| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.9 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹49.6 L+₹25,334 (0.51%)Rejected-Finance | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹49.9 L+₹52,884 (1.07%)Rejected-Finance BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | L3 | Rejected-Finance Rejected being L3 | |
| 4 | L4₹51.1 L+₹1.8 L (3.64%)Rejected-Finance 606 80 FEET ROAD 7TH BLOCK 2ND PHASE BANASHANKARI 3RD STAGE BANGALORE 560 085 | BENGALURU URBAN | KARNATAKA | 560085 | L4 | Rejected-Finance Rejected being L4 | |
| 5 | L5₹51.2 L+₹1.9 L (3.75%)Rejected-Finance | L5 | Rejected-Finance Rejected being L5 |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
24 Sept 2021, 6:00 pmClosed
GE RD East Bangalore
GE RD East Bangalore 93
REPAIR REPLACEMENT OF UNSERVICEABLE WIRING AND ACCESSORIES UNSERVICEABLE DISTRIBUTION BOARDS AND ALLIED WORKS AT ZONE A PHASEII AREA UNDER AGE EM GEI R D EAST BANGALORE
2021_MES_472585_1
8172
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE I R AND D East Bangalore
D b (i)
8 documents required · 8 mandatory
₹500
Yes
GE I R AND D East Bangalore
₹88,000
Yes
27 Oct 2021
3 Sept 2021
27 Sept 2021
3 Sept 2021
24 Sept 2021
18 Sept 2021
4 Sept 2021 - 13 Sept 2021
Amount
Taking down carefully U/S aluminium/ copper point wiring (light, fan,socket or power) complete with fittings such as switches, sockets, ceiling rose, light fittings etc , removing all material for reuse/ issued under sch of credit and making good the distrubed surface as the existing one, complete all as directed.
Taking down unserviceable DBs including MCCBs/MCBs complete issued under sch of credit and making good the distrubed surface as the existing one, complete all as directed.
Taking down old sub main wiring of any type and size complete all as specified and directed .
M &L for Point wiring complete with Multi stranded copper conductor size 1.5 sqmm PVC insulated, unsheathed,FRLS cable , 1100 volts grade conforming to IS 694 multistranded , drawn in rigid PVC type conduit concealed in walls / floors/ ceiling etc with and including metal flush boxes of suitable size and modular white plate with frame for mounting of fittings, modular type switches, regulator and also including 1.5 sqmm PVC insulated unsheathed copper cable green in colour as continuous earth continuity conductor and connecting to earth dolly,cutting chasis to the wall s/ floors/ ceiling and repairing with existing surface after work ,complete all as specified and directed.
One light/ fan/exhaust fan point controlled by one way switch.
One light point controlled by 02 two way switches .
One three pin socket outlet 6 amps socket on the same board with other switches .
One 3 pin socket point 5 Amps on the independent board.
One bell point controlled by one bell push .
All as per item No 4 here-in-before but using copper conductor 2.5 sqmm PVC insulated unsheathed FRLS cable with copper conductor size 1.5 sqmmm PVC insulated unsheathed continuous earth continuity for 3 pin 15 amps soket outlet independently all as specified and as directed by engr-in-charge.
Supply & fix switch modular type single pole 1 way 6 Amp 230 volt complete as directed.
Supply & fix switch modular type single pole 2 way 6 Amp 230 volt complete as directed.
Supply & fix socket 6 Amps modular type, 230 volts grade all as directed.
Supply & fix switch modular type 1 way 16A, 1 module all as specified and directed.
Supply & fix Socket Modular type 6A/16A 2-3pin combined 2 module 230Volts grade all as directed.
Supply & fix Modular switch bell push 6 Amps one module all as specified and directed by Engr-in-Charge.
Supply & fix modular type fan regulator 120 W two module complete all as specified and directed by Engr-in-Charge .
Supply and fix bell music AC 230V single phase all as specififed and directed by Engr-in-Charge.
Supply & fix ceiling rose surface bakelite two to three terminal complete all as directed.
Supply & Fix angle holder polycarbonat/bakelite type with back plate complete all as specified and directed including one number LED lamp of 9 Watts.
Supply and replacement of LED type 4 feet tube light batten fitting surface mounted of 20 Watts extruded aluminium housing high lumen output complete all as specified and directed .
Supply and replacement LED mirror light fitting surface mounted of capacity of 10W with plastic body and accessories complete all as specified. including connecting to ceiling rose with twin copper conductor of size 0/0.24 complete all as specified and directed .
Supply and replacement of LED type surface mounted decorative bulk head fitting edge lit of 10Watts complete including connecting to ceiling rose with twin copper conductor of size 0/0.24 all as specified and directed.
Dismantling the ceiling fan complete of any type and size from the various buildings and cleaning, servicing, greasing to bearings checking of nuts bolts , safety split pin, bushes , capacitor and complete testing after painting the ceiling fan ,blades ,down rod etc and refixing the site / bldg with complete connection all as directed and specified by Engr in charge. Note :- Expendable stores like cotton waste/cleaning materials, grease, lubricants, machine screws, safety split pin, bots/nuts and transportation to and from site to work place are deemed to be included in rate quoted
Dismantling all components of ceiling fan 1200mm sweep, cutting and removing burnt out copper wining from the rotor assy and rewinding with super enamelled copper winding wire of suitable gauge and turns with necessary insulation materials , varnishing, reassembling , greasing to bearing , replacing bushes, replacment of capacitor and complete testing all as directed. Note:- (a) The spares like ball bearing, capacitor and GM bush required for repair the ceiling fan will be measured and paid separately under respective item. (b) Expendable stores like cotton waste /cleaning materials, grease, lubricants, machine screws, safety split pin, bolts, nuts and transportation to and fro from site to work place are deemed to be included in rate quoted.
All as per item No.20 herein before but for 1400mm sweep ceiling fan
All as per item No.20 herein before but for 300mm sweep exhaust fan
All as per item No.20 herein before but for 450mm sweep exhaust fan
Supply and replace worn out fan bearings of the existing size of superior quality complete all as specified and directed
Supply and replace capacitor 2.5mfd suitable for 1200mm sweep ceiling fan complete all as specified and directed
Supply and replace capacitor 4.0mfd suitable for exhaust fan complete all as specified and directed
Supply and replace rubbr reel of superior quality along with gun metal frame and split pin complete all as specified
Supply and fix exhaust fan louvers on outside of the external wall suitable for 300/ 380mm sweep for G+5 buildings complete all as specified and as directed .
Supply and fix exhaust fan louvers on outside of the external wall suitable for 450mm sweep for G+5 buildings complete all as specified and as directed.
M & L for submain wiring of 2 run 4 Sqmm size PVC insulated unsheathed multistranded copper conductor 1100 Volts FRLS grade drawn through and including suitable size of PVC conduit /existing conduit /surface with accessories concealed in wall/roof including one run of 2.5 Sqmm PVC insulated multistranded copper wire for earth , ISI marked and connecting up complete including removing old unserviceable cables all as specified and directed by Engr-in-Charge
M & L for submain wiring of 2 run 6 Sqmm size PVC insulated unsheathed multistranded copper conductor 1100 Volts FRLS grade drawn through and including suitable size of PVC conduit /existing conduit /surfaceaccessories concealed in wall/roof including one run of 4.0 Sqmm PVC insulated multistranded copper wire for earth , ISI marked and connecting up complete including removing old unserviceable cables all as specified and directed by Engr-in-Charge
M & L for submain wiring of 4 run 10 Sqmm size PVC insulated unsheathed multistranded copper conductor 1100 Volts FRLS grade drawn through and including suitable size of PVC conduit /existing conduit /surfaceaccessories concealed in wall/roof including two run of 6.0 Sqmm PVC insulated multistranded copper wire for earth , ISI marked and connecting up complete including removing old unserviceable cables all as specified and directed by Engr-in-Charge
Supply and fix in replacement of MCB DB SPN 4 way DB double door type single phase 230 Volts complete including dismantling the old one all as specified and directed
Supply and fix in replacement of MCB DB SPN 8 way DB double door type single phase 230 Volts complete including dismantling the old one all as specified and directed .
Supply and fix in replacement of MCB DB SPN 12 way DB double door type single phase 230 Volts complete including dismantling the old one all as specified and directed .
Supply and fix in replacement of MCB DB SPN 16 way DB double door type single phase 230 Volts complete including dismantling the old one all as specified and directed .
Supply and fix in replacement of MCB SPN 6-32 Amps C Curve type 230 Volts single phase all as specified complete including dismantling the old one.
All as per above item No -37 but capacity of MCB SPN (40-63) Amps
Supply and fix in replacement of MCB SP (6-32) Amps C Curve 230 Volts single phase all as specified complete including dismantling the old one.
Supply and fix in replacement of MCB TP (25- 63) Amps C Curve type 415 Volts three phase all as specified complete including dismantling the old one .
Supply and fix in replacement of MCB TPN (16-32) Amps C Curve 415 Volts three phase all as specified complete including dismantling the old one .
Supply and fix in replacement of MCB TPN (40-100) Amps C Curve 415 Volts three phase all as specified complete including dismantling the old one .
Suply and fixing in replacement of Hylum sheet with not less than 3mm thick of size 4" x 4"
Suply and fixing in replacement of Hylum sheet with not less than 3mm thick of size 4" x 6"
Suply and fixing in replacement of Boxes junctions, plastic, round, four terminals fixing in wall /ceiling as required at site /directed by Engr in charge.
Suply and fixing in replacement of switch piano flush type 6 amps one way type including taking down old one.
Suply and fixing in replacement of switch piano flush type 16 amps two way type including taking down old one .
Suply and fixing in replacement of socket 5 pin flush type 6 amps including taking down old one.
Suply and fixing in replacementof fan regulator flush type switch type 100/120 watt including taking down old one.
Suply and fixing in replacement of fan regulator flush type socket type 100/120 watt including taking down old one.
Suply and fixing in replacement of Switch socket combination 2 in 1, 6A flush type including taking down old one.
Suply and fixing in replacement of Switch socket combination 2 in 1, 3 pin, 6 and 16 Amp flush type universal type including taking down old one.
M & L for repair to existing broken switch board by taking out the old exisiting switches, sockets, regulators flush type and refixing the same after replacement of hylum sheet of required size under mentioned with complete electric connections and making screws and made functional with all electric connections as per speciifed and directed by Engr-in- charge. Note: Switches , sockets, regulators, hylum sheet, if required at site then it will be measured and paid separately.
Supply and fix in replacement of single phase Tamper proof electronic energy meter with LCD display 240Volts 2 wire system , 10-60Amps 50 Hz having accuracy class 1.00 as per IS-13779 complete with all standard anto tamper features including logging and display of tamper data complete including sealing properly with lead seals and wires and taking out the old unserviceable meter on complaint basis and deposit the same to AGE E/M Store Yard complete all as specified and directed by Engineer-in-Charge Make : L&T/Secure/AMTL
Supply and fix in replacement of Three phase Tamper proof electronic energy meter with LCD display 415 Volts 3 wire system , 10-60Amps 50 Hz having accuracy class 1.00 as per IS-13779 complete with all standard anto tamper features including logging and display of tamper data complete including sealing properly with lead seals and wires and taking out the old unserviceable meter on complaint basis and deposit the same to AGE E/M Store Yard complete all as specified and directed by Engineer-in-Charge Make : L&T/Secure/AMTL
supply only insulation tape roll (as per sample)
Earthing complete with galvanised steel earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground( earth pit not less than 2.25metres deep below the normal ground level) with top edge of the plate not less than 1.5m below normal GL connected as required 4.0 MM GI wire up to means of GI bolts, nuts , check nuts and washers and connected to building panel/DB all as shown in electrical plate No. 3 of SSR Part I and all as specified including testing on completion, taking down old unserviceable earthing complete all as specified and directed by Engr-in-Charge.
Earthing complete with galvanised steel earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground( earth pit not less than 2.25metres deep below the normal ground level) with top edge of the plate not less than 1.5m below normal GL connected as required 32 x 6mm upto 7.5Mtr GI strip up to means of GI bolts, nuts , check nuts and washers and connected to building panel/DB all as shown in electrical plate No. 3 of SSR Part I and all as specified including testing on completion, taking down old unserviceable earthing complete all as specified and directed by Engr-in-Charge.
S & F in replacment of LED driver suitable for LED street light fitting of capacity upto 70 Watts of existing make complete including taking down the old u/s fitting from pole / bldgs.Note : All T & P will provided by the contractor and No any extra cost will provided by the Dept.
S & F in replacement of LED driver suitable for LED street light of capacity upto 70 to 150Watts of existing make complete including taking down the old u/s fitting from pole / bldgs.Note : All T & P will provided by the contractor and No any extra cost will provided by the Dept .
S & F in repairs ball cock complete with epoxy coated aluminium rod and HDPE ball size 20 mm dia complete. Make : Prayag
S & F in repairs ball cock complete with epoxy coated aluminium rod and HDPE ball size 25 mm dia complete. Make : Prayag
M & L for servicing of 4 pole structure including greasing of 03 Nos GOD, replacemet of all jumpers with proper lugs/thimble, painting the structure and channels , replacement of wornout nuts bolts, replacement of blown fuses , trimming of tree branches including painting to the structure with aluminium paint over a coat of red oxide primer complete all as specified and as directed. Note: 1. Proper shut down should be taken in advance. 2. All Safety precautions should be taken by the tenderer
Materia & labour for cleaning of TPN DB box in each building by blower and checking the all incommer/outgoing MCBs/TPNs etc and tight the all ecectric loose connections and fixing of copper lugs through existing MCBs and after painting the complete the TPN DB Box as directed by Engr in charge
Taking down defective geyser/ storage water heater of any pattern/ capacities from existing position/place comprising of the following tasks:- (a) Inspectin ,taking down (dismantling) , descalling , brushing, cleaning of storage tank & painting internally with one coat of proprietary bitumnous composition not liable to impart taste or odour or otherwise contaminated water (b) Examine water tightness of storage tank after cleaning (c) Carryout operation of all stopcock, pressure reducing valves etc to ensure free movement of the working parts (d) Replace washers and glands of all taps & ball valves to ensure water tigtness. (e) Inspect overflow/vent pipes & remove blockagesobstructions if any (f) Check and correct earth continuity of electrical parts (g) Check, maintain and rent thermostats & tests its functioning (h) Checking and adjustment of pressure reducing valve (j) Checking of dead weight type high pressure release valve (HPRV) by removing dead weight position cleaning the seat & ensuring that the vent hole is not blocked /chocked (k) Check, maintain and rent thermostats & tests its functioning (l) Checking and adjustment of pressure reducing valve (m) Checking of dead weight type high pressure release valve (HPRV) by removing dead weight position cleaning the seat & ensuring that the vent hole is not blocked /chocked (n) Check, maintain and rent thermostats & tests its functioning (o) Checking and adjustment of pressure reducing valve
(p) Checking of dead weight type high pressure release valve (HPRV) by removing dead weight position cleaning the seat & ensuring that the vent hole is not blocked /chocked (q) Visual examination of fusible plug to ensure its intactness (r) Descalling of the immersion type heating element cleaning with diluted , hydrochloric acid solution & testing before refilling (s) Replacement of the rubber/PVC gasket to ensure water tightness (t) Testing of geyser after repairs (u) Refixing of geyser after testing and replacement of defective parts including new hold fastened including necesssary PCC work complete all as specified and directed
S & F in replacement of heating element of 2.0 KW rating as required at site (round & Tringle) including rubber washers of ISI marked .
Supply in replacement of thermostat for the geyser of following capacities with ISI marked -
S & F in replacement of PVC connection pipe with two brass adaptors 450mm long & connecting up complete all as specified and as directed (as per sample).
S & F in replacement of Geyser indicator (red /green) including taking down.
M & L for painting external part of the geyser body at site/ existing position with synthetic enamel paint by spraying including filling cavities with filler , one coat after cleaning complete all as specified and as directed
S & Fix Single pole and neutral enclosure with a two pin and earth plug and socket complete with one No 20 Amps MCB SP C curve type with complete connection all as directed and specified.
Note : Above work / Item will be operated / execauted on as per planning / breake down and user requirment basis,so contractor will depute their man power as per requirment basis as directed by JE/Engr in Charge on telephoncally . No extra cost will provided to the contractor.
Ashraya Nirman
RAHUL ENTERPRISES
Lucky Enterprises
SAI CONSTRUCTIONS
AishwaryaConstructions
G K CONSTRUCTIONS
HEERA CONSTRUCTION CO.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .