thermal and adjustable magnetic setting of rating 100Amps 25KA -02 Nos. (iii) MCCB 4 pole with adjustable thermal and adjustable magnetic setting of rating 63Amps 25KA -01 Nos. (iv) Spare for housing MCCB (v) Cable alleys (vi) Cable glands to adopt incoming and outgoing cables Make: Legrand/ Havells/ ABB
Supply, install, testing and commissioning of factory made LT panel board indoor type LT distribution switch gear and control gear, floor mounted, totally enclosed, cubicle type modular compartment, dust and vermin proof with neoprene gasket, fabricated out of CRCA sheet of thickness not less than 2mm complete with two bus bar chamber having openable front and rear shutters with suitable locking arrangement of shutters, duly powder coated shade No RAL 7032 after washing with RR-10 chemical for rust proofing including PCC 1:2:4 type B-1 using 20mm graded stone aggregate foundation raised base complete all as specified and directed including the following component :-
Outgoing (i) MCCB 3 pole with adjustable thermal and adjustable magnetic setting of rating 160Amps 25KA -01 Nos. (ii) MCCB 4 pole with adjustable thermal and adjustable magnetic setting of rating 63Amps 25KA -03 Nos. (iii) Spare for housing MCCB (iv) Cable alleys (v) Cable glands to adopt incoming and outgoing cables (vi) MCB SPN 32Amps 03Nos.
Material and labour for bore earthing 150mm dia burried by vertical boring machine, depth 50metre below ground level using earth electrode 50mm dia GI pipe medium grade duly drilled hole of 12mm dia, 15cm c/c on both side of the pipe including lowering in bore well upto the depth of 49 metre and one metre above the ground level.
The pipe electrode should be filled around commercial salt charcoal dust, copper sulphate and magnesium phosphate of 30cm layer each upto the full length of pipe. The borewell should have 12metre of length 150mm dia MS pipe for protection of bore well. Welding of GI strip 50x6mm on earth electrode GI pipe 50mm dia upto the 10m below ground level and 15m from the bore well to test point and PCC foundation surrounding the borewell 60x60x30cm complete all as specified and directed. Note: GI strip more than 25m will be measured and paid separately.
Supply, install, testing and commissioning of factory made feeder pillar box 3mm thick outer CRCA sheet LT distribution switch gear and control gear, floor mounted, totally enclosed, cubicle type modular compartment, dust and vermin proof with neoprene gasket, inner sheet fabricated out of CRCA sheet of thickness not less than 2mm complete with two bus bar chamber having openable front and rear shutters with suitable locking arrangement of shutters, duly powder coated shade No RAL 7032 after washing with RR-10 chemical for rust proofing including PCC 1:2:4 type B-1 using 20mm graded stone aggregate foundation raised base complete all as specified and directed including the following component :-
Boring of holes under road pavement, hardstanding by trenchless technology using ultrasound technique and necessary machine including HDPE pipe of 150mm dia suitable for 0.4 MPa working pressure complete all as specified and directed.
Supply and fix UPS for 30 min back up single phase AC input 160 to 260 V and output 230 ± 1% of capacity 3KVA complete all as specified and directed.
Material and labour for HT feeder piller box outdoor type suitable for 11000 Volt grade with CPRI approved of size 200x200x150 cm of factory made totally enclosed weather proof with duly epoxy powder two coated made out of 3mm thick MS sheet with front and rear openable doorand both side locking arrangement and 03 Nos of copper bus bar 630 Amps rating capacity including 8mm acrylic sheet
on both side rear and front side with SMC insulator support duly fixed on box with drilling of suitable size of hole in bus bar, fixed with suitable size of nuts, bolts, washer including danger notice board complete fitted on angle iron frame of size 50x50x6mm and 75cm height (45cm below ground level and 30cm above ground level) and grouted in PCC 1:3:6 type C-2 using 20mm graded stone aggregate platform complete including 2.0 metre height fencing including 3x3metre for all side with angle iron frame and GI wire mesh and gate complete work all as specified and directed.
Supply and fixing Energy saving street light fitting of 90W capacity high pressure die cast aluminiumhousing with seal toughened glass cover, light source should be multi LED SMD array with individual secondary lenses color temperature 6000K ± 500K, system efficiency should be minimum 100 Lumen/ watt and minimum system lumen package of 9000 lumens complete all as specified and directed. Make: CG/ Phillips/ Havells
Supplying, transporting, erection, testing and commissioning of raising/ lowering type high mast lighting system 12.5 metre high with all accessories comprising of following :- (a) Mast shaft in two section hot and dip galvanized and suitable for wind velocity 180 Km/ hrs IS 875 Part 3
(b) Head frame double drum winch, steel wire rope of minimum 6mm dia (c) Galvanized lantern carriage arrangement suitable for 8 Nos. lantern symetrically fitted LED luminaire of 150 watts - 8Nos. (d) Supply and fix 8 Nos. lantern symetrically fitted LED luminaire of 150 watts (e) Integral power tool on installed inside base compartment for its operation control panel housing control circuit for the operation of the mast and required control for the power tool motor (f) Design, supply and casting of suitable shallow foundation with M-20 concrete for the high mast considering safe soil bearing capacity at the site and as per manufacturer design. (g) Anchor plates templates and foundation bolts manufactured from special steel along with nuts washers anchor plate and templates (h) Supply and fix LED aviation obstruction light comprising of aluminium housing with polycarbonate enclosure. Model No. BGAV302 LED of Bajaj or equivalent in specified makes. (j) Lighting final (lighting arrestor ) electrical control panel, housing with suitable control circuit and wiring for the operation of the mast.
(k) Supply, installing, testing and commissioning factory made feeder pillar outdoor type platform mount suitable for 415 Volts 3 phase 4 wire 50 Hz AC supply system having bus bar chamber duly with insulated with heat shrinkable colored sleeves aluminium bus bar of rating 200 Amps installed on epoxy type insulator. The panel shall be dust and vermin proof IP 54 class protection and made out of CRCA sheet thickness not less than 3mm and 50x50x5mm thick angle iron frame work powder coated finish, both side opening type with aprons for cable entry with double door shutter and locking arrangement, including internal wiring the PVC insulated stranded copper conductor FRLS cable of ISI maked suitable size but not less than 2.5 Sqmm and consisting the following :- Incoming :- MCCB 4 pole 415 Volts 63 Amps and rupturing capacity 25KA with thermal magnetic released complete - 01 No. Outgoing (i) Digital voltmeter 0-500 Volts - 01No. (ii) Ammeter 0-100 Amps digital type with slector switch - 01 No. (iii) Timer switch with suitable size of contactor - 01 Set (iv) Indication lamp LED type (set of three) - 01 Set (v) Starter for suitable size for power tool
FIRE DETECTION SYSTEMS
Supply, installation, testing & commissioning of UL listed, 9th edition 32 bit Fire alarm control panel having microprocessor based 5 loop cards expandable upto 8 loops with 252 intelligent points per loop cards in any flexible combination (detectors or devices ).
The panel shall have the capacity of storing upto 5000 events. Further, the panel must be able to automatically switch ON /OFF respective control module when ever any alarm is triggered. The panel have 6 inch long LCD touch screen and LED's for displaying system status. In addition to the digital screen, the user can view a graphics map which can show a simple building floor plan. The panel shall provide the user with 40 programmable macro or function buttons, which can be programmed for a variety of usages like controlling AHU's, Pressurisation fans, fire pumps, monitoring of flow switches in fire pipe line etc. The panel shall have a built in power supply of 170 Watts and battery charger. Battery charger shall be able to charge the system batteries upto 100 AH. The panel shall have 240 V AC power supply, 24 V SMF batteries sufficient for 24 hour in standby and 30 minutes in alarm complet as per specification. The Panel shall have the capacity of connecting additional 15 panels or Network terminals using network card. The panel shall have the capacity of connecting maximum 8 Remote terminals or 8 remote displays using RS 485 card. Bacnet/Modbus interface card for BMS integration. Makes: (JCI/Hochiki/Siemens/Feuerx)
Supply, installation, testing and commissioning of UL listed and FM approved repeater panel with minimum 160 characters backlit LCD display & with event and audiable status LED's, scroll buttons to view additional events, local sounder and provided in its own enclosure complete all as specified and directed. Make: JCI/ Hochiki/ Siemens/ Feuerx
Supply, installation, testing and commisioning of UL listed and FM approved intelligent addressable multi-criteria detector with fire print technology having responsiveness of photoelectric, thermal and false alarm resistance along with standard base. Multi-criteria detector shall be an intelligent digital photoelectric detector with a programmable heat detector. The detector shall have 11 sensitivity level and with bi color LED, Green for Normal, Amber/ yellow for trouble and red for alarm shall be polarity insensitive and facility to mount in different comprehensive environment like hostile environment, parking garage, HVAC ducts, precious storage, transformer rooms, ware house, dormitory and normal working environments complete all as specified and directed. Make: JCI/ Hochiki/ Siemens/ Feuerx
Supply, installation, testing and commissioning of multibend IR3 flame detector LPCB, FM, ATEX & PESO complete all as directed. Make: AGCO/ Hochiki/ Siemens/ Feuerx
Supply, installation, testing and commissioning of UL listed and FM approved intelligent addressable output module for hooters/ sounders/ strobes etc complete all as specified and directed. Make: JCI/ Hochiki/ Siemens/ Feuerx
Supply, installation, testing and commissioning of UL listed and FM approved intelligent addressable monitor module for sprinkler flow switch and door holders complete all as specified and directed. Make: JCI/ Hochiki/ Siemens/ Feuerx
Supply, installation, testing and commissioning of UL listed and FM approved intelligent addressable double action manual pull station, shock and vibration resistant, pull down lever remains down untill reset shall be polarity insensitive complete all as specified and directed. Make: JCI/ Hochiki/ Siemens/ Feuerx
Supply, installation, testing and commissioning of UL listed and FM approved intelligent addressable sounder with strobe having multi tone settings with range of 78db to 87db complete all as specified and directed. Make: JCI/ Hochiki/ Siemens/ Feuerx
Supply, installation, testing and commissioning of response indicator complete all as specified and directed. Make: JCI/ Hochiki/ Siemens/ Feuerx
Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electrical control cable with stranded copper conductor of size 1.5Sqmm 2 core complete all as specified and directed.
Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electrical control cable with stranded copper conductor of size 1.5Sqmm 4 core complete all as specified and directed.
SITC 1KVA online UPS with 15min battery backup complete all as specified and directed. Make: Emersion, Microtec, APC
Supply and testing of siren 2 Km range complete all as specified and directed
EOT CRANE
Design, supply, erect, test and commissioning of electrically operated over head travelling crane 5 Ton capacity rail mounted double girder type class-II with hoisting mechanism, control panel electric motor and gear driven, long cross travel VVVF control dries for normal and micro speed control operated from floor and safety devices for smooth functioning of EOT crane. All motor shall be Sq cage foot/ flange mounted, gear box shall be helical type gearing duly hardened and totally enclosed complete with rope drum,
wire rope with four falls complete with lockable type bottom block pulley, limit switches etc complete with EMDC brake in hoist motion. Control panel shall be made out of 16 SWG MS sheet duly powder coated with suitable rating of power/ control contactors and VVF drive for all the three motion i.e hoist, LT and CT duly wired for dual operation i.e push button with frequency control remote operation of EOT crane. New shrouded type TPN PVC insulated DSL system of suitable rating of 415 Volts, 4wire of suitable capacity, including current collector supporting brackets, insulators and other standard fixtures and fittings, buffers including all safety devices. Designing manufacturing with radio remote controller with receiver unit. The remote should have atleast two speed variations of hoist, LT and CT motion with atleast four spare push buttons. New armoured copper cable of suitable capacity for crane. New MCCB in MS enclosure pedestal/ wall mounted type of suitable capacity. The whole EOT crane structure and connected equipment to be painted with golden yellow/ tractor orange colour after applying red oxide primer complete all as specified and directed. The following requirement confirming to IS-807, IS-2148, IS 3177, IS-3938 and IS-3815 complete all as specified and directed. Detailed specification of crane are covered in Annexure 'A" (a) Capacity : 5 Ton (b) 5 Ton with Long travel- 100m (ii) Hook height 5.0m from finished floor level. (c) Speed- (i) hoist- 2MPM (ii) creep- 0.2 MPM (iii) LT-5 MPM (iv) CT-5 MPM (v) Hall size : 100 x 50m (vi) Cross travel :- 50m
Design, supply, erect, test and commissioning of electrically operated over head travelling crane 1 Ton capacity rail mounted double girder type class-II with hoisting mechanism, control panel electric motor and gear driven, long cross travel VVVF control dries for normal and micro speed control operated from floor and safety devices for smooth functioning of EOT crane.
All motor shall be Sq cage foot/ flange mounted, gear box shall be helical type gearing duly hardened and totally enclosed complete with rope drum, wire rope with four falls complete with lockable type bottom block pulley, limit switches etc complete with EMDC brake in hoist motion. Control panel shall be made out of 16 SWG MS sheet duly powder coated with suitable rating of power/ control contactors and VVF drive for all the three motion i.e hoist, LT and CT duly wired for dual operation i.e push button with frequency control remote operation of EOT crane. New shrouded type TPN PVC insulated DSL system of suitable rating of 415 Volts, 4wire of suitable capacity, including current collector supporting brackets, insulators and other standard fixtures and fittings, buffers including all safety devices. Designing manufacturing with radio remote controller with receiver unit. The remote should have atleast two speed variations of hoist, LT and CT motion with atleast four spare push buttons. New armoured copper cable of suitable capacity for crane. New MCCB in MS enclosure pedestal/ wall mounted type of suitable capacity. The whole EOT crane structure and connected equipment to be painted with golden yellow/ tractor orange colour after applying red oxide primer complete all as specified and directed. The following requirement confirming to IS-807, IS 3177, IS-3938 and IS-3815 complete all as specified and directed. Detailed specification of crane are covered in Annexure 'A" (a) Capacity : 1Ton (b) Hall sizes 5m x 6m x 2.60m (i) 1 Ton with long travel :- 6m
(ii) Cross travel - 5 m (iii) Hook height 2.6m from finished floor level (c) Speed:- (i) hoist - 2MPM (ii) Creep - 0.2 MPM (iii) LT-5MPM (iv) CT- 5MPM
PNEUMATIC SUPPLY
Supply and install butterfly valve of 150mm dia confirming to IS -13095 complete all as specified and directed.
All as per item No.167 herein before but 100mm dia
All as per item No.167 herein before but 80mm dia
All as per item No.167 herein before but 50mm dia
Supply and fixing of nozzle suitable for fixing 20mm dia GI/ MS pipe complete all as specified and directed.
Material and labour of air reservoir of 7Kg/cm², 3 metre height at different location for air compressor of capacity 250 Cubic ft complete all as specified and directed. Kirloskar model DTB-JM or equivalent in specified makes
Material and labour for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick, burried directly in ground , vertically to a depth not less than 2.5 mtr deep deep below ground level with top edge of the earth plate at depth not less than 1.5 mtr below ground level earth plate surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, earth lead as GI strip 32x6mm by means of bolts,nuts ,check nuts and washers of galvanised iron and thimbles and earth lead protected by galvanized iron pipe light grade 40 mm bore and water pipe 20 mm bore GI medium grade with funnel and wire mesh complete including excavation and earth work, PCC chamber and cover in cement concreate 1:3:6 type C-1 uasing 20 mm graded stone aggregate in liew of CI cover and frame etc all as specified and shown in electrical plate No 3 of SSR-2010 Part I complete all as specified and directed.
Supply, install, testing and commissioning of factory made LT panel board indoor type for LT distribution switch gear and control gear, floor mounted, totally enclosed, cubical type modular compartment, dust and vermin proof with neoprene gasket, fabricated out of CRCA sheet of thickness not less than 2mm complete with two bus bar chamber having openable front and rear shutters with suitable locking arrangement of shutters, duly powder coated including PCC 1:2:4 type B-1 using 20mm graded stone aggregate foundation raised base complete all as specified and directed including the following component :-
Supply and fix Pneumatic supply line with 30m hose wound on drum of dia 565mm die cast manual swinging type with 19mm dia with gate valve and shut off nozzle complete with all accessories complete all as specified and direct.
FIRE FIGHTING SYSTEM
Supply, installation, testing and commissioning of 120 litres seamless cylinder (or as per calculation) with valve capable of withstanding pressure of 42 bat at 50 deg C calculation complete all as specified and directed.
Supply, installation, testing and commissioning of pressure gauge + Low pressure supervisory switch complete all as specified and directed. Make: Kidde/ Hochiki/ Siemens/ Feuerx
Supply, installation, testing and commissioning of SINORIX 1230/ FM200 complete all as specified and directed. Make: Kidde/ Hochiki/ Siemens/ Feuerx
Supply, installation, testing and commissioning of Electromagnetic Actuator. The actuator should be capable of withstanding pressure atleast of 90bar UL/VDS listed. Make: Kidde/ Hochiki/ Siemens/ Feuerx
Supply, installation, testing and commissioning of Manual Actuator. The actuator should be capable of withstanding pressure atleast of 100bar at 50 Deg C. UL/VDS listed. Make: Kidde/ Hochiki/ Siemens/ Feuerx
Supply, installation, testing and commissioning of Pneumatic Actuator. The actuator should be capable of withstanding pressure atleast of 100bar at 50 Deg C. UL/VDS listed. Make: Kidde/ Hochiki/ Siemens/ Feuerx
Supply, installation, testing and commissioning of Flexible Discharge Hose with minimum bending radius of 125mm and brusting pressure should be more or equal to 180 bar. UL/VDS listed. Make Kidde/Hochiki/Siemens/Feuerx).
Supply, installation, testing and commissioning of Flexible Actuation Hose with minimum bending radius of 75mm and brusting pressure should be more or equal to 660 bar. UL/VDS listed complete all as specified and directed. Make (Kidde/Hochiki/Siemens/Feuerx).
Supply, installation, testing and commissioning of Discharge Nozzle. The nozzle should be capable of handling at least 176 bar at 50deg c .Ul/ VDS Listed complete all as specified and directed. Make (Kidde/Hochiki/Siemens/Feuerx).
Supply, installation, testing and commissioning of Check Valve UL/VDS listed complete all as specified and directed. Make (Kidde/Hochiki/Siemens/ Feuerx)
Supply, installation, testing and commissioning of Flow Switch complete all as specified and directed. Make (Kidde/Hochiki/Siemens/Feuerx)
Supply, installation, testing and commissioning of Manifold complete for making header of gas cylinders complete all as specified and directed.
Supply, installation, testing and commissioning of Wall mount kit complete all as specified and directed.
Supply, installation, testing and commissioning of 2 Zone Gas Release panel with release module and battery backup complete all as specified and directed. Make (Kidde/Hochiki/Siemens/Feuerx/ Ravel).
Supply, installation, testing and commissioning of Abort Switch complete all as specified and directed. Make (Kidde/Hochiki/Siemens/Feuerx/ Ravel).
Supply, installation, testing and commissioning of M.S. Seamless pipes of 80mm dia as per ASTM A 106 Gr. B, schedule 40 with necessary fittings complete all as specified and directed. Make jindal, MSS, TATA
All as per Item No.191 herein before but 65mm dia
All as per Item No. 191 herein before but 50mm dia
All as per Item No.191 herein before but 40mm dia
All as per Item No.191 herein before but 32mm dia
All as per Item No.191 herein before but 25mm dia
All as per Item No.191 herein before but 20mm dia
Supply & fixing of ISI marked (IS: 2878) portable Co2 fire extinguisher of capacity 4.5 kg flat base including valve discharge hose of not less than 10mm dia. meter complete in all respect including initial fill with Co2 gas confirming to IS 307-1966 and filled to filling ratio of not more than 0.367 complete all as specified and directed. Makes: (fireonil/Envos/Ceasefire/Kanex)
Supply & fixing of ISI marked Dry Chemical Power type 25 Kg Trolley Mounted Extinguisher as per IS: 10658 complete all as specified and directed. Makes: (fireonil/Envos/Ceasefire/Kanex)
Providing & fixing of ISI marked Co2 type 22.5 Kg Fire Extinguisher Trolley Mounted IS: 2878 complete all as specified and directed. Makes: (fireonil/Envos/Ceasefire/Kanex)
Providing & fixing of ISI marked Dry Chemical Power type 6 Kg Extinguisher as per IS: 15683 complete all as specified and directed. Makes: (fireonil/Envos/Ceasefire/Kanex)
Panel Protection Supply, Installation, Testing and Commissioning of 4 kg capacity Co2 , DLP Assembly with automatic valve, push in connector for tube, Co2 , mounting bracket, End of Line adopter and low pressure switch for monitoring system activation complete all as specified and directed. Make (Rotarex/Envos /Siemens/Freuerx).
Supply, Installation, Testing and Commissioning of Hooter with accessory complete all as specified and directed. Make (Rotarex/Siemens/Feuerx).
Supply, Installation, Testing and Commissioning of Linear Pneumatic heat Detection Tube with all necessary fittings & supports complete all as specified and directed. Make (Rotarex/Siemens/Feuerx/ firedetec).
FIRE FIGHTING FOAM FLOODING SYSTEM FOR HANGER Extinguishing system for Hangar:- The automatic fire extinguishing system should have hot foam total flooding system. It should be designed in such a way that the IR3 FLAME detectors mounted inside the hangar detect the flame/fire in any of the hangar section and transmits a signal to the control panel. The control panel shall give an output an audio/visual alarm, give the close signal to the electric operated door (in case they are in open position) and also start time delay circuit after the lapse of the set time, the panel shall give an output to the quick opening main deluge valve and the branch deluge valve based on the section from where the fire has been detected. When the main deluge valve, open the pressurized water from the water line flows into main distribution pipe line and begin to flow out the foam from foam generators mounted on the ceiling of the hangar.
The drop in pressure is sense by the pressure switch, which should start the main water pump providing the water demand of the sytem. The water pressure in the pipe line would also act on the foam bladder tank after required time delay the control panel opens the electrically operated foam solinoid valve. The foam concentrate from the bladder tank is squeezed out into the foam proportionator, which induct the foam in to the water line in the correct 2% ratio, the water foam solution then would induct the foam into the water line into the foam generators. At the foam generators the foam solution is expended to 400 times its volume by using internal air available in the section on fire. The expended foam fall into the section and quickly fill up the space thus depleting oxygen and also cooling the fire. However, in order to count for leakage/open door etc, the system should be designed to operate for maximum period once the foam concentrate valve is opened. In case the fire has been extinguished the system can be stopped manually Make :- Complete Foam Flooding should be of FIRE TECH, TYCO OR SKUM ENVOS Hot foam generator 40 cub meter/ Min - 180 Nos. Vertical foam bladder tank 2500 litres - 2Nos. In line foam proportionator TP 100/50 - 2Nos. 2 % AFFF Meter or P+ foam concentrate liters (Non freezing type) - 5000 Ltrs Deluge valve station of 250 mm dia - 3Nos.
Note: Bladder tank shall be designed as per ASME Sec. VIII Div. 1 for a rated service pressure of 12 Bar and hydro tested for pressure of 18 Bar. Water piping shall be of carbon steel ASTM A 106 Gr. B Sch.40 and foam piping of stainless steel 304 Sch.40. Foam proportioner shall be of 50NB flanged ends with stainless steel 304 internals. Hose reel shall be provided with 30 meters of rubberized hose and provided with foam branch pipe of 225 LPM. The complete assembly shall be mounted on a carbon steel base frame. Foam concentrate shall be AFFF 3% freeze protected and UL listed provided with the tanks. Bladder tank skid consisting of 200 litres Bladder tank UL listed with 50NB foam proportioner 4Nos.
Supply & fixing, testing & commissioning of M.S pipe of 350mm bore HEAVY Class ‘C’ ISI marked as per IS: 1239/3589 Part-I including cutting, screwing, welding etc. with all fittings as tees, elbows, reducers, flanges clamps hangers painting with one coat of primer and two coats of synthetic enamel paint of approve shade complete all as specified and directed. Make jindal, Surya TATA
All as per item No.206 herein before but 300mm bore
All as per item No.206 herein before but 250mm bore
All as per item No.206 herein before but 200mm bore
All as per item No.206 herein before but 150mm bore
All as per item No.206 herein before but 100mm bore
All as per item No.206 herein before but 80mm bore
Supply & fixing, testing & commissioning of G.I pipe 250mm bore HEAVY Class ‘C’ ISI marked as per IS: 1239/3589 Part-I including cutting, screwing, welding,jointing and excavation etc. with all fittings as tees, elbows, reducers, flanges clamps hangers painting with one coat of primer and two coats of synthetic enamel paint of approve shade complete all as specified and directed. Make jindal, Surya TATA
All as per item No.213 herein before but 200mm bore
All as per item No.213 herein before but 150mm bore
All as per item No.213 herein before but 100mm bore
All as per item No.213 herein before but 80mm bore
All as per item No.213 herein before but 65mm bore
All as per item No.213 herein before but 50mm bore
All as per item No.213 herein before but 32mm bore
All as per item No.213 herein before but 25mm bore
Supply, fixing, testing & commissioning of 300 mm dia 6.35 mm thick flanged end basket 300mm height of Y-type strainer made from MS body with bottom and top removable flanges with nuts, bolts etc having filteration area at least 6 times the cross sectional area of the pipe complete all as specified and directed.
Supply, fixing, testing & commissioning of 250 mm dia 6.35 mm thick flanged end basket 450mm height of Y-type strainer made from MS body with bottom and top removable flanges with nuts, bolts etc having filteration area at least 6 times the cross sectional area of the pipe.
Supply, fixing, testing & commissioning of C.I. Butterfly valve conforming to IS : 13095 [PN 1.6 rating] with flanges, nuts, bolts and washers complete for 250mm dia complete all as specified and directed.
All as per item No.224 herein before but 200mm dia
All as per item No.224 herein before but 150mm dia
All as per item No.224 herein before but 100mm dia
All as per item No.224 herein before but 80mm dia
All as per item No.224 herein before but 65mm dia
All as per item No.224 herein before but 50mm dia
Supply, fixing, testing & commissioning of dual plate non-return valve of 250mm dia complete with nuts, bolts and washers complete all as specified and directed.
All as per item No.231 herein before but 200mm dia
All as per item No.231 herein before but 150mm dia
All as per item No.231 herein before but 100mm dia
All as per item No.231 herein before but 80mm dia
All as per item No.231 herein before but 65mm dia
All as per item No.231 herein before but 50mm dia
Supply, fixing, testing & commissioning of Sluice valve 250mm dia complete with nuts, bolts and washers.PN 1.6 complete all as specified and directed.
All as per item No.238 herein before but 200mm dia
All as per item No.238 herein before but 150mm dia
All as per item No.238 herein before but 100mm dia
All as per item No.238 herein before but 80mm dia
All as per item No.238 herein before but 65mm dia
All as per item No.238 herein before but 50mm dia
Supply, fixing, testing & commissioning of 100 mm dia Burden type, Stainless Steel dial type pressure gauge (in Pump Room) including brass isolation valve and pipe having caliberation of 0-15 Kg/cm2 complete all as specified and directed.
Supply and fixing exhaust, Diesel engine driven pump exhaust M. S. pipe class 'C' 150 mm dia including fitting like flanges, bends, reducers, etc. 50 mm thick fibre wool insulation aluminium cladding, 21 gauge, necessary excavation, fixing of silencer connections at engine exhaust, necessary supports, back filling, cutting and making good, bird proof and weather proof flap complete in all respect as directed.
Supply and fixing M.S. structural work fabricated from standard sections, (MS rounds, angles, channels etc.) including cutting to size, drilling welding including cost of fasteners clamps in R.C.C. structural members as directed, including two or more coats of synthetic enamel paints over one coat of primer after surface preparation including cutting and making good walls complete all as specified and directed.
Electric Motor Driven Pump (Location - Plant Room ) Supplying, installing, testing and commissioning of Electrical driven fire pump suitable for automatic/ manual operation consisting of the following: Horizontal mounted SPLIT CASE multistage type fire pump having cast iron body, bronze impeller, stainless steel shaft & capable of delivering 9000 LPM against a total head of 70 M while running at 1450 RPM complete with mechanical seal pressure gauge with GM cock on the delivery side of pump and including 50 mm by pass arrangement (with 50 mm valve and up to 5 meter GI class 'B' pipe) for periodical testing of working of pumping test.
Squirrel cage, induction motor TEFC type suitable for 415 + 10%V, 3 phase, 50 Hz, AC supply, of suitable HP rating for the above pump with synchronous speed of 1450 RPM with flexible coupling and coupling guard . Common bed plate for mounting pump and motor fabricated of mild steel channel as per manufacturer's recommendation with heavy duty Anti Vibration pads (6 Nos., heavy duty). Coupling and coupling guard for direct coupling of pump and motor. Drain Pipe with Valve (50 mm dia) Main Fire Pump/Sprinkler Pump Discharge : 9000 LPM App. Head : 75 M Make of pumps : Kirloskar/ KSB/ Grandfoss
Diesel Engine Driven Fire Pump [Stand by pump] (Location - Plant Room :) Supplying, installing, testing & commissioning of Diesel Engine driven fire pump suitable for automatic/manual operations consisting of the following: Horizontal mounted split casing type fire pump having cast iron body, bronze impeller, stainless steel shaft & capable of delivering 9000 LPM against a total head of 70 M while running at 1450 RPM complete with mechanical seal pressure gauge with GM cock on the delivery side of pump including 50 mm bypass arrangement (with 50 mm valve and upto 5 meter GI class 'B' pipe) for periodical testing of working of pumping set pumps.
Radiator cooled diesel engine of suitable BHP at 1450 RPM for the above pump complete with standard accessories & suitable cooling system as described in specifications. Common base plate for mounting pump & engine of requisite strength manufactured out of M.S. channels as per manufacture's recommendation with heavy duty Anti Vibration pads. (Cushy foot) (6 nos., heavy duty) Coupling & coupling guard for direct coupling of engine & pump. 500 liters capacity day oil storage tank fabricated from 16 SWG thick M.S. plates. Tank shall be provided with inlet, outlet, overflow, vent, drain connections, filling connection & level indicator. Tank shall be mounted on a suitable steel structure (Painted with 2 coats of red oxide paint). Tank shall be provided with epoxy coat from inside & two or more coats of synthetic enamel paint outside over two coats of red oxide primer. 24 volts 180 AH lead acid battery (12 volts - 2 Nos) with boost/Trickle charger for starting the engine automatically complete as required. Provision for starting of Engine automatically in case of power failure at the time of fire Diesel Engine driven pump of: Discharge: 9000 LPM App. Head: 75 M Make of pumps : Kirloskar/ KSB/ Grandfoss
Electrical Motor Driven Jockey Pump Location - Plant Room : Supplying, installing, testing & commissioning of electrically driven Jockey pump suitable for automatic/manual operation consisting of the following: Horizontal mounted end suction jockey pump having cast iron body, volute bronze impeller, stainless shaft capable of delivering 180 LPM against total head of 70 M while running at 2900 RPM complete with mechanical seal pressure gauge with mechanical seal GM cock on the delivery side of pump including bypass arrangement (with 25 mm GM stop valve and up to 5 meter G.I. class 'B' pipe) for testing of working of the pumping set as required.
Squirrel cage induction motor suitable for 415 + 10%V, 3 phase, 50 Hz, AC supply of suitable HP rating for the above pump with synchronous speed of 2900 RPM T.E.F.C type connected to pump with flexible coupling and coupling guard . Common bed plate for mounting pump and motor fabricated of mild steel channel as per manufacturer's recommendation with heavy duty 4 Nos. Anti Vibration pads.(Cushy foot) Drain pipe with valve (25 mm dia) Jockey Pump :- Discharge : 180 LPM (3 LPS) App Head : 70 M Make of pumps : Kirloskar/ KSB/ Grandfoss
Electrical Motor Driven Main Hydrant Pump Location - Plant Room : Supplying, installing, testing and commissioning of Electrical driven fire pump suitable for automatic/ manual operation consisting of the following: Horizontal mounted End Suction type fire pump having cast iron body, bronze impeller, stainless steel shaft & capable of delivering 2850 LPM against a total head of 70 M while running at 2900 RPM complete in all respect.
Squirrel cage, induction motor TEFC type suitable for 415 + 10%V, 3 phase, 50 Hz, AC supply, of suitable HP rating for the above pump with synchronous speed of 2900 RPM with flexible coupling and coupling guard . Common bed plate for mounting pump and motor fabricated of mild steel channel as per manufacturer's recommendation with heavy duty Anti Vibration pads (4 Nos., heavy duty). Coupling and coupling guard for direct coupling of pump and motor. ( Make: kirloskar/ crompton/ mather & platt ) Drain Pipe with Valve (50 mm dia) Main Fire Pump Discharge : 2850 LPM App. Head : 70 M Make of pumps : Kirloskar/ KSB/ Grandfoss
Supply, installation, testing and commissioning of Pressure switch of approved make for Hydrant pump, jockey pump and Diesel Engine Driven pump including necessary wiring and cut off valve up to central panel & other material as described in specifications.
Supply, installation, testing and commissioning of suitable Air Cushioning tank (Air Vessel ) 250 mm Dia x 1000 mm High with dished top, made od minimum 6 mm think MS pipe / plate complete with 20 mm dia stop valve, Pressure Gauge with brass stop cock, nipple tees elbows and all accessories complete all as specified and directed.
Main Fire Pump Panel: Adequate size cable alley shall be provided all round the panel and in the back for each cable bending and termination. The panel shall be fabricated by CPRI approved vendor. The outgoing feeders inside the panel shall be connected through solid bus bars. Flexible cable links are not acceptable. Bus bars shall be provided with heat shrinkable sleeves and shall be colour coded. The panels shall be suitable for cable entry from top. The minimum fault rupturing of all incoming and outgoing switches/breakers shall be 35 KA.
Supply, installation, testing & commissioning of single core 240sqmm of 1100 V grade PVC copper conductor cables, PVC insulated PVC sheathed, including cable trays of min 300 mm width /supports as per site conditions complete all as specified and directed.
All as per Item No.255 herein before but single core 35 Sqmm
Supply & making end termination with brass double compression glands for 3 core 400 Sqmm PVC insulated, PVC sheathed & armoured 1100 V grade Aluminium cable including cost of crimping lugs/ferrules, compression glands, solder, cable sockets, insulation tape etc complete as required complete all as specified and directed.
All as per Item No.257 herein before but 3 core 35Sqmm
All as per Item No.257 herein before but control cable 4 core 1.5Sqmm
Material and labour for Body earthing of the various equipments/ motors/ switchgears supplied by the bidder with G.I earth strip of size 32 mm x 6 mm of as per IS:3043 and as required including provision for connection of earthing to main earthing pits complete all as specified and directed.
Supply and fixing M.S. structural work fabricated from standard sections, (MS rounds, angles, channels etc.) including cutting to size, drilling, welding, including cost of fasteners, clamps in RCC structural members as directed, including two or more coats of synthetic paint over one coat of primer after surface preparation including cutting and making good walls complete all as specified and directed.
Supplying & Fixing of single headed ISI marked oblique pattern hydrant landing valves with 80mm dia flanged inlet & 63 mm dia female outlet complete with gun metal cap and GI chain twist release type plugh and all accessories as per IS : 5290-1983 Type A (For internal + external hydrant) complete all as specified and directed.
Supplying & Fixing of 63 mm dia 15 m long non-percolating flexible hose (RRL- type A) as per IS : 636. Type A with Gunmetal male & female instantaneous type coupling (IS 903) (For internal hydrant system) complete all as specified and directed. Make: MEC/ ATASEE/ NEW EDGE
Supplying & Fixing of 63 mm dia branch pipe with nozzle of 20 mm nominal bore outlet as per IS:8090 suitable to fit with standard instantaneous type 63mm dia coupling ISI marked (IS:8090) complete all as specified and directed. Make: MEC/ ATASEE/ NEW EDGE
Supplying & Fixing of standard Fireman's Axe with heavy insulated handle conforming to (IS:926) complete all as specified and directed.
Supplying & Fixing of wall mounting swinging type first aid fire hose reel with drum, hanging bracket, 30 Mtr. length x 20 mm dia high pressure hose reel tubing as per IS: 444 with gun metal (GM) shut off nozzle having 5 mm dia orifice. The hose reel shall be conforming to IS : 884-1985. Rate shall include 25 mm dia M.S. pipe connection from Riser to hose reel, sockets, nipples, elbows and ball valve (25 mm dia). Drum shall be fixed on adjoining wall through anchor fasteners / cement concrete block as and when required (For internal hydrant system) complete all as specified and directed. Make: MEC/ ATASEE/ NEW EDGE
Supplying & Fixing of weather proof standard fire hose cabinet (900 mm x 600 mm x 300 mm deep) for yard hydrants made of 16 SWG powder coated M.S. sheet having single or double opening glazed (4.0 mm thick glass) shutter including necessary locking arrangement by allan key, stove enamelled Fire red finish with " Fire Hose" marked on front, suitable for housing 2 nos. Hose pipe, 1 No. branch pipe & nozzle spanner complete all as specified and directed.
Supplying & Fixing of gun metal two way fire brigade inlet to hydrant ring with 63 mm dia instantaneous type inlet and 150 mm dia flanges outlet conforming to IS:904 with blank cap and chain including 150 mm dia butterfly valve (PN 1.6 rating) and wafer type non-return valve complete with nuts, bolts, flanges and complete in all respect. Cost shall include a wall mounted box of M.S. construction (16 SWG) with glass door (4.0 mm thick) to house the above mentioned component complete all as specified and directed. Make: MEC/ ATASEE/ NEW EDGE
Supplying & Fixing of gun metal four way fire brigade tank filling connection having 63 mm dia instantaneous type inlet and 150 mm dia flange outlet conforming to IS:904 with blank cap and chain with necessary 150 mm dia MS (heavy duty) pipe and flanges, nuts, bolts etc. Cost shall include a wall mounted box of M.S. construction (16 SWG) with glass door (4.0 mm thick) to house the above mentioned component complete in all respect as specified and directed. (For Tank Fillings). Make: MEC/ ATASEE/ NEW EDGE
Supplying & Fixing of 100 mm dia gun metal fire brigade suction hose coupling of (gunmetal draw off connection) with 100 mm dia M.S. 'C’ Class suction pipe with 100 mm dia C.I. foot valve. (Pipe max. 10 m long). Cost shall include a wall mounted box of M.S. construction (16 SWG) with glass door (4.0 mm thick) to house the above mentioned component to be connected to static water tank complete all as specified and directed. Make: MEC/ ATASEE/ NEW EDGE
Supplying & fixing air release valve of 25 mm dia and 25 mm dia gun metal gate valve with fittings etc. as per the requirement with air-cushion-tank 250 mm dia. 1 M high complete all as specified and directed. Make: BIR/ DRP/ ZOLOTO
Supplying and laying light duty non pressure NP-3 Class RCC pipe S/S jointed with stiff mixture in the proportion 1:2, 300 mm dia R.C.C. Hume pipe for underground hydrant pipe at road crossings including collar pieces and filling inside of pipe with sand complete as required including necessary excavations and back filling. (For road crossing) complete all as specified and directed.
Supplying and applying two coat of 4 mm thick 'PYPKOTE' antirust protection including primer and lap of 25 mm on M.S. pipe in trenches or complete including surface preparation coating and wrapping shall be confirm to ISI 10221 complete all as specified and directed.
Material and labour Excavation of required width for fire fighting pipes including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil and then returning the soil as required in layer not exceeding 20 cms in depth including consolidating each deposited layers by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 100m for all kinds of soil.
Constructing brick masonry chamber 1200 x 1200 x 1000 mm internal dimensions with 75 class designation brick work in cement mortar 1:5 (1 cement :5 fine sand) for butterfly valve, with C.I. medium duty manhole cover fixed in concrete slab 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size), necessary excavation, foundation concrete 1:5:10 (1 cement :5 fine sand :10 graded stone aggregate 40 mm nominal size) and 12 mm thick inside plastering with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement complete as per standard design as specified and directed.
STANDBY POWER SUPPLY
Supply, installing, testing and commissioning of diesel engine driven as per norms of CPCB acoustic enclosures driven generating set 630 KVA 3 phase ( Prime Power Rating) 4 wire 415 volts (1500 RPM 50 Hz power supply with power factor 0.8 automatic start on main failure, with fuel tank maintenance free battery and standard accessories and fitting, PCC foundations as recommended by manufacture anti Vibration pad, sand cushioning around PCC foundation, Tools and spares to be provided by manufacturers all as specified and directed.-
(a) Engine. Water cooled diesel engine , Natural asperation - suitable capacity for 630 KVA alternator under NTP condition with provision of 10% over load for one hour in every 12 hours confirming to IS0 8528. The engine shall consist of the following :- Fly wheel, direct coupling, cooling radiator, water pump engine mounted, suitable capacity alternator for charging, air cleaner, radiator fan blower type with guard, fuel injector pump, piston, mechanical governor, fuel filter(mounted) 12 volts self regulating alternator bell driven by engine exhaust silencer heavy duty industrial type anti corrosion resistance filter, starter 24 volt DC, lubricating oil cooler, exhaust pipe . (b) OEM"S manufactured Instrument panel consisting of starting switch with key lubricant oil temperature gauge, lubricating oil pressure gauge, water temperature gauge , battery charging Ammeter, battery charging indicating lamp, hour meter with RPM indicator safety control light against low lubricating oil pressure, water over speed stop with double driven adopter. Warranty: 2 years of Unconditional- ( Comprensive by principal manufacturer ) (c) Brush less alternator. Alternator coupled in an indigenous alternator mounted on a strong steel fabricated frame suitable for mounting as permanent foundation. Alternator shall be confirming to BS 2613 or relevant IS-4722, type self excited self regulated with automatic voltage regulator rating -630 KVA at 0.8 PF lagging 4 pole horizontal at NTP condition. Speed 1500 RPM system 415 volt s plus minus 1 % AC phase 4 wire 50 Hz, connection -4 wire star connection enclosure screen protection drip proof. Ventilation - Self ventilated insulation - Class H. (d) Automatic main failure control panel.Outdoor type Cubical type by OEM's
Supply, installing, testing and commissioning of diesel engine driven as per norms of CPCB acoustic enclosures driven generating set 400 KVA 3 phase ( Prime Power Rating) 4 wire 415 volts (1500 RPM 50 Hz power supply with power factor 0.8 automatic start on main failure, with fuel tank maintenance free battery and standard accessories and fitting, PCC foundations as recommended by manufacture anti Vibration pad, sand cushioning around PCC foundation, Tools and spares to be provided by manufacturers all as specified and directed.-
(a) Engine. Water cooled diesel engine , Natural asperation - suitable capacity for 400 KVA alternator under NTP condition with provision of 10% over load for one hour in every 12 hours confirming to IS0 8528. The engine shall consist of the following :- Fly wheel, direct coupling, cooling radiator, water pump engine mounted, suitable capacity alternator for charging, air cleaner, radiator fan blower type with guard, fuel injector pump, piston, mechanical governor, fuel filter(mounted) 12 volts self regulating alternator bell driven by engine exhaust silencer heavy duty industrial type anti corrosion resistance filter, starter 24 volt DC, lubricating oil cooler, exhaust pipe . (b) OEM"S manufactured Instrument panel consisting of starting switch with key lubricant oil temperature gauge, lubricating oil pressure gauge, water temperature gauge , battery charging Ammeter, battery charging indicating lamp, hour meter with RPM indicator safety control light against low lubricating oil pressure, water over speed stop with double driven adopter. Warranty: 2 years of Uncondational- ( Comprensive by principal manufacturer ) (c) Brush less alternator. Alternator coupled in an indigenous alternator mounted on a strong steel fabricated frame suitable for mounting as permanent foundation. Alternator shall be confirming to BS 2613 or relevant IS-4722, type self excited self regulated with automatic voltage regulator rating -400 KVA at 0.8 PF lagging 4 pole horizontal at NTP condition. Speed 1500 RPM system 415 volt s plus minus 1 % AC phase 4 wire 50 Hz, connection -4 wire star connection enclosure screen protection drip proof. Ventilation - Self ventilated insulation - Class H. (d) Automatic main failure control panel.Outdoor type Cubical type by OEM's factory made floor mounted totally enclosed fabricated of MS sheet 16 gauge,
Supply, installing, testing and commissioning of diesel engine driven as per norms of CPCB acoustic enclosures driven generating set 320 KVA 3 phase ( Prime Power Rating) 4 wire 415 volts (1500 RPM 50 Hz power supply with power factor 0.8 automatic start on main failure, with fuel tank maintenance free battery and standard accessories and fitting, PCC foundations as recommended by manufacture anti Vibration pad, sand cushioning around PCC foundation, Tools and spares to be provided by manufacturers all as specified and directed.-
(a) Engine. Water cooled diesel engine , Natural asperation - suitable capacity for 320 KVA alternator under NTP condition with provision of 10% over load for one hour in every 12 hours confirming to IS0 8528. The engine shall consist of the following :- Fly wheel, direct coupling, cooling radiator, water pump engine mounted, suitable capacity alternator for charging, air cleaner, radiator fan blower type with guard, fuel injector pump, piston, mechanical governor, fuel filter(mounted) 12 volts self regulating alternator bell driven by engine exhaust silencer heavy duty industrial type anti corrosion resistance filter, starter 24 volt DC, lubricating oil cooler, exhaust pipe . (b) OEM"S manufactured Instrument panel consisting of starting switch with key lubricant oil temperature gauge, lubricating oil pressure gauge, water temperature gauge , battery charging Ammeter, battery charging indicating lamp, hour meter with RPM indicator safety control light against low lubricating oil pressure, water over speed stop with double driven adopter. Warranty: 2 years of Unconditional- (Comprensive by principal manufacturer ) (c) Brush less alternator. Alternator coupled in an indigenous alternator mounted on a strong steel fabricated frame suitable for mounting as permanent foundation. Alternator shall be confirming to BS 2613 or relevant IS-4722, type self excited self regulated with automatic voltage regulator rating -320 KVA at 0.8 PF lagging 4 pole horizontal at NTP condition. Speed 1500 RPM system 415 volt s plus minus 1 % AC phase 4 wire 50 Hz, connection -4 wire star connection enclosure screen protection drip proof. Ventilation - Self ventilated insulation - Class H. (d) Automatic main failure control panel.Outdoor type Cubical type by OEM's factory made floor mounted totally enclosed fabricated of MS sheet 16 gauge,
TARMAC/ TAXI TRACK
Material and labour for 150mm compacted thickness GSB, Grade-V deposited, levelled and spread in layer not exc 15cm thick, watered and well rammed to a true surface complete all as specified and directed.
Material and labour for WMM 200mm thick using granite or basalt of grading of size ( 63 to 40 mm size) 2 or 3 spread in 2 layers of 100mm thick each watered and well rammed to a true camber using mechanical paver with sensor (Min 9mtr wide) vibratory rollers pneumatic rollers complete all as specified and directed.
Material and labour for 150mm thick dry lean concrete Design mix M-15 using 180 Kg of cement/Cum complete all as specified and directed.
Material and labour for polythene film 400 micron thick HDPE sheet as per IS-2508 laid over sand layer including cutting overlaps not less than 300mm and waste complete all as specified and directed.
Material and labour for 250mm thick pavement quality concrete in pavements and flooring of min flexural strength 45 Kg/Sq.cm using min cement 400 Kg/Cum and as per design mix using non synthetic circular fibre @ 0.25% by wt of cement as per manufacturer insturctions to be laid using vibratory rollers, surface vibrators, vibrating screed & needle vibrators complete all as sspecified and directed.
Material and labour for forming construction joints 10mm wide, 25mm deep and filling with Polyurethane sealant compound and minimum movement accommodation Factor (MAF) + or -30% conforming to the requirement of BS:5212, BS-4252 and EN-141875-2003 for Hydrolysis/water resistance test including two coats of primer and providing 12mm dia approved quality closed cell polythene back up rod, applying masking tape on edge of joint to prevent accidental slippage of sealant on top surfaces and to give a net finish to the sealant and removing the masking tape after sealant is applied as required complete all aspecified and directed.
Material & Labour for forming dummy joints (using diamond cutter) 8mm wide, 85mm deep and filled with Polyurethane joint sealant compound using mechanical means to a to a minimum depth of 10mm (depth minimum above the back up rod ) and minimum movement Accommodation Factor (MAF) + or -30% conforming to the requirement of BS:5212, BS-4252 and EN-141875-2003 for Hydrolysis/water resistance test including two coats of primer and providing 10mm dia approved quality closed cell polythene back up rod over polymer board in position and applying masking taps on edge of joints to prevent accidental slippage on sealant on top surfaces and to give a neat finish to sealant and removing the masking tape after sealant is applied as required complete all as specified and directed.
Material & Labour for forming expansion joints 25mm wide, upto full depth of PQC filled with compressive filler board HD-100 and sealed with Polyurethane sealant compound using mechanical means to a depth of 15mm (depth minimum above the back up rod) and minimum movement Accommodation Factor (MAF) + or -30% conforming to the requirement of BS:5212, BS-4252 and EN-141875-2003 for Hydrolysis/water resistance test including two coats of primer and providing 30mm dia approved quality closed cell polythene back up rod separated by bond breaker tape) over polymer board in position as required all as per Manufacturer's instructions complete all as specified and directed.
Material & Labour for painting lines/dashes, arrows etc, pavement, runways and other like surfaces exceeding 10cm in with two coats of water based paint over primer & preparation of surface complete all as specified and directed.
Note: (i)The amount against Schedule of Credit on Page No.244 shall be deducted from the total amount quoted against Sch 'A' while deriving the Lump Sum for Acceptance.
NSC Projects Pvt. Ltd.
City Promoter and Buildwell Pvt. Ltd.
Som Projects Pvt Ltd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid